Power Film SOLAR AEM10941 Solar Development Kit User Guide

June 4, 2024
Power Film SOLAR

MADE IN THE USE
Quick Start Guide

AEM10941 Solar Development Kit

Solar Development Kit with e-peas PMIC and CAP-XX Supercapacitors

Step 1: AEM10941 Configuration
MPPT Ratio: Defined to 70%
Storage Element Voltages Protection: CFG2-CFG1-CFG0

Configuration pins| Storage element threshold voltages I| LDOs output voltages I| Typical use
---|---|---|---
| | | | | | | |
1| 1| 1| 4.12 V| 3.67 V| 3.60 V| 3.3 V| 1.8 V| Li-ion battery
1| 1| 0| 4.12 V| 4.04 V| 3.60 V| 3.3 V| 1.8 V| Solid state battery
1| 0| 1| 4.12 V| 3.67 V| 3.01 V| 2.5 V| 1.8 V| Li-ion; NiMH battery
1| 0| 0| 2.70 V| 2.30 V| 2.20 V| 1.8 V| 1.2 V| Single-cell supercapacitor
0| 1| 1| ‘
4.50 V| 3.67 V| 2.80 V| 2.5 V| 1.8 V| Dual-cell supercapacitor
0| 1| 0| 4.50 V| 3.92 V| 3.60 V| 3.3 V| 1.8 V| Dual-cell supercapacitor
0| 0| 1| 3.63 V| 3.10 V| 2.80 V| 2.5 V| 1.8 V| LiFePO4 battery
0| _ 0| 0| Custom mode – Programmable through R1 to R6| 1.8 V|

BAL Option: Select “CON” for dual-cells supercapacitor and “GND” for any other storage.
PRIM Option: Connect both jumpers “NoPRIM” or remove them if a primary battery is connected.
Define minimum voltage using R7 and R8.

  • 100 kΩ RP < 500 kΩ
    • R8=RP-R7

LDOs Output Voltages: ENHV [HVOUT] – ENLV [LVOUT]

ENLV ENHV LV output HV output
1 1 Enabled Enabled
1 0 Enabled Disabled
0 1 Disabled Enabled
0 0 Disabled Disabled

Step 2: Connect the storage element or solder a CAP-XX supercapacitor on the bottom layer (refer to the table on the following page)

Step 3 : Connect the Load(s) to HVOUT / LVOUT

Step 4 : Connect the PowerFilm Photovoltaic module to SRC
Step 5 : Set up complete! See User Guide for additional details and advanced configurations.

Package name Footprint Comment
DMF/DMT ![](https://manuals.plus/wp-content/uploads/2022/08/Power-Film-SOLAR-
AEM10941-Solar-Development-Kit-fig4.png) Use Jumper to Connect “BAL”to “ToCN”
DMH ![](https://manuals.plus/wp-content/uploads/2022/08/Power-Film-SOLAR-
AEM10941-Solar-Development-Kit-fig5.png) Use Jumper to Connect “BAL” to

“ToCN”
This model is not delivered in this evaluation kit
A| | Use Jumper to Connect “BAL” to “ToCN”
This model is not delivered in this evaluation kit
Dual cell S/W| | Use Jumper to Connect “BAL” to “ToCN”
This model is not delivered in this evaluation kit
Single cell S/W| | Use Jumper to Connect “BAL” to “GND”
To fit on the board, the supercapacitor must be flipped on its back This model is not delivered in this evaluation kit

Table 7: Footprint description
This footprint is available on the inferior face of the PCB. The red colour represents the positive voltage, the blue is the ground and the black is to be connected to the balancing pin. Those three potentials are available on the screw terminal on the top side.

PowerFilm, Inc. • 1287 XE Place • Ames, IA 50014 USA •www.powerfilmsolar.com515-292-7606

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals