seitron Novo Industrial Combustion and Emissions Analyzers Instruction Manual

June 12, 2024
seitron

Novo Industrial Combustion and Emissions Analyzers

Product Information: Industrial Combustion & Emissions

Analyzers

The Industrial Combustion & Emissions Analyzers are designed
for analyzing emissions in various industrial applications such as
chemical industries, boilers, industrial burners, cement plants,
gas & diesel engines, mining operations, laboratories, and
biogas factories. These analyzers are manufactured by Seitron
Americas.

Industrial Emissions Analyzers Selection Guide

Parameters Novo 2-4 Novo-P 2-4 S6000 5 or 6
# of gases 02 Long Life, 0 – 25.0% CO, 0 – 8,000 ppm Calculated CO2 CO2

Sensor for Direct Measurement (0 .. 50%) Automatic CO Dilution
Auto-Range NO Sensor, 0 – 5,000 ppm NO2 Sensor, 0 – 1,000 ppm SO2
Sensor, 0 – 5,000 ppm Low NO, NO2, SO2 Sensor, 0 – 100.0 ppm CxHy
(HC) Pellistor, 0 – 5% vol CH4 H2S Sensor (standard or low range)
H2 Sensor, 0 – 2,000 ppm NH3 Sensor, 0 – 500.0 ppm CH4 NDIR Sensor,
0 – 100% v/v| Optional Optional Optional Optional Optional Optional
Optional| Optional Optional Optional Optional Optional Optional Optional
Optional
Features| BUILT-IN Printer (NON-FADING PAPER) Wireless Bluetooth Printer
FIELD-REPLACEABLE Pre-Calibrated Sensors Reporting & Storage
Software with Bluetooth Real-Time Software & Data Logging
Internal Memory Automatic Data Logging External Cooler Draft /
Differential Pressure Gas Velocity| Optional| Optional

Industrial Emissions Analyzers Features

The Industrial Emissions Analyzers come with various
features:

  • Calculated CO2, Efficiency, & Excess Air measurement
  • Built-in printer with non-fading paper
  • Wireless Bluetooth printer
  • Field-replaceable pre-calibrated sensors
  • Reporting & storage software with Bluetooth
  • Real-time software & data logging
  • Internal memory for storing test data
  • Automatic data logging
  • Built-in Thermo-Electric Peltier Chiller for cooling
  • Draft / Differential Pressure measurement
  • Gas Velocity measurement

Combustion Analyzers Selection Guide

Parameters| Novo 1 2-4| Novo 1-P 2-4| Novo 3 3| Novo 3-P 3| Novo 4 4| Novo 4-P 4
---|---|---|---|---|---|---
Features| Optional| Optional| Optional| Optional| Optional| Optional

Combustion Analyzers Features

The Combustion Analyzers come with the following features:

  • 7″ responsive touch screen for easy operation
  • Simple one probe connection for flue gas sampling

The new device has been redesigned to provide an improved and
easy-to-use experience. The large 7″ touchscreen ensures maximum
visibility of all information and offers a quick and smooth
browsing experience.

The major improvement in the analyzer is the innovative flue gas
sampling probe connection. Instead of three separate connections
for temperature, draft, and flue gases, it now has just one simple
connection. This new design allows users to connect the probe
easily without the need to look, thanks to its plug-n-play
design.

For more information, please contact Seitron Americas at phone
215-660-9777 or visit their website at www.seitronamericas.com.

INDUSTRIAL COMBUSTION & EMISSIONS ANALYZERS

Industrial Emissions Analysis Range
Our dedicated team is always on the forefront of designing and manufacturing the most suitable, custom and innovative instruments to match almost every industrial application. Standards regulating exhaust gas emissions in industrial systems are also becoming more strict, being of great relevance for both climate and health protection. In high intensity processes, great quantities of toxic gases are produced, such as carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOX), sulfur dioxide (SO2) amongst others. Often performed in extreme environments, featuring high levels of humidity, high temperatures and presence of particulate matter coming from combustion gases, accurate emissions measurements are needed in order to verify the quality, efficiency and safety of the process. The analysis are typically performed by special laboratories, maintenance technicians of industrial plants or by the industries themselves. In order to answer these needs, Seitron has developed a line of industrial emissions analyzers, either portable for periodical measurements or fixed for continuous emissions monitoring.

2

phone 215-660-9777 – www.seitronamericas.com

Applications

INDUSTRIAL EMISSIONS ANALYZERS

Chemical Industries

Boilers

Industrial Burners

Cement

Gas & Diesel Engine

Mining

Laboratories

Biogas Factories

phone 215-660-9777 – www.seitronamericas.com

3

Industrial
Emissions Analyzers Selection Guide

PARAMETERS

of gases 02 Long Life, 0 – 25.0% CO, 0 – 8,000 ppm Calculated CO2 CO2 Sensor

for Direct Measurement (0 .. 50%) Automatic CO Dilution Auto-Range NO Sensor, 0 – 5,000 ppm NO2 Sensor, 0 – 1,000 ppm SO2 Sensor, 0 – 5,000 ppm Low NO, NO2, SO2 Sensor, 0 – 100.0 ppm CxHy (HC) Pellistor, 0 – 5% vol CH4 H2S Sensor (standard or low range) H2 Sensor, 0 – 2,000 ppm NH3 Sensor, 0 – 500.0 ppm CH4 NDIR Sensor, 0 – 100% v/v

Novo 2-4

Optional Optional Optional Optional Optional Optional Optional

Novo-P 2-4

Optional Optional Optional Optional Optional Optional Optional

S6000 5 or 6
Optional Optional Optional Optional Optional Optional Optional Optional

FEATURES BUILT-IN Printer (NON-FADING PAPER) Wireless Bluetooth Printer FIELD- REPLACEABLE Pre-Calibrated Sensors Reporting & Storage Software with Bluetooth Real-Time Software & Data Logging Internal Memory Automatic Data Logging External Cooler Draft / Differential Pressure Gas Velocity

