WILLIAMS 140382 Direct Vent Furnace Instruction Manual
- August 29, 2024
- williams
Table of Contents
- WILLIAMS 140382 Direct Vent Furnace
- Product Usage Instructions
- FAQ
- Product Information
- Warranty
- Safety Rules
- Introduction
- Installation
- Operating Your Furnace
- How to Care for Your Furnace
- Installations in the State of Massachusetts
- Blower Accessory 2302 and 2303
- Troubleshooting
- Hints And Information
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WILLIAMS 140382 Direct Vent Furnace
Product Usage Instructions
Installation in Manufactured Homes
- Williams Direct Vent Furnaces are suitable for installation in manufactured homes.
- Ensure the red certification label is present for US installations. These units are not intended for installation in trailers or recreational vehicles.
Installation Under or Over a Window
- Models 1403821, 1403822, 2203821, and 2203822 can be installed under or over a window if interior and exterior clearances are met as per installation manual P322101 figures 1 and 2.
Side Clearances to Curtains
- It is recommended to maintain a minimum of 12 inches of side clearance for curtains around the furnace to ensure proper ventilation and safety.
FAQ
- Q: Can these furnaces be installed in trailers or recreational vehicles?
- A: No, these units are designed for manufactured homes only and should not be installed in trailers or recreational vehicles.
- Q: What is the significance of the red certification label for US installations?
- A: The red certification label indicates that the furnace meets specific safety standards required for use in manufactured homes in the US.
Product Information
Model Numbers:
- 1403822; 1413822; 1433822; 1453822; 2203822; 2213822; 2233822; 2253822; 3003822; 3013822; 3033822; 3053822
FOR USE WITH NATURAL GAS ONLY
Model Numbers:
- 1403821; 1413821; 1433821; 1453821; 2203821; 2213821; 2233821; 2253821; 3003821; 3013821; 3033821; 3053821
FOR USE WITH PROPANE GAS ONLY
READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU INSTALL YOUR NEW WILLIAMS WALL FURNACE.
Information
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
- Open all windows
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone or cell phone in your building.
- Extinguish any open flame.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
- Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual.
- For assistance or additional information, consult a qualified Installer, service agency or the gas supplier.
- Do not install this furnace (Natural or L.P. Gas) in trailers or recreational vehicles.
Warranty
The manufacturer, Williams Furnace Co., warrants this wall furnace or heater to the original purchaser under the following conditions:
LIMITED ONE-YEAR WARRANTY
- Any part thereof which proves to be defective in material or workmanship within one year from date of original purchase for use will be repaired or replaced at the Manufacturer’s option, FOB, to its factory.
- No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges.
LIMITED EXTENDED WARRANTY
- In addition to the above limited one-year warranty on the complete unit, any combustion chamber which burns out or rusts under normal installation, use or service conditions during a period of nine years following expiration of the one-year warranty period will be exchanged for a like of functionally similar part.
- No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges.
LIMITATIONS
- THIS LIMITED WARRANTY IS THE ONLY WARRANTY MADE BY THE MANUFACTURER, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARE LIMITED TO THE SAME ONE YEAR TERM AS THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES SHALL THE MANUFACTURER BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES OR EXPENSES ARISING DIRECTLY OR INDIRECTLY FROM ANY DEFECT IN THE PRODUCT OR ANY COMPONENT OR FROM THE USE THEREOF. THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES.
- Some states do not allow limitation on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
- This warranty does not include any charge for labor or installation.
- This warranty does not extend to painted surfaces nor to damage or defects resulting from accident, alteration, misuses or abuse or improper installation.
- This warranty does not cover claims which do not involve defective workmanship or materials.
DUTIES OF THE CONSUMER
- The heating equipment must be installed by a qualified installer and operated in accordance with the installation and homeowner’s instructions furnished with the equipment.
- Any travel, diagnostic costs, service labor, and labor to repair the defective unit will be the responsibility of the owner.
- A bill of sale, cancelled check, payment record or permit should be kept to verify purchase date to establish the warranty period.
- Have the installer enter the requested information in the space below.
GENERAL
- The manufacturer neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with said equipment.
- Service under this warranty should be obtained by contacting your dealer. Provide the dealer with the model number, serial number, and purchase date verification.
- If, within a reasonable time after contacting your dealer, satisfactory service has not been received, contact: Customer Service Department, 250 West Laurel Street, Colton, CA 92324 for assistance.
- THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Installation Record
(Dealer or authorized representative who certifies that this appliance in accordance with manufacturer’s instructions and local codes.)
Safety Rules
WARNING: READ THESE RULES AND THE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW THESE RULES AND INSTRUCTIONS COULD CAUSE A MALFUNCTION OF THE FURNACE. THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
Installation must conform to local codes. In the absence of local codes, installation must conform with the National Fuel Gas Code, ANSI Z223.1. The appliance, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current National Electrical Code ANSI/NFPA NO. 70.
In Canada:
- Installation must conform to local codes or, in the absence of local codes, the current CAN/CGA B149 installation code.
- The appliance, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical code.
- Reference is made in this manual regarding gas type as L.P.G. Be advised that L.P.G. is not available in Canada, refer to propane/L.P. Gas.
- Use only manufacturer’s replacement parts. Use of any other parts could cause injury or death.
- DO NOT install this furnace where it could be isolated by closing doors to the heated space.
- DO NOT install this furnace in a travel trailer or recreational vehicle.
- MAINTAIN all clearances specified in section “Locating Wall Furnace and Thermostat”.
- BE SURE this furnace is for type of gas to be used. Check the rating plate by the gas valve in the lower cabinet. Do not change it to use other gases without the proper manufacturer’s Gas Conversion Kit.
- For natural gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 5″ water column. The maximum inlet gas supply pressure is 7″ water column.
- For L.P. Gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 11″ water column. The maximum inlet gas supply pressure is 13″ water column.
- Any safety screen, guard or parts removed for servicing this appliance must be replaced prior to operating the appliance to avoid property damage, bodily injury or death.
- Install the furnace vent directly to the outdoors so that harmful combustible flue gases will not collect inside the building. Follow the venting instructions for your type of installation exactly. Use only the type and size of vent pipe and fittings specified.
- BE SURE to provide for adequate combustion and ventilation air. The flow of this air to the furnace must not be blocked.
- NEVER vent flue gases into another room, a fireplace or any space inside a building. This could cause property damage, bodily injury or death.
- Never test for gas teaks with an open flame. Use a soap solution to check all gas connections. This will avoid the possibility of fire or explosion.
- ALLOW the furnace to cool before servicing. Always shut off electricity and gas to furnace when working on it. This will prevent any electrical shocks or burns.
