CMA Dishmachines PN13475.02 High Temp Upright Door Machines Drain Water Tempering Kit Installation Guide
- September 4, 2024
- CMA Dishmachines
Table of Contents
Installation & Operation
High Temp Upright Door Machines
Drain Water Tempering Kit
PN13475.02 Factory Kit
PN13476.02 Field Kit
Drain Water Tempering Kit – Initial Installation Instructions
for Factory Installed Drain Water Tempering Kits
- Machine ships with tee, elbow fitting and CMA Drain Water Tempering (DWT) valve inside the machine.
- The DWT can be installed with or without the elbow as needed. 2. DWT with elbow installed before the tee with black plug installed. 2. DWT without elbow installed before the tee with black plug installed.
- Remove black plug.
- Connect cold water line to the in-line check valve. Installer responsible for water connection. Cold water connections not supplied by CMA Dishmachines.
- Turn on cold water and check for leaks.
Parts Manual
Drain Water Tempering Valve Assembly (Effective 03-2023)
PN13475.02 Factory Installed Kit
PN13476.02 Field Installed Kit
ITEM NO. | NO. REQ’D | P/N | DESCRIPTION |
---|---|---|---|
1 | 1 | 13470.88 | 2 ABS Tee S x S x MIP |
2 | 1 | 13470.87 | DTV Adapter 2″ X 3/4″ |
3 | 1 | 13470.85 | Drain Water Tempering Valve |
4 | 1 | 00742.00 | Nipple Brass 1/2 x 1-1/2 |
5 | 1 | 00715.00 | 1/2 Ball Check Valve |
6 | 1 | 05030.10 | 2 x 3 ABS Tubing |
— | 1 | 01311.00 | 90 Degree ABS Street Elbow – not shown |
MODEL CMA-180 PARTS MANUAL
Buy Parts
Documents / Resources
| CMA
Dishmachines PN13475.02 High Temp Upright Door Machines Drain Water Tempering
Kit
[pdf] Installation Guide
PN13475.02, PN13476.02, PN13475.02 High Temp Upright Door Machines Drain Water
Tempering Kit, PN13475.02, High Temp Upright Door Machines Drain Water
Tempering Kit, Door Machines Drain Water Tempering Kit, Drain Water Tempering
Kit, Water Tempering Kit, Tempering Kit, Kit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>