ENTTEC NA1 NEON FLEX Led Light Strip Installation Guide
- August 26, 2024
- ENTTEC
Table of Contents
- ENTTEC NA1 NEON FLEX Led Light Strip
- Specifications
- Product Information
- Product Usage Instructions
- FAQ
- Safety
- Physical Dimensions
- Wiring Application
- Mounting Installation
- Servicing, Inspection & Maintenance
- Ordering Information
- CONTACT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ENTTEC NA1 NEON FLEX Led Light Strip
Specifications
- Product Name: NEON FLEX NA1, NA2, NA3
- Model Number: 73060
- Type: Horizontal/Vertical bendable weatherproof Neon Flex LED strip
Product Information
- The NEON FLEX NA1, NA2, NA3 is a weatherproof Neon Flex LED strip that can be bent horizontally or vertically.
- It is designed for both indoor and outdoor use, providing vibrant lighting solutions for various applications.
- For the latest information and updates, visit the ENTTEC website.
Product Usage Instructions
- Ensure familiarity with all key information in the guide and other relevant ENTTEC documentation.
- Install the product according to national and local electrical codes by a qualified individual.
- Use overvoltage protection to prevent damage.
- Check power distribution equipment and cables before applying power.
- Isolate the installation if any component is damaged, defective, or wet.
- Adhere to maximum length limitations and product specifications.
- Avoid exceeding ratings and limitations to prevent fire or electrical faults.
- Avoid hot-swapping Neon Flex or accessories.
- Ensure the Earth wire is always connected.
- Check power and data connections for correct polarity and secure attachment.
- Do not reverse polarity when connecting from both ends.
- Test connections with a multi-meter before applying power.
- Consider using cable ferrules for non-tinned cable connections.
Always comply with local electrical and building regulations. If in doubt, seek guidance from a local distributor.
FAQ
- Q: Can I install the NEON FLEX NA1, NA2, NA3 outdoors?
- A: Yes, the Neon Flex LED strip is weatherproof and suitable for outdoor use. Ensure proper installation following the provided guidelines.
- Q: What should I do if I notice any damage to the Neon Flex or accessories?
- A: Immediately isolate the installation from power and contact ENTTEC or your supplier for further assistance.
- Q: Is it necessary to use cable ferrules when connecting non-tinned cables?
- A: While not mandatory, using cable ferrules can improve connection reliability and is recommended by ENTTEC for non-tinned cable connections.
Safety
- Ensure you are familiarised with all key information within this guide and other relevant ENTTEC documentation before specifying, installing, or operating an ENTTEC device. If you are in any doubt about system safety, or plan to install an ENTTEC device in a configuration not covered within this guide, contact ENTTEC or your ENTTEC supplier for assistance.
- ENTTEC’s return to base warranty for this product does not cover damage caused by inappropriate use, application, or modification to the product.
Electrical Safety
- This product must be installed by applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
- This device can be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system may reduce the risk of damage.
- Provide a means of locking out AC mains power to the installation to be shut down and make it impossible to reapply accidentally.
- Before applying power to the installation, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices and factor in overhead.
- Isolate the installation from power immediately if Neon Flex, accessories power cables or connectors is in any way damaged, defective, show signs of overheating or is wet (if not an IP67 component).
- Adhere to the maximum length limitations for Neon Flex and accessories as specified in the guide and product documentation.
- To reduce the risk of fire or electrical faults do not exceed the ratings and limitations defined in the product datasheet or this guide.
- Do not hot-swap Neon Flex or accessories.
- Shut down power to the installation during cleaning in addition to when the system is not in use.
- Always comply with local electrical and building regulations. If you have any uncertainties, seek support from a local distributor for guidance and assistance.
- This device operates on DC power and excludes an earth connection.
- The Earth wire MUST ALWAYS be connected.
- Always make sure that the power and data connections are connected correctly and securely.
- Do not reserve polarity when connecting from both ends.
- Always test connections with a multi-meter before applying power.
- ENTTEC recommends the use of cable ferrules when connecting non-tinned cables.
