KIDDE 20SAR-CA Photoelectric Smoke Alarm User Guide
- September 4, 2024
- Kidde
Table of Contents
- Smoke Alarm: What To Do When The Alarm Sounds
- Carbon Monoxide Alarm: What To Do When The Alarm Sounds
- Other Alarm Visual And Audible Indicators
- Troubleshooting Guide
- Introduction, Product Features And Specifications
- Limitations Of Smoke Alarms
- Recommended Locations For Smoke Alarms
- Locations To Avoid
- Wiring / Installation / Activation
- Operation And Testing
- Recognizing Nuisance Alarms
- Battery Backup
- Cleaning Your Alarm
- Good Safety Habits
- Service And Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User Guide
Photoelectric Smoke Alarm
with Hardwire Interconnect
Model 20SAR-CA
SMOKE ALARM
Helps Reduce Cooking
Nuisance Alarms
P/N: G-000024-00 EN Rev. A
-
120V HARDWIRE INTERCONNECT
-
AA BATTERY BACKUP
(AC POWER REQUIRED) -
SELF-TESTING (SEE SECTION 10)
Thank You for Purchasing this Kidde Alarm
Hardwired for 120V AC, this model includes two replaceable AA backup
batteries. It also contains HUSH™ to temporarily silence nuisance alarms, and
“self-testing” features (see section 10).
Teach children how to respond to the alarm and that they should never play
with the unit.
This alarm is a multi-criteria device designed to detect smoke from any source
of combustion in a residential environment. It is not designed for use in a
recreational vehicle (RV) or boat.
NOTE: Please thoroughly read this user guide and save the document for
future reference and to pass on to any subsequent owner. Images are
representative only. Actual product may vary slightly.
Underwriters Laboratories of Canada (CAN/ULC), The National Fire Protection
Association (NFPA), and the manufacturer recommend replacing this alarm after
ten years.
Product Support: 1-800-880-6788
Please write down the below information and have this at hand when you call.
Date Code (on back): _
Date of Purchase: ___
Where Purchased: ___
Date to Replace: ____
Smoke Alarm: What To Do When The Alarm Sounds
The smoke alarm pattern is three long beeps, a 1.5 second pause, and three
long beeps repeating.
The red LED blinks in time with the alarm pattern only on the alarm(s) that
detected the hazard (initiating alarm).
- Alert small children in the home as well as anyone else that might have difficulty recognizing the importance of the alarm sounding or that might have difficulty leaving the area without help.
- Plan two ways out! Leave immediately by your escape plan. Don’t waste time getting dressed or picking up valuables.
- While leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don’t open that door! Instead, use your alternate exit. If the inside of the door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in.
- If the escape route requires you to go through smoke, stay close to the floor where the air is cleaner. Crawl if necessary, and breathe shallowly through a cloth, wet if possible.
- Once outside, go to your selected meeting place and make sure everyone is there.
- Call the fire department or 911 from your cell phone outside, or from your neighbour’s home-not from yours!
- Don’t return to your home until the fire officials say that it is all right to do so.
NOTE: See Section RECOGNIZING NUISANCE ALARMS, for nuisance alarm situations.
Carbon Monoxide Alarm: What To Do When The Alarm Sounds
NOTE: THIS IS NOT A CARBON MONOXIDE (CO) ALARM, BUT WILL RECEIVE AND
TRANSMIT A CO ALARM SIGNAL FROM AN INTERCONNECTED CO OR COMBINATION SMOKE / CO
ALARM.
The carbon monoxide (CO) alarm pattern is four quick beeps repeating every 5
seconds. The red LED blinks in time with the alarm pattern .
