FRIGIDAIRE 16120300A31903 Room Air Conditioner Instruction Manual
- September 6, 2024
- Frigidaire
Table of Contents
16120300A31903 Room Air Conditioner
“`html
Specifications
- Brand: Frigidaire
- Model: Room Air Conditioner
- Power Supply: 115V 15A / 230V 15A / 230V 20A / 230V 30A
- Features: Current detection device, Grounding Prong
Product Usage Instructions
Introduction
Welcome to Frigidaire Room Air Conditioner! This manual is your
guide to using and caring for your appliance. Please read it
thoroughly before operating the air conditioner. If you encounter
any issues, refer to the troubleshooting section.
Safety Instructions
Ensure safety by following these important instructions:
-
Avoid storing flammable substances near the appliance.
-
Do not use extension cords or remove prongs from the power
cord. -
Keep the unit upright for one hour before operating.
Operating Instructions
To operate the air conditioner:
-
Ensure the unit is upright for an hour before plugging it
in. -
Plug in the unit and press the TEST button on the power supply
cord. -
Reset the cord by pressing the RESET button.
-
The unit is now ready to supply electricity (indicated by a
light on the plug head).
Care And Cleaning
Maintain your air conditioner by cleaning it regularly:
-
Turn off and unplug the unit before cleaning.
-
Use a soft cloth dampened with water to clean the
exterior. -
Remove and wash the filter every few weeks to maintain
efficiency.
Energy Saving Ideas
To save energy while using the air conditioner:
- Set the temperature to a moderate level.
- Avoid blocking the airflow with curtains or furniture.
- Use a timer to regulate operation based on your schedule.
FAQs
Q: Where can I find additional support and accessories
for my Frigidaire Room Air Conditioner?
A: You can visit www.frigidaire.com for FAQs,
tips, videos, cleaning products, and accessories. For further
assistance, you can chat with an agent or call customer
support.
“`
Room Air Conditioner
use & care
Introduction……………………………………………… 2 Important Safety Instructions……………….. 3 Packaging………………………………………………….12 Normal Sounds…………………………………………12 Air Conditioner Features………………………..13
Operating Instructions………………………….. 13 Care And Cleaning…………………………………20 Energy Saving Ideas…………………………….. 20 Before You Call……………………………………… 21 Major Appliance Limited Warranty……. 23
Frigidaire.com USA 1-800-944-9044
16120300A31903 (July 2019) Frigidaire.ca Canada 1-800-265-8352
2
INTRODUCTION
family Welcome to our
Thank you for bringing Frigidaire into your home! We see your purchase as the
beginning of a long relationship together.
This manual is your resource for the use and care of your product. Please read
it before using your appliance. Keep it handy for quick reference. If
something doesn’t seem right, the troubleshooting section will help you with
common issues.
FAQs, helpful tips and videos, cleaning products, and kitchen and home
accessories are available at www.frigidaire.com.
We are here for you! Visit our website, chat with an agent, or call us if you
need help. We may be able to help you avoid a service visit. If you do need
service, we can get that started for you.
Let’s make it official! Be sure to register your product.
Keep your product info here so it’s easy to find.
Model Number
Serial Number
Purchase Date
IMPORTANT SAFETY INSTRUCTIONS
3
WARNING
For Your Safety Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance. Read product labels
for flammability and other warnings.
WARNING
Prevent Accidents To reduce the risk of fire, electrical shock, or injury to
persons when using your air conditioner, follow basic precautions, including
the following: · Be sure the electrical service is adequate for the model you
have chosen. This information can be found on the serial plate, which is
located on the side of the cabinet and behind the grille. · If the air
conditioner is to be installed in a window, you will probably want to clean
both sides of the glass first. If the window is a triple-track type with a
screen panel included, remove the screen completely before installation. · Be
sure the air conditioner has been securely and correctly installed according
to the separate installation instructions provided with this manual. Save this
manual and the installation instructions for possible future use in removing
or reinstalling this unit. · When handling the air conditioner, be careful to
avoid cuts from sharp metal fins on front and rear coils.
WARNING
The power cord is equipped with a three-prong grounding plug for protection
against shock hazards. · Your air conditioner must be used in a properly
grounded wall receptacle. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or circuit breaker, have
a qualified electrician install the proper receptacle. · Do not run air
conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner. · Do not use an extension cord
or an adapter plug.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from the power cord.
115V 15A
230V 15A
230V 20A
230V 30A
Grounding Prong
Do not, under any circumstances, cut, remove or bypass the grounding prong.
Electrical Information
The complete electrical rating of your new room air conditioner is stated on
the serial plate. Refer to the rating when checking the electrical
requirements. · Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important.
4
IMPORTANT SAFETY INSTRUCTIONS
NOTE
The power supply cord with this air conditioner contains a current detection
device designed to reduce the risk of fire. Please refer to the section
`Operation of Current Device’ for details. In the event that the power supply
cord is damaged, it cannot be repaired. It must be replaced with a cord from
the product manufacturer.