System Planning and Specification
- Please refer to the product datasheet and installation guide to determine the light output and cable required for your installation before initiating your system design.
- For best practice keep all cable run lengths to a minimum to avoid electrical noise.
- Avoid running data cabling close to mains power or devices that emit electromagnetic noise (i.e. air conditioning units).
Protection from Injury During Installation
- Always use suitable personal protective equipment when installing ENTTEC products.
- When installing the Neon Flex above ground level, ensure that the installation hardware and supporting structure can hold the weight of all the devices they support.
- In an overhead installation or where the Neon Flex system may cause injury if it falls. Block access below the work area and work from a stable platform whenever installing, servicing or moving the Neon Flex system.
- Once installation is completed, check that all hardware and components are securely in place and fastened to supporting structures.
Installation Safety and Guidelines
Always work with a plan of installation that respects all system limitations
as defined within this guide and adheres to the safety information.
- Ensure proper data flow by following the directions indicated on the Neon Flex.
- Avoid covering Neon Flex with any insulating material.
- Take care not to apply tension on the cabling while installing Neon Flex or accessories.
- Qualified personnel should perform the installation, and professional consultation is advised when unsure.
- Power connections should not be made until all installation work is complete.
- Do not install Neon Flex if the cabling is damaged.
- Verify the operating voltage and frequency compatibility before connecting Neon Flex to a power supply.
- Avoid crushing or clamping Neon Flex or accessory cabling during installation.
- Protect connections and avoid leaving them exposed or disconnected in damp environments.
- Handle Neon Flex strips only when they are not energized.
- Prevent short circuits by ensuring connectors and accessory cabling are positioned safely.
- Ensure proper restraint and secure installation of Neon Flex and accessory cabling before system sign-off.
- Confirm the surface’s weight-bearing capacity before attaching Neon Flex and accessories.
- For outdoor installations, employ corrosion-proof and rated fixings.
- Avoid bending Neon Flex into curves with diameters less than 80mm (3.15in).
- Maintain a minimum distance of 0.5m from combustible surfaces.
- Avoid overstretching Neon Flex cabling sections.
- Do not operate Neon Flex in temperatures exceeding 50°C (122°F).
- Ensure sufficient airflow for convection cooling of Neon Flex units.
- Avoid covering or enclosing Neon Flex without proper heat dissipation methods.
- Keep the device out of direct sunlight whenever possible for optimum operating temperature.
- Do not modify the Neon Flex system in any way.
- Use a flat and solid surface for the supporting structure.
- Verify the suitability of mounting positions and surfaces with a qualified person.
- Ensure secure installation with all necessary safety anchors.
- Avoid routing the product onto rough surfaces or sharp corners that may damage its finish.
- Do not use the product if the finish is damaged, there are loose electrical connections, or the wires are visible without insulation.
- Avoid installing the product in pools used by humans.
- Prohibit excessive pulling or bending force during installation.
- Always use the product with an electrical isolation transformer providing Safety Extra Low Voltage (SELV).
- Consider all limiting factors before finalizing the system design and adhere to the lowest applicable limit.
Physical Dimensions
Neon Flex
Female Connector
Male Connector
Wiring Application
-
ENTTEC offers various products to control Neon Flex, each designed for different use case scenarios and its control protocol.
-
Wiring application for non-addressing single color (NA1), Tuneable White (NA2), RGBW (NA3) by using ENTTEC CVC4 auto-addressable 4-channel LED dimmer as below:
-
To see the full range of ENTTEC lighting controllers, please visit www.enttec.com for the latest information.
Electrical Connections
- ENTTEC Neon Flex is a made-to-order product with the finish of the product specifically molded to provide optimal weatherproof performance.
- Specifications including lengths of the Neon Flex, cable lengths, connector style, and type are necessary before placing an order.
- Female or male connectors with cable can be ordered separately in various lengths.
- It is recommended to ensure the feeder cable is long enough to reach the cable entry point of flex where connection can be made.
