INTENDED USE OF DEVICE
The head is designed to be mounted on the thermostatic valve of the radiator, either directly or via an adapter.
TECHNICAL INFORMATION
Model markings | VAZ |
---|---|
Power supply | 6700 mAh (24.12Wh) battery pack |
Appliance class | Class III |
Threaded nut | M30 x 1,5 |
IP code*** | IP20 |
Wi-Fi | 2,4 GHz 802.11 b/g/n |
TREATMENT OF ELECTRICAL AND ELECTRONIC EQUIPMENT WASTE:
Pursuant to the regulations in force for used electric and electronic equipment, products marked with the symbol of separate collection cannot be placed with other municipal waste. Due to the content of harmful substances, electronic products not subjected to the selective sorting process may be dangerous to the natural environment and to human health. The correct separate collection of used electrical and electronic equipment prevents negative impacts on the environment.
INFORMATION CONCERNING THE WASTE COLLECTION SYSTEM FOR ELECTRICAL AND ELECTRONIC EQUIPMENT IS AS FOLLOWS:
- A distributor accepts and collects electrical and electronic equipment waste from households free of charge, provided that the equipment is of the same type and performs the same functions as the equipment purchased,”
- a collecting operator have the right to refuse to accept the waste equipment if it poses a threat to the health or life of individuals receiving the equipment due to contamination,
- the user of equipment intended for households may hand over the used equipment to:
— a distributor,
— a waste processing plant,
— collecting municipal waste in the commune.
Further information can be found on the government website: www.hse.gov.uk/waste/waste-electrical.htm
TERMA SMART WI-FI SYSTEM AND DEVICES
DESCRIPTION OF THE SMART SYSTEM
Terma Smart Wi-Fi is an intelligent heating system, all elements of which communicate using Wi-Fi technology. In addition to the standard operation, i.e. maintaining the set air temperature in the rooms, the user can control the system using the Terma SMART mobile application. Thanks to this application, it is possible to program seven-day schedules, initiate an early start mode, and divide the heated area into heating zones (several other functions are also included).
NOTE: For the initial set-up and registration of the devices, a router
with Internet access is required (provided by the system user). A Wi-Fi router
is responsible for delivering a wireless signal to each of the system
components. Further information can be found in the chapter — SMART System —
information about the system and application, as well as on the website
www.termasmart.com
Each of the devices can function independently, however, the recommended
structure of the system consists of heating zones, e.g. individual rooms in
the house, which may include one (as a maximum) VTS temperature sensor per
room and any number of other types of devices and sensors. Terma SMART Wi-Fi
heating devices will function at an optimum level when connected permanently
to a local Wi-Fi network with Internet access. The devices will also function
without access to the Internet, or even without a Wi-Fi connection, but in
this case the previously loaded schedule will be implemented, and many of the
device functions will remain unavailable.
THERMOSTATIC HEAD TERMA SMART VAZ
|
---|---
market://details?id=com.termaconnect.mobile|
itms-
apps://itunes.apple.com/app/id1498219351
COMMISSIONING AND INSTALLING THE HEAD
-
Install the SMART application on your mobile device, grant the appropriate approvals relating to the location and operation of the scanner.
-
Create a user account and provide basic details of the newly created ʻhouse’.
-
Prepare a password for the local Wi-Fi network.
-
Switch on the head and start the PAIRING:
a. The new device can be started with a short press on either of the + or − buttons on the front panel. All LED strips will flash three times and the + / − buttons will flash steadily, the device will go into PAIRING MODE for 5 minutes.
b. If the pairing mode does not start automatically, or if the device is restarted, press both buttons + and − simultaneously and hold them for approx. 15 seconds (the entire display flashes every 5 seconds, after the third flash, release the buttons. All LED strips will flash 3 times and the + / − buttons will start flashing steadily, the device will go into PAIRING MODE for 5 minutes.).
NOTE: from now on, the device broadcasts its network address (signal) and is seen by the SMART application.
c. Launch the SMART application and go to the Devices screen.
d. Select the + button and follow the instructions in the application (first scan the code from the sticker on the device (Fig.3) or enter it manually, select the local Wi-Fi network and enter the router password, then from the list of available devices, select the device currently being added). e. When the automatic part of the process is over, select the appropriate zone in the application (or create a new one) and enter the device name and other data. -
Before mounting the head on the radiator press the ‘-’ button for 5 seconds to activate the maximum opening mode of the head.
-
Install the head on the valve.
NOTE: If the valve does not fit the head, use an adapter -
The Terma VAZ Smart thermostatic head is ready for operation.
OPERATING THE HEAD VIA THE INTERFACE PANEL
White stripes | 5 stripes | 26°C |
---|---|---|
4 strips | 24°C | |
3 strips | 21°C | |
2 strips | 18°C | |
1 strip | 15°C | |
Red stripe | In the appendix, the temperature of 28°C is enabled. |
-
To wake up the device from the sleep mode, briefly press any button.
