BOSCH IR Illuminator 5000 IR Camera Installation Guide
- June 13, 2024
- Bosch
Table of Contents
BOSCH IR Illuminator 5000 IR Camera
Safety
Safety message explanation
Caution!
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate inj
Safety precautions
Caution!
Installation should only be performed by qualified service personnel in
accordance with the National Electrical Code (NEC 800 CEC Section 60) or
applicable local codes.
Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings before operating the device.
– Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
– Take precautions to protect the device from power and lightning surges.
– Operate the device only from the type of power source indicated on the
label.
– Unless qualified, do not attempt to service a damaged device yourself. Refer
all servicing to qualified service personnel.
– Disconnect power supply and arrange for the device to be serviced by
qualified personnel if:
– The power cable/plug is damaged.
– Liquids or foreign bodies have entered the device.
– The device has been exposed to water or extreme environmental conditions.
– The device is faulty despite correct installation/operation.
– The device has fallen from a height, or the housing has been damaged.
– The device performance is noticeably changed.
Installation
Mounting the bracket
Connect the bracket to the illuminator as follows:
-
Ensure that the parts are mounted in the following order:
– Socket head screw
– Lock washer
– Washer
– Illuminator
– Bracket -
Use the supplied socket wrench to secure the bracket on both sides of the illuminator
Changing the beam-angle filter
Insert a beam-angle filter as follows:
-
Insert the supplied tool into the slot and twist. (Use the thick end for the IIR-50xxx0-SR illuminator; use the tapered end for all other illuminators.)
-
Remove the top cover.
-
Peel back the protective foil from the adhesive points.
-
Attach the selected beam-angle filter with the label side up to the adhesive points.
-
Click the top cover back into place.
Connection
Connecting the IIR-50xx0
Power
– To power the illuminator, connect a 12 to 32 VDC or a 24 VAC supply from a
SELV class 2 power supply to wires 5 (+ red) and 6 (- black).
Notice! Make sure the unused wires are not connected to each other
Illuminator masters the camera
To use the light sensor in the illuminator to switch the day/night function of
the camera:
- Connect wires 1 (+ white) and 2 (- yellow) to the alarm input of the camera.
- If required, adjust the Photocell adjust control to determine the switching points of the illuminator.
Camera masters the illuminator
To control illuminator switching from the camera:
- Turn the Photocell adjust control fully counterclockwise.
- Connect a relay output from the camera to wires 3 (- green) and 4 (+ blue).
To adjust the sensitivity (Photocell adjust **1**
):
-
Use a thick flathead screwdriver to remove the protective sealing cap
1
. -
Use a small screwdriver to adjust the internal control:
– To use the remove switching control input, turn the control fully counterclockwise.
(Now the IR LED lights when the green and blue wires are not connected; it does not light when the wires are connected.)
– To set the light level at which the illuminator switches on, turn the control counterclockwise to turn on the illuminator when there is more light; turn it clockwise to turn it on when it is darker. (The factory setting turns on the illuminator at approximately 30 lx and turns it off at approximately 70 lx.) -
Put the protective sealing cap back in place and secure.
To adjust the IR intensity (Power adjust **2**
):
- Use a thick flathead screwdriver to remove the protective sealing cap
**2**
- Using a small screwdriver, turn the internal control counterclockwise to reduce the IR intensity. (The factory default is maximum power.)
- Put the protective sealing cap back in place and secure.
Connecting the NIR-50xx0
Power
To power the illuminator, connect a PoE power supply to the RJ45 connector of
the illuminator.
**Adjustments
**
To adjust the sensitivity (Photocell adjust **1**
):
-
Use a thick flathead screwdriver to remove the protective sealing cap
**1**
). -
Use a small screwdriver to adjust the internal control:
– To use the remove switching control input, turn the control fully counterclockwise.
(Now the IR LED lights when the green and blue wires are not connected; it does not light when the wires are connected.)
– To set the light level at which the illuminator switches on, turn the control counterclockwise to turn on the illuminator when there is more light; turn it clockwise to turn it on when it is darker. (The factory setting turns on the illuminator at approximately 30 lx and turns it off at approximately 70 lx.) -
Put the protective sealing cap back in place and secure.
To adjust the IR intensity (Power adjust **2**
):
- Use a thick flathead screwdriver to remove the protective sealing cap
**2**
. - Using a small screwdriver, turn the internal control counterclockwise to reduce the IR intensity. (The factory default is maximum power.)
- Put the protective sealing cap back in place and secure.
Setting up
To achieve the best results:
- Mount and connect the illuminator as described above.
- Complete the following steps at night and view the results on a monitor.
- Adjust the pan of the illuminator to match the camera’s field of view.
- Loosen the bolts on each side of the unit and adjust the vertical alignment to maximize the results:
– Tilt the unit downwards until the near part of the required field of view is
saturated with light as viewed on the monitor.
