DREXIA RS-H0-06P BZ MS RFID Reader Instruction Manual
- August 31, 2024
- DREXIA
Table of Contents
- RS-H0-06P BZ MS RFID Reader
- Specifications
- Product Usage Instructions
- Before Use
- Data Format and Operation
- Maintenance and Troubleshooting
- Installation and Connection
- Q: How can I change the input voltage range or cable length of
- Q: What should I do if the RFID reader is not reading the
- Q: Can the RFID reader be mounted on metal surfaces?
RS-H0-06P BZ MS RFID Reader
Specifications
-
Power supply: 12 V DC (8-16 VDC) and 24V DC
(20-30 VDC) -
Power supply efficiency: 1 A
-
Peak current: 150 mA
-
Average receiver current: 30 mA (without
LED) -
Peak receiver current: 50 mA
-
Green LED current: 6 mA
-
Red LED current: 6 mA
-
Buzzer current: 35 mA
-
Peak Buzzer current: 70 mA
-
Frequency: 13.56 MHz
-
Type of transponder: ISO/IEC14443-3-A,
ISO/IEC14443-3-B, ISO 15693, Felica, iClass, ISO 18092
Product Usage Instructions
Before Use
1. Do not open the reader or make any changes to avoid loss of
warranty.
2. Contact customer support for any questions or issues.
3. Be cautious of metal surfaces that can affect radio
communication; consult with staff regarding mounting
conditions.
Data Format and Operation
1. The RFID reader reads identification data wirelessly from
passive transponders compatible with various standards.
2. The built-in LEDs and Buzzer indicate successful reads or
errors during operation.
3. Data is sent as ASCII strings via UART open collector, with
specific formats for different UID lengths.
Maintenance and Troubleshooting
1. Keep the reader clean and free from dust or debris to ensure
proper functionality.
2. In case of damaged products, contact customer support for
assistance.
Installation and Connection
1. Connect the reader according to the provided scheme to ensure
proper functionality.
2. Contact customer support for customization options such as
input voltage range or cable length.
FAQ
Q: How can I change the input voltage range or cable length of
the RFID reader?
A: Contact our customer support team before making an order to
discuss and determine the details for customization.
Q: What should I do if the RFID reader is not reading the
transponders correctly?
A: Ensure the reader is clean and free from obstructions.
Contact customer support for further troubleshooting steps.
Q: Can the RFID reader be mounted on metal surfaces?
A: Metal surfaces can affect radio communication and reader
operation. Consult with our staff for mounting conditions suitable
for metal surfaces.
RS-H0-06P BZ MS
RFID reader | 13.56 MHz | Multi System FCC ID: 2BEXQRSH006PBZMS1 Made in
Poland
Product Card
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
Before use…
Please do not open the reader and do not make any changes. This results in
loss of warranty. In case of any questions please contact with us. We
certainly answer to all questions and solve possible problems. Please
carefully read the following information before connecting the reader.
Please keep in mind, that there are factors as metal surfaces, which can
affect on radio communication and correct reader operation. It is advisable to
consult the mounting conditions before use with our staff.
Please contact with us before sending damaged products.
We offer possibility to change input voltage range, cable length and terminate
it with a plug. Before making an order, please contact with us to determine
the details.
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
General information
The RFID reader RS-H0-06P BZ MS reads identification data (UID) wireless of passive transponders (cards, tags, etc.) compatible with ISO/IEC14443-3-A (e.g. MIFARE cards), ISO/IEC14443-3-B, ISO 15659, Felica, iClass, ISO 18092.
The built-in two-color LED and Buzzer for any use.
LEDs are powered by internal voltage regulator via built-in resistors. The light is on when the appropriate LED is connected to the minus of power supply.
BUZZER is activated when appropriate BUZZER output is connected to the minus of power supply.
Black power supply (-)
Yellow power supply (+)
Green green LED
Red
red LED
White TX
Blue Buzzer
The reader should be connected according to the scheme:
SCHEME
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
Data format
The read data are sent as ASCII string via UART open collector. For
transponder UIDs of 4 bytes, ASCII string of 12 sings is sent. While, for UIDs
of 7 or 10 bytes, string of 18 or 24 bytes is sent.
For example, for UID of 4 bytes, data is sent in following order:
START
0x0A (LF)
UID [3]
UID [2…1]
UID [0]
Checksum CRC
2 ASCII signs 4 ASCII signs 2 ASCII signs 2 ASCII sgins
MSB
LSB MSB
LSB MSB
LSB MSB
LSB
STOP
0x0D (CR)
Byte START and byte STOP help us identify the string we are receiving. Checksum is calculated as the XOR function of data read from the transponder.
For example: For card with UID = 10DB8274 CRC = (10h) XOR (DBh) XOR (82h) XOR (74h)=3Dh
the following string will be output:
LF
1
0
D
B
8
2
7
4
3
D
CR
0x0A 0x31 0x30 0x44 0x42 0x38 0x32 0x37 0x34 0x33 0x44 0x0D
The reader is waiting for the proximity of the token (card) trying to read it. Each re-read attempt is made in cycles every 500ms. After correct reading of the identifier, ASCII characters are sent via the UART open collector interface.
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
External dimensions
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
Technical Data
Power supply Power supply efficiency Peak current Average receiver current
Peak receiver current Green LED current Red LED current Buzzer current Peak
Buzzer current Frequency Type of transponder
Surface of the antenna Reading range Reading frequency UART
Mounting method Cable length Reader temperature
ROHS
12 V DC (8-16 VDC) and 24V DC (20-30 VDC) 1 A 150 mA 30 mA (without LED)
50 mA
6 mA 6 mA 35 mA 70 mA 13,56 MHz ISO/IEC14443-3-A, ISO/IEC14443-3-B, ISO 15693,
Felica, iClass, ISO 18092
8,6 cm2 3-7 cm depending on token 2/s TTL open collector, active state 0,
9600 bps, 8 bits, without parity and 1 stop bit (8N1).
tape, glue, etc.
0,4 m (flat cable) -20o C +55o C
YES
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
FCC Information
FCC Radio Product Manual
FCC Information
This device complies with Part 15 of the FCC Results. Operation is subject to
the following two conditions:
(1) This Device may not cause harmful interface, and
(2)This Device must accept any interference received, including interference
that may cause undesired operation.
Note : This equipment has been tested and found to comply with the limits for
CLASS B digital device, pursuant to Part 15 FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try correct the
interference by one or more of the following measures ; 1.1. Reorient or
relocate the receiving antenna. 1.2. Increase the separation between the
equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit
different from that to
which receiver is connected. 1.4. Consult the dealer or experienced radio/TV
technician for help.
WARNING
Changes or modifications not expressly approved by the manufacturer could void
the user’s authority to operate the equipment.
CAUTION : Exposure to Radio Frequency Radiation.( If not subject to
measurement SAR)
To comply with FCC’s RF exposure limits for general population / uncontrolled
exposure, the antenna(s) used for this transmitter must be installed to
provide a separation distance of at
least 20cm from all persons and must not be co-located or operating in
conjunction with any
other antenna or transmitter.
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
LABEL
The following label was attached to collective packaging for many pieces of
RFID readers:
The following label was attached to product: FCC ID: 2BEXQRSH006PBZMS1
DREXIA Tomasz Wojtasik ul. Ekonomiczna 30 93-426 Lód www.drexia.pl
biuro@drexia.pl
RS-H0-06P BZ MS Product Card
06-02-2024
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>