REMOTE METER
Model: MT11
INSTRUCTION MANUAL For use with DM series dual battery MPPT solar charge
controllers
Important Safety Instructions
SAVE THESE INSTRUCTIONS:
This manual contains important safety, installation and operating instruction
for the remote meter.
General safety information
- Please inspect the MT11 thoroughly after it is delivered. If there is any damage, document this with photos and contact the shipping company or seller for assistance.
- Please read this manual carefully before installing the product and pay close attention to the safety information.
- Keep the MT11 away from rain, dust, vibrations, corrosive gas and intense electromagnetic interference.
- Do not allow water to enter the remote meter.
- There are no user serviceable parts inside the remote meter. Do not disassemble or attempt to repair it.
- The MT11 is only compatible with DM series charge controllers.
Please confirm before purchase and installation.
Overview
The MT11 remote meter is an accessory which is compatible with the DuoRacer
(DM series) MPPT solar controller. It can monitor the running data and working
status of the controller, set the battery type and temperature units, and
reset the generated energy counter.
Features:
- Automatically identify and display the type, model and relevant parameter data of compatible controllers.
- Real-time display of the operational data and working status of the connected device in digital, graphical and textual forms by a largescreen multifunctional LCD.
- Three touch buttons are quick and easy to operate.
- No need for external power supply. The connected charge controller supplies the power for MT11.
- The meter can browse the controller’s parameters, set the battery type and temperature unit, and reset the generated energy counter.
- Real-time display of fault information of the connected devices.
- Long communication distance via RS485.
Product Components
- Remote meter MT11
- 5m communication cable (Model: CC-RS485-RS485-3.81-4P-500)
- Optional Mounting Frame
Installation
4.1 Mounting Frame (optional accessory, included)
Mechanical parameter | Measurement |
---|---|
Overall dimensions | 114 x 114 x 44.41mm |
Mounting dimensions | 88.6 x 88.6mm |
Terminal | Φ5 |
4.2 Wall installation steps
Step 1: Mark and drill screw holes to match the mounting dimensions of the
base, and insert the plastic expansion bolts.
Step 2: Use four PA4.2×32 self-tapping screws to fix the frame to the wall.
Step 3: Remove the decorative shell.
Step 4: Use four M4×8 pan head screws to mount the MT11 screen onto the frame.
Step 5: Install the decorative shell over the screen.
4.3 Surface mounting steps
Step 1: Mark and cut an appropriately-sized hole in the surface for the cable
and rear of the screen.
Step 2: Mark and drill screw holes based on the mounting dimensions.
Step 3: Remove the decorative shell.
Step 4: Use four M4×8 cross recessed pan head screws with M4 nuts to mount the
MT11 screen onto the surface.
Step 5: Install the decorative shell.
NOTE: Consider the plugging/unplugging space and the length of the cable
during installation to ensure the cable will fit.
Product Features
5.1 Front View LCD display screen
Remote meter operation interface. Refer to chapter 6 for details of display
and operation.
Buttons
The meter buttons include two function buttons and one switch button.
| Press the button| 1. PV array parameters
2. Storage battery parameters
3. Browse the starter battery parameters automatically ( )
---|---|---
| Press the button| 1. Browse the PV array parameters
2. Browse the storage battery parameters
3. Browse the starter battery parameters
Temperature units/Battery type
Press the buttonand hold for 5s
| Press the button| Turn the meter ON
Turn the meter OFF
Press the button and hold for 5s
5.2 Rear View
RS485 communication port
Used to connect to the solar controller which, provides power and data to the
MT11.
Communication cable models
CC-RS485-RS485-3.81-4P-500 (Included, 5m length)
CC-RS485-RS485-3.81-4P-1000 (Optional, 10m length)
CC-RS485-RS485-3.81-4P-2000 (Optional, 20m length)
Pins definition
PIN | Definition |
---|---|
1 | DC5V |
2 | RS-485-B |
3 | RS-485-A |
4 | GND |
Display and Operation
6.1 LCD display
Icon | Instruction | Icon | Instruction |
---|---|---|---|
BATT1 battery capacity level ① 0~12% | BATT2 battery capacity level ① |
0~12%
| BATT1 battery capacity level ① 13%~35%| | BATT2 battery capacity level ①
13%~35%
| BATT1 battery capacity level ① 36%~61%| | BATT2 battery capacity level ①
36%~61%
| BATT1 battery capacity level ① 62%~86%| | BATT2 battery capacity level ①
62%~86%
| BATT1 battery capacity level ① 87%~100%| | BATT2 battery capacity level ①
87%~100%
| Day| | PV array
| Night| | BATT1 charging icon
| Display the parameters of the PV array| | BATT2 charging icon
| Display the parameters of BATT1| | BATT1 temperature parameters
| Display the parameters of BATT2| AES| AES signal icon
| Setting icon| Batt.Type| Battery type icon
| Auto global view sign| Min.| Minimum voltage icon
**| Fault icon| Max.**| Maximum voltage icon
① Battery power capacity is calculated by a linear relationship between the
disconnect voltage and float charging voltage.
6.2 Auto global view mode
Operation:
Step 1: Press the button, will appear.
Step 2: Press the button, select the . The display will now automatically loop
through all parameters.
Display Loop: PV voltage → PV current → PV power→ Battery power → BATT1
voltage → BATT1 current → Max. BATT1 voltage → Min.BATT1 voltage → BATT1
temperature → BATT1 battery type → BATT2 voltage → BATT2 current → Max. BATT1
voltage → Min.BATT2 voltage → PV voltage
6.3 Temperature units
Operation:
Step 1: Press the button under the battery temperature interface.
Step 2: Press the button to select the temperature unit.
Step 3: Press the button to set successfully.
6.4 Clear the generated energy
Press the and button and hold for 5s to clear the generated energy.
6.5 Battery type
1)Operation:
Step 1: Press the button and hold for 5s under the battery type interface.
Step 2: Press the button when the battery type interface is flashing.
Step 3: Press the button to confirm the battery type.
2) Battery type
| BATT1 12V Sealed| | BATT1 24V Sealed
---|---|---|---
| BATT1 12V Gel| | BATT1 24V Gel
| BATT1 12V Flooded| | BATT1 24V Flooded
| LiFePO4 (4S)| | LiFePO4 (8S)
| Li-NiCoMn (3S)| | Li-NiCoMn (6S)
| User| |
NOTE: The battery voltage is set as default and not changeable when
selecting the default battery type. Please change to “User” battery type
before adjusting the battery voltage. Set the voltage of the “User” battery
type via PC software only.
1) Lead-acid Battery Control Voltage Parameters
The parameters below are for a 12V system at 25 ºC. Please double the
values in a 24V system.
Battery type /Voltage parameter| Sealed| Gel| Flooded|
User
---|---|---|---|---
Over Voltage Disconnect Voltage| 16.0V| 16.0V| 16.0V| 9-17V
Charging Limit Voltage| 15.0V| 15.0V| 15.0V| 9-17V
Over Voltage Reconnect Voltage| 15.0V| 15.0V| 15.0V| 9-17V
Equalize Charging Voltage| 14.6V| →| 14.8V| 9-17V
Boost Charging Voltage| 14.4V| 14.2V| 14.6V| 9-17V
Float Charging Voltage| 13.8V| 13.8V| 13.8V| 9-17V
Boost Reconnect Charging Voltage| 13.2V| 13.2V| 13.2V| 9-17V
Low Voltage Reconnect Voltage| 12.6V| 12.6V| 12.6V| 9-17V
Under Voltage Warning Reconnect Voltage| 12.2V| 12.2V| 12.2V| 9-17V
Under Volt. Warning Voltage| 12.0V| 12.0V| 12.0V| 9-17V
Low Volt. Disconnect Voltage| 11.1V| 11.1V| 11.1V| 9-17V
Discharging Limit Voltage| 10.6V| 10.6V| 10.6V| 9-17V
Equalize Duration (min.)| 120| →| 120| 0-180
Boost Duration (min.)| 120| 120| 120| 10-180
NOTE:
- When the battery type is sealed, gel, or flooded, the adjustable range of equalize duration is 0 to 180min, and boost duration is 10 to 180min.
