CONCEPTRONIC ZEUS52E Dubbele Conversie UPS Installation Guide

August 29, 2024
CONCEPTRONIC

CONCEPTRONIC ZEUS52E Dubbele Conversie UP

Product Information

Specifications:

  • Model: ZEUS52E / ZEUS52ES
  • Includes: UPS x1, User’s manual x1, Input power cord (EU/UK) x2, USB cable x1, RS232 cable x1

Product Usage Instructions

  1. Unboxing and Setup
    When unboxing the product, ensure all components are included as listed in the specifications. Place the UPS in a well-ventilated area near your devices.

  2. Connecting Power
    Connect the input power cord to a suitable power outlet. Ensure the UPS is switched off before plugging it in.

  3. Device Connection
    Connect your devices to the UPS using the provided USB and RS232 cables. Make sure to follow the user manual instructions for proper device connections.

  4. Powering On
    After all connections are secure, power on the UPS using the designated power button.

  5. Monitoring and Maintenance
    Regularly check the UPS for any alerts or notifications regarding power supply status. Refer to the user manual for maintenance guidelines.

FAQ

  • Q: What should I do if the UPS shows a fault indicator?
    A: If the UPS displays a fault indicator, first check the connections and ensure the input power source is stable. If the issue persists, contact customer support for assistance.

  • Q: Can I plug non-essential devices into the UPS?
    A: It is recommended to prioritize essential devices when connecting to the UPS to ensure uninterrupted power supply during outages.

  • Q: How often should I perform maintenance on the UPS?
    A: Regular maintenance checks should be conducted according to the guidelines provided in the user manual. Typically, a quarterly inspection is advisable.

ZEUS52E ZEUS52ES
Quick Installation Guide

Guide Installation Rapide

This Quick Installation Guide provides essential information for basic setup. For detailed instructions and additional features, please refer to the comprehensive user manual available for download on the Conceptronic website: www.conceptronic.net. Please read and follow all instructions carefully during the installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate the UPS.

  • CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to power-drain this equipment, turn off and unplug the unit. CAUTION! The battery can power hazardous components inside the unit, even when the AC input power is disconnected.
  • CAUTION! The UPS should be placed near the connected equipment and easily accessible.
  • CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
  • CAUTION! (No User Serviceable Parts): Risk of electric shock, do not remove cover. No user-serviceable parts inside. Refer servicing to qualified service personnel.
  • CAUTION! (Non-Isolated Battery Supply): Risk of electric shock, battery circuit is not isolated from AC power source; hazardous voltage may exist between battery terminals and ground. Test before touching.
  • CAUTION! To reduce the risk of fire, connect the UPS to a branch circuit with 10 amperes (1 K / 2K) / 16 amperes (3K) maximum overcurrent protection in accordance to CE requirements.
  • CAUTION! The AC outlet where the UPS is connected should be close to the unit and easily accessible.
  • CAUTION! Please use only VOE-tested, CE-marked mains cable, (e.g. the mains cable of your equipment), to connect the UPS to the AC outlet.
  • CAUTION! Please use only VOE-tested, CE-marked power cables to connect any equipment to the UPS.
  • CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the connected equipment does not exceed 3.5mA. CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective ground insulation.
  • CAUTION! To avoid electric shock, tum off and unplug the unit before installing the input/output power cord with a ground wire. Connect the ground wire prior to connecting the line wires!
  • CAUTION! Do not use an improper-sized power cord as it may cause damage to your equipment and cause fire hazards.
  • CAUTION! Wiring must be done by qualified personnel.
  • CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Under no circumstances this unit should be used for medical applications involving life support equipment and/or patient care.
  • CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out. CAUTION! Do not dispose of batteries in fire as the battery may explode. CAUTION! Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes.
  • CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working on batteries
    1. Remove watches, rings or other metal objects.
    2. Use tools with insulated handles.
  • CAUTION! The unit has a dangerous amount of voltage. When the UPS indicators is on, the units may continue to supply power thus the unit’s outlets may have a dangerous amount of voltage even when it’s not plugged in to the wall outlet. CAUTION! Make sure everything is turned off and disconnected completely before conducting any maintenance, repairs or shipment.
  • CAUTION! Connect the Protection Earth (PE) safety conductor before any other cables are connected.
  • WARNING! (Fuses): To reduce the risk of fire, replace only with the same type and rating of fuse.
  • DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE!
  • DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
  • DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS OUTPUT SOCKETS!
  • SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY PERSONNEL KNOWLEDGE OF BATTERIES AND THE REQUIRED PRECAUTIONS. KEEP UNAUTHORIZED PERSONNEL AWAY FROM  BATTERIES!