Optional

100,000 Tests

100,000 Tests

Optional

Optional

2,000 Tests
Optional

4

phone 215-660-9777 – www.seitronamericas.com

INDUSTRIAL EMISSIONS ANALYZERS

PARAMETERS # of gases Heated Hose & Probe Head Continuous 24/7 Measurement 02 Long Life, 0 – 25.0% CO, 0 – 8,000 ppm Calculated CO2 CO2 Sensor for Direct Measurement (0 .. 50%) Automatic CO Dilution Auto-Range NO Sensor, 0 – 5,000 ppm NO2 Sensor, 0 – 1,000 ppm SO2 Sensor, 0 – 5,000 ppm Low NOx / SO2 Sensor, 0 – 500.0 ppm CxHy (HC) Pellistor, 0 – 5% vol CH4 H2S Sensor (standard or low range) H2 Sensor, 0 – 2,000 ppm NH3 Sensor, 0 – 500.0 ppm NDIR Bench configured for one or more gases of the following: CO2 (0 – 50%), CO (0 -15%) & HC (calibrated for CH4 or C3H3)
FEATURES Calculated CO2, Efficiency, & Excess Air BUILT-IN Printer (NON-FADING PAPER) Wireless Bluetooth Printer FIELD-REPLACEABLE Pre-Calibrated Sensors Reporting & Storage Software with Bluetooth Real-Time Software & Data Logging
Internal Memory
Automatic Data Logging Built-In Thermo-Electric Peltier Chiller Draft / Differential Pressure Gas Velocity

S9000 up to 12 Optional

Optional
Optional Optional Optional Optional Optional Optional Optional Optional

16,000 Tests
Optional

S9000-RACK up to 6 Optional
Optional
Optional Optional Optional Optional Optional Optional Optional Optional
Optional
Data saved via Modbus® on PC

phone 215-660-9777 – www.seitronamericas.com

5

Novo Series
Combustion Analyzers Selection Guide

PARAMETERS

of Gases O2 Long-Life (4 years) CO2, (Calculated from O2), 0 – 100% CO

Measurement w/NOx filter, 0 – 8000 ppm CO Over Range Protection 0 – 100,000 ppm NO/NOx included 0 – 5,000 ppm Low-NOx Capable 0 – 500.0 ppm TOTAL NOx (NO

  • NO2 lncluded) Ambient Temperature Measurement Stack Temperature Measurement Differential Pressure Manometer Draft Measurement Excess Air Calculation Ambient CO Monitor Simultaneous Measurement of Combustion + Pressure Capable of measuring NO2, SO2, CxHy, H2S, H2, NH3, Direct CO2 High Altitude Adjustment

Novo 1 2-4

Novo 1-P 2-4

Novo 3 3

Novo 3-P 3

Novo 4 4

Novo 4-P 4

FEATURES
Built-ln Printer (Non-Fading Paper) Wireless Bluetooth® Printer FIELD- REPLACEABLE Pre-Calibrated Sensors Mobile App + QR code PC Software Automatic data Logging Combustion Efficiency Measurements for All Atmospheric & Condensing Systems Rechargeable Battery w/ AC Charger Display Screen Carrying Case

Optional

Optional

Optional

Optional

Optional

Optional

7″ Touch Hard

7″ Touch Hard

7″ Touch Hard

7″ Touch Hard

7″ Touch Hard

7″ Touch Hard

6

phone 215-660-9777 – www.seitronamericas.com

COMBUSTION ANALYZERS
7“ Responsive Touch Screen The new device has been redesigned to give the user an improved and easy-to-use experience. The analyzer includes a large 7″ touchscreen, granting maximum visibility of all information along with quick and smooth browsing experience.
Simple ONE Probe Connection One source of major improvement of our analyzer is the new, innovative flue gas sampling probe connection. Instead of three (3) separate connections for temperature, draft and flue gases, it has been redesigned to just one (1) simple connection. The new connection allows the user to connect the probe without looking with an easy plug-n-play design.
Combustion parameters and gas pressures Thanks to the possibility of measuring combustion parameters and gas pressures at the same time, Novo drastically reduces service time and limits the need to use different devices.

phone 215-660-9777 – www.seitronamericas.com

7

Built-in printer Field Replaceable Sensors

Novo
ALL-IN-ONE COMBUSTION ANALYZER
Fast / Easy / Robust / Accurate
· 7″ Touch Screen for easy menu navigation · Optional Built-in Printer · Long Life O2 Sensor (4 Years) · New Dual Range (Low/High) Sensor Technology · Low NOx and SOx sensors · 15 Preprogrammed Fuels · Including Natural Gas, Oil, Propane, & Biofuels · CO Protection Dilution Pump · Rechargeable Li-Ion Batteries · Integrated water trap with LED backlight for easy
maintenance · Differential Pressure Manometer · Simultaneous Gas Pressure + Combustion
Measurements · Cracked Heat Exchanger Test · Draft Measurement · Mobile App for iOS and Android

Up to 4 gases 7″ Touch Color Display

Seitron Smart Analysis

Mobile App – iOS, Android

Simultaneous Gas Preassure + Combustion

Windows Software Seitron Smart Analysis

8

phone 215-660-9777 – www.seitronamericas.com

COMBUSTION ANALYZERS

MEASUREMENT O2 Long life
CO sensor with Over Range protection (NOx filter) – Dual Range

SENSOR Electrochemical
Electrochemical

RANGE 0 .. 25.0% vol
0 .. 500 ppm 501 .. 8000 ppm

RESOLUTION 0.1% vol
0.1ppm

±0.2% vol ±2 ppm ±5% measured value

ACCURACY
0 .. 40.0 ppm 40.1 .. 500.0 ppm

1 ppm

±5% measured value ±10% measured value

501 .. 2000 ppm 2001 .. 8000 ppm

CO Mid

Electrochemical 0…20000 ppm

1 ppm

±10 ppm ±5% v.m. ±10% v.m.

0 .. 200 ppm 201 .. 4000 ppm 4001 .. 20000 ppm

CO High
NO
NO2
SO2
H2 H2 High H2S H2S Low NH3 Low CxHy CH4 NIDR CO2 NDIR CO2 NOx Air Temperature Stack Temperature
Pressure (draft & differential)
Differential Temperature Air Index Excess Air Stack losses Efficiency Warranty

Electrochemical 0…100000 ppm

1 ppm

±100 ppm ±10% v.m.