SAFETY PRECAUTIONS
DANGER! Avoid Serious Injury or Death · This air conditioner contains no
user-serviceable parts. Always call an authorized Electrolux servicer for
repairs. · Do not insert or place fingers or objects into the air discharge
area in the front of the unit. · Do not start or stop the air conditioner by
unplugging the power cord or turning off the power at the electrical box. · Do
not cut or damage the power cord. · If the power cord is damaged, it should
only be replaced by an authorized Electrolux servicer. · In the event of a
malfunction (sparks, burning smell, etc.), immediately stop the operation,
disconnect the power cord, and call an authorized Electrolux servicer. · Do
not operate the air conditioner with wet hands. · Do not pull on the power
cord. · Do not drink any water that is drained from the air conditioner.
SAFETY PRECAUTIONS
CAUTION! Avoid Injury or damage to the unit or other property · Provide
ventilation per installation
instructions.
· Do not direct airflow at fireplaces or other heat related sources as this
could cause flare ups or make units run excessively.
· Do not climb on or place objects on outdoor part of the unit.
· Do not hang objects off the unit. · Do not place containers with liquids on
the
unit. · Turn off the air conditioner at the power
source when it will not be used for an extended period of time. · Periodically
check the condition of the unit’s installation accessories for any damage. ·
Do not apply heavy pressure to the radiator fins of the unit. · Operate the
unit with air filter in place. · Do not block or cover the intake grille,
discharge area and outlet ports. · Ensure that any electrical/electronic
equipment is one yard away from the unit. · Do not use or store flammable
gases near the unit. · Do not touch the metal parts of the unit when removing
the filter. Injuries can occur when handling sharp metal edges. · Do not use
water to clean inside the air conditioner. Exposure to water can destroy the
insulation, leading to possible electric shock. · When cleaning the unit,
first make sure that the power and circuit breaker are turned off.
CAUTION
· This appliance is not intended for use by persons (including children) with
reduced physical ,sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
· Children should be supervised to ensure that they do not play with the
appliance.
IMPORTANT SAFETY INSTRUCTIONS
5
· If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
· The appliance shall be installed in accordance with national wiring
regulations.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER. Unit must be
upright for one hour prior to operating.
Operation of Current Device
The power supply cord contains a current device that senses damage to the
power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner. 2. The power supply cord will have TWO
buttons on the plug head. Press the TEST button. You will notice a click as
the RESET button pops out. 3. Press the RESET button. Again you will notice a
click as the button engages. 4. The power supply cord is now supplying
electricity to the unit. (This is also indicated by a light on the plug head).
Plug in & press RESET
NOTE
· Do not use this device to turn the unit on or off.
· Always make sure the RESET button is pushed in for correct operation.
· The power supply cord must be replaced if it fails to reset when either the
TEST button is pushed, or it cannot be reset. A new one can be obtained from
the product manufacturer.
· If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced
by one obtained from the product manufacturer.
WARNING
FOR FLAMMABLE REFRIGERANT · Servicing shall only be performed as
recommended by the equipment manufacturer. Maintenance and repair requiring
the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of flammable refrigerants. · DO
NOT modify the length of the power cord or use an extension cord to power the
unit. · DO NOT share a single outlet with other electrical appliances.
Improper power supply can cause fire or electrical shock. · Please follow the
instruction carefully to handle, install, clear, service the air conditioner
to avoid any damage or hazard. · Flammable Refrigerant R32 is used within air
conditioner. When maintaining or disposing the air conditioner, the
refrigerant (R32) shall be recovered properly, shall not discharge to air
directly. · Compliance with national gas regulations shall be observed. · Keep
ventilation openings clear of obstruction. · The appliance shall be stored so
as to prevent mechanical damage from occurring.
6
IMPORTANT SAFETY INSTRUCTIONS
· A warning that the appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specified for operation.
· Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorises their competence to handle refrigerants
safely in accordance with an industry recognised assessment specification.
Examples for such working procedures are: · breaking into the refrigerating
circuit; · opening of sealed components; · opening of ventilated enclosures. ·
No any open fire or device like switch
which may generate spark/arcing shall be around air conditioner to avoid
causing ignition of the flammable refrigerant used. Please follow the
instruction carefully to store or maintain the air conditioner to prevent
mechanical damage from occurring. · Do not use means to accelerate the
defrosting process or to clean, other than those recommended by the
manufacturer. · The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an operating gas
appliance) and ignition sources or (for example: an operating electric heater)
close to the appliance. · Do not pierce or burn. · Be aware that the
refrigerants may not contain an odour.
1. Transport of equipment containing
flammable refrigerants.
See transport regulations.
2. Marking of equipment using signs
See local regulations.
