Autonics TCD210092AC Top Bottom Terminal SSR with Integrated Heatsink User Manual
- August 20, 2024
- Autonics
Table of Contents
- Autonics TCD210092AC Top Bottom Terminal SSR with Integrated Heatsink
- Product Information
- Features
- Safety Considerations
- Cautions during Use
- Ordering Information
- Product Components
- Dimensions
- Cautions during Installation
- Connections
- Specifications
- SSR Derating Curve
- Operation Mode
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Autonics TCD210092AC Top Bottom Terminal SSR with Integrated Heatsink
Product Information
The TCD210092AC is a single-phase SSR (Solid State Relay) with top/bottom terminals and an integrated heatsink. It belongs to the SRH1 Series by Autonics. This SSR is designed for current input type applications and features fail-safe mechanisms for safety.
Specifications:
- Model: TCD210092AC
- Series: SRH1 Series
Safety Considerations
- Install fail-safe device for high-risk machinery.
- Avoid use in areas with flammable/explosive/corrosive gases, high humidity, direct sunlight, vibration, etc.
- Install the unit on DIN rail or panel.
- Avoid connecting, repairing, or inspecting the unit while connected to power.
- Check connections before wiring.
- Do not disassemble or modify the unit.
Cautions:
- Operate within rated specifications.
- Clean with a dry cloth and avoid water or organic solvents.
- Keep away from metal chips, dust, and wire residue.
- Avoid touching load terminal immediately after power off.
Product Components:
The product includes components required for its operation as per the SRH1
series standards.
Dimensions:
- Rated load current: 20 / 30 A
- Dimensions: 100 x 31 x A
Cautions during Installation:
- High Temperature: Avoid touching the body and heatsink while power is supplied or right after turning off the power to prevent burns due to high surface temperature.
- Spacing: Ensure to supply less than 50% of the rated load current to prevent overheating.
Frequently Asked Questions (FAQ):
-
Q: What should I do if I encounter a fail-safe situation with the SSR?
A: In case of a fail-safe scenario, immediately disconnect the power source and consult the Autonics website or contact customer support for assistance. -
Q: Can the SSR be used in high humidity environments?
A: It is not recommended to use the SSR in high-humidity environments as it may lead to malfunction or damage. Please refer to the safety considerations for more details on environmental restrictions.
For your safety, read and follow the considerations written in the instruction
manual, other manuals and Autonics website.
The specifications, dimensions, etc. are subject to change without notice for
product improvement. Some models may be discontinued without notice.
Features
- High heat dissipation efficiency with ceramic PCB and integrated heatsink
- Input Indicator (green)
- DIN rail mount or panel mount installation
- Phase control (power equality division/phase equality division), cycle control (fixed cycle/variable cycle)
- Improved dielectric strength: 4,000 VAC ~
Safety Considerations
- Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
- symbol indicates caution due to special circumstances in which hazards may occur.
Warning: Failure to follow instructions may result in serious injury or death.
-
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss.(e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, economic loss or fire. -
Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present.
Failure to follow this instruction may result in explosion or fire. -
Install the unit on DIN rail or panel to use.
Failure to follow this instruction may result in fire or electric shock. -
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire or electric shock. -
Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire. -
Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire or electric shock.
Caution: Failure to follow instructions may result in injury or product damage.
-
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage. -
Use a dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire or electric shock. -
Keep the product away from metal chip, dust, and wire residue which flow into the unit.
Failure to follow this instruction may result in fire or product damage. -
Since leakage current still flows right after turning off the power or in the output OFF status, do not touch the load terminal.
Failure to follow this instruction may result in electric shock.
Cautions during Use
- Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
- Install the unit in the well ventilated place.
- Ground to the heatsink, panel, or DIN rail. Failure to follow this instruction may result in electric shock.
- While supplying power to the load or right after turning off the power of the load, do not touch the body and heat sink. Failure to follow this instruction may result in burn due to high temperature of the surface.
- In order to protect the product from the short-circuit current of the load, use rapid fuse of which I2t is under the 1/2 of SSR I2t. When short-circuited, replace the fuse to those of same specification with the used rapid fuse.
- Install dummy resistance in parallel with the load, to keep the sum of current flowing in the load and dummy resistance being over SSR minimum load current.
- Do not use near the equipment which generates strong magnetic force or high frequency noise.
- This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000 m
- Pollution degree 2
- Installation category III
Ordering Information
This is only for reference, the actual product does not support all combinations. For selecting the specified model, follow the Autonics website .
-
Rated input
A: 4 -20 mA -
Rated load voltage
2: 100 – 240 VAC ~
4: 200 – 480 VAC ~ -
Rated load current
Number: Rated load current (unit: A) -
Function
No-mark: Zero cross turn-on
R: Random turn-on
Product Components
- Product
- Instruction manual
Dimensions
- Unit: mm, For the detailed drawings, follow the Autonics website.
- When installing to the panel, tightening the screw with a torque of 1.8 to 2.5 N m.
Cautions during Installation
Caution High Temperature
While supplying power to the load or right after turning off the power of
the load, do not touch the body and heat sink. Failure to follow this
instruction may result in burn due to high temperature of the surface.
