TRIPLETT IRTC800 Thermal Imaging Camera User Manual
- August 23, 2024
- TRIPLETT
Table of Contents
TRIPLETT IRTC800 Thermal Imaging Camera
Performance indicators
Swatches
| Iron red, rainbow, black heat, white heat, red heat, lava, and high contrast
rainbow
---|---
Infrared spectral bandwidth| 8~14μm
Field of view| HFOV 56°
Focusing mode| Free Focus
Digital zoom| 2x,4x
Temperature Sweep| 5 points,3 rectangles,3 circles, and1 line (add up to 6)
Vitta tool
| Automatic isothermal, proportional isothermal, downward isothermal, upward isothermal, interval isothermal,
and manual isothermal
Temperature display| Center point temperature, and high/low temperature
tracking
Temperature measurement unit| ℃(default)、℉、K
High and low temperature alarm| Yes (LED lighting alarm, and LCD animation
alarm)
Image mode| Thermal imaging, visible light, fusion, and picture in picture
Image capture mode| Take pictures, and automatically take pictures
Image save format| JPG
Image browse| Temperature analysis, changingswatches, and remarks
QR code scanning| Yes
USB communication| Type-c USB (Charging, real-time image and USB disk storage)
WIFI| Yes
PC projection screen| Yes
PC analysis software| Yes (live image, photo download and analysis)
Mobile phone APP| Yes (Photo download and analysis)
LED lighting| Yes
Language| English/French/German/Spanish/Russian
Authentication| CE FCC UKCA ROHS
Operation temperature| 0℃~ 50℃ (32℉~ 122℉)
Storage temperature| -10℃~ 60℃ (14℉~ 140℉)
Operation humidity| 10%~95%RH (Non – Condensing)
Battery| 5200mAh(Detachable battery pack)
Auto Power -Off| Yes
---|---
Service duration| More than 3h
Charging period| Less than 4h
Charging voltage/current
| 5V/ 1.5a 9V/1A 12V/1A
(supported only with standard USB charging below QC2.0)
Image saving| The microSD card supporting 32 GB for maximum
IP level| IP54 (IEC 60529:1989+A1:1999+A2:2013 )
Drop height| 2m
Structure
No. | Description | No. | Description |
---|---|---|---|
1 | The USB Type – C interface | 11 | Photo browsing button |
2 | Upper casing | 12 | Back key |
3 | Lower casing | 13 | Right key |
4 | SD card slot | 14 | SET key |
5 | Interface protection cover | 15 | Down key |
6 | LCD display | 16 | Bracket fixed screw hole |
7 | Start key | 17 | Infrared thermal image window |
8 | Lighting key | 18 | Lamp |
9 | Left key | 19 | Visible light camera window |
10 | Up key | 20 | Photo trigger key |
Display instructions
Display resolution: 640×480
No. | Description | No. | Description |
---|---|---|---|
1 | Marking tool | 8 | Automatic tracking of the minimum point |
2 | Image mode | 9 | Color temperature bar |
3 | Swatches switch | 10 | Upper limit of swatchesscale |
4 | Temperature measuring tool | 11 | Electric quantity |
5 | Vitta tool | 12 | Temperature of the measurement central point |
6 | System setup | 13 | Automatic tracking of the maximum point |
7 | Lower limit of swatchesscale | 14 | Temperature measurement central point |
Power on-off
Long press the “Power button” for 5 seconds to start up the thermal imaging
device (if start up the device just now, the device is not being used for a
long time or after the measurement environment changes, it will take up to 30
minutes for starting up the device to measure the temperature). Long press the
“Power button” for 5 seconds to turn off the thermal imaging device. When the
thermal imaging device is in low power mode, the reminder of low power will
pop up. At this time, the thermal imaging device needs to be turned off to
charge. When the thermal imaging device is in low power mode all the time, the
thermal imaging device will automatically be shut down.
Instruction of configuration menu
Configuration options for the main menu
The main page of the thermal imaging device
- Press the “SET key” on the home page to display the main menu
- Press the “Left/right key” to select sub-menu
- Press the “SET key” to enter the corresponding sub-menu
- Press the “Left/right key” to select the sub-menu Settings
- Press the “SET key” to select Settings
- Press “the Back key” to return to the previous level and save the Settings
- Press the “Back key” again to return to the home page of the thermal imaging
Main menu
Sub-menu
Marking tool
If you need to use the center point/high/low-temperature tracking/temperature
display function, press the “SET key” to pop up the main menu options, select
“Marking tool” by using the left/right key, and then press “SET key” to enter
the marking tool sub-menu options and make selection by using left/right key.