Electrochemical

0…500.0 ppm

0.1 ppm

±2 ppm ±5% v.m.

501…5000 ppm

1 ppm

±10% v.m.

Electrochemical

0…100.0 ppm

0.1 ppm

±2 ppm ±5% v.m.

101…1000 ppm

1 ppm

±10% v.m.

Electrochemical

0…500.0 ppm

0.1 ppm

±2 ppm ±5% v.m.

501…5000 ppm

1 ppm

±10% v.m.

Electrochemical Sensor

0…2000 ppm

1 ppm

± 10 ppm ± 10% v.m.

Electrochemical Sensor

0…40000 ppm

10 ppm

± 100 ppm ± 10% v.m.

Electrochemical Sensor

0…5000 ppm

1 ppm

± 10 ppm ± 10% v.m.

Electrochemical Sensor

0…500.0 ppm

0.1 ppm

±5 ppm ±5% v.m.

Electrochemical Sensor

0…500.0 ppm

0.1 ppm

±10 ppm ±10% v.m.

Pellistore Sensor 0..5% vol CH4

0.01% vol

±0.25% abs

NDIR Sensor

0..100% vol

0.01% vol

±0.3 vol ±10% v.m.

NDIR Sensor

0..50% vol

0.01% vol

±1 vol ±2% fs

Calculated

0 .. 99.9% vol

0.1% vol

Calculated

TcK sensor

-4.0 .. 2282.0 °F -20.0 .. 1250.0 °C

32.18 °F 0.1 °C

±0.5 °C ±0.5%

TcK sensor

-4.0 .. 2282.0 °F -20.0 .. 1250.0 °C

32.18 °F 0.1 °C

±0.5 °C ±0.5%

Piezo Resistive

-40.1 .. +80.4 inH2O

0.004 inH2O

±1% measured value
±0.08 inH2O ±1% measured value

Calculated

32.0 .. 2282.0 °F 0 .. 1250.0 °C

33.8 °F 0.1 °C

Calculated

0.00 .. 9.50

0.01

Calculated

0 .. 850 %

1%

Calculated

0.0 .. 100.0 %

0.1 %

Calculated

0.0 .. 100.0 %

0.1 %

4 years on O2 Sensors and 2 years on Analyzer, CO Sensor, Probe

0 .. 1000 ppm 1001 .. 100000 ppm 0 .. 40 ppm 40.1 .. 500.1 ppm 501 .. 5000 ppm 0 .. 40 ppm 40.1 .. 100.1 ppm 101 .. 1000 ppm 0 .. 40 ppm 40.1 .. 500.1 ppm 501 .. 5000 ppm 0 ppm – 100 ppm 101 ppm – 2000 ppm 0 ppm – 1000 ppm 1001 ppm – 40000 ppm 0 ppm – 100 ppm 101 ppm – 5000 ppm 0 .. 100.0 ppm 101 .. 500.0 ppm 0 .. 100.0 ppm 100.1 .. 500.0 ppm
0 .. 10% vol 10.01% .. 100.00% vol 0 .. 10.00% vol 10.01% .. 50.00% vol
32 .. 212 °F (0 .. 100 °C) 213.8 .. 2282.0°F (101 .. 1250 °C) 32 .. 212 °F (0 .. 100 °C) 213.8 .. 2282.0°F (101 .. 1250 °C) -40.1 .. -0.81 inH2O -0.80 .. +0.80 inH2O +0.81 .. +80.4 inH2O

phone 215-660-9777 – www.seitronamericas.com

9

Novo Kits Include:
· Combustion Analyzer · Gas probe with 12″ (300 mm) interchangeable tip · 10 ft (3m) Single Connection Hose · Integrated water trap · Manometer Hoses · Outdoor Combustion Air Temp Probe · AC Power Adapter & Cable · Hard plastic kit case · Quick Guide
· Calibration Certificate

Features:
· Built-in Printer
· CO Air Free
· Altitude Adjustment · Field Replaceable Sensors · Combustion Efficiency, Losses, Excess Air · CO sensor protection · Draft & Differential Pressure · Temperature Measurements · 7″ Color Touch Screen · Bluetooth Connectivity · Long Lasting Rechargeable Battery & AC Charger · Gas Sampling Probe & Hose

Model Novo 1 Novo 1-P Novo 3 Novo 3-P Novo 4S Novo 4S-P Novo 4N Novo 4N-P Novo 4C Novo 4C-P
10

Description
Analyzer w/ O2, CO, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included
All In One Kit with BUILT-IN Printer. Analyzer w/ O2, CO, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe

  • iOS and Android App included. Bult-in Printer included.
    Analyzer w/ O2, CO, NO/NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    All In One Kit with BUILT-IN Printer. Analyzer w/ O2, CO, NO/NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    Analyzer w/ O2, CO, NO, SO2, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    All In One Kit with BUILT-IN Printer. Analyzer w/ O2, CO, NO, SO2, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    Analyzer w/ O2, CO, NO, NO2, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    All In One Kit with BUILT-IN Printer. Analyzer w/ O2, CO, NO, NO2, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    Analyzer w/ O2, CO, NO, CxHy, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    All In One Kit with BUILT-IN Printer. Analyzer w/ O2, CO, NO, CxHy, Total NOx, CO2, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 12″ (300mm) Probe with 10 ft (3 m) Hose, Hard Case, Calibration Certificate, Operating Manual, Cheat Sheet, Integrated Water Trap, Data Storage, PC Software, Bluetooth, Differential Pressure Manometer Kit, Outdoor Air Temperature Probe + iOS and Android App included.
    phone 215-660-9777 – www.seitronamericas.com

Sample Conditioning Units: PASSIVE and ACTIVE solution
Applications: – Ideal for Emissions Compliance Testing – Low NOx Boilers, Burners, Engines, Furnaces, etc. – High Accuracy Measurements of NO, NO2, SO2, H2S, & NH3 – Long-Term Analysis (30+ min continuous) – Ideal for Flue Gas with High Moisture Content
Part # AASCU01 – PASSIVE Sample Conditioning Unit