WARNING: ACTUATION OF THIS DEVICE INDICATES THE PRESENCE OF CARBON
MONOXIDE (CO) WHICH CAN KILL YOU. IF ALARM SIGNAL SOUNDS:
-
IMMEDIATELY MOVE TO FRESH AIR – OUTDOORS OR BY AN OPEN DOOR/WINDOW. DO A HEAD COUNT TO CHECK THAT ALL PERSONS ARE ACCOUNTED FOR. DO NOT RE-ENTER THE PREMISES OR MOVE AWAY FROM THE OPEN DOOR/WINDOW UNTIL THE EMERGENCY SERVICES
RESPONDERS HAVE ARRIVED, THE PREMISES HAVE BEEN AIRED OUT, AND YOUR ALARM REMAINS IN ITS NORMAL CONDITION. -
CALL YOUR LOCAL EMERGENCY SERVICE (FIRE DEPARTMENT OR 911)
PHONE NUMBER
NEVER RESTART THE SOURCE OF A CO PROBLEM UNTIL IT HAS BEEN CORRECTED. NEVER
IGNORE THE ACTIVATION OF THE ALARM!
NOTE: See Section RECOGNIZING NUISANCE ALARMS, for nuisance alarm
situations.
Other Alarm Visual And Audible Indicators
Operational Mode| Visual Indications| Audible Indications|
Action/Note
---|---|---|---
Normal (standby)| AC power: Green LED on continuously.
DC power: Green LED blinks approx every 60 sec.| |
Test (button press when no alarm condition is present)
(Note: Test is very loud, stand a few feet away.)| Red LED blinks
in time with alarm pattern.| • Single beep.
•3 long beeps, pause, 3 long beeps.| Perform button press once a week to
verify proper alarm operation.
Smoke Alarm Memory (unit has experienced a smoke event.)| Red LED
blinks every 15 sec.| | NOTE: Alarm memory is only retained for 24 hrs. Push
button to clear Alarm Memory.
Smoke Alarm Hush TM **Mode| Red LED blinks every 2 sec. (only on the
initiating alarm)| After button push, smoke alarm pattern stops. (If there is
too much smoke to allow HushTM, smoke alarm pattern continues.)| This feature
is to be used only when a known alarm condition, such as smoke from cooking,
activates the alarm. Push button during HushTM to clear HushTM and perform a
test.
Initiating Alarm (multiple alarms in an interconnected system)**| Red
LED blinks in time with alarm pattern indicating that this is the unit
initiating the alarm in an interconnected, multiple alarm, system.
NOTE: It is possible for more than one unit to detect a haz- ard and become an
initiating alarm unit (Red LED blinking).| Unit in smoke alarm mode.|
Troubleshooting Guide
If you require further information please contact Product Support at
1-800-880-6788 or write us at:
Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L 1A0. Our internet address is
www.kiddecanada.com.
Trouble Condition| Visual Indications| Audible Indications|
Action
---|---|---|---
False Low Battery (AC power connected before backup battery
activated)| None| Chirp every 60 sec.| Pull the battery pull tab to
activate the backup batteries.
Low Battery| Amber LED blinks every 60 sec.| Chirp every 60 sec.| Push
button once to silence for 24 hrs. (Push button again to clear HushTM and
perform a test.) Note: 7 days after Low Battery begins, the notifications
cannot be silenced.
- Replace batteries as soon as possible.
Smoke Sensor Fault| Amber LED blinks every 60 sec.| 3 chirps every 60 sec.| * See Cleaning Your Alarm section. - Push button once to attempt to reset the unit.
- If error continues, remove alarm, dispose unit, and replace as soon as possible.
Fatal Fault| Amber LED blinks 3 times every 60 sec.| 3 chirps every 60 sec.| * Push button once to attempt to reset the unit. - If error continues, remove alarm, dispose unit, and replace as soon as possible.
End of Unit Life| Amber LED blinks 2 times every 60 sec.| 2 chirps every 60 sec.| * Push button once to silence for 24 hrs. (Push button again to clear HushTM and perform
a test.) Note: 7 days after End of Unit Life begins, the notifications cannot be silenced. - Remove alarm, dispose unit, and replace as soon as possible.
MCU Failure| None| Constant Tone| Remove alarm, dispose unit, and replace as soon as possible.
Stuck Button| Amber LED blinks 4 times every 60 sec.| 3 chirps every 60 sec.| Push button to dislodge it from being stuck. If button cannot be unstuck, remove alarm, dispose unit, and replace as soon as possible.