(For example: Press the “SET key” to select “Center point”. When cross
collimation appears, it means that the center point cursor is opened. Press
the “SET key” again, and the cross collimation disappears, indicating that the
function of the center point cursor is closed.
Image mode
Press the “SET key” to pop up the main menu, select “Image mode” by using
the “Left/right key”, and then press the “SET key” to enter the sub-menu
options of image mode. You can make a selection by using the left/right key.
For example, press the “SET key” to select “Thermal imaging” to switch the
image to thermal imaging mode. (In the fusion mode, you can adjust the fusion
ratio by using the “Left/right key” and adjust the fusion distance by using
the “Up/down key”. In the picture in picture mode, you can change the position
and size of the picture in the picture by selecting Move or Stretch by using
the “Left/right key”. Press the “SET key” to select “QR code”, you can
manually enter the QR code or scan the code to obtain the QR code, and select
“Cancel” to return to the main page).
Swatches switching
Press the “SET key” to pop up the main menu options, select “Swatches Switch”
by using the “Left/right key”, select the required swatches by using the
“Left/right key”, and there are seven swatches available: white hot, red hot,
iron red, black hot, high rainbow, lava, and rainbow.
Temperature measuring tool
Press the “SET key” to pop up the main menu options, and select “Temperature
measuring tool” by using the “Left/right key”. By using the “Left/right key”,
select the analysis object type (including point temperature measurement, line
temperature measurement, rectangle, and circle) and select the target (this
function can be used only when the analysis object is added to the home page).
Clear all and preset tools.
After pressing the “SET key” to clear all functions, all temperature measurement analysis objects on the current page will be cleared.
If there is a temperature measurement analysis object on the home page, press the “SET key” to select the preset tool, and the “Save Tool” prompt box will pop up. If you select OK, the current analysis object will be saved and the preset tool can be used next time. If there is no temperature analysis object on the home page, press the “SET key” to select the preset tool, and the Read Tool dialog box will be displayed. If you select OK, the preset tool saved last time will be added to the home page.
Note
A maximum of five-point temperature measurement analysis objects can be
added. For the line temperature analysis object, it can be added only one. A
maximum of three rectangular and circular temperature analysis objects can be
added. The total number of temperature measurement analysis objects cannot
exceed six. If the number of analysis objects exceeds the threshold, will not
add any analysis objects and will display the message” Outnumber”.
Vitta tool
Press the “SET key” to pop up the main menu, and select “Vitta Tool” by using
the “Left/right key”. Select the desired Vitta tool by using the “Left/right
key”. Six isothermal modes can be selected: Auto isothermal, Proportional
isothermal, Down isothermal, Up isothermal, Interval isothermal, and Manual
isothermal.
Photo view and edit
On the main page, press the “Photo view key” to enter the multimedia view.
Press the “Up/Down key” to select all photos/videos or other folders, and
press the “SET key” to enter. Press the “Up/Down/Left/Right key” to select the
picture you want to view, press the “SET key” to view the picture, and switch
the picture using the “Left/right key”.
Press the “SET key”, and the picture interface sub-menu will appear, press the “Left/right key” to select the photo message and modify remarks (after adding remarks, you can view them in the photo message), state edit (it can be used for second editing of the marking tool, image mode, swatches switch, temperature measurement tool, vitta tool and other functions on the original picture, and the function is the same as the main page function), QR code (it can be added to the existing QR code for picture classification. After classification, you can view the corresponding QR code classification pictures in different folders, and can also delete the QR code of the current picture or add a new QR code. The new QR code is not added here for folder classification), and delete photos.
Press the “SET key” to add a point, line, rectangle, and circle temperature measurement analysis object, and the sub-menu bar of “Select the target” will pop up automatically. Select the required functions by using the “Left/right key”, including the following functions: select, move, stretch (for the point temperature measurement analysis object, it cannot be stretched), comparing (for the point temperature measurement analysis object, it can only be compared with point temperature measurement analysis object, and corresponding comparison information will be displayed on the right after comparison), and delete (only the currently selected temperature measurement analysis object can be deleted). After adding the temperature measurement analysis object, the corresponding temperature information will be displayed on the left side. When selecting the line temperature measurement analysis object, the temperature curve of the line area will be displayed in the lower left corner.
Note: After editing on the status editing page, press the “SET key” to open the status editing sub-menu, select Recovery by using the “Up key”, and press the “SET key” to restore the picture to the initial state. After editing, press the “Back key”. The message Exit or Not will be displayed. If you select Exit, the editing page is directly exited. If you select Save, the message”Cover or not?” will be displayed. If you select Cover, change the original image and save it, then back to the view page. If you select New, the original image will not be changed, one new image will be added and back to the view page.