COMBUSTION ANALYZERS

Part # AACE01 – ACTIVE Sample Conditioning System with Thermoelectric Cooler

Features: – Integrated Thermoelectric Peltier Cooler – Rapid Cooling and Drying of Flue Gas Samples – Compatible with All Portable Seitron Gas Analyzers – Automatic Condensate Drain Pump – Protective Hard Plastic Carrying Case – Connect to AC Power or Optional Portable DC Charger

Compatible with:

AASF31 AASF62 AASF65 AASF66

7″ gas probe, with 10 ft cable. Working temperature: 752°F (400°C) 12″ gas probe, with 10 ft cable. Working temperature: 1112°F (600°C) 30″ gas probe, with 10 ft cable. Working temperature: 1472°F (400°C) 40″ gas probe, with 10 ft cable. Working temperature: 2192°F (400°C)

REMOTE WATER DRAIN
TO INSTRUMENT “IN” INPUT
WATER TRAP +
FILTER TO INSTRUMENT
“P-” INPUT
TO INSTRUMENT “T1″ INPUT

CONNECT TO THE MAINS VOLTAGE 110-240V~ VIA THE SUPPLIED CABLE
GAS SAMPLING PROBE

phone 215-660-9777 – www.seitronamericas.com

11

S6000
INDUSTRIAL / COMMERCIAL EMISSIONS ANALYZER
Fast / Easy / Robust / Accurate
· Built In Printer · Up to 6 gas (O2 , CO, NO, NH3 , NO2 , CO2, SO2, CxHy (HC), H2,
H2S, CH4) · NOx & SOx in one Instrument · Low NOx & Low SOx Capable · True NOx (Low NO+NO2) Available · Automatic data logging · Diluition pump for CO Auto range up to 100,000 ppm · Smartphone Real Time + QRcode App (iOS, Android) · Built in Manometer · Draft/Pressure included · PC Software Included · New Ammonia (NH3) and Hydrogen (H2) Measurement

Built-in Printer

Seitron Smart Analysis

Field Replaceable Sensors

Up to 6 Gas Sensors

Windows Software Seitron Smart Analysis

Full Color Graphic Display Mobile App – iOS, Android

Features · Draft & Differential Pressure · Temperature Measurements · Large Color Display · 2000 Test Internal Memory · Bluetooth Connectivity · Long Lasting Rechargeable Battery & AC Charger · Gas Sampling Probe & Hose · Gas velocity w/optional Pitot tube · Longer probes: extension hoses available

12

phone 215-660-9777 – www.seitronamericas.com

INDUSTRIAL EMISSIONS ANALYZERS

MEASUREMENT

SENSOR

RANGE

RESOLUTION

ACCURACY

O2 Long life
CO sensor w/ Over Range protection
NOx filter
CO2 H2 Low NO Standard NO Low NO2 Standard NO2 Low SO2 Standard SO2 NOx NH3 CxHy (HC) Air Temperature Gas Temperature Differential temperature
Pressure/Draft
Excess air Efficiency Warranty

Electrochemical
Electrochemical
Calculated Electrochemical Electrochemical
Electrochemical
Electrochemical Calculated
Electrochemical Pellistor Pt100 TcK Calculated

0 .. 25.0% vol 0 .. 500 ppm
501 .. 8000 ppm 0 .. 99.9% vol 0 .. 2000 ppm 0 .. 500 ppm
501 .. 5000 ppm 0 .. 500 ppm
501 .. 1000 ppm 0 .. 500 ppm
501 .. 5000 ppm –
0 .. 500.0 ppm 0 .. 5%
– 4 to 248 °F – 20 to 120 °C – 4 to 2280 °F – 20 to 1250 °C – 4 to 2280 °F – 20 to 1250 °C

0.1% vol 0.1ppm
1 ppm 0.1% vol 1 ppm 0.1ppm
1 ppm 0.1ppm
1 ppm 0.1ppm
1 ppm –
0.1 ppm 0.01 % 33.8 °F 32.2°F (0.1 °C) 33.8 °F 32.2°F (0.1 °C) 32.2°F (0.1 °C)

Piezo Resistive

-40.1 .. +80.4 inH2O

0.004 inH2O

Calculated

0 .. 850%

1%

Calculated

0 .. 100%

0.1%

2 years on Sensors and 2 years on Analyzer

±0.2% vol
±2 ppm ±5% measured value

0 .. 40.0 ppm 40.1 .. 500.0 ppm

±5% measured value ±10% measured value

± 10 ppm 0 ppm – 100 ppm ±2 ppm ±5% measured value

501 .. 2000 ppm 2001 .. 8000 ppm
± 10 % 100 ppm – 2000 ppm
0 .. 40.0 ppm 40.1 .. 500.0 ppm

±5% measured value ±2 ppm ±5% measured value

501 .. 5000 ppm 0 .. 40.0 ppm 40.1 .. 500.0 ppm

±5% measured value ±2 ppm ±5% measured value

501 .. 1000 ppm 0 .. 40.0 ppm 40.1 .. 500.0 ppm

±5% measured value

±10 ppm ±10%
±5% full scale
33.8 °F 32.2°F (0.1 °C) 33.8 °F 32.2°F (0.1 °C)

501 .. 5000 ppm
0 .. 100.0 ppm 100.1 .. 500.0 ppm

±1% measured value ±0.08 inH2O ±1% measured value

-40.1 .. -0.81 inH2O -0.80 .. +0.80 inH2O +0.81 .. +80.4 inH2O

Model

Description

Standard Probe Detail: · 12″ (300mm) probe · 1112 °F (600 °C) max · 10′ (3m) Dual Hose Long Probe Detail: · 30″ (750mm) probe · 1472 °F (800 °C) max · 10′ (3m) Dual Hose Extra Long & High Temp Probe Detail: · 40″ (1m) Probe or 60″ (1.5m) probe · 2192 °F (1200 °C) max · 10′ (3m) Hose Hose Extention: · 10′ (3m) Length Available

SOFTWARE Windows
· Remote display of real-time analysis from the portable analyzer and data saving
· Display and/or export and stored data · Analyzer configuration

