PowerUC SCT023R 50A Split Core Current Transformer
Specifications
- Model: SCT023R
- Input Current: 50mA – 100mA
- Output Current: 20mA – 100mA
- Turns Ratio: 1:1000 – 1:6000
- Accuracy: 0.5%
- Sampling Resistance: 10 – 100
FAQs
- Q: Can the product be used with higher input currents?
- A: The product specifications indicate the recommended input current range. Using currents outside this range may affect performance and accuracy.
- Q: Is it possible to modify the device for specific applications?
- A: As stated in the product manual, modifications to the device may void the warranty and are not recommended without prior consultation with the manufacturer.
Installation Diagram
Primary threading method(firing line)
- Open the buckle
- Open upward
- Put in lead wire
- Fasten the buckle
Characteristic
- Safety lock buckle, easy installation
- Cable output
- The length can be customized
- Free hanging (In-Line) Mounting
Product Application
- Portable instrument
- Household metering
- Monitoring the load of the machine
Product advantage
- Small volume, Lightweight
- Low cost
- High turns, high precision
Typical Technical Index
- Material of core Laminated silicon steel
- Working voltage Phase voltage≤720V
- Working temperature 30 C ~+65C
- Storage temperature 40C~+85 C
- Frequency range 50Hz~ 60Hz
- Waterproof grade IP00
- Dielectric strength Input (bare conductor) /output AC 800V/1 min 5mA 50Hz output/outer shell AC 3.5KV/1min 5mA 50Hz)
- Weight 103g
Electrical Parameters
The following parameters are typical values. The actual values shall be subject to the actual measurement of the product)
Statement:
As our products are constantly being improved and updated, we reserve the right to modify the content of this specification at any time without prior notice.
Dimensions
Dimensions: (in:mm‡0.5)