- The following rules must be observed when modifying the value of the parameters in User battery type (factory default value is the same as sealed type):
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize
Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage >
Boost Reconnect Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage C. Low
Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥
Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
2) Lithium Battery Control Voltage Parameters
The parameters below are for a 12V system at 25 ºC; please double the values
in a 24V system.
Battery type/ Voltage parameter | LiFePO4 (4S) | Li-NiCoMn (3S) | User |
---|---|---|---|
Over Voltage Disconnect Voltage | 15.6V | 13.5V | 9-17V |
Charging Limit Voltage | 14.6V | 12.6V | 9-17V |
Over Voltage Reconnect Voltage | 14.5V | 12.5V | 9-17V |
Equalize Charging Voltage | 14.5V | 12.5V | 9-17V |
Boost Charging Voltage | 14.5V | 12.5V | 9-17V |
Float Charging Voltage | 13.8V | 12.2V | 9-17V |
Boost Reconnect Charging Voltage | 13.2V | 12.1V | 9-17V |
Low Voltage Reconnect Voltage | 12.4V | 10.5V | 9-17V |
Under Voltage Warning Reconnect Voltage | 12.5V | 11.0V | 9-17V |
Under Volt. Warning Voltage | 12.0V | 10.5V | 9-17V |
Low Volt. Disconnect Voltage | 11.0V | 9.3V | 9-17V |
Discharging Limit Voltage | 10.8V | 9.3V | 9-17V |
A. Over Voltage Disconnect Voltage > Over charging protection voltage
(Protection Circuit Modules (BMS))+0.2V;
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage = Charging
Limit Voltage ≥ Equalize Charging Voltage = Boost Charging Voltage ≥ Float
Charging Voltage > Boost Reconnect Charging Voltage;
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥
Discharging Limit Voltage;
D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage;
E. Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage;
F. Low Voltage Disconnect Voltage ≥ Over-discharging protection voltage
(BMS)+0.2V.
WARNING: Please refer to the voltage parameters of the BMS when adjusting
the lithium battery voltage parameters.
WARNING: The accuracy of BMS must be at least 0.2V. If the deviation is
higher than 0.2V, the manufacturer will assume no liability for any system
malfunction caused by this.
6.6 Fault indication
Fault | LCD | Instruction |
---|---|---|
BATT1 overvoltage | Battery level shows full, battery frame blink, fault icon |
blink.
BATT1 over- discharged| | Battery level shows empty, battery frame blink,
fault icon blink.
BATT1 over temperature| | Battery level shows current capacity, battery frame
blink, fault icon blink, the temperature icon blink, the temperature value
blink, the temperature unit blink.
BATT1 system voltage error®| | Battery level shows empty, battery frame blink.
① No alarm for system voltage fault when using Lithium batteries.
Technical Specifications
Compatible models | DM series (DM1024/DM2024/DM3024) |
---|---|
Self-consumption (Power on) | 13mA/5Vdc |
Self-consumption (Power off) | 4mA/5Vdc |
Communication protocol | RS485 |
Communication port | 3.81-4P |
RS485 cable | CC-RS485-RS485-3.81-4P-500 (5m) |
Environmental temperature | -20ºC~+70ºC |
Storage temperature range | -20ºC~+70ºC |
Enclosure | IP20 |
Screen unit dimensions | 98.4×98.4mm |
Frame dimensions | 114×114mm |
Weight | 0.11kg |
Manual is subject to change without prior notice. Version number: 2.7