ABSINA EV Charging Cable Mode 2 User Manual
- June 3, 2024
- ABSINA
Table of Contents
OPERATING MANUAL
EV CHARGING CABLE
MODE 2 | max. 11kW | 3-phase
8A – 10A – 13A – 16A
EV Charging Cable Mode 2
WELCOME
Thank you for purchasing your new ABSINA EV charging cable mode 2. With the
help of the operating instructions, you will be able to use the functions of
your charging cable optimally. We hope you enjoy using your new charging
cable.
Your ABSINA team.
EXPLANATION OF SYMBOLS
| The product complies with the requirements of the EU Directive.
---|---
| Do not dispose of the product in household waste!
Dispose of the product at an authorised waste disposal company or at a
municipal waste disposal facility. Observe the currently valid regulations. In
case of doubt, contact the disposal facility.
| Attention! A dangerous situation may occur if the measures are not
observed.
Risk of death, serious injury and burns!
| Do not use charging cables that are damaged at the housing, plug or cable!
| Do not use extension cables of any kind!
| Do not use multiple sockets!
| Do not use travel adapters!
| Vehicle coupling type 2
| Follow the operating instructions!
| Do not expose to direct sunlight!
INTENDED USE
Use the cable exclusively for charging electric and hybrid vehicles with
alternating current (AC) at CEE sockets with 16A load capacity. The cable may
only be used in conjunction with standardised and designated vehicle inlets
according to IEC 62196-2 (type 2 plug).
Compliance with all the information in these operating instructions is also
part of the intended use. Any other use or use beyond this is considered
misuse and can lead to dangerous situations. The user is liable for any damage
caused by improper use.
SAFETY INSTRUCTIONS
-
Only connect to a fault-free and suitable infrastructure (16A CEE socket). If in doubt, have a specialist check the suitability. Make sure that the fuse is not overloaded and that no other loads are connected to this fuse.
-
Improper handling of the charging cable can cause explosions, electric shocks and short circuits.
Observe the generally applicable safety precautions and the instructions. -
Before each use, check the charging cable and the contacts for damage and dirt.
-
Never charge with a damaged charging cable, vehicle inlet, control box or CEE socket.
-
Never charge with contacts that have become dirty or damp.
-
Never pull off the plug by force. Dangerous electric arcs can cause death or serious injury.
-
Only connect the charging cable to vehicle inlets and CEE sockets that are protected from water, direct sunlight, moisture and other liquids.
-
Some electric vehicles allow the vehicle to be started with the charging cable plugged in. Always make sure to disconnect the charging cable before driving off.
-
Do not use the charging cable with an extension cable or an adapter. Modifications or alterations are dangerous to life and will immediately void the warranty.
-
If the plug connection smokes or melts, never touch the charging cable. If possible, stop the charging process. Disconnect the relevant mains socket from the power supply (fuse, FI, switch).
-
Make sure that the charging cable is not accessible to children. Only persons with a valid driving licence for motor vehicles may operate the charging cable.
-
Only use the cable in protected outdoor areas.
OPERATION
- Read the instructions for the charging cable and the vehicle completely and carefully.
- Switch off the vehicle engine and put the gear lever in park.
- Connect the mains plug of the charging cable to a suitable socket (400V 16A).
- The green LED lights up to indicate that the vehicle is ready for charging.
- Remove the protective cap from the charging plug and connect the plug to the vehicle’s charging socket.
- The charging process starts automatically as soon as the blue LED starts flashing.
- Charging is complete when the green LED and the blue LED light up continuously.
- When the charging process is finished, pull the charging plug out of the charging socket of the vehicle and then pull the mains plug out of the mains socket (vehicle must be unlocked).
- Put the protective cap on the charging plug and roll up the cable without kinks.
Start charging
End charging
OPERATING ELEMENTS
LCD CHARGING STATUS INDICATOR
ERROR
The charging cable has several monitoring functions that are indicated by the
LEDs.