3. Disposal of equipment using flammable
refrigerants
See national regulations.
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s
instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
6. Information on servicing
a) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
b)Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
c) General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
d)Checking for presence of refrigerant
The area shall be checked with an
appropriate refrigerating detector prior
to and during work, to ensure the
technician is aware of potentially
flammable atmospheres. Ensure that the
leak detection equipment being used is
suitable for use with flammable
refrigerants,
i.e.
non-sparking,
adequately sealed or intrinsically safe.
e) Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be
IMPORTANT SAFETY INSTRUCTIONS
7
available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the
charging area.
f) No ignition sources
No person carrying out work in relation to a refrigerating system which
involves exposing any pipe work that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing and disposal, during which flammable
refrigerant can possibly be released to the surrounding space. Prior to work
taking place, the area around the equipment is to be surveyed to make sure
that there are no flammable hazards or ignition risks. No Smoking signs shall
be displayed.
g)Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
h) Checks to the refrigerating equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult the
manufacturer’s technical department for assistance. The following checks shall
be applied to installations using flammable refrigerants: The actual
refrigerant charge is in accordance with the room size within which the
refrigerant containing parts are installed; The ventilation machinery and
outlets are operating adequately and are not obstructed; If an indirect
refrigerating circuit is being used, the secondary circuit shall be checked
for the presence of
refrigerant; Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected; Refrigerating pipe
or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components,
unless the components are constructed of materials which are inherently
resistant to being corroded or are suitably protected against being so
corroded.
i) Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment
so all parties are advised. Initial safety checks shall include: That
capacitors are discharged: this shall be done in a safe manner to avoid
possibility of sparking; That there no live electrical components and wiring
are exposed while charging, recovering or purging the system; That there is
continuity of earth bonding.
7. Repairs to sealed components
a) During repairs to sealed components, all electrical supplies shall be
disconnected from the equipment being worked upon prior to any removal of
sealed covers, etc. If it is absolutely necessary to have an electrical supply
to equipment during servicing, then a permanently operating form of leak
detection shall be located at the most critical point to warn of a potentially
hazardous situation.
b)Particular attention shall be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a way that
the level of protection is affected. This shall include damage to cables,
excessive number of
8
IMPORTANT SAFETY INSTRUCTIONS
connections, terminals not made to original specification, damage to seals,
incorrect fitting of glands, etc. Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no
longer serve the purpose of preventing the ingress of flammable atmospheres.
Replacement parts shall be in accordance with the manufacturer’s
specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types
of leak detection equipment. Intrinsically safe components do not have to be
isolated prior to working on them.
8. Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and current
permitted for the equipment in use. Intrinsically safe components are the only
types that can be worked on while live in the presence of a flammable
atmosphere. The test apparatus shall be at the correct rating. Replace
components only with parts specified by the manufacturer. Other parts may
result in the ignition of refrigerant in the atmosphere from a leak.
9. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
10.Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used.
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants. Electronic leak detectors shall be used to
detect flammable refrigerants, but the sensitivity may not be adequate, or may
need
re-calibration.
(Detection
equipment shall be calibrated in a
refrigerant-free area). Ensure that the
detector is not a potential source of
ignition and is suitable for the refrigerant
used. Leak detection equipment shall be
set at a percentage of the LFL of the
refrigerant and shall be calibrated to the
refrigerant employed and the appropriate
percentage of gas (25 % maximum) is
confirmed. Leak detection fluids are
suitable for use with most refrigerants but
the use of detergents containing chlorine
shall be avoided as the chlorine may react
with the refrigerant and corrode the
copper pipe-work. If a leak is suspected,
all naked flames shall be
removed/extinguished. If a leakage of
refrigerant is found which requires
brazing, all of the refrigerant shall be
recovered from the system, or isolated
(by means of shut off valves) in a part of
the system remote from the leak.
Removal of refrigerant shall be according
to Removal and evacuation.
11. Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purposeconventional procedures shall be used. However, for flammable refrigerants it is important that best practice be followed, since flammability is a consideration. The following procedure shall be adhered to:
a) safely remove refrigerant following local and national regulations;
b)purge the circuit with inert gas;
c) evacuate (optional for A2L);
d)purge with inert gas (optional for A2L);
e) open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders if venting is not allowed by local and national codes. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants. This process might need to be repeated several times. Compressed air or oxygen shall not be used for
IMPORTANT SAFETY INSTRUCTIONS
9
purging refrigerant systems. For appliances containing flammable refrigerants,
refrigerants purging shall be achieved by breaking the vacuum in the system
with oxygen-free nitrogen and continuing to fill until the working pressure is
achieved, then venting to atmosphere, and finally pulling down to a vacuum
(optional for A2L). This process shall be repeated until no refrigerant is
within the system (optional for A2L). When the final oxygen-free nitrogen
charge is used, the system shall be vented down to atmospheric pressure to
enable work to take place. Ensure that the outlet for the vacuum pump is not
close to any potential ignition sources and that ventilation is available.
