FireBlitz FHN800HIA Hard Hearing System User Guide

August 24, 2024
FireBlitz

FHN800HIA Hard Hearing System

“`html

Product Information

Specifications:

  • Product Name: FHN800HIA Hard of Hearing System
  • Model Number: 8174 V1.0
  • Compatible Alarms: FireHawk RF-Link Smoke Alarms, Heat Alarms,
    Carbon Monoxide Alarms, Mains Smoke and Heat Alarms

Product Usage Instructions

1. Connect

Apply power supply to the Control Unit to turn it on. Plug in
vibrating pads for vibration alerts or use the strobe light option
without pads. Ensure the device is not linked to any alarm devices
initially.

2. Alarm Assembly

Switch on alarm radio bases and connect them to alarms for
power. The LED will flash red twice then stop flashing once
connected.

3. Linking

Press the LINK BUTTON on the Control Unit to enter Linking mode.
Put each alarm device in Linking mode one by one until all alarms
are linked.

4. Linked Alarms Ready for Installation

Press the TEST BUTTON on the Control Unit to test each linked
alarm and perform a self-hardware test. Install the alarms and
retest to ensure they are in range.

5. Linking Additional Alarms

To add new alarms to an existing system, repeat steps for each
new alarm. If multiple Control Units are used, repeat linking
process for each unit.

6. Device Reset

To reset the Control Unit, press and hold the Link Button until
all lights flash sequentially. Press the Link button again to reset
the device to factory settings. For alarm pattress reset, hold down
the white RF button until the light turns RED.

FAQ

Q: How do I know if an alarm device is successfully

linked?

A: The FHN800HIA will flash yellow to indicate a new device has
been linked. Additionally, each linked alarm will sound when the
TEST BUTTON is pressed on the Control Unit.

Q: What should I do if a faulty alarm is detected during

testing?

A: If a faulty alarm is detected, troubleshoot by retesting each
device individually to identify the problematic unit. Contact
customer support if issues persist.

“`

Pairing Guide
Hard of Hearing System
FHN800HIA
READ & RETAIN THESE PAIRING INSTRUCTIONS

8174 V1.0

COMPATIBLE ALARMS
This Hearing Impaired System can be radio linked (wirelessly) to all FireHawk RF-Link Smoke Alarms (FHB10-RF), Heat Alarms (FHH10-RF), Carbon Monoxide Alarms (CO10-RF), RF-Link equipped Mains Smoke and Heat Alarms (fitted with FHN600RF RF-Link module) and one other Hearing Impaired Control Unit (FHN800HIA).
1. CONNECT
1.1 Apply the power supply to the Control Unit to turn on the device, the green power light will activate. If the Control Unit is not linked to any alarm devices the fault light will be on withing a few seconds of powering the unit. Plug-in one or two vibrating pads or none at all for the strobe light only option. This is important as the device will learn this configuration and trigger a fault if any pad is disconnected or damaged.
2. ALARM ASSEMBLY
2.0 Switch on alarm radio bases, the LED will flash green, if not please see step 6 to reset device. Connect the radio bases to alarms for power. They will beep once and the LED will flash red twice then stop flashing.

3. LINKING
3.1 Press the LINK BUTTON on the Control Unit, it will flash green and red indicating it is in Linking mode.
3.2 Put the next device in Linking mode, it will flash red and green for a short time and will beep and stop flashing its lights when linked to the Control Unit. The FHN800HIA will flash yellow to indicate a new device has been linked.
IMPORTANT: The first time an alarm device is used it can be put into linking mode by pressing the test button on connected alarm. If an alarm device has already been paired to a system and it is being linked to a second Control Unit, use the internal RF button to access linking mode.
3.3 Repeat for each alarm in the system.
3.4 Once all alarms are linked, press the “Link” button on the Control Unit to exit the linking process.
4. LINKED ALARMS READY FOR INSTALLATION
4.1 Press the TEST BUTTON on the Control Unit, each Linked alarm will sound and the Control Unit will perform a self-hardware test. (Due to signal timings each alarm may trigger at the same time making it difficult to detect a faulty alarm).
4.2 Please perform a test from each device in the system to ensure every alarm is successfully linked.
4.3 Install the alarms then retest to ensure the devices are in range.

5. LINKING ADDITIONAL ALARMS
5.1 To add a new alarm to an existing system complete step 2, 3 & 4 for all new alarms.
If multiple Control Units are used in a system, step 3 must be repeated for at each Control Unit and all alarms MUST BE linked to it. Use the internal RF button on the alarm device to access linking mode.
6. DEVICE RESET
6.1 To reset the Control Units (FHN800HIA) press and hold the “Link” Button until all lights will flash sequentially, press the “Link” button again to reset the device. This will blink all lights and return the device to factory settings.
6.2 To reset an Alarm Pattress and restore factory settings, Open the alarm device and hold down the white RF button until the light turns RED. This will restore factory settings and unlink all devices, the light will flash green twice per second.
7. REMOVING LINKED DEVICE
7.1 Press the “Clear” Button to enter Unlinking mode, the yellow fault light and the red fire Light will flash.
7.2 Put the device to be removed into Linking mode, by pressing the RF button, the green and red light will flash for a short time and the device will beep once removed.
7.3 Exit Unlinking mode by pressing the “Reset” Button.
Fireblitz Extinguisher Ltd. Units 15-17 Manford Industrial Estate,
Manor Road. Erith, Kent DA8 2AJ
Telephone: 01322 342238 TECHNICAL HELPLINE 0800 008 6568