LED GREEN
| LED BLUE| LED RED| DESCRIPTION|
DECLARATION
---|---|---|---|---
| | | Standby| Sleep mode.
| | | Normal connection| Charging cable is connected to the vehicle.
| | | Charging| Battery is charging.
| | | Charging completed| Battery is fully charged.
| | | Failed self-test| The control box cannot establish communication with
the vehicle. Check that the connectors are correctly seated and check for dirt
in the de-energised state. If the fault cannot be rectified, send the charging
cable to the manufacturer for inspection.
| | 2x| Low voltage| The supply voltage is outside the tolerance range. Check
the mains voltage.
| | 3x| Over voltage| The supply voltage is outside the tolerance range. Check
the mains voltage.
| | 4x| Leakage current| The control box detects a fault current. Stop
charging, disconnect the charging cable from the vehicle and check the wiring
/ vehicle. Visit a specialist workshop.
| | 5x| Over current| The charging current is above the maximum value. Stop
charging and check the compatibility of the charging cable.
| | 6x| Charger overheated| The control box is overheated. This can be caused,
for example, by direct sunlight during the charging process. The charging
process is interrupted. After cooling down, the charging process starts
automatically.
| | 7x| PE error| The control box detects a fault in the PE line. Check mains
socket / mains connection.
= ON = OFF = FLASH|
TECHNICAL DATA
Input: | 400V |
---|---|
Charging plug: | IEC62196-2 Type 2 |
RCD: | 30mA AC + 6mA DC |
Rated power: | max. 11kW |
Output: | 8A – 10A – 13A – 16A |
Number of phases: | 3-phase |
Contact resistance: | ≤0.3mΩ (L/N) |
Isolation resistance: | 500MΩ (1.000V AC) |
High voltage strength: | 2.600V AC |
Contact temperature rise: | ≤50K |
Charging mode: | IEC 61851-1 |
Operating humidity: | 5% -95% non condensing |
Protection class: | IP55 (Vehicle plug in mated condition) |
IP54 (Control box)
Flammability class:| UL94 V-0
Protective functions:| Overvoltage, undervoltage, overcharging and overheating
protection (charge at +85°C interrupt, continue at 55°C), residual current, PE
control
Pull-off force:| 45N…80N
Plugging cycles:| ≥10.000x (Load-free)
Dimensions control box:| 240x107x61mm
Operating temperature:| -20°C…+50°C
Cable:| 5+1m length, 3*2.5mm2+0.75mm2
Weight:| 2.800g
LOADING TIME
The duration of the charging process depends on the capacity, the state of
charge of the vehicle’s highvoltage battery and the permissible charging power
of the charging cable and the CEE socket. The charging current (max. 16A) is
regulated by the vehicle (charging power may vary). At very low and very high
temperatures, the charging performance may be impaired.
CLEANING AND STORAGE
Only clean the cable when it is not connected to the vehicle and not to the
socket. Only clean the charging cable and the dirty contacts with a dry cloth.
Never use harsh cleaning agents, water or steam cleaners. Never immerse the
product in liquids. Store the charging cable with the protective caps on in a
dry and clean place.
ENVIRONMENTAL PROTECTION
Information according to the Electrical and Electronic Equipment Act
(ElektroG): Since 24 March 2006, old electrical appliances may not be disposed
of with household waste. These electrical and electronic appliances are marked
with a crossedout dustbin. Owners of old appliances from private households
can dispose of them at the collection points of the public waste management
authorities or at the take-back points set up by manufacturers or distributors
in accordance with the ElektroG.
GUARANTEE
The product is guaranteed for 2 years. No guarantee can be given for damage
resulting from nonobservance of the operating instructions.
EU Declaration of Conformity
DECLARATION OF CONFORMITY
We| Kurpfalzstr. 28
97944 Boxberg – Germany
---|---
Herewith we declare, that our product
Item:| EV Charge Cable Mode2 CEE-Type2 3 phase 11KW
Model:| Absina
Part number:| 52-230-1005
to which this declaration relates, is in conformity to the following
standard(s):| IEC 62196-2 : 2017
IEC 61851-1 : 2010
following the provisions of the Directive(s)
(EMV) 2014 / 30 / EU
(LVD) 2014 / 35 / EU
(RoHS) 2011 / 65 / EU
Boxberg, 04. April 2022
Heiko Schweizer – Geschäftsführer
ANY QUESTIONS?
Check our FAQs …
https://www.absina.com/pages/faq
… or contact our technical support team
TECHNICAL SUPPORT
HGPOWER GmbH
Kurpfalzstr. 28
97944 Boxberg
Germany
Hotline: +49 7930 9936 220
E-Mail:info@hgpower.de
WEEE-Reg.-Nr. DE 77661344
ABSINA GmbH
Carl-Benz-Strasse 9
74722 Buchen
GERMANY
Hotline: +49 6281 561 550 0