12.Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed. Ensure that contamination of different refrigerants does
not occur when using charging equipment. Hoses or lines shall be as short as
possible to minimise the amount of refrigerant contained in them. Cylinders
shall be kept in an appropriate position according to the instructions. Ensure
that the refrigeration system is earthed prior to charging the system with
refrigerant. Label the system when charging is complete (if not already).
Extreme care shall be taken not to overfill the refrigeration system. Prior to
recharging the system it shall be pressure tested with OFN. The system shall
be leak tested on completion of charging but prior to commissioning. A follow
up leak test shall be carried out prior to leaving the site.
13. Decommissioning
Before carrying out this procedure, it is essential that the technician is
completely familiar with the equipment and all its detail. It is recommended
good practice that all refrigerants are recovered safely. Prior to the task
being carried out, an oil and refrigerant sample shall be taken in case
analysis is required prior to re-use of reclaimed refrigerant. It is essential
that
electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b)Isolate system electrically.
c) Before attempting the procedure ensure that: Mechanical handling equipment
is available, if required, for handling refrigerant cylinders; All personal
protective equipment is available and being used correctly; The recovery
process is supervised at all times by a competent person; Recovery equipment
and cylinders conform to the appropriate standards.
d)Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be
removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes
place.
g)Start the recovery machine and operate in accordance with instructions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even
temporarily.
j) When the cylinders have been filled correctly and the process completed,
make sure that the cylinders and the equipment are removed from site promptly
and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.
14. Labelling
Equipment shall be labelled stating that it has been de-commissioned and
emptied of refrigerant. The label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment contains flammable
refrigerant.
15. Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended
10 IMPORTANT SAFETY INSTRUCTIONS
good practice that all refrigerants are removed safely. When transferring
refrigerant into cylinders, ensure that only appropriate refrigerant recovery
cylinders are employed. Ensure that the correct number of cylinders for
holding the total system charge is available. All cylinders to be used are
designated for the recovered refrigerant and labelled for that refrigerant
(i.e. special cylinders for the recovery of refrigerant). Cylinders shall be
complete with pressure relief valve and associated shut-off valves in good
working order. Empty recovery cylinders are evacuated and, if possible, cooled
before recovery occurs.
The recovery equipment shall be in good working order with a set of
instructions concerning the equipment that is at hand and shall be suitable
for the recovery of flammable refrigerants. In addition, a set of calibrated
weighing scales shall be available and in good working order. Hoses shall be
complete with leak-free disconnect couplings and in good condition. Before
using the recovery machine, check that it is in satisfactory working order,
has been properly maintained and that any associated electrical components are
sealed to
prevent ignition in the event of a
refrigerant release. Consult manufacturer
if in doubt. The recovered refrigerant shall
be returned to the refrigerant supplier in
the correct recovery cylinder, and the
relevant Waste Transfer Note arranged.
Do not mix refrigerants in recovery units
and especially not in cylinders.
If compressors or compressor oils are to
be removed, ensure that they have been
evacuated to an acceptable level to make
certain that flammable refrigerant does
not remain within the lubricant. The
evacuation process shall be carried out
prior to returning the compressor to the
suppliers. Only electric heating to the
compressor body shall be employed to
accelerate this process. When oil is
drained from a system, it shall be carried
out safely.
Non-duct
connected
appliances
containing A2L refrigerants with the
supply and return air openings in the
conditioned space may have the body of
the appliance may be installed in open
areas such as false ceilings not being used
as return air plenums, as long as the
conditioned air does not directly
communicate with the air of the false
ceiling.
11 IMPORTANT SAFETY INSTRUCTIONS
CAUTION: Risk of fire flammable materials
IMPORTANT NOTE: Read this manual carefully before installing or operating your
new air conditioning unit. Make sure to save this manual for future reference.
CAUTION
This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that information is available such as the operating manual or installation manual.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
Wiring Diagram
DAHT SENSOR
CN7 OUT E. SENSOR CN10
OUT A. SENSOR CN9 CN8
CONTROL BOARD
FAN CAP BLUE
EVAPORATOR SENSOR CN4
AMBIENT SENSOR CN3
CN1
CN1
DISPLAY BOARD
YELLOW CN6
TRANSFORMER
BLUE BLACK FAN MOTOR
P10(P7) WHITE P3 YELLOW P2
RED P1
BLUE 34
CN5
P8
RY6N
BLUE/(WHITE)
CAPACITOR
Y/G
ION
Y/G
VALVE
RED P4 BLACK P6(P9)
GRAY(BLUE)
CN12 CN13
43
BLUE/(WHITE)
BLUE RED BLACK
FUSE
RY6L
RED
RED
RED CN11 CN2 CN14
BLUE BLACK RS
COMPRESSOR C
COM NO
COM/P4 P4 P2
P1
RY6N
RY6L
CN3
COM NO
GRAY(BLUE)
COM/P2
RELAY BOARD
BLACK(OR BROWN OR RED)
POWER WHITE(OR BLUE OR BLACK)
GREEN(OR Y/G)
RY7N RY7L HEATER CN14
CN1 DISPLAY CN2/(CN9) BOARD
WHITE 34 BLACK
RED 4 3 WiFi
WiFi
03722 HEATER
BOARD 160203000
NOTE: This symbol indicates the element is optional,the actual shape shall be prevail.