After adding the QR code, press the “Back key” and the message”Save and exit” will pop up to confirm, then the added QR code will be saved. If you select Cancel, the QR code will not be saved, and exit the QR code editing page. For the QR code added here, it will not be saved to the existing QR code category. If you need to modify the existing QR code, just modify it in the Settings.
Digital amplification & fusion ratio adjustment
On the home page, press the “Up key” to enlarge the screen, and the
corresponding magnification factor will be displayed in the upper right corner
of the screen. For the switch of magnification factor, it is switched with the
cycle of 1X, 2X, 4X, and 1X. On the home page, press the “Left and right key”
to adjust the degree of fusion. The degree of fusion adjustment is 0%, 25%,
50%, 75%, and 100% respectively.
System setup
Press the “SET key” to enter the sub-menu, and select different Settings by
using the “Up/Down key”. Press the “SET key” to enter the secondary page for
settings, including camera mode, units, parameters, alarm, QR CODE, language,
date, time, Wi-Fi, USB mode, brightness, automatic shutdown, factory reset,
and Settings. Click the “Back key” to return to the first-level menu on the
settings page, and click the “Back key” again to return to the main menu.
Camera mode
After entering the first level menu on the Setting page, select the “Camera
mode” option, press the “SET key” to enter the sub-menu of “Camera Mode”, and
use the “Up/Down key” to select Photo/Auto photo. If select automatic photo
taking, press the “Up/Down key” to set the automatic photo taking interval
(10s-1000s is optional).
Units
After entering the first-level menu on the Settings page, select the “Units”
option and press the “SET key” to enter the sub-menu of “Units”. Use the
“Up/Down key” to select the temperature/ distance. When selecting a
temperature, press the “Up/Down key” to select the temperature unit (°C /K/℉).
For distance units, they cannot be changed.
Parameters
After entering the first-level menu of the Settings page, select the
“Parameter” option and press the “SET key” to enter the sub-menu of
“Parameter”. Select emissivity/ambient temperature/reflected
temperature/relative humidity/object distance/Temperature through the “Up/Down
key”. Press the “SET key” to select the parameter you want to change, and
press the press “Up/Down key” to select the value for the parameter. When
setting the object distance parameter, press the “SET key” to enter the
“Object distance” sub-menu, and then use the “SET key” and the “Up/Down key”
to modify the parameter. Low temperature scale: -20°C~150°C High temperature
scale: 0~550°C
Note: It takes about 20 seconds to switch the temperature scale. Wait until the switch is stable before performing other operations or measuring the temperature.
- Please refer to the 18 Emissivity table;
- If you cannot determine which value to use, it is recommended to use the following default values:
- Emissivity 0.95
- Ambient temperature 25℃
- Reflected temperature 25℃
- Relative humidity 55%RH
- Object distance 0.25m
Note: Emissivity and reflected temperature are the two most important parameters that need to be set correctly.
If you are in doubt, please use the default values. After entering the first- level menu of the Settings page, select the “Parameter” option and press the “SET key” to enter the sub-menu of “Parameter”. Select emissivity/object distance through the “Up/Down key” and press the “SET key” to select parameters to be changed. Press the “Up/Down key” to select the value for the parameter. When setting the object distance parameter, press the “SET key” to enter the sub-menu of “Object distance”, and then use the “SET key” and the “Up/Down key” to modify the parameters.
Alarm
After entering the first-level menu on the Setting page, select the “Alarm”
option, press the “SET key” to enter the sub-menu of “Alarm”, and select the
high-temperature alarm/low-temperature alarm /LED alarm by using the “Up/Down
key”. When selecting high-temperature alarm/low-temperature alarm, select high
/low-temperature alarm value by using”Up/Down key”, press the “SET key” to
select, and set the required value by using”Up/Down key” (UTi720E: -20℃-550℃
optional, and UTi730E: -40℃~400℃ optional).
When the temperature of the measured object exceeds the high-temperature alarm
temperature value, the red positive triangle will pop up. When the temperature
of the measured object is lower than the low-temperature alarm temperature
value, the green
inverted triangle will pop up.
QR CODE
After entering the first-level menu on the Setting page, select the “QR CODE”
option and press the “SET key” to enter the QR CODE sub-menu. Select different
QR Codes by using the “Up/Down key” and press the “SET key” to enter the
change page for the QR CODE name /CODE.
Language
After entering the first-level menu on the Setting page, select the “Language”
option and select English, French, German, Spanish, or Russian by using the
“Up/Down key”.