Spacing
- When installing multiple SSRs, be sure to keep space between SSRs for heat radiation.
- When installing SSRs horizontally (input part and output part on the same height), be sure to supply less than 50 % of the rated load current.
DIN rail mounting
- For attachment, hang the upper part of the Rail lock on the rear of the product to the DIN rail, and push the product toward the DIN rail.
- For detachment, Press the product down, and pull it forward.
Grounding
- Ground the DIN rail.
Connections
- When connecting the CAP (capacitor), it is appropriate for EMC.
- Rated load voltage 100 – 240 VAC ~ : 1 uF / 250 VAC ~
- Rated load voltage 200 – 480 VAC~: 0.47 uF / 500 VAC ~
Cautions for Wiring
- Unit: mm, When connecting the wire to the terminal, use the round crimp terminal.
Specifications
Input
Rated input current | 4 – 20 mA |
---|---|
Max. allowable input current | 50 mA |
Pick-up current | ≥ 4.2 mA |
Static off current | ≤ 4.0 mA |
Power factor | ≥ 0.9 (difference between voltage phase and current |
phase: ≤ 25 °)
Start-up time| 60 Hz: 200 ms / 50 Hz: 250 ms
Operating time| 60 Hz: 16.6 ms / 50 Hz: 20 ms
Operating mode 01)| Phase control
(power equality division type / phase equality division type)
Cycle control
(variable cycle / fixed cycle)
You can change operation mode by jumper pin. Default is Phase control (power equality division type). For more information, see the ‘Operation Mode.’
Output
Rated load voltage range| 100 – 240 VACrms ~****
(50 / 60 Hz)
| 200 – 480 VACrms ~****
(50 / 60 Hz)
---|---|---
Allowable load voltage range| 90 – 264 VACrms ~
(50 / 60 Hz)
| 200 – 528 VACrms ~
(50 / 60 Hz)
Rated
load current
| Resistive load
(AC-51) 01)
| 20 Arms| 30 Arms| 60 Arms| 20 Arms| 30 Arms| 60 Arms
Min. load current| 0.5 Arms| 0.5 Arms
Max. 1 cycle surge current (60 Hz)| 300 A| 500 A|
1000 A| 300 A| 500 A| 1000 A
Max. non-repetitive surge current (I 2t, t =
8.3 ms)| 350 A2s| 1000 A2s| 4000 A2s| 350 A2s| 1000 A2s| 4000 A2s
Peak voltage (non-repetitive)| 600 V| 1000 V
Leakage current (Ta = 25 ℃)| ≤ 10 mArms
(240 VAC ~ / 60 Hz)
| ≤ 10 mArms
(480 VAC ~ / 60 Hz)
Output ON voltage drop [Vpk] (max. load current)| ≤
1.6 V
Static off state dv/dt| 500 V/μs
AC-51 is utilization category at IEC60947-4-3.
General specifications
Output range (phase control) | 0 – 99 % |
---|---|
Frequency reading function | YES |
Dielectric strength (Vrms) | Between the charging part and the |
case: 4000 VAC ~ 50 / 60 Hz for 1 min
Insulation resistance| ≥ 100 MΩ (500 VDC ~ megger)
Indicator| Input indicator (green)
Vibration| 0.75 mm double amplitude at a frequency of 10 to 55 Hz in
each X, Y, Z direction for 1 hour
Ambient temperature 01)| -20 to 70 ℃, storage: -20 to 100 ℃ (no
freezing or condensation)
Ambient humidity| 45 to 85 %RH, storage: 45 to 85 %RH (no freezing
or condensation)
Input terminal connection| ≥ 1×0.5 mm2 (1×AWG 20),
≤ 1×16 mm2 (1×AWG 6) or ≤ 2×1.5 mm2 (2×AWG 16)
Output terminal connection 02)| ≥ 1×1.5 mm2 (1×AWG 16),
≤ 1×16 mm2 (1×AWG 6) or ≤ 2×6 mm2 (2×AWG 10)
Input terminal fixed torque| 0.75 to 0.95 N m
Output terminal fixed torque| 1.6 to 2.2 N m
Approval|
Weight| Rated load current 20 / 30 A: ≈ 410 g Rated load current 60 A: ≈
680 g
- See the ‘SSR Derating Curve’ in the product manual because the capacity of the rated load current is differ depending on the ambient temperature.
- Connect the wire met the capacity of the load current to the output terminal.
SSR Derating Curve
- Be aware that the ambient temperature and the derating curve is different by the rated input voltage when using the product.
- Since the effectiveness of the heat radiation is decreased when SSRs are installed closely, be sure to supply less than 50 % of the rated load current.
- SSR derating curves obtained approval from the UL certification authority.
Operation Mode
Phase control
- Output waveform of phase control.
Cycle control
- Fixed cycle: controls continuously the number of full cycle which is supplied to load every 1 sec by being proportional to the control input (4 – 20 mA).
Detach front cover
Press the front cover connections (4 parts) at the right and left side with
(-) driver, and front cover is detached. Before detaching the front cover, be
sure to cut off the load current and input.
Jumper pin setting
The operation mode is changed by the jumper position. After changing the
operation mode, supply the input signal again.
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>