Metra 1398 8 Inch Lock Driver Owner’s Manual

September 3, 2024
Metra

**Metra 1398 8 Inch Lock Driver Owner’s Manual

**

PRODUCT DESCRIPTION

“Metra Lock Driver 8” is used in different Metra Electronic Locking applications. It drives and monitors Metra Electronic Locks. Up to 8 locks can be connected to one Lock Driver 8.

“Metra Lock Driver 8” is not standalone product and must be connected via MEW serial connection to Controller. Up to 8 “Metra Lock Drivers 8” can be connected to single Controller. Therefore 64 Electronic Locks can be controlled by single Controller in Metra ELS System. Metra Lock Driver 8 also supports security features. In case of attempt of locker break-in “Metra Lock Driver 8” detects such event and initiates alarm message. It also detects cable disconnection from any locked Electronic Lock and activates different type of alarm.

Product main features are:

  • Driver for 8 Electronic Locks.
  • Up to 8 “Metra Lock Drivers 8” supported by single Controller.
  • No external power supply, powered via MEW connection.
  • Electronic Lock cable length max 4m.
  • Alarm detection and activation in case of any Electronic Lock brake-in.
  • Alarm activation in case if Electronic Lock cable is disconnected while locked.

EXTERNAL CONNECTIONS

| Description

---|---
1| Electronic Lock 1
2| Electronic Lock 2
3| Electronic Lock 3
4| Electronic Lock 4
5| Electronic Lock 5
6| Electronic Lock 6
7| Electronic Lock 7
8| Electronic Lock 8
9| MEW connector 3 pole
10| MEW connector 3 pole

11| ISP Loader (maintenance only)

*NOTE: Metra Easy Wiring (MEW) connectors 9 and  10 are internally parallel connected.

Metra Easy Wiring (MEW) connection

MEW Connection (3-pole cable) is used to connect MEW Modules to Controller. “Metra Lock Drivers 8” are connected to the MEW line with Cable 3 pole 0,25 mm2.

See also appropriate Controller’s Technical Manual for a specific wiring scheme(s). Further explanation is also  in chapter 9 of this manual “Connecting Metra Lock Driver 8 to Controller

Connect the MEW cable to one of the 3 pole terminals marked “MEW”. For details see “Metra Easy Wiring (MEW) – Installation Manual.pdf”.

NOTE: Each “Metra Lock Driver 8” MEW Module has two 3-pole MEW connectors. You can use one for an incoming line and one for an outgoing line as shown on the photo. Both are internally interconnected. This way you can always easily connect to Controller and additional MEW Module.

ISP Loader

This connector is used by authorised Maintenance personnel only. It serves for firmware downloading.

CONNECTING METRA ELECTRONIC LOCKS

Up to 8 “Metra Electronic Locks” can be connected to “Metra Lock Driver 8”:

  • Connect Electronic Locks using 6 pole flat cables.
  • Maximum length of each cable is 4 meters.
  • Cables from Electronic Locks with lower locker numbers must be connected to lower index connector. Locker number is increasing from left to right (blue arrow)!
  • Mind ascending order when numerating lockers.

EXAMPLE: Most left connector (index 1) is locker with index “n”, most right connector (index 8) is locker with index “n + 7”.

For connecting Electronic locks use Flat cable 6 pole. Mind the orientation. Red side of flat cable place on pin1 of connector 6 pole.

When connecting cable to Electronic Lock mind the orientation of connector. The “nose” must be placed on upper side, as shown on picture.

The other side of Flat Cable 6 pole connect to Lock Driver 8. Mind coupling the “nose” and gap on connector.

MEW ADDRESS SETTING

# description
1 MEW Address DIP switch

By changing the DIP Switch 1 pins position, different MEW Address can be set. To change between different pins positions, use a small flat headed screwdriver or similar object to push DIP switch pins to desired position.

ATTENTION

Each Metra MEW Module connected to the same Controller board must have different MEW Address setting.

Look up the code for desired MEW Address in the coding table. Set switches #1 through #4 to indicated positions, where:

  • 0 indicates the corresponding switch is in OFF position (switch down)
  • 1 indicates the corresponding switch is in ON position (switch up)

Coding table:

MEW Address coding rules for “Metra Lock Driver 8”:

  • Each “Metra Lock Driver 8” connected to single Controller needs to have different MEW Address.
  • Maximum 8 “Metra Lock Driver 8” modules can be connected to single Controller.
  • Their MEW Address range must be set from 1 – 8.
  • Always start with MEW Address 1 and connect to this Module from left to right Lockers with lowest Locker Numbers!

ATTENTION

MEW Address of the Device is obtained from DIP switch at power-up. DIP switches must be therefore properly set during physical installation, before Power ON!

POWER SUPPLY

The Device is powered via MEW 3-wire Connection from the Controller. There is no need for External Power Supply!

  • Red wire … (+12 VDC)
  • Blue wire … (GND)

Connect the MEW cable to one of the 3 pole terminals marked “MEW”. For details see “Metra Easy Wiring (MEW) – Installation Manual.pdf”.