12 PACKAGING & NORMAL SOUNDS
Packaging
Remove all packaging from inside the carton, along with any inserts placed
into the side louvers. Remove the plastic ties and foam pad that secure the
compressor to the fan shroud (where applicable). See diagram.
foam pad + plastic ties Packing Inserts
Normal Sounds
3
4
2
1 Gurgle/Hiss “Gurgling or hissing” noise may be heard due to refrigerant
passing through evaporator during normal operation.
2 Sound of Rushing Air At the front of the unit, you may hear the sound of
rushing air being moved by the fan.
3 High pitched Chatter Today’s high efficiency compressors may have a high
pitched chatter during the cooling cycle.
4 Vibration Unit may vibrate and make noise because of poor wall or window
construction or incorrect installation.
5 Pinging or Swishing Droplets of water hitting condenser during normal
operation may cause “pinging or swishing” sounds. Note: Don’t try to drill any
holes on the base pan to eliminate the normal sounds, otherwise it will void
the warranty.
1
5
13 AIR CONDITIONER FEATURES
Air Conditioner Features
ELECTRONIC CONTROL Before you begin, thoroughly familiarize yourself with the
control panel and remote as shown below and all its functions, then follow the
symbol for the functions you desire. The unit can be controlled by the touch
pad alone or with the remote.
J
A
BC
D
A Turns Unit On Or Off B Eco Feature C Sleep Feature D Sets Mode E Displays Temperature/time
E
F
GH
I
F Sets Fan Speed
G Check Filter Reset Button
H Activates Timer
I
Remote Temp Sensing Indicator (Some Models)
J Adjusts Temperature Or Time
REMOTE CONTROL
STANDARD REMOTE
WITH DISPLAY & REMOTE
SENSING BUTTON
Light Feature: The display and all LED indicators on the control panel of the
unit can be turned off by pressing the “Light” button on the remote control.
If any other button of the control panel and remote control is pressed after
that, the unit will beep to indicate it works as the corresponding direction
of pressing specific button, and the display and LED indicators will
illuminate accordingly, but they will turn off again in 5 seconds if no
further operation. Press the “Light” button again or unplug the unit to cancel
this setting.
Battery Size: AAA Warning: Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
Caution for ingestion. Keep out of the reach of children.
14 OPERATING INSTRUCTIONS
NOTE
The following instructions represent the touch pad. The same instructions can
be used for the remote control.
TO TURN UNIT ON:
YOU WILL SEE:
Note: This mode is a fixed combination of Cool mode and Auto fan speed
setting. In this mode, the fan speed can not be selected manually. COOL
FEATURE:
DO THIS: PRESS ON/OFF BUTTON
YOU WILL SEE:
DO THIS:
PRESS MODE BUTTON CHOOSE COOL
NOTE: The unit will run in Cool mode with Eco feature and Auto fan speed
setting when used for the first time. With the Eco feature, when the room
temperature is below the set temperature, the fan will continue to run for 3
minutes after the compressor shuts off. The fan then cycles on for 2 minutes
at 10 minute intervals until the room temperature is above the set
temperature, at which time the compressor turns back on. Eco feature can be
activated or deactivated by pressing Eco button, but it is invalid in fan only
mode.
AUTO FEATURE:
YOU WILL SEE:
Note: In this mode, the fan remains on all the time with the compressor
cycling on and off when room temperature is reached. TO CHANGE TEMPERATURE
SETTlNG:
DO THIS:
PRESS MODE BUTTON CHOOSE AUTO
DO THIS: PRESS TO RAISE PRESS TO LOWER
YOU WILL SEE:
15 OPERATING INSTRUCTIONS
TO USE AUTO FAN FEATURE:
Note: Tap or hold either up ( ) or down ( ) button until the desired
temperature is seen on the display. This temperature will be automatically
maintained anywhere between 62 °F (17 °C) and 86 °F (30 °C). If you want the
display to read the actual room temperature. See “To Operate on Fan Only”
section.
TO ADJUST FAN SPEEDS:
DO THIS: PRESS FAN BUTTON,
CHOOSE AUTO
YOU WILL SEE:
DO THIS: PRESS TO SELECT
YOU WILL SEE:
Note: Fan starts at Low Speed and adjusts to a proper speed according to the
room temperature dictates. For example, if the room doesn’t get too warm, it
will stay at the slowest speed. If the room temperature rises quickly, such as
a door being opened, it will automatically go to the highest speed. The fan
speeds will re-adjust back to the slowest speed as the room returns to the
original set temperature.