Introduction, Product Features And Specifications
Introduction
This alarm detects products of combustion using a photoelectric sensor.
Ten (10) years after the unit was installed, powered up, and tested, this unit
will automatically alert you that it is time to replace the unit. This is
called “End of Unit Life” mode. See Troubleshooting Guide. To help identify
the date to replace the unit, a label has been affixed to the side of the
alarm.
Product Features and Specifications:
- Powered by 120VAC (60 Hz, 42 mA max) wire-in connector with two AA battery backup
- Reduced nuisance alarms
- Self-testing (see section 10)
- Easy installation
- Hardwire interconnectable to other compatible alarms
- Smoke Alarm Hush™
- Smoke Sensor: Photoelectric
- Temperature Operating Range: 4.4°C (40°F) to 37.8°C (100°F)
- Humidity Operating Range: up to 95% RH non-condensing
- Audible Alarm: 85+ dB at 3m (10ft), 3.0 to 3.5 KHz pulsing alarm
- This Class B digital apparatus complies with Canadian ICES-003
ISED Compliance Notice
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Limitations Of Smoke Alarms
WARNING: PLEASE READ CAREFULLY AND THOROUGHLY
- Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants.
- There are situations where a smoke alarm may not be effective to protect against fire as stated in CAN / ULC-S552, CAN/ULC-S553, and the NFPA Standard 72. For instance: a) smoking in bed b) leaving children home alone c) cleaning with flammable liquids, such as gasoline
- Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires. A smoke alarm may not be effective in some situations, such as during incendiary fires where the fire grows so rapidly that an occupant’s egress is blocked even with properly located smoke alarms, or when victims are intimate with the fire (for example, when a person’s clothes catch fire while cooking), too old or young, or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible. For these people, additional strategies such as protection-in-place or assisted escape or rescue are necessary. *
- This model meets the latest residential smoke alarm standards, which includes enhanced resistance to nuisance alarms from cooking. Industry experts recommend that both ionization and photoelectric smoke alarms be installed to help ensure optimal detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.
- A battery powered alarm must have a battery of the specified type, in good condition and installed properly (this model includes two AA replaceable backup batteries).
- This device requires a continuous supply of electrical power from a healthy battery or AC connection, depending on the model. It will not work without power.
- Smoke alarms must be tested regularly to make sure the battery and the alarm circuits are in good operating condition.
- Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Therefore, smoke alarms may not sense fires starting in chimneys, within walls, on roofs, on the other side of a closed door or other obstructions.
- If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper.
- The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For optimal detection, a smoke alarm should be installed in each sleeping area on every level of a home.
- Reference National Fire Protection Association (NFPA) standard 72
Recommended Locations For Smoke Alarms
- Locate smoke alarms in all sleeping areas. Try to monitor the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area.
- Locate additional alarms in stairways, because stairways act like chimneys for smoke and heat.
- Locate at least one alarm on every floor level.
- Locate an alarm in every bedroom.
- Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).
- Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent an alarm not located in that room from waking the sleeper.
- Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.
CAN/ULC-S553 and NFPA 72 state: “Smoke alarms in rooms with ceiling slopes greater than 0.3 m in 2.4 m (1 ft in 8 ft) horizontally shall be located on the high side of the room.” (See Figures 7-C)
- For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION section.
- When mounting an alarm on the ceiling, locate it at a minimum of 10 cm (4”) from the side wall (Figure 7-A).
- When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 10 cm (4”) and a maximumof 30.5 cm (12”) below the ceiling (Figure 7-A).
- Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 9.1m (30 ft) long.
- Install Smoke Alarms on sloped, peaked or cathedral ceilings at least 0.9m (3ft) from the highest point (measured horizontally). See Figure 7-C.
This equipment should be installed in accordance with: (1) C22.1-12, Canadian
Electrical Code, Part I, Safety Standard for Electrical Installations; and (2)
CAN/ULC-S553, Standard for Installation of Smoke Alarms.
Mobile Home Installation
Modern mobile homes have been designed and built to be energy efficient.