Date and time
After entering the first-level menu on the Setting page, select Date and Time
and press the “SET key” to enter the submenu of Date and Time. Press the “SET
key” to change the time system/ date/time, and change the value by using the
“Up/Down key”. For example, if you want to change the date, select the change
of year/month/day by using the “Left/Right key”, and select the specified date
by using the “Up/Down key”.
Wi-Fi
After entering the first-level menu on the Setting page, select the Wi-Fi
option and press the “SET key” to enter the sub-menu. Press the “SET key” to
open the hotspot, press the “Down key” to select the Hotspot ID and password,
and set up by using the “SET key”.
USB mode
After entering the first-level menu on the Settings page, select the “USB
mode” option and press the “SET key” to enter the Sub-menu of “USB mode”.
Select “USB storage /USB Projection” by using the “Up/Down key” and press the
“SET key” to select.
Brightness
After entering the first-level menu on the Setting page, select the
“Brightness” option, and select the intensity of brightness (1-100) by using
the “Up/Down key”.
Automatic Shutdown
After entering the first-level menu on the Setting page, select the “Automatic
Shutdown” option, and select Off /5 /10 /20 /30 /45 /60 /90 by using the
“Up/Down key”.
Factory reset
After entering the first-level menu on the Settings page, select the option of
“Factory reset” option, press “SET key”, and the prompt “Shutdown and factory
reset” will pop up. If you select Yes, the device will automatically shut
down, and the instrument will restore factory settings after manual startup.
Formatting
After entering the first-level menu on the Settings page, select the
“Formatting” option and press the “SET key”. If there is an SD card, the
message “format SD card” will pop up? If you select Yes, will format the SD
card. If there is no SD card, the message “Unknown” will be displayed.
About
After entering the first-level menu on the Settings page, select the “About”
option and press the “SET key” to enter the sub-menu of “Product Information”.
Then you can view the product model, infrared resolution, hardware version,
system version, SN, SD capacity, and other related product information.
SD Card
The device supports microSD cards to store images. To prevent excessive image
data from affecting the operating speed, should periodically copy backup data
and clear the data in the card. To avoid data abnormalities caused by a hot
swap, do not remove or insert the SD card repeatedly. Try to remove or insert
the SD card when it is powered off. If you remove the SD card when viewing or
operating an image, the message “SD card is lost” will be displayed.
Maintain
Clean the structural housing with a damp cloth or weak soapy solution. Do not
use the grinder, isopropyl alcohol, or solvent to clean the lens/window of the
instrument housing.
Safety precautions
To guarantee the accurate measurement results, please read the instructions
carefully. Please be sure to use the product according to the instructions,
otherwise, the product will not be free of warranty after damage. Do not use
the instrument in an inflammable, explosive, humid, or corrosive environment.
Do not continue to use the instrument when it is damaged, broken, or
corrected, which will cause wrong test results. Obtain the actual temperature
by referring to the radiation coefficient information; otherwise, the measured
temperature may be inaccurate.
Do not aim the lens at the hot light source, like the sun, to avoid damage to the lens or thermal imaging detector. Do not use the product in an extremely hot, cold, dusty, or high-humidity environment. For specific requirements on temperature and humidity, please see the product parameter table. The system supports a USB cable to charge the device but to improve charging efficiency, it is recommended to remove the battery pack and charge the battery pack separately.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Warranty
Triplett Test Equipment and Tools extends the following warranty to the
original purchaser of these goods for use. Triplett warrants to the original
purchaser for use that the products sold by it will be free from defects in
workmanship and material for a period of (1) one year from the date of
purchase. This warranty does not apply to any of our products that have been
repaired or altered by unauthorized persons in any way or purchased from
unauthorized distributors so as, in our sole judgment, to injure their
stability or reliability, or which have been subject to misuse, abuse,
misapplication, negligence, accident or which have had the serial numbers
altered, defaced, or removed. Accessories, including batteries, are not
covered by this warranty Copyright © 2024 Triplett
www.triplett.com
Common emissivity table
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Wood | 0.85 | Black paper | 0.86 |
Water | 0.96 | Polycarbonate | 0.8 |
Brick | 0.75 | Concrete | 0.97 |
Stainless steel | 0.14 | Copper oxide | 0.78 |
Tape | 0.96 | Cast iron | 0.81 |
Aluminum plate | 0.09 | Rust | 0.8 |
Copper plate | 0.06 | Gypsum | 0.75 |
Black aluminum | 0.95 | Paint | 0.9 |
Human skin | 0.98 | Rubber | 0.95 |
Asphalt | 0.96 | Soil | 0.93 |
PVC | 0.93 |