BITMAIN S9 T19 Pro Hyd. Anti Miner Hydro Server Installation Guide
- August 17, 2024
- BITMAIN
Table of Contents
BITMAIN S9 T19 Pro Hyd. Anti Miner Hydro Server
Specifications
Product Glance | Value |
---|---|
Model | T19 Pro Hyd. k0-10 |
Version | T19 Pro Hyd. |
Crypto algorithm/coins | SHA256 |
Typical Hashrate, TH/s(1-1) | 246 |
Power on wall @35(1-2), Watt(1-1) | 5412 |
Power efficiency on wall@35(1-2), J/TH(1-1) | 22.0 |
Detailed Characteristics
Power supply | Phase: 3 |
---|---|
Hardware configuration | Network connection mode: RJ45 Ethernet 10/100M |
Server size (LengthWidthHeight, w/o package), mm | 410170209 |
Server size (LengthWidthHeight, with package), mm | 570316430 |
Net weight, kg | 12.8 |
Gross weight, kg | 14.1 |
Environment requirements | Coolant flow, L/min: 8.0~10.0 |
Coolant pressure, bar: 3.5 | |
Working coolant: Antifreeze/Pure water/Deionized water | |
Coolant pH value: Antifreeze (7.0~9.0), Pure water (6.5~7.5), |
Deionized water (8.5~9.5)
| Diameter of coolant pipe connector, mm: OD10
Product Usage Instructions
- Power Supply and Hardware Setup
- Ensure the power supply phase is set to 3 and connect the server to a power source within the voltage and frequency range specified (380~415V, 50~60Hz).
- Connect the server to the network using an RJ45 Ethernet cable for a stable connection.
- Place the server in a suitable location with dimensions of 410mm in length, 170mm in width, and 209mm in height.
- Coolant System Setup
- Ensure the coolant flow is maintained between 8.0 to 10.0 L/min and the pressure is at 3.5 bar.
- Use the recommended coolants such as Antifreeze, Pure water, or Deionized water based on the specified pH values.
- Connect the coolant pipe with a diameter of OD10 securely to the server for efficient cooling.
- Environmental Considerations
Maintain the operating environment temperature between 20 to 50 degrees Celsius and humidity levels between 10% to 90% non-condensing.
Frequently Asked Questions (FAQ)
-
Q: Can I use any type of coolant for this server?
A: No, it is recommended to use Antifreeze, Pure water, or Deionized water based on the specified pH values for optimal performance and longevity of the server. -
Q: What is the ideal power supply configuration for this server?
A: The server requires a three-phase power supply with an input voltage range of 380~415V and a frequency range of 50~60Hz for proper functioning.
T19 Pro Hyd.
Product Manual
BITMAIN TECHNOLOGIES INC.
Specification
Product Glance | Value |
---|---|
Model | T19 Pro Hyd. |
Version | k0- 10 |
Crypto algorithm/coins | **SHA256 |
Typical Hashrate, TH/s (1-1) | 246 |
Power on wall @35℃(1-2), Watt (1-1) | 5412 |
Power efficiency on wall@35℃(1-2), J/TH (1-1) | 22.0 |
Detailed Characteristics | Value |
--- | --- |
Power supply
Phase| 3
Input voltage, Volt (2-1)| 380~415
Input frequency range, Hz| 50~60
Input max current, Amp| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 410170209
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 12.8
Gross weight, k g| 14.1
Environment requirements
Inlet coolant temperature, °C| 20~50
Coolant flow, L/min| 8.0~10.0
Coolant pressure, bar| ≤3.5
Working coolant(2-2)| Antifreeze/ Pure water/Deionized water
Coolant pH value|
- Antifreeze: 7.0~9.0 Prue water: 6.5~7.5
- Deionized water : 8.5~9.5
Diameter of coolant pipe connector, mm| OD10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Notes:
- (1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
- (1-2) Inlet coolant temperature.
- (2-1) Caution: Wrong input voltage may cause server damaged.
- (2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
Performance Curve
- Hashrate vs. Inlet Coolant Temperature
- Power Efficiency vs. Inlet Coolant Temperature
- The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>