E6000-5DS

O2, CO, NO/NOx, NO2 & SO2 Gas Sensors

E6000-5DC

O2, CO, NO/NOx, NO2 & CxHy/HC Gas Sensors

E6000-5SC

O2, CO, NO/NOx, SO2 & CxHy/HC Gas Sensors

E6000-5SH

O2, CO, NO/NOx, SO2 & H2S Gas Sensors

E6000-6DSC O2, CO, NO/NOx, NO2, SO2 & CxHy/HC Gas Sensors

E6000-6DSH O2, CO, NO/NOx, NO2, SO2 & H2S Gas Sensors

(*) All models above are available also with: Low NO, Low NO2, Low SO2 – (**) Ammonia (NH3) Available upon request on any Model

phone 215-660-9777 – www.seitronamericas.com

13

S9000
TRANSPORTABLE EMISSIONS ANALYZER
UP TO 12 GAS SENSORS
· Ability to simultaneously measure up to 12 different gases, with up to 9 single gas measuring sensors and one infrared bench (NDIR) for High CO, Direct CO2 & Hydrocarbons (HC)
· Measurable gases: O2, CO, CO2, CxHy, NO, NO2, SO2, H2S, H2, NH3 with different ranges and accuracies
· Selectable Fuels: methane, LPG, propane, butane, light oil, heavy oil, biogas, wood, pellets, natural gas, coal. Up to 16 additional fuels can be added by the user
· Pump for gas sample and 2nd dilution pump for CO cell protection
· Withstand very high stack temperatures · Double particulate filter system · Standard expansion water trap or Peltier quick Cooler · Automatic condensate drainage with peristaltic pump · Power supply from Lithium Ions Batteries or mains 90…260 Vac · Datalogger function · Industrial Grade Metal Case

Built-in Printer

Field Replaceable Sensors

Windows Software Seitron Smart Analysis

Up to 9 Gas Sensors + 3 Gas Senosrs (NDIR Bench)
Full Color Graphic Display
PC Software included
Optional: Heated Line and Probe

Features · Real-time data logging PC Software included · Built in Thermometric Chiller with auto Condensate
Drain · Large Color Display · 16000 Test Internal Memory · Bluetooth Connectivity · Gas Sampling Probe & Hose · Heated probe and head available · Positive, negative and Pressure Differential
measurement · AC Charger / power supply · Gas sampling probes of different type and length

14

phone 215-660-9777 – www.seitronamericas.com

S9000 – FEATURES
Windows Software Seitron Smart Analysis
· Data Storage · Remote display of real-time analysis from the analyzer · Display and/or export and stored data · Analyzer configuration

· Heated Lines/Probe

Application

· Built In Thermoelectric Chiller with Auto Condensate Drain

· Customizable of Gas Sensors/probes for any Industrial application: O2, CO Low, CO High, NOx, Low NOx, SO2, Low SO2, H2S, CO2, High CO, H2 and now with NH3!

phone 215-660-9777 – www.seitronamericas.com

15

S9000 – TECHNICAL FEATURES

Power supply:
Battery charge: Charging time: Instrument battery life:
Display:
Connectivity Communication port: Bluetooth:
Autozero: Dilution:
Gas measurement sensors: Infrared bench: Fuel type:
Self diagnostics: Temperature measurement:
Ambient temperature measurement:
Printer: Printer power supply: Printer battery life:
Internal Data Memory:
In-line filter:
Vacuum pump: Capacity pump:
Cooler sample treatment Drying system: Type: Set point temperature cooler: Max. temp. deviation from set point: Condensate emptying pump: Peristaltic duty cycle pump: Warm-up time: Operating temperature:

100 .. 260V~, or Li-ion battery pack with internal protection circuit, rechargeable. 8 hours from 0% to 90%. 10 hours of continuous operation (except printer and Peltier Chiller). 2 hours with Cooler running.
Backlit TFT graphical color display. 4.3″ 480×272 pixel.
TYPE B USB connector. Communication distance: <100 metres (open field).
Automatic autozero cycle with gas sampling probe in stack. CO sensor measurement range expansion system up to 100,000ppm (10.00%). Up to 9, configurable among electrochemical, NDIR (single cell) and Pellistor. 3 gases NDIR bench: CO, CO2, CxHy. 12 preprogrammed and 16 additional programmable by the user.
Check all functions and internal sensors with status indication. TcK double input with mini connector (ASTM E 1684-96) for Temperature Differential measurement (supply and return).
Via internal sensor or via T2 TcK input with remote sensor.
Integrated, thermal, with easy paper loading and paper level indicator. Analyzer batteries. With fully charged batteries up to 40 analysis reports.
16,000 complete data analysis, time and customer’s name can be stored. With replaceable cartridge, 99% efficiency with 20µm particles. 2.0 l/min flow rate in the stack up to 120inH2O (300hPa) head. Internal sensor measuring pump flow rate.
Rapid water condensation using cyclone system Peltier cell +41°F (+5°C) +50°F (+10°C) from set point
Peristaltic hose 38 ml/min 30s On .. 30s Off ~ 15 .. 20 minutes 23°F (-5°C) .. 113°F (113°F / 45°C)

Anti-condensation trap Type: Condensate emptying pump: Operating temperature: Working temperature: Storage temperature: Humidity limit: Protection level: External dimensions:
Weight:
16

Integrated Peristaltic hose 38 ml/min 23°F (-5°C) .. 113°F (45°C)
23°F (-5°C) .. 113°F (45°C) -4°F (-20°C) .. 122°F (50°C) 20% .. 80% RH IP21 20″ x 14″ x 8″ (50 x 36 x 20 cm) (W x H x D). 20″ x 18″ x 5″ (50 x 46 x 13 cm) (W x H x D) with intermediate drawer for heated head and sensor transportation. ~ 26.5 lb (12kg) (Typical configuration: nine sensors – Cooler – IR bench – smoke sampling sensor – power cable – USB cable – carrying strap – two paper rolls – USB stick – condensate drain tube – remote air intake tube – combustive air sensor). ~ 28.6 lb (13kg) (Typical configuration with additional accessories such as: 3m extension for smoke sensor – auxiliary air sensor – 12″ (300mm) Pitot Tube – draught gauge). ~ 36.8 lb (16.7kg) (Typical configuration with additional accessories and intermediate drawer containing: heated head sensor with 12″ (300mm) tip and heated tube).
phone 215-660-9777 – www.seitronamericas.com