- DUE TO HIGH TEMPERATURES, locate the furnace out of traffic and away from furniture and draperies.
- ALERT children and adults to the hazards of high surface temperatures and warn them to keep away to avoid burns or clothing ignition.
- CAREFULLY supervise young children when they are in the same room with the furnace.
- DO NOT place clothing or other flammable material on or near furnace.
- INSTALLATION and REPAIR must be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passages be kept clean. Failure to keep burner-control compartment and other parts of furnace clean can cause dangerous conditions to develop which can cause injury and even death.
- BEFORE INSTALLING: To avoid electrical shock, tum off electrical circuits that pass through the wall where you are going to install the furnace.
- BE AWARE of good safety practices by wearing personal protective equipment such as gloves and safety glasses to avoid being injured by sharp metal edges in or around furnace and while cutting or drilling holes in wood and/or sheet metal.
- CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Always shut-off electricity to furnace when working on it. This will prevent any electrical shocks or burns.
- DO NOT store or use gasoline or other flammable liquids or vapors near the furnace.
WARNING
- Do not use this furnace if any part has been under water. Immediately call a certified service technician to inspect the furnace and to replace any part of the control system and any gas control which has been under water.
- Do not install any of these furnaces (Natural or L.P. Gas) in mobile homes, trucks or recreational vehicles.
Introduction
Please read our instructions before you install and use your furnace. This
will help you obtain the full value from this furnace. It will also help you
avoid any needless service costs if the problem is found within this
instruction manual.
Always consult your local heating or plumbing inspector, building department
or electric utility company regarding regulations, codes or ordinances which
apply to the installation of a Direct-Vent Wall Furnace.
Basic Description
- Your direct-vent wall furnace is shipped ready to install against an exterior wall up to 9 inches thick. For walls greater than 9 inches, and up to 24 inches thick, use an optional Vent Extension Kit.
- The furnace may burn either Natural or L.P. Gas, depending on the model you have purchased.
- No electric power is required unless furnace is equipped with an optional blower accessory.
- Always consult your local heating or plumbing inspector, building department or gas utility company regarding regulations, codes or ordinances which apply to the installation of a direct-vent furnace.
- The sealed combustion system draws combustion air directly from outdoors into the combustion chamber and combustion gases are discharged directly outdoors through tubes on the rear of the furnace.
- The furnace cabinet is also constructed of heavy+auge steel and has a powder paint finish.
- The furnace controls are located behind an access door on the lower front of the furnace. All models are equipped with American Gas Association and Canadian Gas Association (AGA/CGA) listed gas valves and pilots.
Tools Needed
- Hand drill or properly grounded electric drill 6 ft. folding rule or tape measure Screwdrivers (Phillips Head)
- Pliers (wire cutting)
- Stud locator or small finishing nails.
- Tin snips
- 8 and 12 inch adjustable wrenches Keyhole or sabre saw
- (2) 10 inch or 12 inch pipe wrenches Gloves and safety glasses
Materials
- Pipe joint compound resistant to L.P. gases.
- Caulking compound-silicone rubber with a temperature rating of 500°F.
- DO NOT use caulking advertised as paintable or for bathtub use as most contain fillers and will not withstand high temperatures.
- Pipe and fittings to make connections to the furnace. Electrical wiring supplied as needed for optional blower. Minimum wire size is #14 gauge copper.
Helpful Installation Information
The following booklets will help you in making the installation:
- ANSI/NFPA 70, or current edition “National Electrical Code”. In Canada: CSA C22.1 Canadian Electrical Code.
- American National Standard Z223.1 or current edition “National Fuel Gas Code”.
- Obtained from: American National Standards Institute, Inc., 1430 Broadway, New York, N Y 10018. In Canada: CAN/CGA B149.
Optional Accessories
Vent Extensions: For walls greater than 9 inches thick and up to 24 inches thick, use one of the following Vent Extension Kits:
- Blower Accessories 2302, 2303 – To increase circulation of warmed air within the heated space, you may use Blower Accessory Kit 2302, for model series 22038 or Kit 2303 for model series 14038. Both are equipped with a two- speed fan and an automatic fan switch.
- Thin Wall Collar Kit 9307 – For walls less than 4-1/2 inches thick, a Thin Wall Collar Kit may be used to increase wall thickness.
- Vent-Cap Guard 9308 – This mounts to the outside of the exterior wall over the vent cap, to protect pedestrian traffic from heat.
- Vent Shield Deflector 4318 – Insulated, galvanized sheet for all direct-vent models. Thermostat P322016
- Gas Conversion Kits – Used to convert your furnace from Natural Gas to L.P. Gas and from L.P. Gas to Natural Gas.
Installation
Locating Wall Furnace
- Consider the following points before attempting to install the furnace.
All Models
- This is a direct-vent wall furnace. It must be installed on an outside wall for proper venting of flue gases. (Figure 1).
- Wall furnace must be surface mounted on an outside wall up to 24-inches thick when using an optional Vent Extension Kit.
- Check the clearances needed from the furnace and vent.(Figure 1 and 2). You must place the furnace where you will have no less than the clearances shown.
- The outside vent must be at least 18-inches away from any window or other building opening.
- The furnace will not work if anything stops free entry of fresh air into the vent, or free flow of flue gases from it. Be sure the center of the vent cap is at least 12-inches above ground level or shrubs. (Figure 1). Make sure shrubs are kept trimmed. It must also be at least 18-inches from any wall or other blockage and 30-inches below any overhang.
- Place the furnace near the center of the space to be heated for good air circulation. Do not put it behind a door or draperies. Do not put it in a closet, alcove, hallway or other confined space where the furnace could be isolated by closing doors to the heated space.
- Be sure that gas piping and electrical wiring (optional blower only) can be brought to the furnace.
- Select a location that will provide adequate accessibility clearance for servicing and proper operation.
Interior Clearances (Figure 2). 14038 Series:
- There must be at least 1-3/16 inches of space between the floor (top of floor covering) and the bottom of cabinet.
- The top of the furnace must be at least 24-inches from the ceiling or other projecting overhang.
- The side of the furnace must not be closer than 2-inches to an adjacent wall.
22038 / 30038 Series:
- There must be at least 5-1/2 inches of space between the floor (top of floor covering) and the bottom of cabinet.
- The top of the furnace must be at least 30-inches from the ceiling or other projecting overhang.
- The side of the furnace must not be closer than 2-inches to an adjacent wall.
Choose a location for the thermostat (optional) about 5-feet above floor on an inside wall. The thermostat wire supplied with your furnace is 20-feet long, which should be enough to run up through the attic so the thermostat can be a maximum of 16 feet from furnace measured in a straight line, or approximately 12-feet from the furnace if the wire is run under the floor. The thermostat should be sensing an average room temperature; avoid the following:
After selecting a location that meets the requirements, inspect the wall, floor and outside areas. Make sure there are no pipes, wiring, or anything else that would interfere with furnace, vent or thermostat installation. If required, move or pick a new location.