Install smoke alarms as recommended above. In older mobile homes that are not
well insulated compared to present standards, extreme heat or cold can be
transferred from the outside to the inside through poorly insulated walls and
roof. This may create a thermal barrier which can prevent the smoke from
reaching an alarm mounted on the ceiling. In such units, install the smoke
alarm on an inside wall with the top edge of the alarm at a minimum of 10 cm
(4”) and a maximum of 30.5 cm (12”) below the ceiling. If you are not sure
about the insulation in your mobile home, or if you notice that the outer
walls and ceiling are either hot or cold compared to the room air temperature,
install the alarm on an inside wall. CAN/ULC-S553 and NFPA 72 require smoke
alarms be installed in each sleeping area.
WARNING: TEST YOUR ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE
OR UNOCCUPIED, AND AT LEAST ONCE A WEEK DURING USE.
Locations To Avoid
(See Figures 7-A, 7-B, & 7-C for recommended locations)
- In the garage. Products of combustion are present when you start your automobile.
- Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm silence feature and should not be installed within 1.8m (6 ft) of cooking appliances.
- Do not install within 1.8m (6 ft) of heating appliances.
- In an area where the temperature may fall below 4.4 ºC (40 ºF) or rise above 37.8 ºC (100ºF), such as garages and unfinished attics.
- In dusty areas. Dust particles may cause nuisance alarms or a failure to alarm.
- In very humid areas (above 95% RH, non-condensing) as moisture or steam can cause nuisance alarms.
- In insect-infested areas.
- Smoke alarms should not be installed within 0.9m (3 ft) of the door to a bathroom containing a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air flow areas.
- Near lights. Electronic “noise” generated by the lights may cause nuisance alarms.
- Do not install near vents, flues, or chimneys.
- Do not install near fans, doors, windows or areas directly exposed to the weather.
- Avoid installing where the unit will be exposed to direct sunlight.
Wiring / Installation / Activation
NOTE: A dust cover has been installed on the alarm. Keep the dust cover on until all construction has been completed for at least 24 hours (drywall, painting, varnishing, mounting plate install, etc). Retain the dust cover and re-install it to protect the alarm during future construction projects. Construction dust and chemicals can cause contamination and false alarms.
WARNING: DUST COVER MUST BE REMOVED FOR ALARM TO OPERATE.
NOTE: To avoid false low battery chirping pull out the battery pull tab
first to activate the backup batteries (see Figure 9-A). Battery activation is
confirmed with a beep. If the beep does not occur when the battery pull tab is
removed, remove the batteries and reinstall them. Confirm the battery
activation beep.
Wiring Requirements
- This alarm should be installed on a CSA-Listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with codes having jurisdiction in your area. The multiple station interconnect wiring to the alarms must be run in the same raceway or cable as the AC power wiring. In addition, the resistance of the interconnect wiring shall be a maximum of 10 ohms.
- The maximum wire run distance between the first and last unit in an interconnected system is 305 m (1000 ft).
- The appropriate power source is 120 Volt AC Single Phase supplied from a non-switchable circuit.
- Smoke alarms are not to be used with detector guards unless the combination (alarm and detector guard) has been evaluated and found suitable for that purpose.
- Kidde alarms are not designed, agency tested or certified for recessed mounting and should not be installed in this manner. Recessed mounting impedes smoke entry into the smoke chamber, which may prevent the alarm from sounding in a timely manner. This could endanger the lives of occupants in the residence. Kidde alarms are designed, tested and certified for wall (if applicable) and ceiling surface mount only.
WARNING: THE ALARM CANNOT BE OPERATED FROM POWER DERIVED FROM A SQUARE WAVE, MODIFIED SQUARE WAVE OR MODIFIED SINE WAVE, INVERTER. THESE TYPES OF INVERTERS ARE SOMETIMES USED TO SUPPLY POWER TO THE STRUCTURE IN OFF GRID INSTALLATIONS, SUCH AS SOLAR OR WIND DERIVED POWER SOURCES. THESE POWER SOURCES PRODUCE HIGH PEAK VOLTAGES THAT WILL DAMAGE THE ALARM.
