Product Information
Specifications:
- Product Name: FHN800HIA Hard of Hearing System
- Model Number: 8174 V1.0
- Compatible Alarms: FireHawk RF-Link Smoke Alarms, Heat Alarms,
Carbon Monoxide Alarms, Mains Smoke and Heat Alarms
Product Usage Instructions
1. Connect
Apply power supply to the Control Unit to turn it on. Plug in
vibrating pads for vibration alerts or use the strobe light option
without pads. Ensure the device is not linked to any alarm devices
initially.
2. Alarm Assembly
Switch on alarm radio bases and connect them to alarms for
power. The LED will flash red twice then stop flashing once
connected.
3. Linking
Press the LINK BUTTON on the Control Unit to enter Linking mode.
Put each alarm device in Linking mode one by one until all alarms
are linked.
4. Linked Alarms Ready for Installation
Press the TEST BUTTON on the Control Unit to test each linked
alarm and perform a self-hardware test. Install the alarms and
retest to ensure they are in range.
5. Linking Additional Alarms
To add new alarms to an existing system, repeat steps for each
new alarm. If multiple Control Units are used, repeat linking
process for each unit.
6. Device Reset
To reset the Control Unit, press and hold the Link Button until
all lights flash sequentially. Press the Link button again to reset
the device to factory settings. For alarm pattress reset, hold down
the white RF button until the light turns RED.
FAQ
Q: How do I know if an alarm device is successfully
linked?
A: The FHN800HIA will flash yellow to indicate a new device has
been linked. Additionally, each linked alarm will sound when the
TEST BUTTON is pressed on the Control Unit.
Q: What should I do if a faulty alarm is detected during
testing?
A: If a faulty alarm is detected, troubleshoot by retesting each
device individually to identify the problematic unit. Contact
customer support if issues persist.
“`
Pairing Guide
Hard of Hearing System
FHN800HIA
READ & RETAIN THESE PAIRING INSTRUCTIONS
8174 V1.0
COMPATIBLE ALARMS
This Hearing Impaired System can be radio linked (wirelessly) to all FireHawk
RF-Link Smoke Alarms (FHB10-RF), Heat Alarms (FHH10-RF), Carbon Monoxide
Alarms (CO10-RF), RF-Link equipped Mains Smoke and Heat Alarms (fitted with
FHN600RF RF-Link module) and one other Hearing Impaired Control Unit
(FHN800HIA).
1. CONNECT
1.1 Apply the power supply to the Control Unit to turn on the device, the
green power light will activate. If the Control Unit is not linked to any
alarm devices the fault light will be on withing a few seconds of powering the
unit. Plug-in one or two vibrating pads or none at all for the strobe light
only option. This is important as the device will learn this configuration and
trigger a fault if any pad is disconnected or damaged.
2. ALARM ASSEMBLY
2.0 Switch on alarm radio bases, the LED will flash green, if not please see
step 6 to reset device. Connect the radio bases to alarms for power. They will
beep once and the LED will flash red twice then stop flashing.
3. LINKING
3.1 Press the LINK BUTTON on the Control Unit, it will flash green and red
indicating it is in Linking mode.
3.2 Put the next device in Linking mode, it will flash red and green for a
short time and will beep and stop flashing its lights when linked to the
Control Unit. The FHN800HIA will flash yellow to indicate a new device has
been linked.
IMPORTANT: The first time an alarm device is used it can be put into linking
mode by pressing the test button on connected alarm. If an alarm device has
already been paired to a system and it is being linked to a second Control
Unit, use the internal RF button to access linking mode.
3.3 Repeat for each alarm in the system.
3.4 Once all alarms are linked, press the “Link” button on the Control Unit to
exit the linking process.
4. LINKED ALARMS READY FOR INSTALLATION
4.1 Press the TEST BUTTON on the Control Unit, each Linked alarm will sound
and the Control Unit will perform a self-hardware test. (Due to signal timings
each alarm may trigger at the same time making it difficult to detect a faulty
alarm).
4.2 Please perform a test from each device in the system to ensure every alarm
is successfully linked.
4.3 Install the alarms then retest to ensure the devices are in range.
5. LINKING ADDITIONAL ALARMS
5.1 To add a new alarm to an existing system complete step 2, 3 & 4 for all
new alarms.
If multiple Control Units are used in a system, step 3 must be repeated for at
each Control Unit and all alarms MUST BE linked to it. Use the internal RF
button on the alarm device to access linking mode.
6. DEVICE RESET
6.1 To reset the Control Units (FHN800HIA) press and hold the “Link” Button
until all lights will flash sequentially, press the “Link” button again to
reset the device. This will blink all lights and return the device to factory
settings.
6.2 To reset an Alarm Pattress and restore factory settings, Open the alarm
device and hold down the white RF button until the light turns RED. This will
restore factory settings and unlink all devices, the light will flash green
twice per second.
7. REMOVING LINKED DEVICE
7.1 Press the “Clear” Button to enter Unlinking mode, the yellow fault light
and the red fire Light will flash.
7.2 Put the device to be removed into Linking mode, by pressing the RF button,
the green and red light will flash for a short time and the device will beep
once removed.
7.3 Exit Unlinking mode by pressing the “Reset” Button.
Fireblitz Extinguisher Ltd. Units 15-17 Manford Industrial Estate,
Manor Road. Erith, Kent DA8 2AJ
Telephone: 01322 342238 TECHNICAL HELPLINE 0800 008 6568
Text on 07885 831239 Email: customerservices@fireblitz.co.uk
For online pairing tutorial video visit: www.fireblitz.co.uk/support/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>