-
To raise or lower the temperature by one step, briefly press + or − button.
-
To swap the + and −, buttons, press and hold (> 10 s) the + button.
-
Modes and special actions — press and hold both + and − buttons simultaneously:
a. for 10 s — the heating element will be put to sleep (stand-by mode) (single flash on the interface);
b. for 15 s — enter pairing mode (AP) all interface will flash 3 times; c. for 25 s — restore factory settings and start the pairing mode, the de- vice will flash as it did at set-up; -
If the head controller panel has been blocked (the PARENTAL CONTROL function in the control application), pressing the + key for 5 seconds will release the lock for 1 minute, which will allow you to change the settings manually on the device without the need to use the application (confirmation by flashing interface).
The change made on the device manually is valid until the next automatic temperature change saved in the schedule.
ADDITIONAL COMMENTS ON ADDING DEVICES TO THE TERMA SMART SYSTEM
(APPLIES TO ALL SMART DEVICES)
- Adding devices is possible only via the mobile application.
- System changes are sent locally by the router, and to the cloud service by the application.
- In some Android system overlays, during pairing, the phone tries to automatically switch to the remembered Wi-Fi network with Internet access — you must manually confirm the connection with the device’s network.
- After adding the heating devices to the system, they are turned off by default (they do not heat up, despite the low ambient temperature, the interface bars are not lit, and the remote communication interval is 1 h).
- Heating devices should be added first, followed by the sensors.
- There can be only one temperature and humidity sensor (VTS) in one heating zone.
- The option of ʻcombine into a set’ is available only for the heating element and the thermostatic head installed in the same central heating radiator, and only during the installation of the second device.
- The name of each device must be unique within the system.
- The name of the zone must be unique within the system.
SMART SYSTEM — BASIC INFORMATION ABOUT THE SYSTEM AND THE APPLICATION
HEATING ZONES
In the application, a newly created ʻhouse’ should be divided into heating
zones (e.g. rooms) to which individual devices are assigned. It is possible to
select a schedule and view telemetry data for each zone. The list of all zones
is visible to the user in the Zones tab. The view of a single zone contains a
set of actions and information available to the user.
The temperature presented in the center of the screen of a single zone is the
current measured temperature, while the value at the bottom is the set
temperature that depends on the mode in which the system is currently
operating:
- if the Vacation mode is active, the Vacation mode temperature is displayed
- if the Smart Location is active, the temperature for the Smart Location is displayed
- if at least one device is in the manual mode, the temperature set for the manual mode is displayed — the icon
- otherwise, the temperature for a given time interval will be displayed according to the schedule — icon
PRINCIPLES OF MEASURING THE TEMPERATURE IN THE ROOM (IN THE ZONE):
- If there is a temperature and humidity sensor (VTS) in a zone, its indications are the basis for the temperature control for all devices in a given zone (recommended configuration);
- If there is no VTS sensor in the zone, the devices will operate based on the average of the sensor readings of each device (or one sensor if one device is in the zone).
A more detailed description of the SMART System can be found on www.termasmart.com
Warranty terms & conditions
-
The subject of the warranty is the thermostatic head SMART VAZ manufactured by Terma Sp. z o.o. The product name and characteristics are specified on the packaging.
-
By accepting the device on purchase, the Client confirms that the product is of full value. The Client should immediately inform the Seller of any discovered faults — otherwise it will be understood that the Product was faultless at the time of purchase. This refers especially to any faults or damages of the control panel case.
-
The Warranty for period for the Product is 24 months from the date of purchase, but no longer than 36 months from the date of production.
-
The proof of purchase (receipt, invoice, etc.) constitutes the basis for warranty claims. Lack of the proof of purchase allows the manufacturer to reject a warranty claim.
-
This warranty does not cover any faults and/or damages caused by:
— incorrect (not in accordance with the manual) installation, use or disassembly,
— incorrect use of the heating element (i.e. for any purpose that is not specified by the Manufacturer as intended for this type of product),
— unqualified persons tampering with the product,
— customers after the purchase. -
The Central Heating installation should be fitted with lock-shield valves, enabling disassembly of the radiator or the heating element and its control head without the necessity of emptying the whole system of the heating agent. Any problems or expenses arising from the absence of lock-shield valves in your installation cannot be used as grounds for any claims against Terma.
-
The attached Product Manual is an integral element of the Warranty. Please read it carefully prior to the installation and use of the Product.
-
The Manufacturer is obliged to remove any production fault within 14 working days of receipt of the faulty device at the Manufacturer’s premises.
-
Should the repair be impossible, then the manufacturer is obliged to replace the faulty Product with a new, full-value unit of identical parameters.
TERMA Sp z o. o.
Czaple 100, 80-298 Gdańsk, Poland
terma@termagroup.pl
www.termaheat.com
MGKE-730 20240411 CIBTO
References
Read User Manual Online (PDF format)