Photonic Universe MWM Series Module Wind Turbine Controller User Manual
- September 4, 2024
- Photonic Universe
Table of Contents
MWM Series Module Wind
Turbine Controller
User Manual Product Model
HCM3000-48-240
Important Safety Warning
Before Using the controller, please read all instructions and cautionary
markings on the unitand this manual. Store the manual where it can easily be
accessed.
This manual includes all safety warnings, installation, and operation guidance
of MWM wind controllers.
➢ Before installing and using this controller, read all instructions and
cautionary markings on the controller and all appropriate sections of this
guide.
➢ Do not use the machine in the place where has flammability and explosive
gas/articles. Beware of flames and sparks.
➢ Please Contact our after-sales person if the machine doesn’t work.
➢ Do not change the electrical components and parts yourself, or we will not
be responsible for the warranty items and related duties.
➢ Please disconnect the AC input and DC output from controller before install
or maintain the machine. Besides, do not touch the controller in 5 mins after
disconnection.
➢ Please install the machine indoor to avoid the rain water enter the
controller inside.
➢ Please keep good ventilation and heat dissipation.
➢ Please install a circuit breaker outside the controller if conditions are
allowed.
➢ Please use copper cable for line connection, and choose the right diameter
of cable according to the actual current.
➢ To avoid a risk of fire and electric shock, make sure the existing wiring is
in good condition and that the wire is connected tightly.
➢ Do not restart the controller immediately when it alarms. Please analyze the
fault reasons and repair them at first.
Basic Information
2.1 Introduction and Features
The MWM series wind power generation controller is the controller which integrates MPPT control and charge and discharge control. The power curve can be set by setting the wind turbine voltage and current, which can ensure the wind turbine work with the best power output all the time.
Features:
➢ Can be applied to grid-tied system, off-grid system and grid-tied energy
storage system. Charge function is optional.
➢ MPPT track point settable
➢ Complete protection function
➢ Electrical components and parts in high quality.
➢ Several functions are optional, such as PV control function, wind speed
measure function, rotational speed control function and temperature
compensation function.
➢ RS232/RS485/RJ45/GPRS optional.
2.2 Product Structure
1 | Battery terminal | 5 | Manual brake switch |
---|---|---|---|
2 | Dump load terminal | 6 | Browse button |
3 | Wind turbine terminal | 7 | LCD display |
4 | Communication device port | 8 | Unload indicator light |
Chart3: Dump Load with different power
Product Installation
3.1 Installation Notes
- The machine should be kept indoors and well ventilated;
- Environment temperature: -20~+40℃; Humidity: <=95%,no condensing
- Altitude should not be more than 4000m (>1000 m derating according to the GB/T3859.2 regulations).
- Avoid using the machine in direct sunlight, sun exposure, rain, humidity, acid fog, and dust.
- The machine can only charge for the battery in the rated voltage range.
- The machine can only be connected to the wind turbine and PV with allowed power and voltage.
3.2 Installation and Wiring
3.2.1 Installation Steps
Chart 4: Installation Overview
3.2.2 Installation Steps
Chart5: Installation Steps
3.2.3 Electrical Connection
Chart 6: System Overview
Please connect those parts according to the order of ①②③, and notice the following items.
- Connect Dump load to the controller terminal “DUMPLOAD” by using copper conductor cable.
- Connect the battery bank to the controller by the terminal which marks “DC Bus”. (do not reversed the connection of positive and negative terminals)
- When wind turbine is still or running in a low speed, connects its output cable to the “WIND INPUT” terminal on the controller.
- Check all the connection to make sure they are connected rightly and tightly.
Operation Interface Introduction
4.1 LCD Display
After the power is connected, the whole screen is in a browsing status. It
shows battery voltage, and can be changed to the following information by
press related buttons.
4.2 LCD Information Define
Name | Icon | Status |
---|---|---|
Wind Turbine | Rotate means wind turbine works normally | |
Brake by hand | ||
Battery | Charging | |
Fully charged. flickering for over voltage, stop flickering when it recover |
from over voltage
| Flickering means over -discharge
Browse button| | Press it to enter next LCD display.
Press it for 5s to enter the brake status
Press it for another 5s to recover charging status.
Dump load indicator light| | Red light is on means the machine is on unload
status or brake status.
The light is off when it works normally.
Trouble Shooting
Fault Type | Description | Possible reasons and solutions |
---|
No display
on LCD| The connection between the battery and the controller is not tight|
Check the wiring, and reconnect it.
DC breaker is not on between battery and controller| Turn on the breaker
Low battery voltage| The system parameters are not matched correctly. Recheck
the label and parameters on the machine.
The battery doesn’t work. Change a new one.
Battery is connected in wrong polarity to battery input terminals.| Need
change the internal fuse in
controller, and reconnect the battery.
No charging| The connection cable between wind turbine and controller is
loose.| Reconnect and fix the cables.
Wind turbine output voltage hasn’t reached the charging voltage,| Check
whether the system voltage is reasonable.
Wind turbine is in “Brake” status| Wait the wind turbine recover if it brakes
automatically.
Press the button for 5s to release the brake status if it brakes by hand.
Battery is already fully charged.| Check if the battery voltage has
reached its output overvoltage.
Technical Parameters
Model | HCM3000-48-240 |
---|---|
Type | Buck |
Wind Turbine Input
Rated input power| 3kW
Rated input voltage| 240V
Input voltage range| 0~320V
Start charge voltage| 60Vdc (factory default,40Vdc~320Vdc settable)
Rated input current| 13A
** Brake by hand| Keep press the button for 5s to unload completely, and
then recover by hand.
Switch “ON” the brake switch
Brake by over current| 13Adc (factory default,0~15A settable)Unload completely
when reached the set current, and recover automatically after working 10mins.
Brake by overvoltage| 320Vdc (Factory default), PWM unload step by step once
reached the set unload voltage, and it will unload completely if the voltage
rise 20Vdc more.
Charge Parameters
Rated battery voltage| 48V
Start unload voltage| 56Vdc (factory default,44Vdc~64Vdc settable)
Complete unload voltage| 58Vdc(factory default, add 2V to the start unload
voltage)
Max. Output current| 63A
General Parameters
Rectifier mode| Uncontrolled rectifier
Display mode| LCD
** Display information| DC output voltage, wind turbine
voltage/current/power.”
For those with charge control function, Battery voltage is showed as well.
Monitoring mode| RS232
* Monitoring Contents| Real-time display: DC output voltage, wind turbine
voltage/current/power. For those with charge control function, Battery voltage
is showed as well.
Parameter setting: Output overvoltage point, wind turbine over current point,
wind turbine start voltage, and wind turbine manual brake button.
Lightning protection| YES
Conversion efficiency| ≥92%
---|---
Static loss| <5W
Ambient temperature| -20℃~+40℃
Humidity| 0~90%, No condensing
Noise| ≤65dB
Cooling mode| Forced air cooling
Installation mode| Wall-mounted
Cover protection class| IP42
Product dimension (WHD)| 360×440×195mm
Product net weight| 15.5kg
Dump load dimension (WH*D)| 400×390×210mm
Dump load net weight| 13kg
Note: Part of parameters can be adjusted according to customer’s specific
demand.**
Warranty
The product shall be in warranty for one year from production. Please take contract as the final one if it has special terms on warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>