– Slowly tilt the unit upwards until the furthest part of the required field
of view is illuminated correctly on the monitor.
Technical data
Optical
Wavelength| 850 nm or 940 nm
IR control| Adjustable IR intensity (10% to 100%)
Day/night switch| Photocell, sensitivity adjustable (20 lx to 70 lx)
Beam angles| 10°, 20°, 30°, 60°, 80°, and 95°
Environmental
Operation Temperature Range| -50 °C to +50 °C (-58 °F to +122 °F)
Protection| IP66
IIR-50850-SR | IIR-50940-SR
Power
Power supply| 12 to 32 VDC or 24 VAC ±10%
Power consumption| 13 W
Mechanical
Housing| Robust anodized aluminum extrusion, black
Front window| Polycarbonate high transmittance (vandal-resistant) with self-
cleaning technology
Mount| Black powder coated stainless steel U-bracket (adjustable with M6
socket-head wrench)
Cable| 3 m (9 ft)
Dimensions (W x H x D)| 110 x 70 x 76 mm (4.33 x 2.76 x 2.99 in)
Bracket dimensions (W x H x D)| 110 x 125 x 35 mm (4.33 x 4.92 x 1.38 in)
Weight| 750 g (1.6 lbs)
Bracket weight| 0.2 kg (0.44 lbs)
IIR-50850-MR | IIR-50940-MR
Power
Power supply| 12 to 32 VDC or 24 VAC ±10%
Power consumption| 26 W
Mechanical
Housing| Robust anodized aluminum extrusion, black
Front window| Polycarbonate high transmittance (vandal-resistant) with self-
cleaning technology
Mount| Black powder coated stainless steel U-bracket (adjustable with M6
socket-head wrench)
Cable| 3 m (9 ft)
Dimensions (W x H x D)| 110 x 115 x 76 mm (4.33 x 4.53 x 2.99 in)
Bracket dimensions (W x H x D)| 110 x 125 x 35 mm (4.33 x 4.92 x 1.38 in)
Weight| 1.06 kg (2.3 lbs)
Bracket weight| 0.2 kg (0.44 lbs)
IIR-50850-LR | IIR-50940-LR
Power
Power supply| 12 to 32 VDC or 24 VAC ±10%
Power consumption| 39 W
Mechanical
Housing| Robust anodized aluminum extrusion, black
Front window| Polycarbonate high transmittance (vandal-resistant) with self-
cleaning technology
Mount| Black powder coated stainless steel U-bracket (adjustable with M6
socket-head wrench)
Cable| 3 m (9 ft)
Dimensions (W x H x D)| 110 x 161 x 76 mm (4.33 x 6.34 x 2.99 in)
Bracket dimensions (W x H x D)| 110 x 125 x 35 mm (4.33 x 4.92 x 1.38 in)
Weight| 1.4 kg (3.1 lbs)
Bracket weight| 0.2 kg (0.44 lbs)
IIR-50850-XR | IIR-50940-XR
Power
Power supply| 12 to 32 VDC or 24 VAC ±10%
Power consumption| 52 W
Mechanical
Housing| Robust anodized aluminum extrusion, black
Front window| Polycarbonate high transmittance (vandal-resistant) with self-
cleaning technology
Mount| Black powder coated stainless steel U-bracket (adjustable with M6
socket-head wrench)
Cable| 3 m (9 ft)
Dimensions (W x H x D)| 110 x 213 x 76 mm (4.33 x 8.39 x 2.99 in)
Bracket dimensions (W x H x D)| 110 x 125 x 35 mm (4.33 x 4.92 x 1.38 in)
Weight| 1.84 kg (4.1 lbs)
Bracket weight| 0.2 kg (0.44 lbs)
NIR-50850-MRP | NIR-50940-MRP
Power
Input voltage| Power-over-Ethernet (48 VDC nominal)
PoE IEEE standard| IEEE 802.3at Compliant (PoE+)
Power consumption| 26 W
Mechanical
Housing| Robust anodized aluminum extrusion, black
Front window| Polycarbonate high transmittance (vandal-resistant) with self-
cleaning technology
Mount| Black powder coated stainless steel U-bracket (adjustable with M6
socket-head wrench)
Cable| 3 m (9 ft)
Dimensions (W x H x D)| 110 x 115 x 76 mm (4.33 x 4.53 x 2.99 in)
Bracket dimensions (W x H x D)| 110 x 125 x 35 mm (4.33 x 4.92 x 1.38 in)
Weight| 1.06 kg (2.3 lbs)
Bracket weight| 0.2 kg (0.44 lbs)
Customer Service
Bosch Security Systems B.V.
Torenallee 49
5617 BA Eindhoven Netherlands
www.boschsecurity.com
© Bosch Security Systems B.V., 2018
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>