CMA Dishmachines PN13475.02 High Temp Upright Door Machines Drain Water Tempering Kit Installation Guide

September 4, 2024
CMA Dishmachines

Installation & Operation
High Temp Upright Door Machines
Drain Water Tempering Kit
PN13475.02 Factory Kit
PN13476.02 Field Kit

Drain Water Tempering Kit – Initial Installation Instructions

for Factory Installed Drain Water Tempering Kits

  1. Machine ships with tee, elbow fitting and CMA Drain Water Tempering (DWT) valve inside the machine.
  2. The DWT can be installed with or without the elbow as needed. 2. DWT with elbow installed before the tee with black plug installed. 2. DWT without elbow installed before the tee with black plug installed.
  3. Remove black plug.
  4. Connect cold water line to the in-line check valve. Installer responsible for water connection. Cold water connections not supplied by CMA Dishmachines.
  5. Turn on cold water and check for leaks.

Parts Manual

Drain Water Tempering Valve Assembly (Effective 03-2023)
PN13475.02 Factory Installed Kit
PN13476.02 Field Installed Kit

ITEM NO. NO. REQ’D P/N DESCRIPTION
1 1 13470.88 2 ABS Tee S x S x MIP
2 1 13470.87 DTV Adapter 2″ X 3/4″
3 1 13470.85 Drain Water Tempering Valve
4 1 00742.00 Nipple Brass 1/2 x 1-1/2
5 1 00715.00 1/2 Ball Check Valve
6 1 05030.10 2 x 3 ABS Tubing
1 01311.00 90 Degree ABS Street Elbow – not shown

MODEL CMA-180 PARTS MANUAL
Buy Parts

Documents / Resources

| CMA Dishmachines PN13475.02 High Temp Upright Door Machines Drain Water Tempering Kit [pdf] Installation Guide
PN13475.02, PN13476.02, PN13475.02 High Temp Upright Door Machines Drain Water Tempering Kit, PN13475.02, High Temp Upright Door Machines Drain Water Tempering Kit, Door Machines Drain Water Tempering Kit, Drain Water Tempering Kit, Water Tempering Kit, Tempering Kit, Kit
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CMA Dishmachines User Manuals

Related Manuals