Installation

Follow these steps to install the dial thermostat:

  1. Turn off the power supply to the area where the thermostat will be installed.
  2. Mount the thermostat on a clean, flat wall surface away from direct sunlight and heat sources.
  3. Connect the wires according to the wiring diagram provided in the user manual.
  4. Secure the thermostat in place using the provided screws.
  5. Turn on the power supply and test the thermostat functionality.

Setting Temperature

To set the desired temperature:

  1. Rotate the dial to the desired temperature setting.
  2. Allow some time for the thermostat to adjust to the new setting.
  3. Monitor the temperature in the room and make adjustments as needed.

Maintenance

Regular maintenance is essential for optimal performance:

  • Periodically clean the thermostat surface with a soft, dry cloth to remove dust and debris.
  • Check for any loose connections or signs of wear and tear.
  • Ensure the thermostat is functioning correctly by testing it periodically.

Frequently Asked Questions

  • Q: How do I calibrate the thermostat?
    • A: Calibration instructions can be found in the user manual. Typically, it involves adjusting a calibration screw or setting within the thermostat.
  • Q: Can the thermostat be used for cooling systems?
    • A: The suitability of the thermostat for cooling systems depends on the specific model. Refer to the user manual or contact customer support for clarification.

Product Information

Perfect for water heating systems, these dial thermostats offer temperature adjustability between 0°C – 35°C. LED inidication when heating is activated

Dimension

International universal electronic heating thermostats can be installed directly on the wall. The temperature range is 10~ 35°C. It means it’s heating when the indicator lights up. It can be applied to automatic temperature control of heating system. It meets the high requirements for comfort, safety and energy-saving.

Parameter

  • Voltage:230V
  • Consumption:<2W
  • Temperature Range: 12~35°C
  • Temperature switch deviation: Default 1°C
  • Ambient temperature:0~50°C
  • Protection class:IP20
  • Load capacity:3A
  • Connecting Cable: RVV0.5
  • Housing material: PC+ABS

Sensor choosing and floor limit sensor setting:

This thermostat can choose different works way by set switch that is on the back of the product, which includes both: built-in and limitation floor sensors.The thermostat operates either with one of these sensors or with both of them. This kind of product can modify the different limited temperature values,setting the method as follows:

Description

This thermostat is applied to water heating system. Room temperature is adjusted by controlling the valve switch. Operation is easy. Set the temperature through the knob. The corresponding temperature to the comfortable positionis about 20°C. The corresponding temperature is higher as the knob position is turned higher. An annular red indicator will light up when heating. Please turn the knob to the low position when leaving for long- term to save energy.

Operating Instructions

  1. Switch off:OFF
  2. Comfortable position: about 20°C
    • Temperature setting range: 10~35°C
  3. Annular red indicator light:
    The light will be on after switch on, then off It means it is heating when red light is always on.

Selection of installation location

A thermostat should be installed on the wall where the air flows freely. Besides, the place where the thermostat is installed should be free of another heat source (such as sunlight), airflow from door and window, temperature of external wall and etc.

Fault phenomena and exclusion

Installation Diagram

  1. Remove the screw at the bottom of thermostat by a screwdriver.
  2. Open the front panel as shown in the following picture.
  3. Connect the wires correctly according to the wiring diagram and fix power base to the cassette by screws.
  4. Close the front panel and tighten the screw as shown in the following pictures to finish installation.

Our TIODIA0004S model, allows users to incorporate an external sensor for use in areas such as bathrooms. All other features are the same as the TIODIA0004 model.

Note:

This thermostat can be used in full load operation at a place whose altitude is no higher than 2,500m. For a place whose altitude is between 2,500 and 4,200m, the nominal power of external load should be no bigger than 80% of the nominal power of this product.

Installation Notes

  • Power must be off during installation.
  • Please connect the wires correctly according to a diagram.
  • It’s better that the installation height is 1.4m or on the same level of other wall switches.
  • Do not install thermostats at non-ventilated locations, for example, corner, behind the door.
  • Do not install thermostat at a place with strong airflow or near cold and heat source.
  • Sundries like water, cement slurry, and metal particles are forbidden going inside the thermostat. It will destroy the thermostat.