- To avoid electrical shock, turn off all electrical circuits that pass through the wall where you are going to install the furnace.
- This furnace must be installed using only the vent tube, air inlet tube and vent cap assembly supplied by the manufacturer.
- Before the furnace is installed, an opening must be cut through the wall for the vent cap.
Find the Studs
- Find the studs where the furnace is to be placed. Use a stud locator or small finishing nails. Drive a nail on the inside of the first stud. Drive a second nail on the outside of this stud.
- The inside edge of the next stud should be about 14-1/2 inches from the one found. Drive a finishing nail on the inside edge of this stud, then another nail on the outside edge.
- Using a level, draw vertical lines that will represent the two stud center lines.
Cut Vent Opening
- After locating the studs, use the cardboard template (Figure 4). Line up the center of the stud lines on the template with the center lines you have drawn on the wall. Use the template to draw the 9-1/4 inch diameter circle on the wall. Then mark the location of the gas supply line.
- Using a window, door or wall corner for reference, measure to find where the vent will be on the outside wall. Check to be sure of the proper clearances (Figures 1 and 2). If necessary, relocate the furnace for proper clearances.
- Drill a 1/4 inch hole in the wall at the vent opening center mark all the way through to the outside. Cut the 9-1/4 inch diameter hole through the inside wall. Using the 1/4 inch hole as center, cut a matching hole in the outside wall. It may be better to work from the outside when breaking through brick, stone or tile.
- Make sure the wall openings are aligned so vent tubes and vent will fit properly.
- In new construction, frame in 9-1/4 inch x 9-1/4 inch opening centered between the studs spaced 16 inches on centre and the center point located as noted in Figure 3.
Gas and Electrical Supply Openings
Holes must be drilled for the gas line (and electrical supply if you use an optional blower kit). Drill a 1-1/2 inch hole in the wall for the gas line where indicated on the cardboard template. (Figure 4). You will have to determine whether the gas line will enter the home through the outside wall or the floor plate. These instructions can only guide you to where the gas line will enter the furnace.
- The gas line can be run at this time or after the furnace is mounted. See “‘Gas Supply and Piping” section.
- No electrical power is required unless furnace is equipped with an optional blower kit.
- Do not connect a 115V service line to the gas valve or wall thermostat.
Install Spacer Plate (Figure 5)
- Install the mounting spacer plate with spacers entering and centered within the 9-1/4 inch vent opening in the wall.
- Level the top of the spacer plate (embossed top) and fasten it to the interior wall using the six (6) #8 roundheaded (long) screws provided.
Important
- The vent tubes are factory equipped for walls 5 to 9 inches thick only.
- For wall thicknesses up to 24 inches, follow the instructions packed with the appropriate factory Vent Extension Kits.
Furnace Mounting (Figure 5)
- Set the furnace body against the wall, legs on the floor, with the vent tubes extending through the spacer plate.
- Fasten the furnace to the wall through holes at the top and bottom of the support legs using the four (4) #3 round headed (long) screws provided.
- Push the air inlet shield on from the exterior side of the wall.
- Rotate the air inlet shield until the notches on the end of the tube are straddling the standoff tabs on the mounting spacer plate. Trim the air inlet shield flush with the exterior of the wall.
- Never crimp the vent tubes or force them to fit.
Note
- Do not trim flue extension or air inlet collar.
Install Vent Cap
- Outside, place a single strip of mastic (provided) around the back flange of the vent cap. (Figure 5). Install the vent cap by inserting it into the air inlet tube and over the vent tube.
Important
- The top of the vent cap is embossed “TOP”. Install it in the correct position to prevent water from entering the wall.
- Level the vent cap and attach it to the outside wall with four (4) #8 roundheaded (long) screws. (Figure 6).
- If the wall surface is not flat (shiplapped siding, etc.) or less than 5 inches thick, use a Thin Wall Collar Kit (9307) or, build up a flat surface with wood strips. Do not tilt or bend the cap to fit uneven surfaces. The vent cap flange must be tight against the wall to prevent rain or wind penetration. Use standard caulking compound if required (not provided).
- For brick, masonry or plaster walls, it may be necessary to use lag screws or expanding anchor bolts, which are not furnished with the furnace.
- When the vent cap is to be installed on vinyl siding, or a projection within 6 inches of any side that could block the air inlet, the entire vent should be supported away from the wall at least the distance of the projection. A 2″ x 4″ frame, with outside dimensions that match the overall dimensions of the mounting plate, is recommended. The 2″ x 4″ frame protects vinyl siding from possible damage. Seat and paint all joints.
- The wall depth plus the additional 2″ x 4″ frame depth should not exceed a total depth of 13 inches.
Thermostat Installation (Sold Separately)
Wall Mounting
- Use Williams thermostat P322016 or any millivolt thermostat.
- If an existing thermostat is being replaced and is in a satisfactory location and the wiring is in good condition, use existing wiring. If in doubt, use new wiring.
- If a new location is chosen or if this is a new installation, the thermostat wire must first be run to the location selected. All wiring must agree with local codes and ordinances. These instructions cover bringing the wire down from the attic, but it can be run from a basement or crawl space using similar methods.
- Before drilling a hole in the wall at the selected location, drive a small finishing nail through the ceiling in the comer of the wall and ceiling above the thermostat location. Pull the nail out and push a small stiff wire through the hole so it can be found in the attic. Drill a 1/2-inch hole through the ceiling wall plate.
- Probe for obstructions in the partition. Then, drill a 1/2-inch hole through the wall at the selected location for the thermostat.
- From the attic, feed the thermostat wire or a stiff wire through the wall until even with thermostat location.
- Snag the thermostat wire through the wall so that 6 inches of wire protrudes.
- Route wire to the furnace leaving enough excess wire to make the connections at the gas valve.
Cabinet Mounting
- Locate the knockout on the right side of the furnace to mount the thermostat. Remove the knockout by tapping it lightly with a screwdriver.
- Cut the thermostat wire to the required length below.
Model Number| Length
---|---
14038 Series| 31 inches
22038 Series| 45 inches
30038 Series| 47 inches - Connect the thermostat wires to terminal screws on the front of the thermostat base. See instructions packaged with thermostat.
- Feed the thermostat wires through the knockout and to the gas valve.
- Important: Keep the thermostat wire away from the combustion chamber.
- Mount the thermostat to the side of cabinet with the screws provided. Replace the thermostat cover.
- Connect the thermostat wire to the gas valve. (Figure 9).
