CONCEPTRONIC ZEUS05E ZEUS09E Series Battery and Surge Protected Schuko
Product Specifications
- Model: ZEUS05E (650VA 360W) / ZEUS09E (850VA 490W)
- USB Port: Included (ZEUS09E)
Product Usage Instructions
Installation
Follow these steps to install the UPS unit.
- Place the UPS unit in a well-ventilated area.
- Connect the power cord of your devices to the appropriate outlets on the UPS.
- For ZEUS09E, connect your computer’s USB port to the UPS unit using the provided USB cable.
- Plug the UPS into a power source and turn it on.
USB Port Usage (ZEUS09E):
The USB port on the ZEUS09E allows for communication between the UPS unit and your computer.
Follow these steps:
- Connect one end of the USB cable to the UPS unit’s USB port.
- Connect the other end of the USB cable to your computer’s USB port.
- Install any necessary software or drivers for UPS communication if prompted.
- Your computer should now be able to communicate with the UPS unit via the USB connection.
Frequently Asked Questions
Q: What should I do if my UPS unit is not powering on?
A: If your UPS unit is not powering on, check the power source, ensure all connections are secure, and verify that the power switch is in the correct position. If issues persist, contact customer support for assistance.
Package contents
- The following items are present in the package of the Conceptronic UPS.
- UPS
- Multi-language quick installation guide
Specifications
- Capacity: 650VA 360W (ZEUS05E) ; 850VA 490W (ZEUS09E)
Product Overview
- Power On/Off Switch
- LED Indicators
- Battery Backup & Surge Protected Outlets
- Provide battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.
- Surge Protected Outlets
- Provide surge protection for bypass output.
- Input power cord
- Modem/LAN Internet Protection (RJ45 &RJ11)
- Communication protection ports will protect any standard modem, fax, telephone line, or network cable.
- Input Circuit Breaker
- The Circuit Breaker provides optimal overload protection.
- USB port (ZEUS09E)
- This port allows connection and communication from the USB port on the computer to the UPS unit.
Definitions for illuminated LED indicators
Installation & usage
How to determine the power requirements of your equipment
- Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment do not exceed rated capacity.
- Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the UPS unit’s rated capacity.
- If the rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
Hardware installation guide
- Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
- With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive), etc. into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder, or other large electrical device into the battery power-supplied outlets. The power demands of these devices will overload and possibly damage the unit.
- Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.
- Press the power switch to turn the unit on. The power on the indicator light will illuminate and the unit will “beep”.
- If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power-supplied outlets. Wait 10 seconds. Make sure the circuit breaker/fuse is normal and then turn the UPS on.
- Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically recharge.
- To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
- To store your UPS for an extended period, cover it and store it with the battery fully charged. Recharge the battery every three months to ensure battery life.
- Software Installation on your PC Power Master+ management software provides a user-friendly interface for your power systems.
- The graphic user interface is intuitive and displays essential power information at a glance. Please follow the procedure below to install the software.
Installation procedure:
- Download Power Master+ from the website: http://www.powermonitor.software/
- Double-click the file and follow the installation steps. When your computer restarts, the Power Master+ software will appear as a blue icon located in the system tray.
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
The UPS does not perform the expected runtime | Batteries are not fully | |
charged. | Recharge the battery by leaving the UPS plugged in. | |
The UPS will not turn on | The on/off switch is designed to prevent damage by | |
rapidly turning it off and on. | Turn the UPS off. Wait 10 seconds and then |
turn the UPS on.
The outlets stop providing power to equipment.
The circuit breaker button is projecting from the side of the unit.| A circuit
breaker is tripped due to an overload| Turn the UPS off and unplug at least
one piece of equipment. Reset the circuit breaker by pressing the button, and
then turn the UPS on.
Caution:
- To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area, free of conductive contaminants.
- Risk of electric shock, do not remove the cover. No user-serviceable parts. Refer servicing to qualified service personnel.
- Risk of electric shock, hazardous live parts inside this UPS can be energized from the battery supply even when the input AC power is disconnected.
- Risk of electric shock, The Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and the ground. Test before touching.
- Use the power supply only in a socket that is installed as close as possible to the device and easily accessible and easy to unplug.
- To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
- To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as space heaters or furnaces.
- Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
- Do not plug the UPS input into its output.
- Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
- In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
- Do not attach a power strip or surge suppressor to the UPS.
- Unplug the UPS before cleaning and do not use liquid or spray detergent.
- Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
- The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.
- When replacing the batteries, use the same number and type of batteries.
- Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolytes are harmful to the skin and eyes.
- Do not plug the power supply into a socket that is hidden behind any furniture.
- Do not cover the power supply connected to the socket.
- Use the product only in dry indoor rooms and protect it from moisture.
- If in doubt or if the power adapter malfunctions, discontinue use and contact our customer support or an authorized service center.
- Discontinue use immediately if the power adapter shows visible damage, emits unusual odors, or becomes excessively hot.
- Note: This manual contains important safety instructions. Please follow all instructions carefully during installation. Read this manual thoroughly before attempting to unpack, install, or operate. The UPS is designed to be for use with computer loads only.
- Note: Disposal of waste electrical equipment and batteries: Do not dispose of waste electrical equipment and batteries with household waste. Please hand them to your local recycling point. Batteries should be fully discharged when disposed of. Incorrect storage/disposal can harm the environment and/or cause injury.
- CE marking: Conceptronic declares that this product complies with the directives listed in the section ‘Declaration of Conformity.
- Need Help?
- support@conceptronic.net
- www.conceptronic.net
- Digital Data Communications GmbH – Im Defdahl 10 F, 44141 Dortmund, Germany CONCEPTRONIC® is a registered trademark of Digital Data Communications GmbH © Copyright Digital Data Communications GmbH. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>