Wiring Instructions for AC Quick Connector Harness
CAUTION: Turn off the main power to the circuit before wiring the alarm.
-
For alarms that are used as single station, DO NOT CONNECT THE RED WIRE TO ANYTHING. Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box.
-
When alarms are hardwire interconnected, all interconnected units must be powered from a single circuit.
-
A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18alarms total (smoke, CO, Smoke/ CO Combination, heat, etc.). With 18 alarms interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules.
-
Figure 9-B illustrates interconnection wiring. Improper connection will result in damage to the alarm, failure to operate, or a shock hazard.
-
Make certain alarms are wired to a continuous (non-switched) power line.
NOTE: Use agency approved household wire (as required by local codes)
available at all electrical supply stores and most hardware stores.
NOTE: AC power should be turned off at this stage.
- For best results to minimize nuisance alarms, interconnected alarms should be on a dedicated line. If not on a dedicated line, it is suggested that the smoke alarms share a lighting load circuit that does not have a dimmer associated with it. If receptacles must be placed on the same line it is suggested that they be placed ahead of the smoke alarms (see Figure 9-C). This will prevent large voltage drops from occurring between the first and last alarm in the circuit.
- After selecting the proper location for your alarm, and wiring the AC QUICK CONNECTOR harness as described previously, attach the mounting bracket to the electrical box. To ensure aesthetic alignment of the alarm with the hallway, or wall, the “A” line on the mounting bracket should be parallel with the hallway when ceiling mount- ed, or horizontal when wall mounted. (See Figure 9-D)
- Pull the AC QUICK CONNECTOR through the center hole in the mounting bracket and secure the bracket, making sure that the mounting screws are positioned in the small ends of the keyholes before tightening the screws.
- Plug the AC QUICK CONNECTOR into the back of the unit, making sure that the connector snaps into place. Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket.
NOTE: Do not grab the shield to install or remove the alarm. Grab the alarm by the outside of the enclosure. (Figure 9-E).
NOTE: If either battery is missing, the alarm cannot mount on the mounting bracket.
-
Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction (Figure 9-F)
NOTE: The alarm will mount to the bracket in 4 positions (every 90 degrees). -
Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
NOTE: Attaching AC power first, without removing the battery pull tab, will result in a false low batterytrouble condition chirp (see Troubleshooting Guide). You need to activate the batteries to eliminate the false low battery trouble condition chirps. Remove the battery pull tab to avoid false low battery notification.
AC Wired Interconnect Model Capability
This model has AC hardwire interconnect capability. When one hardwired
interconnect unit sounds an alarm, all other compatible hardwire or
interconnected units will also alarm.
NOTE: AC wiring must be completed properly and the AC quick connector
must be attached to the unit for the hardwire interconnect function to work.
The following models can be interconnected using the standard AC wiring
interconnect: i12020CA, i12020ACA, i12040CA, i12040ACA, i12060CA, i12060ACA,
i12010SCA, i12010SCOCA, i4618CA, i4618ACA i4618AC-CA, KN-COSM-IBACA, KN-
SMFM-I-CA, KN-COB-ICB-CA, KN-COSMIBCA, KN-COB-IC-CA, KN-COSM-ICA, KN-COP-IC-
CA, KN-COPE-ICA, P12040CA, Pi2000CA, Pi2010CA, SM120X, SLED177iCA,
P4010ACLEDSCA, P4010ACLEDSCOCA, P4010ACLEDSCA-2, P4010ACLEDSCOCA-2,
P4010ACSCO-WCA, P4010ACSCOCA, P4010LACS-WCA, P4010ACSCA, P4010ACS-WCA,
P4010ACSCO-WF-CA, P4010ACSCOAQ-WF-CA, 900-CUAR-VCA, 20SAR-CA, 20SA10-CA,
20SA10-VCA, 30CUAR-VCA, 30CUA10-VCA.
The alarm is now activated! After installation / activation, test your alarm
as described in Operation and Testing section.