- Do not cut the Neon Flex and the waterproof connectors. DIY cutting of this product will void the warranty.
- Tighten the female and male connectors with pliers when installing to ensure there are no gaps.
NA1, NA2, NA3 Wiring Diagram
- The ENTTEC CVC4 is an auto-addressable 4-channel constant voltage LED dimmer designed for non-addressable Neon Flex lighting. Depending on the channel needs, several non-addressable Neon Flex units can be linked to a single CVC4.
- For managing your non-addressable Neon Flex, connect multiple CVC4 units in a daisy chain to any ENTTEC DMX or PIXELATOR Series controllers. Visit the CVC4 page on enttec.com to explore versatile wiring options.
Voltage Drop
- The longer the distance between the power source and the Neon Flex, the greater the voltage drop. Excessive voltage drop can lead to reduced brightness and color shifting.
- The power supply should be located as close as physically possible to the beginning of the Neon Flex to minimize the effect of voltage drop.
- For optimum performance and to reduce the impact of voltage drop, ENTTEC recommends the use of multiple smaller DC power supplies at the beginning of each run of Neon Flex, instead of a low quantity of high-capacity power supplies with longer connection cables.
- The power supply unit is not supplied with the product. ENTTEC recommends IP67-rated or higher power supplies where applicable to your installation requirement.
- If you are concerned about the voltage drop and the impact on your installation, contact the ENTTEC team or your reseller.
- The maximum run length of the customizable Neon Flex is an essential factor to consider for installations in terms of voltage drop.
- Refer datasheet or consult a local distributor for the maximum run length of each Neon Flex variant.
Mounting Installation
Neon Flex is an incredibly durable product; however, it must be installed following the provided picture guide. It is essential to have at least two people during the installation process to support the product at various locations as shown in the guide. It is crucial to exercise caution during installation and ensure that the bending radius of the Neon Flex is not exceeded.
-
Install Neon Flex within the specified temperature range to ensure proper bonding and flexibility. Operating outside this range may compromise performance.
-
Do not use staples, nails, or any other sharp objects that may damage the silicone insulation when securing the product.
-
Always use ENTTEC mounting accessories for mounting installation. Mounting accessories order information can be found at the end of the document and the product datasheet.
-
Install the screw into position and make sure that the screw head is flush or recessed below the base of the aluminum profile.
-
Ensure that the mounting accessories are properly aligned and that the joint is smooth and seamless. Any displacement of the profiles can result in incorrect bending of the product, which may cause damage over time.
-
Mounting accessories are available in different lengths to accommodate various installation needs. When cutting aluminum accessories, use appropriate tools while prioritizing safety. Ensure that the cutting surface is neat and smooth to prevent any damage to the product’s finish.
-
Avoid using glues and resins as fixing agents. The use of glues and resins may void the warranty unless explicitly specified otherwise.
-
Maintain a minimum distance of 10mm between the aluminum mounting piece and the end cap or connectors. This spacing ensures proper installation and functionality.
-
When inserting the Neon Flex into the mounted aluminum channel, ensure that it is inserted in the correct direction. Incorrect installation may result in light failure or malfunction.
-
To maintain the waterproof performance of the connector, it is important to avoid bending the Neon Flex against the light terminal. Make sure to keep a minimum distance of 100mm before shaping the Neon Flex. This will help prevent any potential damage or compromise to the waterproof seal of the connector.
-
Ensure that the feeding cable does not bear any force and allows for a 10mm lead with a loose configuration. This will help prevent any strain or stress on the cable, ensuring optimal performance and longevity.
-
Use an IP-rated waterproof junction box to mount the cable junction in outdoor applications for a hermetic enclosure and added protection.
-
Each fixing option serves a specific purpose, but if there is any uncertainty, it is recommended to contact technical support for further assistance.
Servicing, Inspection & Maintenance
- Servicing, inspection & maintenance should only be carried out by qualified technicians familiar with all safety information within this document and the Neon Flex system.
- Neon Flex and accessories have no user-serviceable parts. If your installation has become damaged, parts should be replaced.
- Power down the entire system and ensure a method is in place to stop the system from becoming energized during Servicing, Inspection & Maintenance.
Key areas to examine during the inspection
- Ensure all connectors are mated securely and show no sign of damage.
- Ensure all connectors show no sign of corrosion.
- Ensure all cabling has not obtained physical damage or been crushed.
- Ensure all Neon Flex and accessories are secured to the surface and have been installed by the guidelines set out within the installation guide.
- Check for dust or dirt build-up on the Neon Flex System and schedule cleaning if necessary. – Dirt or dust buildup can limit the ability of the Neon Flex system to dissipate heat and can lead to damage.
- If deemed necessary for a Neon Flex or accessory to be replaced, it should be removed in a reverse order to installation as defined in this guide.
- The replacement strip or accessory should be an appropriate size and be installed by all steps within the installation guide.
- To order replacement parts contact your reseller or ENTTEC directly.
Cleaning
Dust and dirt buildup can limit the ability of the Neon Flex system to
dissipate heat resulting in damage. The Neon Flex system must be cleaned in a
schedule fit for the environment it is installed within to ensure maximum
product longevity.
Cleaning schedules will vary greatly depending on the operating environment of
your Neon Flex. Generally, the more extreme the environment, the shorter the
interval between cleanings.
- Before cleaning, power down the system and ensure a method is in place to stop the system from becoming energized until cleaning is complete.
- Do not use abrasive, corrosive or solvent-based cleaning products on a Neon Flex system.
- Do not spray Neon Flex or accessories with a high-pressure water jet.
To clean an ENTTEC Neon Flex system, use low-pressure compressed air to remove
dust, dirt, and loose particles. If deemed necessary, wipe the Neon Flex with
a damp microfiber cloth.
A selection of environmental factors that may increase demand for frequent
cleaning include:
- Use of stage fog, smoke or atmospheric devices.
- High airflow rates (i.e. near air conditioning vents).
- High pollution levels or cigarette smoke.
- Airborne dust (from building work, the natural environment or pyrotechnic effects).
- If any of these factors are present, inspect all elements of the system soon after installation to see whether cleaning is necessary, then check again at frequent intervals. This procedure will allow you to determine a reliable cleaning schedule for your installation.
Ordering Information
Neon Flex
Product | SKU |
---|---|
Neon Flex | 73060 |
Neon Flex Accessories
Product | SKU |
---|---|
Aluminium Mounting Accessory – Straight Linear (S1&S3) | 1000mm – 73061 |
Aluminium Mounting Accessory – Curved (S1&S3) | 500mm – 73062 |
1000mm – 73063
Aluminium Mounting Accessory – Straight Linear (S2&S4)| 1000mm – 73072
Aluminium Mounting Accessory – Curved (S2&S4)| 1000mm – 73073
Plastic Mounting Accessory – Straight Linear (S5)| 1000mm – 73074
Plastic Mounting Accessory – unit (S5)| 30mm – 73075
2Pin – Male Connector with cable (2m)| 73077
2Pin – Female Connector with Cable (2m)| 73078
2Pin – Extension Cable (2m)| 73079
3Pin – Male Connector with cable (2m)| 73065
3Pin – Female Connector with Cable (2m)| 73066
3Pin – Extension Cable (2m)| 73067
5Pin – Male Connector with cable (2m)| 73069
5Pin – Female Connector with Cable (2m)| 73070
5Pin – Extension Cable (2m)| 73071
Please contact the ENTTEC team to discuss the customization options available.
CONTACT
- Neon Flex – NA1, NA2, NA3 (73060)
- Visit the ENTTEC website for the latest version
- MELBOURNE AUS / LONDON UK / RALEIGH-DURHAM USA / DUBAI UAE
- Due to constant innovation, information within this document is subject to change.
- enttec.com ID: 5951130
References
- ENTTEC | Lighting control experts : ENTTEC
- ENTTEC | Lighting control experts : ENTTEC
- ENTTEC | Lighting control experts : ENTTEC
Read User Manual Online (PDF format)