Disposal of waste electrical equipment and batteries:

Do not dispose of waste electrical equipment and batteries with household waste. Please hand them to your local recycling point. Batteries should be fully discharged when disposed of. Incorrect storage/disposal can harm the environment and/or cause injury.
CE marking: Conceptronic declares that this product complies with the directives listed in the section ‘Declaration of Conformity’.UNPACKING ****

UNPACKING

  1. UPSx1;
  2.  User’s manual x1;
  3. Input power cord (EU/UK) x2;
  4.  USB cable x1;
  5.  RS232 cable x1

POWER MODULE FRONT/REAR PANEL DESCRIPTION

  1.  Power On/Off Button
    Master ON/OFF for the UPS.

  2.  Function Buttons
    Scroll up, scroll down, select and cancel LCD menu.

  3.  Multifunction LCD Readout
    Indicate status information, settings and events.

  4. Battery Backup & Surge Protected Outlets
    Provide battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.

  5.  Serial Port
    Serial port provides communication between the UPS and the computer. The UPS can control the computer’s shutdown during a power outage through the connectionwhile the computer can monitor the UPS and alter its various programmable parameters.

  6.  EPO (Emergency Power Off) Connector
    Enable Power-Off in emergency from a remote location.

  7.  use port
    This is a connectivity port which allows communication and control between the UPS and the connected computer. It is recommended to install the Power master software on the PC/Server connected with the USB cord.

  8. SN MP/HTTP Network slot
    Slot to install the optional SNMP card for remote network control and monitoring.

  9. AC Input Inlet
    Connect the AC Power cord to a properly wired and grounded outlet.

  10.  Input Circuit Breaker
    Provide input overload and fault protection.

  11. . Extended Runtime Battery Module Connector(only for long run models) Connect to additional external battery modules.

  12. Output Terminal Block
    Connect to your equipment.

INSTALLING YOUR UPS SYSTEM

HARDWARE INSTALLATION

  1. Battery charge loss may occur during shipping and storage. Before using the UPS, it’s strongly recommended to charge batteries for four hours to ensure the batteries’ maximum charge capacity. To recharge the batteries, simply plug the UPS into an AC outlet.

  2. Connect your computer, monitor, and any externally powered data storage device (Hard drive, Tape drive, etc.) into the outlets only when the UPS is off and unplugged. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS. The power demands of these devices will overload and possibly damage the unit.

  3. To protect a fax machine, telephone, modem line or network cable, connect the telephone or network cable from the wall jack outlet to the jack marked “IN” on the UPS and connect a telephone cable or network cable from the jack marked “OUT” on the UPS to the modem, computer, telephone, fax machine, or network device.

  4. Press the ON switch to turn the UPS on. If an overload is detected, an audible alarm will sound and the UPS will continuously emit one beep per second. For resetting the unit, unplug some equipment from the outlets. Make sure your equipment carries a load current within the unit’s safe range, (refer to the technical specifications).

  5. This UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge, even when the unit is switched off.

  6. To maintain an optimal battery charge, leave the UPS plugged into an AC outlet at all times.

  7. Before storing the UPS for an extended period of time, turn the unit OFF. Then cover it and store it with the batteries fully charged. Recharge the batteries every three months to ensure good battery capacity and long battery life. Maintaining a good battery charge will help prevent possible damage to the unit from battery leakage.

  8. The UPS has one USB port (default) and one Serial port that allows connection and communication between the UPS and any attached computer running the Power Master software. The UPS can control the computer’s shutdown during a power outage through the connection while the computer can monitor the UPS and alter various programmable parameters.
    Note: Only one communication port can be used at a time. The port not in use will automatically become disabled or the serial port will be disabled if both ports are attached.

  9. To avoid electric shock, turn the unit OFF and disconnect the unit from utility power before hardwiring the UPS (in/out power cord). The in/out power cord MUST be grounded.

SOFTWARE INSTALLATION

Power Master+ management software provides a user-friendly interface for your power systems. The graphic user interface is intuitive and displays essential power information at a glance. Please follow the procedure below to install the software.


Installation procedure:

  1. Download Power Master+ from the website: https://www.powermonitor.software/
  2. Double-click the file and follow the installation steps. When your computer restarts, the Power Master+ software will appear as a blue icon located in the system tray.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CONCEPTRONIC User Manuals

Related Manuals