TO OPERATE ON FAN ONLY:
Note: The fan speed can be selected among four settings: Auto, Lo(Low), Med(Medium) and Hi(High), unless the unit runs in “Auto” or “Dry” mode, or the Sleep feature is activated.
DO THIS:
PRESS MODE BUTTON CHOOSE FAN ONLY
16 OPERATING INSTRUCTIONS
YOU WILL SEE:
SLEEP FEATURE:
Note: Use this function only when cooling is not desired, such as for room air
circulation or to exhaust stale air on some models. (Remember to open the vent
during this function, but keep it closed during cooling for maximum cooling
efficiency.) You can choose any fan speed you prefer. During this function,
the display will show the actual room temperature, not the set temperature as
in the cooling mode.
DRY MODE:
DO THIS: PRESS SLEEP
BUTTON
YOU WILL SEE:
DO THIS: PRESS MODE BUTTON
CHOOSE DRY
YOU WILL SEE:
Note: In this mode, the unit will select Auto fan speed automatically, and the
selected temperature will increase by 2 °F 30 minutes after the mode is
selected. The temperature will then increase by another 2 °F after an
additional 30 minutes. This new temperature will be maintained for 7 hours
before it returns to the originally selected temperature. This ends the
“Sleep” mode and the unit will continue to operate as originally programmed.
The “Sleep” mode program can be cancelled at any time during operation by
again pressing the “Sleep”, “Fan speed” or “Mode” button.
CHECK FILTER FEATURE, YOU WILL SEE:
Note: In this mode, the air conditioner will work like a dehumidifier, but it will cool the room down meanwhile. The temperature can be adjusted between 62 °F (17 °C) and 86 °F (30 °C) and fan speed will be held at “Lo”.
Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Filter Reset” button and the light will go off.
17 OPERATING INSTRUCTIONS
DO THIS: PRESS FILTER RESET BUTTON
TIMER: DELAY STOP/START FEATURE:
THEN DO THIS:
PRESS UP/DOWN BUTTONS
FIRST DO THIS:
PRESS TIMER BUTTON
YOU WILL SEE HOW MUCH TIME IS CHOSEN:
To delay stop(or start), press the Timer button when the unit is power-on(or power-off), then the “timer off” indicator(or “timer on” indicator) will illuminate. Then adjust timer setting, tap or hold the UP arrow ( ) or the DOWN arrow ( ) to change delay timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The setting will be confirmed automatically in 5 seconds, then the control will count down the time(8, 7.5, 7, etc.) left, and all other settings will remain the same as they were before the timer setting is confirmed, until stop(or start).
Setting combination of “delay stop turn off delay start” or “delay start turn
on delay stop” is workable. Both “timer off” indicator and “timer on”
indicator will illuminate then. The timer setting can be canceled by either
pressing and holding the timer button for 2 seconds, or pressing the power
on/off button at any time to turn off the unit directly.
REMOTE SENSING FEATURE (on some models): This feature can be activated from
the remote control ONLY, the unit must be in a cooling mode. To activate the
remote sensing feature, point the remote control towards the unit and press
the Remote Sensing button. Next, use the ” ” buttons to set the desired
temperature at the remote. (Note that the set temperature will only be
displayed on the unit itself ). The LIGHT on the unit control will illuminate
to indicate it receives the signal. The LIGHT on the remote control will pulse
each time it sends a signal. lt will periodically send this signal until the
feature is deactivated by pressing the remote sensing button again. lf the
unit does not receive the remote sensing signal during any 7 minute interval,
the Remote Sensing feature will halt until the unit receives signal from the
remote control again. The display on the remote control indicates the
temperature at the remote ONLY.
DO THIS: PRESS REMOTE SENSING BUTTON
18 OPERATING INSTRUCTIONS
YOU WILL SEE:
TO TURN UNIT OFF:
Remote Sensing indicator NOTE: Unit display shows the set temperature. Remote
display is actual temperature. The Remote Sensing function can be terminated
either by pressing the Remote Sensing button again or the main ON/OFF button
on the unit.
TO CHANGE TEMPERATURE DISPLAY:
DO THIS: PRESS ON/OFF BUTTON
YOU WILL SEE:
FAULT CODES:
DO THIS: PRESS AND HOLD THE UP/DOWN
BUTTONS SIMULTANEOUSLY FOR 3 SECONDS
YOU WILL SEE:
Note: The control is capable of displaying temperature in degrees Fahrenheit
or degrees Celsius.
If the display reads “AS” , a sensor has failed. Contact your Authorized
Frigidaire Service Center.
ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating
procedure, here are more features in your control that you should become
familiar with.
NOTE
The “Cool” circuit has an automatic 3 minute time delayed start if the unit is
turned off and on quickly. This prevents overheating of the compressor and
possible circuit breaker tripping. The fan will continue to run during this
time.
19 OPERATING INSTRUCTIONS
· There is a 2-Second delay for the compressor shutting down when selecting
FAN ONLY. This is to cover the possibility of having to roll through to select
another mode.
· The control will maintain the set temperature within 2 degrees Fahrenheit,
between 60°F and 90°F degrees.
· After a power outage, the unit will memorize the last setting and return the
unit to the same setting once power is restored.
· The unit should be operated in a temperature range of indoor side 60°F 90°F
(16°C – 32°C), outdoor side 64°F 109°F (18°C – 43°C). Performance may be
reduced outside of these operating temperatures.
Fresh Air Vent Control (on some models)
The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air – Vent Closed (see Fig. 1)
2. Draw fresh air into the room – Fresh Air (see Fig. 2)
3. Exchange air from the room – Vent Open (see Fig. 3)
Figure 3 (VENT OPEN)
Air Directional Louvers Air directional louvers control air flow direction.
Your air conditioner has the louver type described below.
Slider Type The louvers will allow you to direct the air flow Up or Down and
Left or Right throughout the room as needed. Drag the adjuster tablet until
the desired Left/Right direction is obtained. Pivot horizontal louvers until
the desired Up/Down direction is obtained.
ADJUSTER TABLET
(6-WAY)
Figure 1 (VENT CLOSED)
Figure 2 (FRESH AIR)
20CARE AND CLEANING & ENERGY SAVING IDEAS
Clean your air conditioner occasionally to keep it looking new. Be sure to
unplug the unit before cleaning to prevent shock or fire hazards. Air Filter
Cleaning The air filter should be checked at least once a month to see if
cleaning is necessary. Trapped particles in the filter can build up and cause
an accumulation of frost on the cooling coils. · Push the vent handle to the
Vent Closed
position(where applicable). · Open the front panel. · Grasp the filter by the
center and pull up
and out. · Wash the filter using liquid dishwashing
detergent and warm water. Rinse filter thoroughly. Gently shake excess water
from the filter. Be sure filter is thoroughly dry before replacing. · Or
instead of washing, you may vacuum the filter clean. NOTE: When replacing the
air filter after cleaning, make sure the tabs on the air filter are on the
upper part of filter, and placed outward as shown in the drawing on the left
side.
Tab
Air Filter
Cabinet Cleaning · Be sure to unplug the air conditioner to
prevent shock or fire hazard. The cabinet and front may be dusted with an oil-
free cloth or washed with a cloth dampened in a solution of warm water and
mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. · Never use
harsh cleaners, wax or polish on the cabinet front. · Be sure to wring excess
water from the cloth before wiping around the controls. Excess water in or
around the controls may cause damage to the air conditioner. · Plug in air
conditioner.
Winter Storage
If you plan to store the air conditioner during the winter, remove it
carefully from the window according to the installation instructions. Cover it
with plastic or return it to the original carton.
Energy Saving Ideas
· Do not block air flow inside with blinds, curtains or furniture; or outside
with
shrubs, enclosures, or other buildings. · The capacity of the room air
conditioner
must fit the room size for efficient and satisfactory operation. · Install the
room air conditioner on the shady side of your home. A window that faces north
is best because it is shaded most of the day. · Close the fireplace damper,
floor and wall registers so cool air does not escape up the chimney and into
the duct work. · Keep blinds and drapes in other windows closed during the
sunniest part of the day. · Clean the air filter as recommended in the section
“Care and Cleaning”. · Proper insulation and weather stripping in your home
will help keep warm air out and cool air in. · External house shading with
trees, plants or awnings will help reduce the air conditioner’s work load. ·
Operate heat producing appliances such as ranges, washers, dryers and
dishwashers during the coolest part of the day.
21 BEFORE YOU CALL
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
OCCURRENCE
Air conditioner will not operate.
SOLUTION
· Wall plug disconnected. Push plug firmly into wall outlet. · Plug Current
Device Tripped. Press the RESET button. · House fuse blown or circuit breaker
tripped. Replace fuse with time delay
type or reset circuit breaker. · Control is OFF. Turn Control ON and set to
desired setting.
Air from unit does not feel cold enough.
Air conditioner cooling, but room is too warm – ice forming on cooling coil
behind decorative front
Air conditioner cooling, but room is too warm – NO ice forming on cooling coil
behind decorative front.
Air conditioner turns on and off rapidly.
Noise when unit is cooling.
· Room temperature below 60°F (16°C). Cooling may not occur until room
temperature rises above 60°F (16°C).
· Temperature sensing element touching cold coil, located behind air filter.
Straighten away from coil.