· Emissions Measurements · Thermoelectric Chiller with Automatic Condensate Drain · Built-In Printer · New iOS & Android App (Remote Display & QR Scanning) · CO2: Direct CO2 measurement and/or % Calculation · Low Ranges available for most sensors · True NOx Measurement · Combustion Efficiency, Losses, & Excess Air Calculations · Draft & Differential Pressure · Temperature Measurements · Large Color Display · 16,000 Test Internal Memory · Bluetooth Connectivity · Rechargeable Battery Pack & AC Charger · Gas Sampling Probe & Hose · PC Software & USB Cable · Operating Manual · Calibration Certificate · Aluminum Carrying Case
TABLE A (Gas Sensor Options ­ Choose up to 8)
O O2 Sensor (0 .. 25.0% vol) Included with standard kit C Standard CO Sensor w/ H2 Compensation (0-8000 ppm)
CL LOW-Range CO Sensor (0-500 ppm)
CM MID-Range CO Sensor (0-20,000 ppm)
CH HIGH-Range CO Sensor (0-100,000 ppm)
N Standard NO/NOx Sensor (0-5000 ppm)
NL LOW NO/NOx Sensor (0-500 ppm)
D Standard NO2 Sensor (0-1000 ppm)
DL LOW NO2 Sensor (0-500 ppm)
S Standard SO2 Sensor (0-5000 ppm)
SL LOW SO2 Sensor (0-500 ppm)
H Standard H2S Sensor (0-5000 ppm)
HL LOW H2S Sensor (0-500 ppm)
G H2 Sensor (0-2000 ppm)
C Standard CxHy Sensor (0-5 %)
A Standard Ammonia (NH3) Sensor (0-500 ppm)
TABLE B (NDIR Bench Options)
IR* CO2 NDIR Sensor (0-50%), CxHy NDIR Sensor (0100,000ppm), and High CO NDIR Sensor (0-50%)
O No IR Bench Included

  • IR Bench counts as 3 gas sensors

ORDERING CODE:

Model # S9000-A-B-C

Description Standard S9000 Kit Configuration with O2 sensor and 12″ probe as standard

Example: S9000-OCNL-IR-12H = O2, Standard CO, Low Range NO, IR Bench (CO2, CxHy & High CO), with 12″ Heated Line & Probe

TABLE C – Probe Options

12

12″ (300mm) Probe, 1112F (600C) max, with 10′

(3m) Included With Standard Kit

30

30″ (750mm) Probe, 1470F (800C) max, with 10′

(3m) Dual Hose (AASF35)

40

40″ (1000mm) Probe, 1470F (800C) max, with 10′

(3m) Dual Hose (AASF36)

12H 12″ (300mm) Probe, 1112F (600C) max, with 10′ (3m) HEATED Hose and HEATED Probe Head (AASR03)

40H 40″ (1m) Probe, 2190F (1200C) max, with 10′ (3m) HEATED Hose and HEATED Probe Head (AASR04)

OPTIONAL – Accessories and Consumable Parts

AARC10 AAFS02 AAFS01 AATTA03
AACEX02S WFILA0001 WFILX0016
AAFA04 AASP01 AAEB01 AATY01 AACSA04

Non-Fading Paper Roll (pack of 10) Sintered Filter with Support for probe Replacement Inox filter for AASF02 36″ (900mm) Pitot Tube for Gas Velocity Measurements 10′ (3m) Dual Hose Extension Particulate Filter (Internal) Particulate Filter (External) Anti-Dust filter (2pcs), only with NH3 installed Heat Protection Shield for probes Trunk Extension Trunk Trolley 4″ (100mm) Auxiliary Temperature Probe w/ 10ft (3m) hose

phone 215-660-9777 – www.seitronamericas.com

17

S9000-RACK
CONTINUOUS EMISSIONS GAS ANALYZER
UP TO 6 GAS SENSORS
· Serial communication port type RS485 according to protocol MODBUS® RTU USB Communication
· 4 .. 20 mA isolated output · Output signal: from 4 to 20mA scalable up to 10% of
the measurement range of the chosen sensor. Other calibrations beyond this limit on request · 4 alarm relays outputs · Heated probes available up to 20 ft (6m) connection · Efficiency calculations · Condensing efficiency calculation · PCI efficiency calculation · PCS efficiency calculation · 15 default fuels · 32 programmable fuels · CO sensor protected by an automatic dilution system

Continuous Analysis
Field Replaceable Sensors Up to 3 Gas Sensors
+ 3 Gas Sensors (NDIR Bench) Full Color Graphic Display
PC Software included Optional: Heated Line and Probe

Windows Software Seitron Smart Analysis
Features · up to 6 gas sensors in total · NDIR bench (measuring up to 3 gases) · Electrochemical gas measurement sensors (up to 3) · Stack temperature measurement (2 temperatures) · Ambient or Primary Air Source Temperature · Thermal Compensation · Draft in the stack with automatic autozero · Measurement of the differential pressure · Stack Air Velocity measurement with the use of Pitot tube · Suction pump flow rate measurement

18

phone 215-660-9777 – www.seitronamericas.com

SAMPLING LINE SELECTION SYSTEM
RELAY 3

RELAY 4

SAMPLING L1 / L2
STACK T° L1 STACK T° L2

USB
PC RS485
PLC
S9000-RACK FEATURES
Windows Software Seitron Smart Analysis
· Data Storage · Remote display of real-time analysis from the analyzer · Display and/or export and stored data · Analyzer configuration