WARNING: FAILURE TO PROPERLY CONNECT AC POWER AND INSTALL BATTERIES IN
THE CORRECT ORIENTATION WILL PREVENT PROPER OPERATION OF THIS ALARM AND WILL
PREVENT ITS RESPONSE TO FIRE HAZARDS.
Operation And Testing
This model meets the latest residential smoke alarm standards, which includes
enhanced resistance to nuisance alarms from cooking.
Operation
The alarm is operating once it is activated and testing is complete (see
“TESTING” below). When products of combustion (smoke) are sensed, the unit
sounds a loud alarm. See Section 1 for alarm signal descriptions.
Testing
WARNING: Do not attempt to test this unit with retail “canned smoke”
products. Those products are intended for use by trained professionals and
produce inconsistent results when misused.
Over-application of canned smoke can permanently damage the alarm.
SELF-TESTING
This model is equipped with internal, self-testing components that are always
checking to ensure the device is operating as expected. (Weekly manual testing
is still required. See below.)
MANUAL TESTING
NOTE: When pushing the Test button, use only your finger or thumb. Using
any other instrument(s) (such as a broom handle) is strictly prohibited, as it
may damage the alarm.
Test your alarm weekly by pressing and releasing the button quickly. A quick
beep will confirm the button has been pushed followed by the test sequence.
See Other Alarm Visual and Audible Indicators table. The alarm (and any
interconnected units) will sound if the electronic circuitry, horn, and
batteries are working. If the alarm does not sound, or gives erratic or low
volume sound, the unit must be replaced.
**WARNING: DUE TO THE LOUDNESS OF THE ALARM, ALWAYS STAND ABOUT 2.5
FEET AWAY FROM THE UNIT OR USE EAR PROTECTION WHEN TESTING.
WARNING: DO NOT USE AN OPEN FLAME TO TEST YOUR ALARM, YOU COULD DAMAGE
THE ALARM OR IGNITE COMBUSTIBLE MATERIALS AND START A STRUCTURE FIRE.
Chirping
When End of Unit Life or Low Battery chirping begins, you can temporarily
silence these chirps by pressing the button. Other fault/error chirps cannot
be silenced. Take appropriate action as described in the Troubleshooting
Guide.
****WARNING:** REPLACE UNIT AS SOON AS POSSIBLE WHEN IN END OF UNIT LIFE.
SEVEN (7) DAYS AFTER END OF UNIT LIFE BEGINS, THE NOTIFICATIONS CANNOT BE
SILENCED, AND SMOKE DETECTION CANNOT BE GUARANTEED. REPLACE IMMEDIATELY!
Recognizing Nuisance Alarms
Smoke Nuisance This model meets the latest residential smoke alarm standards,
which includes enhanced resistance to nuisance alarms from cooking.
HUSH™ : If you know why the alarm is sounding, and you can verify that it is
not a life threatening situation, you can push the button on the initiating
unit to silence the alarm for 8-10 minutes. If the smoke is not too dense,
that unit, and all interconnected units will silence. After the Hush™M period,
the smoke alarm will automatically reset and sound the alarm if particles of
combustion are still present. You can use Hush TM repeatedly until the air has
been cleared of the condition causing the alarm. NOTE: Dense smoke will
override Hush™ and sound a continuous alarm. If no fire is present, check to
see if one of the reasons listed in “Locations to avoid” may have caused the
alarm. If a fire is discovered, get out and call the fire department or 911.
Cigarette smoke will not normally cause the unit to alarm, unless the smoke is
blown directly into the alarm. Combustion particles from cooking may set off
the alarm if it is located too close to a cooking appliance. Large quantities
of combustible particles are generated from spills or when broiling. Using the
fan on a range hood which vents to the outside (non-recirculating type) will
also help prevent nuisance alarms from occurring by removing these combustible
products from the kitchen.
Carbon Monoxide (CO) Nuisance
WARNING: This unit does not detect CO, but it will transmit a CO alarm
signal from an interconnected CO or Smoke/CO combination alarm. It is
impossible to determine the source of a CO alarm using sight or smell. Always
consider a CO alarm event as dangerous.
- Pushing the button on the initiating CO or Smoke/CO combination alarm will silence that alarm and all compatible interconnected units.