IMPORTANT
- BEFORE REMOVING THE FACE PANEL DISCONNECT THERMOSTAT WIRES AT THE GAS VALVE.
Thermostat Mounting
- To remove the thermostat cover, grasp cover and squeeze both sides firmly, then lift to remove cover. Carefully remove and discard the packing tab protecting the switch contacts.
- Connect thermostat wires to the terminal screws on the front of thermostat base.
- Push any excess wire back through hole in the wall and plug the hole with insulation to prevent drafts from affecting thermostat operation.
- Being sure to level thermostat for the best appearance. Fasten the thermostat base to the wall through the mounting holes with the screws provided.
- Replace the thermostat cover.
Note: Refer to the installation instructions packed in the thermostat carton if you have any doubt about the above procedures.
Cabinet Installation
14038 Series:
- Set the cabinet over the furnace body, dropping the rear top flange between the support legs and wall.
- Open the cabinet door and attach the cabinet to the inner casing with two (2) sheet metal screws. (Figure 10).
22038 / 30038 Series:
Set the cabinet over the furnace body, dropping the rear top flange into the slot in top of the spacer plate and into the slots between the support legs and wall. When correctly positioned side-to-side, a dimple on the rear top flange will slide against the inside of each support leg. Attach two (2) tension springs through the bottom flange of the combustion chamber and the bottom of the cabinet. Fasten the trim strip to the bottom of the support legs using two (2) sheet metal (short) screws. (Figure 11).
Gas Supply and Piping
- The gas control valve is shipped with a sealed cover over the gas inlet tapping. Do not remove seal until you are ready to connect piping.
WARNING: Danger of property damage, bodily injury or death. Make sure the furnace is equipped to operate on the type of gas available.Models designated as natural gas are to be used with natural gas only. Furnaces designated for use with liquefied petroleum gas (L.P.G.) have orifices sized for commercially pure propane gas. They cannot be used with butane or a mixture of butane and propane.
Gas Supply
- Minimum gas supply pressure for natural gas to the furnace control valve is 5 inches water column and must not be more than 7 inches water column.
- Minimum gas supply pressure for L.P. gas to the furnace control valve must be at least 11 inches water column and must not exceed 13 inches water column.
Gas pressures and pressures to the burners must not exceed the rated input and pressure shown on the rating plate. For natural gas, the manifold pressure should be 4 inches water column. The manifold pressure should be 10 inches water column for L.P. gas. An orifice change may be required to suit the gas supplied.
Orifice Sizes
The efficiency rating of these appliances is a product thermal efficiency rating determined under continuous operating conditions and determined independently of any installed system. For elevations above 2,000 feet reduce ratings 4% for each 1,000 feet above sea level. The correct orifice sizes for the different input ratings when using natural or L.P. gas are:
CAPACITY AND ORIFICE SIZING
MODEL NUMBER
|
GAS TYPE
|
INPUT RATING
Btu/hr.
|
HEATING CAPACITY RATING
Btu/hr.
| Main Burner Orifice
DRILL
|
DEC
|
QTY
14038 Series| Nat.| 14,000| 9,800| #50| .0700| 1
14038 Series| L.P.| 14,000| 9,800| #56| .0460| 1
22038 Series| Nat.| 22,000| 16,210| #44| .0860| 1
22038 Series| L.P.| 22,000| 16,595| N/A| .0560| 1
30038 Series| Nat.| 30,000| 21,000| #39| .0990| 1
30038 Series| L.P.| 30,000| 21,000| N/A| .0640| 1
- Btu/hr. = British Thermal Units per hour.
CONVERSION KITS
Description| Models
Natural Gas to L.P. Gas for 14038 Series| 8939
Natural Gas to L.P. Gas for 22038 Series| 8940
Natural Gas to L.P. Gas for 30038 Series| 8941
L.P. Gas to Natural Gas for 14038 Series| 8942
L.P. Gas to Natural Gas for 22038 Series| 8943
L.P. Gas to Natural Gas for 30038 Series| 8944
Gas Piping
The gas supply line must be of an adequate size to handle the Btu/hr.
requirements and length of the run for the unit being installed.
Determine the minimum pipe size from Figure 14, basing the length of the run
from the gas meter or source to the unit.
All piping must comply with local codes and ordinances or with the National
Fuel Gas Code (ANSI Z223.1 NFPA No. 54), whichever applies. (In Canada:
CAN/C.G.A B149). Refer to
Figure 12 for the general layout of the unit. It shows the basic fittings
needed.
- Use new, properly reamed pipe free from chips such as steel or black iron pipe and fittings that are approved by local codes. Metal chips and debris can damage the gas valve.
- Do not thread the pipe too far. Distortion or malfunction may result from excess pipe within the control valve. Apply a moderate amount of good quality dope to the pipe threads only. Leave the two end threads bare. (Figure 13). On L.P. gas installations, use a compound resistant to action of liquefied petroleum gases.
- Use ground joint unions.
- Install a drip leg (sediment trap) to trap dirt and moisture before it can enter the gas valve. The nipple must be a minimum of 3-inches long.
- Install a manual shutoff valve.
- Provide a 1/8″ NPT test gauge connection immediately before the gas supply connection to the furnace.
Gas Connection
- If installation is for L.P. gas, use a two-stage regulator and make all connections from the storage the tank to furnace.
- Use two pipe wrenches when making the connection to the valve to prevent turning and/or damage to the gas valve.
- The connection between the shutoff valve and the burner control assembly can be made with an A.G.A / C.G.A. design certified flexible connector if allowed by local codes.
- Tighten all joints securely.
Checking the Gas Piping
Test all piping for leaks. When checking gas piping to the furnace with gas pressure at less than 1/2 PSI, shut off manual gas valve to the furnace. If the gas piping is to be checked with the pressure at or above 1/2 PSI, the furnace and manual shutoff valve must be disconnected during testing. Apply a soap solution (or a liquid detergent) to each joint. Bubbles forming indicate a leak. Correct even the slightest leak at once.
WARNING: Danger of property damage, bodily injury or death. Never use a match or open flame to test for leaks. Never exceed specified pressures for testing. Higher pressures may damage the gas valve and cause over firing which may result in combustion chamber failure. Liquefied petroleum gas (L.P.G.) is heavier than air and it will settle in any low area, including open depressions and it will remain there unless area is ventilated. Never attempt start-up of the unit before thoroughly ventilating the area and smelling near the floor for gas odor.