SIGNALISATION LIGHTS

| description

---|---
1| MEW status
2| Electronic Lock motor operation

MEW status

Metra Easy Wire network (LIN) blue status LED 1 is:

  • Blinking slowly in RUNNING pattern when operation is normal and Communication with Controller is established.
  • Blinking rapidly when there is no MEW communication with Controller. Check the connecting 3 pole cable!

Electronic lock motor operation

Maximum 8 Electronic Locks are connected to “Metra Lock Driver 8”. When power is applied to any of the electronic lock connectors red LED 2 is ON. Normaly this light is off when no power is needed to Lock/Unlock any Electronic Lock.

CONNECTING “METRA LOCK DRIVERS 8” TO CONTROLLER

This chapter explains how to connect up to 8 “Metra Lock Drivers 8” to Controller as well as their MEW Address Setting. Up to 64 Metra Electronic Locks can be controlled by connecting 8 “Metra Lock Drivers 8” to Controller.

There are two basic topologies used when connecting MEW Modules to Controller:

  • Concentrated
  • Distributed

Concentrated Topology

“Metra Lock Drivers 8” are placed togather in the same compartment. Electronic Locks are then wired and connected also there at the same place. Total length of interconnecting MEW cable is limited to 10m. It uses:

3 x 0.25 mm interconnecting cable.

See Appendix 1 for detailed block scheme!

Distributed Topology

In case that “Metra Lock Drivers 8” need to be spaced up to 40m total length away use Distributed topology. It uses:

  • “Adapter 3-pole”.
  • 3 x 0.25 mm interconnecting cable between Adapter 3-pole and “Metra Lock Driver 8” max length 10m (blue, white, red)
  • 3x 0,82 mm interconnecting cable between “Adapters 3-pole” maximum total Length 40m. (yellow, red, black.

See Appendix 2 for detailed block scheme!

MECHANICAL DETAILS AND MOUNTING INSTRUCTIONS

See also appropriate application manual for a specific wiring scheme(s).

Carefully chose the place to mount the device. Keep in mind maximal length of cables to the Electronic Locks (4 m). Lock Driver 8 must be accessible only to maintenance personnel.

Connect the MEW cable to the 3 pole terminals marked “MEW” and 6 pole flat cables to appropriate 6 pole connectors. For details see “Metra Easy Wiring – Installation Manual.pdf”.

NOTE: carefully fold the cable so that the output goes straight through the slot in cover.

Put the cover over electronics, to protect it against accidental short circuit, humidity and dust.
Lock Driver 8 can be mounted on top of the lockers or into the locker. There can be mounted on the inner locker wall or simply laid on the bottom. All depends on available space and wiring configuration.

Because of different type of lockers, no mounting material is added. Generally double-sided adhesive tape or screws can be used.

If there is a possibility for the hanging cables to remove the cover or whole device, cables should be additionally fixed to protect against disassembling. For that purpose, different supporting utility can be used.

TECHNICAL DATA

Operating voltage| 12V DC regulated delivered by MEW Controller via MEW
Connection. No external Power Supply needed!
---|---
Current consumption| 0.04A average / 0.15A max.
Operating temperature range| 0 to +50 °C
Electronic Lock Interface| Up to 8 el. locks, 6 wire flat cable, max. length 4m
Light signalization| Blue LED and Red LED
Dimensions in mm (w/h/l)| 84/26/184
Connections| 2 x MEW, 8 x Electronic Locks, ISP

APPENDIXES

Appendix 1: Concentrated Topology

Maximum concentrated configuration

Appendix 2: Distributed Topology

Maximum distributed configuration

REGULATORY INFORMATION

  • Manufacturer:Metra inženiring d.o.o. IOC Trzin Špruha 19 SI-1236 Trzin, Slovenia
  • Trade Mark: Metra MEW System
  • Model/Type ref.: Metra Lock Driver 8
  • Part Number: 1398
  • Year of Construction: 2013 – 2018
  • phone:+386 1 56 10 740
  • fax:+386 1 56 10 744
  • web:  www.metra.si

© 23th January 2019 Metra inženiring d.o.o.

All Rights reserved. The contents of this document are subject to change without notice.

This product is in conformity with the essential requirements and other relevant requirements of the following EU Directives:

  • RoHS Recast (RoHS2) Directive 2011/65/EU of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronics equipment.
  • The Electromagnetic Compatibility (EMC) Directive 2014/30/EU ensures that electrical and electronic equipment does not generate, or is not affected by, electromagnetic disturbance.
  • The Radio Equipment Directive (RED) 2014/53/EU ensures that the radio equipment meets the respective essential requirements

Environmental Information for EU customers – WEEE Directive Statement:

This symbol indicates the product is in conformity with the protection requirements of European Council Directive 2012/19/EU. It requires that products marked with this symbol must not be disposed of with unsorted municipal waste.

This product must be disposed of separately from household waste via designated collection facilities appointed by local authorities. Please contact your local authorities or waste disposal service for more detailed information.

Model/Type ref.: Metra Lock Driver 8
Part Number : 1398

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.