- Pushing the button on any hard-wire smoke alarm will do nothing to silence an interconnected CO alarm.
Battery Backup
This alarm is powered with AC power, but also contains two replaceable AA
backup batteries. Under normal conditions, fresh batteries will last at least
one year.
In order to access the battery compartment, the wiring harness needs to be
removed. To release the wiring harness, press down on the tab as shown in
Figure 12-A.
NOTE: Constant exposure to high or low humidity or temperatures may
reduce battery life.
WARNING: THE ALARM IS SEALED AND THE COVER IS NOT REMOVABLE!
Low Battery
This alarm is equipped with a low battery monitor circuit. If the battery
capacity is nearing the point where it can no longer provide adequate power
for all alarm functions, the low battery condition will occur. See
Troubleshooting Guide. The batteries must be replaced within 7 days of the
first occurrence of the “Low Battery Warning” to provide continuous alarm
detection.
Replace batteries with one of the following approved brands:
Energizer E91, Gold Peak 15A or Golden Power GLR6A.
These batteries can be purchased at your local retailer.
WARNING: Use only the batteries specified. Use of different batteries may
have a detrimental effect on the alarm. Do not mix old and new batteries. Do
not mix alkaline, standard, or rechargeable batteries.
NOTE: Do not use lithium batteries in this unit. A good safety measure is
to replace the batteries at least once a year, or at the same time you change
your clocks for daylight saving time. Loss of AC power and a missing or
improperly installed battery will render the unit inoperable.
WARNING: FAILURE TO PROPERLY CONNECT AC POWER AND INSTALL BATTERIES IN THE CORRECT ORIENTATION WILL PREVENT PROPER OPERATION OF THIS ALARM AND WILL PREVENT ITS RESPONSE TO FIRE HAZARDS.
Cleaning Your Alarm
Your Alarm Should be Cleaned at Least Once a Year
You can clean the interior of your alarm (sensing chamber) by using compressed
air or a vacuum cleaner hose and blowing or vacuuming through the openings
around the perimeter of the alarm.
The outside of the alarm can be wiped with a clean, dry cloth. Do not use
water, detergents or cleaners as they may damage the alarm.
NOTE: Do not insert fingers or cleaning items under the shield during
cleaning.
If the alarm is in Fault mode, the alarm may be in need of cleaning. After
cleaning, press the button.
If the fault does not clear, the alarm needs to be replaced.
- Never use detergent or other solvents to clean the unit.
- Avoid spraying air freshener, hair spray, or other aerosols near the alarm.
- Do not use a hair dryer to clean the alarm, as it may damage the alarm and impact performance.
- Do not paint the unit. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
- Never attempt to disassemble the unit to clean inside. This action will void your warranty.
WARNING: REINSTALL THE ALARM AS SOON AS POSSIBLE TO ENSURE CONTINUOUS DETECTION.
Good Safety Habits
Develop and Practice a Plan of Escape
Prepare and practice a home escape plan twice a year, including drills at
night. Know two ways out of every room (door & window) and identify a meeting
place outside the home where everyone will gather once they have exited the
residence. When two people have reached the meeting place, one should leave to
call 911 while the second person stays to account for additional family
members. Establish a rule that once you’re out, you never re-enter under any
circumstance!
- Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room. Stories above ground level may need a rope or chain ladder.
- Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire and where to meet after they leave the house.
- Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency. You may not be able to reach your children. It is important they know what to do.
- Familiarize everyone with the sounds of the smoke alarm and train them to leave your home when they hear it.
- Current studies have shown smoke alarms may not awaken all sleeping individuals, and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound, or to those who may be incapable of safely evacuating the area unassisted.
- Install and maintain fire extinguishers on every level of the home and in the kitchen, basement and garage. Know how to use a fire extinguisher prior to an emergency.
Fire Prevention
Never smoke in bed or leave cooking food unattended. Teach children never to
play with matches or lighters! Train everyone in the home to recognize the
smoke alarm pattern and to leave the home using their escape plan when it’s
heard. Know how to do “Stop, Drop and Roll” if clothes catch on fire, and how
to crawl low under smoke. Install and maintain fire extinguishers on every
level of the home and in the kitchen, basement and garage.