SAMPLING L1 SAMPLING L2

· Serial communication port type RS485 according to protocol MODBUS RTU USB communication · Customizable Gas Sensor/probe configurations for any Industrial application:
O2, CO Low, CO High, NOx, Low NOx, SO2, Low SO2, H2S, CO2, High CO, H2 and now with NH3!)
· Built In Thermoelectric Chiller with Auto Condensate Drain
· Heated Lines/Probes

phone 215-660-9777 – www.seitronamericas.com

19

S9000-RACK TECHNICAL FEATURES

Power supply Power absorption at 230 V Display PC Communication port Connectivity Autozero Internal Sampling pump Line Filters Sample treatment
Size Operation temperature Stock temperature Alarm relay Protection fuses Analog Outputs Gas 1, Gas 2 Output Connector Gas Input Connector Pressure P1, P2 Input Connector Condensate drainage Output Connector Air Connector Compliant with European Standards Compliant with USA Standard

90 .. 264 Vac 100 VA TFT 4.3″, 272 x 480 pixels graphic color with backlight USB Connector type A USB-RS485 MODBUS RTU Automatic autozero cycle with the probe inserted in the chimney 2.2 l/min head at the stack up to 300 hPa. Replaceable cartridge, 95% efficiency with 20um particles Peltier cooling system with automatic emptying of the condensation water 19” /4 HE / 400 mm 32°F .. 113°F (+0°C .. + 45°C) -4°F .. 140°F (-20°C .. + 60°C) 4 x SPDT AC/DC 24 V 1A 2 x 4A 5 x 20 T 4 x 4-20 mA max resistance load 1 KOhm 1/8 BSPP 1/8 BSPP 1/8 BSPP 1 /8 BSPP – fast connection tube 0.25″ (6mm) diameter 1/8 BSPP EN 50270, EN 50379-1 ed EN 50379-2 CTM030 and CTM034

Standard Equipment
Code
WFUS5X20004R WFILA0001 WFILX0016 WCAV0048 AACCV01 AACCV06 AASW17

Description
4A 5×20 delayed fuse Filtering cartridge for gas line and autozero line Particulate filter grade 7 for IR bench protection USB-A / USB-B adapter cable Power cable US power cable and plug S9000 Smart Analysis PC Software

20

phone 215-660-9777 – www.seitronamericas.com

INDUSTRIAL EMISSIONS ANALYZERS

· Emissions Measurements – Up to 6 total Gas Sensors · Optional NDIR Sensor Bench ­ Includes CO2, High CO, &
CxHy Hydrocarbons (3 sensors) · Thermoelectric Chiller with Automatic Condensate Drain · Serial communication port type RS485 according to protocol
MODBUS® RTU USB Communication · 4 .. 20 mA isolated output (4 configurable channels ­ active loop) · Four alarm relays outputs SPDT, AC/DC 24V 1A. · Data saved via Modbus® on PC · Real-Time Data Logging Software · Stack and Ambient Air Temperature Measurements · Differential Pressure Measurement · Stack Gas Velocity Measurement (with optional pitot tube)
Included: filters, power cable, calibration certificate, Seitron Smart Analysis PC software and mobile App
TABLE A (Gas Sensor Options ­ Choose up to 3)
O O2 Sensor (0 .. 25.0% vol) C Standard CO Sensor w/ H2 Compensation (0-8000 ppm) CL LOW-Range CO Sensor (0-500 ppm) CM MID-Range CO Sensor (0-20,000 ppm) CH HIGH-Range CO Sensor (0-100,000 ppm) N Standard NO/NOx Sensor (0-5000 ppm) NL LOW NO/NOx Sensor (0-500 ppm) D Standard NO2 Sensor (0-1000 ppm) DL LOW NO2 Sensor (0-500 ppm) S Standard SO2 Sensor (0-5000 ppm) SL LOW SO2 Sensor (0-500 ppm) H Standard H2S Sensor (0-5000 ppm) HL LOW H2S Sensor (0-500 ppm) G H2 Sensor (0-2000 ppm) C Standard CxHy Sensor (0-5 %) A Standard Ammonia (NH3) Sensor (0-500 ppm)
TABLE B (NDIR Bench Options)
IR* CO2 NDIR Sensor (0-50%), CxHy NDIR Sensor (0100,000ppm), and High CO NDIR Sensor (0-50%)
O No IR Bench Included

  • IR Bench includes as 3 gas sensors

ORDERING CODE:
Model # S9000-RACK-A-B-C

Description
Standard S9000-RACK Kit Configuration

Example: S9000-RACK-OCNL-IR-12H = O2, Standard CO, Low Range NO, IR Bench (CO2, CxHy & High CO), with 12″ Heated Line & Probe

TABLE C – Probe Options

12

12″ (300mm) Probe, 1112F (600C) max, with 10′

(3m)

30

30″ (750mm) Probe, 1470F (800C) max, with 10′

(3m) Dual Hose (AASF35)

40

40″ (1000mm) Probe, 1470F (800C) max, with 10′

(3m) Dual Hose (AASF36)

12H 12″ (300mm) Probe, 1112F (600C) max, with 10′ (3m) HEATED Hose and HEATED Probe Head (AASR03)

40H 40″ (1m) Probe, 2190F (1200C) max, with 10′ (3m) HEATED Hose and HEATED Probe Head (AASR04)

OPTIONAL – Accessories and Consumable Parts

AARC10 AAFS02 AAFS01 AATTA03
AACEX02S WFILA0001 WFILX0016
AAFA04 AASP01 AACSA04

Non-Fading Paper Roll (pack of 10) Sintered Filter with Support for probe Replacement Inox filter for AASF02 36″ (900mm) Pitot Tube for Gas Velocity Measurements 10′ (3m) Dual Hose Extension Particulate Filter (Internal) Particulate Filter (External) Anti-Dust filter (2pcs), only with NH3 installed Heat Protection Shield for probes 4″ (100mm) Auxiliary Temperature Probe w/ 10ft (3m) hose

phone 215-660-9777 – www.seitronamericas.com

21

Sensors for S9000 & S9000-RACK: Measurement Ranges And Accuracies

MEASUREMENT O2
CO with H2 compensation
CO with active dilution CO Low range with H2 compensation CO Low range with active dilution CO
CO with dilution CO
NH3
NO
NO Low range
NOx
SO2
SO2 Low range
NO2
NO2 Low range
CxHy
H2 H2S
H2S

GAS SENSOR
Electrochemical sensor Electrochemical sensor
Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor
Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor Electrochemical sensor