FIGURE 14
Gas Pipe Sizes
Natural Gas
Pipe Capacity – Btu/hr. (includes Fittings)
Pipe Size
Length of Pipe – Ft| 1/2”| 3/4”| 1”
20| 92,000| 190,000| 350,000
40| 63,000| 130,000| 245,000
60| 50,000| 105,000| 195,000
L. P Gas
Pipe Capacity – Btu/hr. (includes Fittings)
Pipe Size
Length of Pipe – Ft| 1/2”| 3/4”| 1”
20| 189,000| 393,000| 732,000
40| 129,000| 267,000| 504,000
60| 103,000| 217,000| 409,000
When an existing category I heater is removed or replaced, the original venting system may no longer be sized to properly vent the attached appliances.
WARNING: CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monoxide poisoning or death.
The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation:
- Seal any unused openings in the venting system.
- Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code, CSA 8149.1 and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition.
- As far as practical, close all building doors and windows and all doors between the space in which the appliance(s) connected to the venting system are located and other spaces of the building.
- Close fireplace dampers.
- Turn on clothes dryers and any appliance not connected to the venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they are operating at maximum speed. Do not operate a summer exhaust fan.
- Follow the lighting instructions. Place the appliance being inspected into operation. Adjust the thermostat so appliance is operating continuously.
- Test for spillage from draft hood equipped appliances at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle.
- If improper venting is observed during any of the above tests, the venting system must be corrected in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or Natural Gas and Propane Installation Code, CSA 8149.1.
- After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gashed burning appliance to their previous conditions of use.
Operating Your Furnace
The furnace operates in the following sequence:
- The thermostat turns on the main burner.
- Heat builds up in the furnace and starts the fan (if equipped). The heated air comes out the panel louvers.
- When the thermostat setting is reached, it shuts off the main burner.
- The fan runs until the heat is removed from the furnace, then it turns off.
Your furnace is equipped with a built-in pressure regulator. L.P. gas models also have a regulator at the supply tank. If you have a question regarding the amount of fuel consumed, call your local gas utility or gas supplier.
WARNING: DO NOT TAMPER WITH THE REGULATOR OR BURNER ORIFICES, AS PROBLEMS RESULTING FROM THERE MAY CAUSE PRODUCT FAILURE NOT COVERED BY WARRANTY.
Input and output ratings shown on the rating plate, located in burner compartment, must not be exceeded.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
WARNING
- Do not store or use gasoline or other flammable liquids or vapors near the furnace.
- Danger of bodily injury or death. Do not operate the furnace with a broken or missing pilot observation door.
Lighting the Pilot
FOR YOUR SAFETY, READ BEFORE LIGHTING
This furnace is equipped with a manually operated piezo sparkignition device to ignite the pilot gas. Follow the steps below and use the manual spark igniter to light the pilot in place of a match. Press spark igniter button repeatedly and vigorously. If the spark igniter fails to provide spark to light the pilot, loosen the wing nut holding the pilot cover. This opens to the combustion chamber. The pilot may be ignited with a match.
- Follow the instructions below and use a match to light the pilot as instructed.
- After lighting the pilot, carefully replace the pilot observation door and tighten wing nut down.
On new installations, the gas lines will be filled with air and it may take several tries to establish the pilot flame. Check the manual shutoff valve in the gas line. It must be in the open position (handle parallel to the gas line) before you can light your furnace. Your furnace is equipped with a 100% safety pilot, which will shut off the gas valve in case the pilot is not burning or functioning properly. Make sure the pilot is adjusted properly and that the generator connection at the control valve is tight. If furnace will not stay lit, call your local gas utility company.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.
- BEFORE LIGHTING smell around the appliance area for gas. Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor.
- Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
- Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch. Do not use any telephone or cell phone in your building.
- Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier call the fire department.
IMPORTANT
- KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
Operating Instructions
- STOP! Read the safety information above.
- Set the thermostat to lowest setting.
- If applicable, tum off all electric power to the appliance.
- Open the control access panel.
- Push in the gas control knob slightly and turn it clockwise to “OFF”.
- NOTE: The knob cannot be turned from “PILOT’ to “OFF” unless the knob is pushed in slightly. Do not use force.
- Wait five (5) minutes to clear out any gas, then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information on previous page. If you do not smell gas, go to the next step.
- Loosen wing nut and open the pilot observation door.
- To find the pilot, follow the metal tube from gas control valve. The pilot is mounted on the side of the burner.
- Turn the knob on gas control valve counter clockwise to “PILOT”.
- Push in the control knob all the way and hold it in. Immediately light the pilot. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release the knob and it will pop back up. The pilot should remain lit. If it goes out, repeat Steps 5 through 10. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF’ and call your service technician or gas supplier.
- Close the pilot observation door, tighten the wing nut (if equipped).
- Turn the gas control knob counter clockwise to “ON”.
- Close the control access panel.
- Turn on all electric power to the appliance (if applicable).
- Set thermostat to the desired setting.
To Turn Off Gas To Appliance
- Set the thermostat to its lowest setting.
- If servicing is to be performed, turn off all electric power to the appliance.
- Open the control access panel.
- Push in the gas control knob slightly and turn it clockwise to the “OFF” position. Do not use force.
- Close the control access panel.
WARNING
- Due to high surface temperatures, keep children, clothing, furniture or any combustible material away from the furnace.
- Danger of ignition flash and eye injury or blindness. Protect your eyes. Never attempt to light the pilot with the gas control valve knob in the “ON” position. Flashback could occur.
Start-Up Procedure
Start the furnace using the procedures in the section “Operating Your Furnace”.
WARNING: Danger of bodily injury or death. Liquid petroleum gas (L.P.G.) is heavier than air and it will settle in any low area, including open depressions, and it will remain there unless the area is ventilated. Never attempt to start-up the unit before thoroughly ventilating the area.
Check the furnace operation as outlined in the following instructions. If any sparking, odor or unusual noises are encountered, shut off electrical power immediately. Recheck for wiring errors or obstructions in or near the optional blower motor.
Notice
- During the initial firing of this unit, some smoke and odor may occur. We recommend ventilating the area during this initial “break-in period”.
Check Gas Input and Pressures
For furnaces located at altitudes between sea level and 2,000 feet, the measured input must not be greater than the input shown on the rating plate of the furnace. For elevations above 2,000 feet, the measured input must not exceed the input on the rating plate reduced by 4% for each 1,000 feet that the furnace is above sea level.
The gas supply pressure and the manifold pressure with the burners operating must also be as specified on the rating plate.
Type of Gas | Manifold Pressure, In W.C. |
---|---|
Natural | 4 |
L.P. | 10 |
The rated input will be obtained on 2,500 Btu of propane at 10 inches manifold pressure with factory-sized orifices. If L.P. Gas having a different value is supplied, orifices must be changed by a qualified installer before the furnace is operated.
