ZKTECO 7 Series Multi Biometric Access Control Terminals User Guide
- August 30, 2024
- ZKTECO
Table of Contents
ZKTECO 7 Series Multi Biometric Access Control Terminals
Specifications
- Product: SenseFace 7 Series
- Version: 1.0
- Screen Size: 7-inch touch screen
- Components: Speaker, Camera, Microphone, Near-Infrared Flash,
Fingerprint Sensor, Card Reading Area, USB Interface, Reset
Product Usage Instructions
Installation Environment:
Install indoors only. Avoid installation near glass windows,direct
sunlight exposure, and any heat sources near the device.
Device Installation:
- Attach the mounting template sticker to the wall and drill holes according to the template.
- Fix the backplate on the wall using mounting screws.
- Pass the wires through the wiring hole and connect them to the device.
- Snap the device onto the backplate and push it down into place.
- Fasten the device to the backplate with a security screw.
Standalone Installation:
Connect devices like Door Sensor, Wiegand Card Reader, RS485 Lock Reader,
Exit Button, Smoke Detector, Wireless Doorbell, TCP/IP using the provided
terminal block connections.
Ethernet Connection:
Establish a connection between the device and software using an Ethernet
cable. Set IP addresses according to the provided guidelines.
Power Connection:
Use an AC Adapter DC12V, 3A for power. Ensure compatibility with other
connected devices.
Exit Button, Door Sensor & Auxiliary Connection:
Connect the Exit Button, Door Sensor, and Auxiliary according to the
provided connections.
RS485 Connection:
Connect devices like Door Sensor and RS485 Reader using the specified
connections.
Lock Relay Connection
The system supports both Normally Opened Lock and Normally Closed Lock.
Connect accordingly based on power sharing with the lock.
Wiegand Reader Connection:
Connection instructions for Wiegand Reader are not provided in this
extract.
FAQ
-
Q: What should I do if the product does not power on?
A: Check the power connections and ensure the AC adapter is functioning properly. Contact customer support if issues persist. -
Q: Can I install the device outdoors?
A: No, the device is designed for indoor installation only to avoid environmental damages.
Quick Start Guide
SenseFace 7 Series
Version: 1.0
Overview
SenseFace 7A / 7C
SenseFace 7B
Note: Not all products have the function with , the real product shall prevail.
Installation Environment
Device Installation
Install on the wall
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the backplate on the wall with the wall mounting screws.
- After passing the wires through the wiring hole and connecting them to the device, and then snap the device onto the backplate and push it down into place. Fasten the device to the backplate with a security screw.
Standalone Installation
Terminal Block
Ethernet Connection
Establish the connection between the device and the software using an Ethernet cable. An illustrative example is provided below:
Tap on to enter the main menu. And then click on [Comm.] > [Ethernet] > [IP
Address] to input the IP address.
Note: In LAN, IP addresses of the server (PC) and the device must be in
the same network segment when connecting to the software.
Power Connection
Exit Button, Door Sensor & Auxiliary Connection
RS485 Connection
Lock Relay Connection
The system supports both Normally Opened Lock and Normally Closed Lock. The
NO LOCK (normally opened at power on) is connected with ‘NO’ and ‘COM’
terminals, and the NC LOCK (normally closed at power on) is connected with
‘NC’ and ‘COM’ terminals. Take NC Lock as an example below:
- Device not sharing power with the lock
- Device sharing power with the lock
Wiegand Reader Connection
Note: The Wiegand interface is shared, and the user can choose to use either the Wiegand input or Wiegand output function to interface with different Wiegand devices.
User Registration
Click to enter the Main Menu screen. When a super administrator is set up, administrator verification is required when entering the menu. For security purposes, it is recommended to register a super administrator when using it for the first time.
Method 1: Registering on the device
Click > [User Mgt.] > [New User] to register a new user. The options include
entering the user ID and Name, setting User Role and Access Control Role,
registering Face, Fingerprint, Card Number, Password and Profile Photo.
Method 2: Register on ZKBio CVAccess software
Please set the IP address and cloud service server address in the COMM. menu
option on the device.
- Click [Access] > [Access Device] > [Device] > [Search] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.
- Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.
- Click [Access] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.
- For more details, please refer to the ZKBio CVAccess User Manual.
Method 3: Register on the phone
Once the ZKBio CVAccess software is installed, the users could enroll their
face via a browser application on their own mobile phone.
- Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code URL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address: Port/app/v1/adreg’’ by the mobile phone to register users.
- The users will be displayed in [Personnel] > [ Pending Review].
Ethernet and Cloud Server Settings
Click > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP
communication of the device is successful, the icon will be displayed in the
upper right corner of the standby interface.
Click > [COMM.] > [Cloud Server Setting] to set the server address and server
port, that is, the IP address and port number of the server after the software
is installed. If the device communicates with the server successfully, the
icon will be displayed in the upper right corner of the standby interface.
Note: While pairing the device with ZKBio CVAccess software. Make sure that the option Enable Domain Name is disabled and the correct server address and port are entered.
Configuring Wi-Fi
Click > [COMM.] > [Wi-Fi Settings] to configuring Wi-Fi. When Wi-Fi is
enabled, select the searched network. Enter the password, and click Connect to
Wi-Fi (OK). The connection succeeds, with icon displayed on the status bar.
You can also select Add Wi-Fi Network to add Wi-Fi manually. Connect the
Wireless Doorbell
This function needs to be used with the wireless doorbell.
First, power on the wireless doorbell. Then, press and hold the music button
for 1.5 seconds until the indicator flashes to indicate it’s in pairing mode.
After that, click on the device icon , if the wireless doorbell rings and the
indicator flashes, it means the connection is successful.
After a successful pairing, clicking the icon of the device will ring the
wireless doorbell.
Note: Generally, each device connects to one wireless doorbell.
SIP Settings
Setting call options on the device
Click >[Intercom] > [SIP Settings] > [Call Options] to set the SIP common
parameters.
Mode 1: Local Area Network
Note: When the SIP Server function is enabled, the Contact List menu are
not displayed. To use Contact List, turn off the SIP Server.
Calling by IP Address
-
Set the IP address on the indoor station, Tap [Menu] > [Advanced] > [Network] > [1. Network] > [1. IPv4].
Note : Indoor station IP address and the device IP address must be in the same network segment. -
Click icon on the standby page to enter the call page, users can call the IP address of the indoor station.
Calling by Shortcut
- Click >[Intercom] > [SIP Settings] > [Contact List].
- Click [Add], input device number and call address to add a new contact member. Note: Call address and the device must be in the same network segment.
- Click [SIP Settings] > [Calling Shortcut Settings], select any item except admin, and enter the form information you just uploaded.
- Then you can enter the device number or click shortcut key in the call screen to directly implement the video intercom.
Direct Calling Mode
Click >[Intercom] > [SIP Settings] > [Contact List].
Click [Add], input device number and call address to add a new contact member.
Note: Call address and the device must be in the same network segment.
Click [SIP Settings] > [Calling Shortcut Settings] > [Call Mode] > [Direct
Calling Mode] > [Add]. Select the IP addresses of the indoor stations that you
want to call, then the indoor stations will be displayed in the list.
Then you can tap the icon on the device to call the indoor stations at the
same time.
Mode 2: SIP Server
- Click >[Intercom] > [SIP Settings] > [Local Settings] to enable the SIP server.
- Click [Master Account Setting] / [Backup Account Setting] to set the SIP server parameters.
- Click icon on the standby page to enter the call page, once the SIP is set up correctly, a green dot will appear in the upper right corner of the call page to indicate that the device is connected to the server. You can call the account name of the indoor station.
Note: When users need to enable SIP server, they need to purchase the server address and password from the distributor, or build the server confidently.
ONVIF Settings
This function needs to be used with the Network Video Recorder (NVR).
- Set the device to the same network segment as the NVR.
- Click > [Intercom] > [ONVIF Settings] to set the User Name and Password. Note: If the Authentication function is disabled, then there is no need to input the User Name and Password when adding the device to the NVR.
- On the NVR system, click [Start] > [Menu] > [Channel Manage] > [Add Channel] [Refresh] to search for the device.
- Select the checkbox for the device you want to add and edit the parameters in the corresponding text field, then click on [OK] to add it to the connection list.
- After successfully adding, the video image obtaining from the device can be viewed in real-time. For more details, please refer to the NVR User Manual.
ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan,
China.
Phone : +86 769 – 82109991
Fax : +86 755 – 89602394
www.zkteco.com
Copyright 2024 ZKTECO CO., LTD. All Rights Reserved.