Fire Safety in the Home
CAN/ULC-S553 and NFPA 72 are
intended to provide reasonable safety for persons in family living units.
Reasonable fire safety can be produced through the following three-point
program: (1) Minimizing fire hazards (2) Providing fire-warning equipment (3)
Having and practicing an escape plan. intended to provide reasonable safety
for persons in family living units. Reasonable fire safety can be produced
through the following three-point program: (1) Minimizing fire hazards (2)
Providing fire-warning equipment (3) Having and practicing an escape plan.
moke Detection – Are More Alarms Desirable?
The required number of smoke alarms might not provide reliable early
warning protection for those areas separated by a door from the areas
protected by the required smoke alarms. For this reason, it is recommended
that the resident consider the use of additional smoke alarms for those areas
for increased protection. The additional areas include the basement, bedrooms,
dining room, furnace room, utility room, and hallways not protected by the
required smoke alarms. The installation of smoke alarms in attics (finished or
unfinished), garages, or within 1.8 m (6 ft) of a heating or cooking appliance
is not normally recommended, as these locations occasionally experience
conditions that can result in improper operation. * Per CAN/ULC-S553 and NFPA
72: Where required by other governing laws, codes, or standards for a specific
type of occupancy, approved single and multiple-station smoke alarms shall be
installed as follows:
- In all sleeping rooms and guest rooms
- Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a sleeping room, with the distance measured along a path of travel
- On every level of a dwelling unit, including basements
- On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics
- In the living area(s) of a guest suite
- In the living area(s) of a residential board and care occupancy (small facility)
Service And Warranty
Ten-Year Limited Warranty
Kidde warrants that the enclosed alarm (but not the batteries) will be free
from defects in material and workmanship or design under normal use and
service for a period of ten years from the date of purchase. The obligation of
Kidde under this warranty is limited to repairing or replacing the alarm or
any part which we find to be defective in material, workmanship or design
(part replacement only, no installation), free of charge, upon receiving the
alarm with proof of date of purchase, postage and return postage prepaid, to
Warranty Service Department, Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L
1A0. Before shipping the product, please remove the batteries from the battery
compartment.
This warranty shall not apply to the alarm if it has been damaged, modified,
abused or altered after the date of purchase or if it fails to operate due to
improper maintenance or inadequate power. Any implied warranties arising out
of this sale, including but not limited to the implied warranties of
description, merchantability and fitness for a particular purpose, are limited
in duration to the above warranty period. In no event shall the Manufacturer
be liable for loss of use of this product or for any indirect,
special, incidental or consequential damages, or costs, or expenses incurred
by the consumer or any other user of this product, whether due to a breach of
contract, negligence, strict liability in tort or otherwise.
The Manufacturer shall have no liability for any personal injury, property
damage or any special, incidental, contingent or consequential damage of any
kind resulting from gas leakage, smoke, fire or explosion. Since some
provinces do not allow limitations of the duration of an implied warranty or
do not allow the exclusion or limitation of incidental or consequential
damages, the above limitations or exclusions may not apply to you. While this
warranty gives you specific legal rights, you may also have other rights which
vary from province to province.
The above warranty may not be altered except in writing signed by both parties
hereto.
Your Kidde Alarm is not a substitute for property, fire, disability, life or
other insurance of any kind.
Appropriate insurance coverage is your responsibility. Notify your local fire
department and insurance company of your alarm installation. Opening the unit
will void the warranty.
If there are any differences between this printed warranty and the online
limited warranty, then the terms of the online warranty supersede those in
this user guide or other printed materials. Visit
www.kiddecanada.com for the latest warranty
statement.
QUESTIONS OR FOR MORE INFORMATION
Call Kidde Product Support line at
1-800-880-6788
or contact us at www.kiddecanada.com
Kidde Canada Inc.
P.O. Box 40, Apsley, ON K0L 1A0
©2024 Kidde. All Rights Reserved.