Check the Manifold Gas Pressure
A tapped opening is provided in the gas valve to facilitate measuring the manifold gas pressure. A “U tube” manometer having a scale range from 0 to 12-inches water column should be used for this measurement. The manifold pressure must be measured with the burner and pilot operating. Any major changes in the flow must be made by changing the size of the burner orifice. Check with your local gas company for the proper orifice size.
Check the Gas Input (Natural Gas Only)
Under firing could cause inadequate heat, excessive condensation or ignition problems. Over firing could cause shooting flame impingement or overheating of the combustion chamber. Before starting the natural gas input check, obtain the heating valve of the gas (BTU per cubic foot) at standard conditions from your local supplier. This factor is used in the “Check the Gas lnput” section and procedure.
To measure the input using the gas meter, proceed as follows:
- Turn off the gas supply to all other appliances except the furnace.
- With the furnace operating, time the smallest dial on the meter for one complete revolution. If this is a 2 cubic foot dial, divide the seconds by 2; if it is a 1 cubic foot dial, use the time in seconds as is. (3,600 = Sec. Per Hr.) This gives the seconds per cubic foot of gas being delivered to the furnace.
- Assuming natural gas with a heating valve of 1,000 Btu per cubic foot and 34 seconds per cubic foot as determined by step 2 above, then:
- Input: 1,000 x 3,600÷34 = 106,000 Btu/hr.
- This measured input must not be greater than the input indicated on the rating plate of the furnace.
- Relight all other appliances turned off in step 1 above. Be sure all pilot burners are operating.
WARNING: Natural gas heating valve (Btu per cubic foot) can vary significantly; therefore, it is the installer’s responsibility to see that Btu input to the furnace is adjusted properly. Failure to do so could cause combustion chamber failure, asphyxiation, fire or explosion, resulting in damage, bodily injury or death. Refer to the Natural Fuel Gas Code (NFPA-54) to be sure the furnace is burning fuel at the proper rate.
Check Pilot Burner
- The pilot flame should surround the generator tip 3/8-inch to 1/2-inch.
- Pilot gas may need adjustment depending on the inlet pressure. Increase or decrease the pilot flame to obtain proper setting.
Burner Flame Characteristics
Start the furnace and let it operate at least 10 minutes. Open the access door to view the burner flame. Limit your movements near the furnace a few more minutes before making your final observation. The flame may look yellow due to dust particles in the room air. The flame should change to a nice blue color with firm inner and secondary cones. An occasional flash of orange might be seen as dust particles burn in the flame. This is normal. No burner adjustment is provided, or is necessary. (Figure 16).
Normal Appearance
Natural Gas:
- Inner cone- blue color – 1/2 to 3/4-inch above ports.
- Secondary inner cone – light blue – 1 to 2-inches above ports.
- Total flame – from blue to nearly invisible – approximately 6- inches above ports.
L.P Gas:
- Inner cone – blue color – 1/2 to 3/4-inch above ports.
- Secondary inner cone – light blue – 1 to 2-inches above ports.
- Total flame – from blue to nearly invisible – approximately 6- inches above ports.
How to Care for Your Furnace
Abnormal Appearance
- Lazy Flame:
- Long soft yellow cones moving around in the combustion chamber lifting from ports (insufficient air).
- Extremely Fast Flame:
- Will not hold to ports – entire cone sections blow off from noisy ports (too much pressure).
Annual Upkeep Needed
- It is recommended that a qualified service technician perform these checks at the beginning of each heating season:
Burner Cleaning
Keep clean at all times. Clean all foreign materials from the top of burner. For access to the burner:
- Shut off the gas supply to furnace.
- Remove the cabinet.
- Disconnect the gas line inside cabinet at the ground joint union fitting.
- Remove the six (6) #10-24 screws securing the control door assembly to the combustion chamber.
- Carefully remove the control door and burner assembly from the combustion chamber. Be careful not to damage the control door gasket.
- Clean all foreign materials from the top of the burner.
- After cleaning, replace the control door and the burner assembly by reversing the above procedure. The control door gasket should be replaced if its condition is in doubt.
Cleaning Burner Compartment
Because cold air is attracted to the flame during furnace operation, a build up of lint from carpeting, bedding, dust, etc. in the burner area will occur. It is necessary to clean this arearegularly. Use a vacuum cleaner with a narrow attachment to reach small areas. Be careful in and around the pilot. A change in its adjustment could be made if moved during cleaning. A properly adjusted burner with nearly all gasses will produce a flame which has a clear blue cone having a bluish-red or bluish-violet outer mantle.
Cleaning Blower (If Equipped)
Turn off electric power supply at the disconnect switch, fuse box or service panel before servicing. For maximum motor life of the optional blower, inspect the motor yearly and clean any lint or dust from fan blades, fan motor and ventilating holes. Oil yearly with two drops of SAE 20 high temperature oil.
Vent System
- Check the vent cap and tubes to be sure there are no blocked inlet air or flue openings. The flow of combustion and ventilation air must not be obstructed. Clean or replace before using the furnace. On new installations, the gas lines will be filled with air and may take several minutes to establish a pilot flame.
Furnace Area
- For better circulation and more effective heating, do not place obstructive furniture closer than four feet to the front of the cabinet or two feet to either side of the cabinet.
- The furnace area must be kept clear and free from combustible material, gasoline and other flammable vapor and liquids.
Cabinet Finish
- Clean the cabinet with a damp cloth. Never use abrasive cleaners. Cabinets are finished in heat-resistant powder paint.
- DO NOT refinish.
Pilot Burner
Light the pilot using instructions in “Lighting the Pilot”. Leave the thermostat at its lowest setting. The pilot flame should surround the generator tip 1/4″ to 5/8″. If flame needs adjusting, do so as follows:
- Insert a small screwdriver into the pilot adjusting screw. Adjust flame as needed. Turn the screw counterclockwise to increase the flame, clockwise to decrease the flame.
- Turn the thermostat to the highest setting. The main burner should light quickly and smoothly. Turn the thermostat to its lowest setting. The main burner should go out. The pilot should remain lit.
WARNING: Danger of bodily injury or death. If equipped with accessory blower, turn off the electric power supply at the disconnect switch, fuse box or service panel before removing any access doors or service panels from unit.
Installations in the State of Massachusetts
All installations in the State of Massachusetts must use the following requirements when installing, maintaining or operating direct-vent propane or natural gas-fired space furnaces. For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent terminal and the air intake is installed below four feet above grade the following requirements must be satisfied:
- If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 (2005 Edition).
- A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall:
-
- Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the appliance and the carbon monoxide detector.
* Have battery back-up power;
* Meet ANSI/UL 2034 Standards and comply with NFPA 720 (2005 Edition); and
* Have been approved and listed by a Nationally Recognized Testing Laboratory as recognized under 527 CMR.
2. **A carbon monoxide detector shall:**
* Be located in the room that houses the appliance or equipment;
* Be either hardwired or battery powered or both; and
* Shall comply with NFPA 720 (2005 Edition).
- A product approved vent terminal must be used, and if applicable, a product approved air intake must be used. Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall remain with the appliance or equipment at the completion of the installation.
- A metal or plastic identification plate shall be mounted at the exterior of the building, four feet directly above the location of vent terminal. The plate shall be of sufficient size to be easily read from a distance of eight feet away, and read “Gas Vent Directly Below”.
Blower Accessory 2302 and 2303
This accessory can be operated using the factory equipped three-prong (grounding) plug and cord or may be field wired. See field wiring installation instructions below. When using the plug and cord, for your protection against shock hazard, it must be plugged directly into a properly grounded three- prong receptacle. DO NOT REMOVE THE PRONG. All electrical work must conform to your local codes and ordinances, or in their absence, with National Electrical Code ANSI/NFPA 70. In Canada, Canadian Electrical Code C22.1. It must also be electrically grounded. If you are not familiar with wiring codes in general, have a competent electrician do the job.
WARNING: Danger of property damage bodily injury or death. Unplug the service cord from the electrical outlet before removing or working on this blower kit.
Mounting
Model 2302
- Remove the knock-out plates “A” and “B” from right side of the furnace. (Figure 1 page 20).
- Remove the junction box cover and place the blower and junction box in position as shown on Figure 1 page 20.
- Attach the blower and the junction box to the inner casing using the pre-punched holes with screws “C” and “D” provided with this kit. See Figure 1 on page 20 for proper mounting hole to use with your furnace model (see rating plate for furnace model number). Reattach the junction box cover.
- After the blower and junction box are installed, rotate bushing “H” if needed to prevent the motor wire from binding against the blower casing.
- Plug in the factory supplied three-prong (grounding) plug and cord or see field wiring instructions below.
Model 2303
- Set the blower on top of the furnace with the rear flange of the blower cabinet behind the furnace cabinet. This will place the back of the blower cabinet against the wall surface. (See Figure 2 page 20).
- Plug in the service cord.
Field Wiring
Model 2302
- Remove the junction box cover and disconnect the factory installed three-prong (grounding) plug and cord.
- Install a 115V line in accordance with local codes, connecting as shown in the wiring diagram. (Figure 1 page 20).
- Reattach the junction box cover.
Important
- Oil yearly with SAE 20 high temp oil.
Blower Operation
Model 2302
The automatic fan switch turns on the blower after the furnacehas been operating a few minutes and turns off the blower after the furnace shuts off. The blower will not operate unless the fan switch (pull chain) is pulled to the “ON” position, either “HIGH” or “LOW”. To check the fan switch (pull chain) position, tum the automatic fan switch dial to 70, then pull the chain on the fan switch to obtain the high, low or off position. Set the automatic fan switch dial to 110 and readjust it higher or lower as necessary to obtain blower operation within 4 to 5 minutes after the furnace burner is in operation.
Model 2303
You must select “ON” for continuous blower operation or “AUTO” for automatic blower operation. If blower is set on “AUTO” when the furnace heats up, the heat sensor switch is activated and the blower will turn off. The blower will not operate if the fan switch is set in the “OFF’ (center) position.
KIT No. 2302
KIT NO. 2303
Replacement Parts List
Model 2302
Ref. Number | Part Number | Description |
---|---|---|
1 | 6A24 | Switch Box Bracket |
2 | 6B33 | Switch Box |
3 | P321017 | Fan Switch (Pull Chain) |
4 | P332490 | Automatic Fan Switch |
5 | 6A23 | Switch Box Cover |
6 | P130600 | Motor |
7 | 6A93 | Motor Support |
8 | P128400 | Vibration Isolator (2 Required) |
9 | P130700 | Blower Wheel |
10 | 6B64 | Blower Frame |
11 | P323335 | Plug and Cord |
Model 2303
Ref. Number | Part Number | Description |
---|---|---|
1 | 8A128 | Back Plate |
2 | P101000 | Wire |
3 | 8B94 | Fan Blower Assembly |
4 | 8B93 | Blower Casing Assembly |
5 | 8B90 | Louver Assembly |
6 | P323095 | Heat Sensor Switch |
7 | P500158 | Strain Relief |
8 | P323080 | Fan Switch |
9 | P323335 | Plug and Cord |
Note: Screws and bolts are standard hardware items and may be purchased locally.
Ref. Number
|
Description
| 1403821
1413821
1433821
1453821
| 1403822
1413822
1433822
1453822
---|---|---|---
1| Face Panel| 4309| 4309
2| Combustion Chamber Shield| 8A72| 8A72
3| Combustion Chamber| 6303| 6303
4| Flue Tube Gasket (2 Required)| P147001/2| P147001/2
5| Inner Casing| 8B62| 8B62
6| Air Inlet Gasket| P147000| P147000
7| Air Inlet Shield (Standard Maximum 9″ Thick Wall)| 6C54-1| 6C54-1
8| Vent Cap| 9306| 9306
9| Air Inlet Collar (Standard Maximum 9″ Thick Wall)| 6C60| 6C60
10| Flue Extension (Standard Maximum 9′ Thick Wall)| 6A193| 6A193
11| Mounting Spacer Plate| 8B64| 8B64
12| Air Inlet Gasket| P121800| P121800
Note: Screws and bolts are standard hardware items and may be purchased locally.
Ref. Number
|
Description
| 2203821
2213821
2233821
2253821
| 2203822
2213822
2233822
2253822
| 3003821
3013821
3033821
3053821
| 3003822
3013822
3033822
3053821
---|---|---|---|---|---
1| Face Panel| 4313| 4313| 4313| 4313
2| Combustion Chamber Shield| 6B149| 6B149| 6B149| 6B149
3| Flue Tube Gasket (2 Required)| P147001| P147001| P147001| P147001
4| Flue Extension (Standard Maximum 9″ Thick Wall)| 8A51| 8A51| 6A190| 6A190
5| Air Inlet Gasket| P147000| P147000| P147000| P147000
6| Air Inlet Collar (Standard Maximum 9″ Thick Wall)| 6C60| 6C60| 6C51| 6C51
7| Mounting Spacer Plate| 6C66| 6C66| 6C66| 6C66
8| Air Inlet Shield (Standard Maximum 9″ Thick Wall)| 6C54-1| 6C54-1| 6C54-1|
6C54-1
9| Vent Cap| 9306| 9306| 9306| 9306
10| Inner Casing| 6D20| 6D20| 6D20| 6D20
11| Air Inlet Gasket (2 Required)| P121800| P121800| P121800| P121800
12| Combustion Chamber| 6304| 6304| 6304| 6304
13| Leg Cover Plate| 6B25| 6B25| 6B25| 6B25
14| Bottom Heat Shield| –| –| 6A240| 6A240
Note: Screws and bolts are standard hardware items and may be purchased locally.
Ref. Number
|
Description
| 1403821
1413821
1433821
1453821
| 1403822
1413822
1433822
1453822
---|---|---|---
1| Burner| P168400| P168400
2| Control Door with P500677 Gasket| 8A103| 8A103
3| Gas Valve| P295201A| P295200A
4| Manifold with P147200 Gasket| P323659| P323659
5| Burner Orifice (Sea Level)| P090556| P090550
6| Manual Spark Igniter| P285500| P285500
7| Pilot (P142700 gasket not included)| P322399| P323700
8| Thermostat| P322016| P322016
9| Observation Door with P100100 Gasket| 12B40| 12B40
10| Electrode| P322400| P322400
Note: Screws and bolts are standard hardware items and may be purchased locally.
Ref. Number
|
Description
| 2203821
2213821
2233821
2253821
| 2203822
2213822
2233822
2253822
| 3003821
3013821
3033821
3053821
| 3003822
3013822
3033822
3053822
---|---|---|---|---|---
1| Burner| P168404| P168404| P168404| P168404
2| Control Door with P500677 Gasket| 8A135| 8A135| 8A135| 8A135
3| Gas Valve| P295201A| P295200A| P295201A| P295200A
4| Manifold with P147200 Gasket| P323655| P323655| P323655| P323655
5| Burner Orifice (Sea Level)| P332628| P090544| P332621| P090539
6| Manual Spark Igniter| P285500| P285500| P285500| P285500
7| Pilot (P142700 gasket not included)| P322399| P322398| P322399| P322398
8| Thermostat| P322016| P322016| P322016| P322016
9| Observation Door with P100100 Gasket| 12B40| 12B40| 12B40| 12B40
10| Electrode| P322400| P322400| P322400| P322400
Troubleshooting
SYMPTOM | POSSIBLE CAUSE | CORRECTIVE ACTION |
---|---|---|
1. Pilot will not stay lit after carefully following lighting instructions. | ||
A. Generator producing insufficient millivolts. | Check the pilot flame. It |
must impinge on the generator. Be sure the generator is fully inserted in the bracket. Make sure the pilot
lighting door is tightly closed.
B. Generator defective.| Check generator with millivolt meter. Take reading at
generator terminals of valve with pilot burning and thermostat contacts
closed. The reading should be 140 millivolts or more.
C. Loose or dirty generator connections at gas valve.| Clean and/or tighten
connections at valve.
D. Grounded thermostat lead wire.| Remove thermostat lead wires from valve
terminals. If the pilot now stays lit, trace the thermostat wiring circuit for
a ground. May be grounded to the furnace, gas supply, nails or staples.
E. Defective gas valve.| Replace the gas valve after the above is verified.
2. Pilot burning – no gas to the main burner.| A. Valve not turned to “ON”
position after lighting the pilot.| Turn the gas valve knob to the “ON”
position.
B. Thermostat not turned to a position calling for heat.| Set the thermostat
to a position calling for heat.
C. Plugged burner orifice.| Check – clean or replace.
D. Improperly wired or broken thermostat wires.
Defective thermostat.
| Check the connections at the valve terminals. Jumper across the thermostat
terminals on the valve. If the valve operates, check the thermostat wires.
E. Pilot generator may not be generating sufficient milli volts to open
valve.| See 1A and 1C above.
F. Defective valve.| Replace the gas valve after above is verified.
3. Burner comes “ON” but goes “OFF” after operating for no apparent reason.|
A. Tubes not properly installed.| Check the vent tube and the air inlet tube.
Follow the installation instructions. Be sure the joints are tight and both
tubes are in place. Use only the tubes furnished. Do not extend
the tubes beyond original length.
B. Furnace may be overrated.| Check for high pressure at the valve. See rating
plate for specified min./max. supply pressure. Check the burner orifice.
4. Furnace operates, but turns “OFF” before room temperature is attained.| A.
Thermostat location.| Check the thermostat location. It should not be in the
path of warm air discharge from the furnace, near a lamp or above a T.V. or
stereo
set.
B. Defective thermostat.| Check the thermostat calibration or replace.
5. Furnace not producing sufficient heat.| A. Furnace may be too small for
space being heated.| Check heat calculations.
B. Furnace not burning at full rate.| Check for low gas pressure. Check the
burner orifice.
6. Furnace operates, but will not shut “OFF” when room temperature is
attained.| A. Thermostat wiring defective.| Thermostat lead wires may be
shorted together, by a nail or staple. Check by removing thermostat leads from
the valve terminals.
B. Thermostat location.| Check the thermostat location. If on an outside wall
or there is a hole in the wall behind the thermostat causing cold air to
contact the
| | thermostat. Relocate the thermostat.
---|---|---
C. Defective thermostat.| Check the thermostat calibration or replace.
D. Dirt under the valve seat or valve stuck open.| Replace the valve.
7. Pilot outage problem.| A. Pilot flame may be low or blowing (High),
causing the safety to drop out.| Adjust pilot flame. Check vent tube and air
inlet tube. Be sure pilot lighting door is closed. Pilot orifice or aerating
hole may be plugged (check for spiders, webs or other material).
B. Broken or no gaskets on control or pilot observation doors.| Clean and
replace.
8. Abnormal operation.| A. Delayed ignition – pilot flame may be too low.|
Adjust pilot flame.
B. Expansion noise ticking.| Casing may be distorted by being fastened to an
uneven wall. Vent tube and air inlet tube may be in a bind with a vent cap
assembly. Be sure the hole through the wall is correct and parts fit without
binding.
9. Noisy Blower.| A. Housing rattling.| Tighten blower screws.
B. Blower dirty.| Clean blower wheel.
C. Blower wheel bent.| Straighten or replace.
10. Blower does not run.| A. Fan switch not set.| Select fan speed.
B. Check bearings.| Add oil as outlined in blower instructions.
Service Record
Date | Maintenance Performed | Components Required |
---|---|---|
Hints And Information
Service Hints
If your furnace fails to work correctly, you may avoid the inconvenience and cost of a service call by checking the troubleshooting section.
For Your Safety:
Always disconnect furnace circuit switch before opening furnace for inspection or service.
WARNING
- If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
- Open all windows
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone or cell phone in your building.
- Extinguish any open flame.
- Immediately call your gas supplier from a neighbor’s phone. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
How to Order Repair Parts
When ordering repair parts, always give the following Information:
- Model number
- Mfg. Date code
- Part number
- Part description
All parts listed herein may be ordered from your equipment supplier. The model number of your Williams wall furnace will be found on the name plate.