· Reset to a lower temperature. · Compressor shut-off by changing modes. Wait
approximately 3 minutes
and listen for compressor to restart when set in the COOL mode.
· Outdoor temperature below 60 F° (16°C). To defrost the coil, set FAN ONLY
mode.
· Air filter may be dirty. Clean filter. Refer to Care and Cleaning section.
To defrost, set to FAN ONLY mode.
· Temperature is set too low for night-time cooling. To defrost the coil, set
to FAN ONLY mode. Then, set temperature to a higher setting.
· Dirty air filter – air restricted. Clean air filter. Refer to Care and
Cleaning section.
· Temperature is set too high. Set temperature to a lower setting. · Air
directional louvers positioned improperly. Position louvers for better air
distribution. · Front of unit is blocked by drapes, blinds, furniture, etc. –
restricts air
distribution. Clear blockage in front of unit. · Doors, windows, registers,
etc. open – cool air escapes. Close doors,
windows, registers, etc. · Unit recently turned on in hot room. Allow
additional time to remove
“stored heat” from walls, ceiling, floor and furniture.
· Dirty air filter – air restricted. Clean air filter. · Outside temperature
extremely hot. Set FAN speed to a faster setting to
bring air through cooling coils more frequently.
· Air movement sound. This is normal. If too loud, set to lower FAN setting. ·
Window vibration – poor installation. Refer to installation instructions or
check with installer.
Water dripping INSIDE when unit is cooling.
· Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions or check with installer.
22 BEFORE YOU CALL
OCCURRENCE SOLUTION
Water dripping OUTSIDE when unit is cooling.
· Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.
Remote Sensing Deactivating Prematurely (some models).
· Remote control not located within range. Place remote control within 20 feet
& 120° radius of the front of the unit.
· Remote control signal obstructed. Remove obstruction.
Room too cold.
· Set temperature too low. lncrease set temperature.
· Remote Sensing activated (on some models) and remote control located in Hot
Spot – Relocate remote control or deactivate remote sensing.
If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire Service.
23 MAJOR APPLIANCE LIMITED WARRANTY
Your appliance is covered by a limited one-year warranty for functional repairs only. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions. After one year from your original date of purchase, the consumer will be responsible for diagnostic, labor and parts costs as well as any removal, transportation and reinstallation expenses which are incurred during service on components.
Exclusions
This warranty does not cover the following: 1. Products with original serial
numbers that have been removed, altered or cannot be readily determined. 2.
Product that has been transferred from its original owner to another party or
removed outside the USA or Canada. 3. Rust on the interior or exterior of the
unit. 4. Products purchased “as-is” are not covered by this warranty. 5. Food
loss due to any refrigerator or freezer failures. 6. Products used in a
commercial setting. 7. Service calls which do not involve malfunction or
defects in materials or workmanship, or for appliances not in ordinary
household use or used other than in accordance with the provided instructions.
8. Service calls to correct the installation of your appliance or to instruct
you how to use your appliance. 9. Expenses for making the appliance accessible
for servicing, such as removal of trim, cupboards, shelves, etc., which are
not a part of the appliance when it is shipped from the factory. 10. Service
calls to repair or replace appliance light bulbs, air filters, water filters,
other consumables, or knobs, handles, or other cosmetic parts. 11. Surcharges
including, but not limited to, any after hour, weekend, or holiday service
calls, tolls, ferry trip charges, or mileage expense for service calls to
remote areas, including the state of Alaska. 12. Damages to the finish of
appliance or home incurred during installation, including but not limited to
floors, cabinets, walls, etc. 13. Damages caused by: services performed by
unauthorized service companies; use of parts other than genuine Electrolux
parts or parts obtained from persons other than authorized service companies;
or external causes such as abuse, misuse, inadequate power supply, accidents,
fires, or acts of God.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY
LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL
EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY
IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE
DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT
APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
If You Need Keep your receipt, delivery slip, or some other appropriate payment record to establish the
Service
warranty period should service be required. If service is performed, it is in your best interest to
obtain and keep all receipts. Service under this warranty must be obtained by contacting
Electrolux at the addresses or phone numbers below.
This limited warranty only applies in the USA and Canada. In the USA, your appliance is warranted by
Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your
appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any
obligations under this warranty. Obligations for service and parts under this warranty must be performed by
Electrolux or an authorized service company. Product features or specifications as described or illustrated are
subject to change without notice.
USA 1.800.944.9044 Electrolux Major Appliances 10200 David Taylor Drive Charlotte, NC 28262
Canada
1.800.265.8352
Electrolux Canada Corp. 5855 Terry Fox Way
Mississauga, Ontario, Canada L5V 3E4
home welcome
Our home is your home. Visit us if you need help with any of these things:
owner support accessories service registration
(See your registration card for more information.) Frigidaire.com
1-800-944-9044 Frigidaire.ca
1-800-265-8352
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>