MEASUREMENT RESOLUTION RANGE

0 .. 25.0% vol

0.1% vol

±0.2% vol

ACCURANCY

0 .. 8000 ppm

1 ppm

0 .. 100000 ppm 100 ppm

±10 ppm 0 .. 200 ppm ±5% measured value 201 .. 2000 ppm ±10% measured value 2001 .. 8000 ppm ±20% measured value

0 .. 500.0 ppm 6.250 ppm

0.1 ppm 10 ppm

±2 ppm 0 .. 40.0 ppm ±5% measured value 40.1 .. 500.0 ppm ±20% measured value

0 .. 20000 ppm

1 ppm

0 .. 250000 ppm 100 ppm

±100 ppm 0 .. 2000 ppm ±5% measured value 2001 .. 4000 ppm ±10% measured value 4001 .. 20000 ppm ±20% measured value

0 .. 100000 ppm 100 ppm

0 .. 5000 ppm

0.1 ppm

0 .. 5000 ppm

1 ppm

0 .. 500.0 ppm

0.1 ppm

±0.02% vol o ±5% m.v. 0 .. 2.00 % ±5% measured value 2.01 .. 10.00 % ±10 ppm 0 .. 100 ppm ±10% measured value 101 .. 500.0 ppm ±5 ppm 0 .. 100 ppm ±5% measured value 101 .. 5000 ppm ±2 ppm 0 .. 40.0 ppm ±5% measured value 40.1 .. 500.0 ppm

0 .. 5000 ppm 0 .. 500.0 ppm 0 .. 1000 ppm 0 .. 500.0 ppm 0 .. 5.00% vol

1 ppm 0.1 ppm 1 ppm 0.1 ppm 0.01% vol

0 .. 2000 ppm 0 .. 500.0 ppm 0 .. 5,000 ppm

1 ppm 0.1 ppm 0.1 ppm 1 ppm

±5 ppm 0 .. 100 ppm ±5% measured value 101 .. 5000 ppm ±2 ppm 0 .. 40.0 ppm ±5% measured value 40.1 .. 500.0 ppm ±5 ppm 0 .. 100 ppm ±5% measured value 101 .. 1000 ppm ±2 ppm 0 .. 40.0 ppm ±5% measured value 40.1 .. 500.0 ppm ±0.25% vol

±10 ppm

0 .. 100 ppm

±10%

100 .. 2000 ppm

±5 ppm 0 .. 100.0 ppm ±5% measured value 100.1 .. 500.0 ppm

±5 ppm 0 .. 100.0 ppm

±5% measured value 100.1 .. 500.0 ppm

±10% measured value 501 .. 5000 ppm

22

phone 215-660-9777 – www.seitronamericas.com

INDUSTRIAL EMISSIONS ANALYZERS

CO2 CO2
CO2 0-50% *

Calculated NDIR sensor
NDIR bench

CO 0..50% *

NDIR bench

HC * referred to methane NDIR bench

HC * referred to propane NDIR bench

Air temperature

TcK sensor

Flue gas temperature TcK sensor

Auxiliary sensor temperature
Pressure (draft and differential)

PT100
Piezoelectric sensor

Temperature Differential
Excess Air
Stack heat losses Efficiency Efficiency (condensation)

Calculated
Calculated Calculated Calculated Calculated

0 .. 99.9% vol 0 .. 50.0% vol
0 .. 50.0% vol

0.1% vol 0.01% vol
0.1% vol

vol 500.000 ppm 100 ppm

0-1.000.000 ppm (100%Vol)

1 ppm

0 .. 100000 ppm 1 ppm

-4 .. 248 °F (-20.0 .. 120.0°C) -4 .. 2282 °F (-20.0 .. 120.0°C)

32.2°F (0.1 °C) 32.2°F (0.1 °C)

-4 .. 392 °F (-20.0 .. 200.0°C) -4 .. 80 inH2O

32.2°F (0.1 °C) 0.004 inH2O

32 .. 2282°F (0 .. 1250.0 °C) 0 .. 850% 0.0 .. 100.0% 0.0 .. 100.0% 0.0 .. 120.0%

32.2°F (0.1 °C)
1% 0.1% 0.1% 0.1%

±1% Vol 0.00 .. 10.00 % ±2% Full-scale 10.01 .. 50.00 %
+/- 0,3% Vol 0,00 .. 8,00% Vol +/- 5% vm 8,01% .. 40,00% Vol +/-10% vm 40,01% .. 50,00% Vol 0-2500 ppm : +/- 50 ppm 2501 -100000 ppm : +/- 3% vm 100001 -250000 ppm : +/- 5% vm +/- 50ppm 0 .. 200 ppm +/- 2% vm 201 .. 50000 ppm +/- 3 % vm 50001 .. 1000000ppm
+/- 10ppm 0 .. 300 ppm +/- 3% vm 301 .. 4000 ppm +/-5% vm 4001 .. 30000 ppm
-30 .. +34 °F (±1°C)

1 ppm 10ppm
10ppm

-30 .. +34 °F (±1°C) 32 .. 212 °F (0 .. 100 °C) ±1% measured value 214 .. 2282 °F (101 .. 1250°C)
-31 .. +33 °F (±0.5°C)

±1% measured value -4 .. -0.81 inH2O

±0.008 inH2O

-0.8 .. +0.8 inH2O

±1% measured value +0.81 .. +80 inH2O

(*): The NDIR bench always measures the 3 gases CO, CO2, HC (ref. to methane CH4 ) or HC (ref. to propane C3H8)

phone 215-660-9777 – www.seitronamericas.com

23

Maintenance and Service

A high-quality, up-to-date and certified instrument in compliance with current standards is essential in carrying out your work in the best possible way, while minimizing liability.
· Gases (O2, CO, CO2, NO, NO2, SO2, CxHy) · Temperature · Pressure · Humidity · Current · Air Flow · Refrigeration Gases

2 4- 48 Hr Turnaround
Services offered: · Calibration · Annual certification · Training · Repairs · Field technical support in real time · Field calibrations

On-Site Services

Calibration/Adjustments

Training

CONTACT INFO

service@seitronamericas.com

Phone 215-660-9777

Fax 215-660-9770

For more information visit Customer Service page: www.seitronamericas.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals