SOFAR MR600 Microinverter Installation Guide
- August 14, 2024
- SOFAR
Table of Contents
SOFAR MR600 Microinverter
Specifications
- Product Models: MR600, MR800, MR1000
- Output Power: Varies by model
- Input Voltage: Varies by model
- Efficiency: Varies by model
- Dimensions: Varies by model
Product Usage Instructions
Preparation
Refer to the microinverter reference wiring diagram for installation guidance:
- Install the microinverter underneath the PV modules in a shaded location.
- Maintain a distance of more than 15 mm between the microinverter and the PV modules for heat dissipation.
Installation Steps
- Ensure the microinverter is installed in a suitable environment matching the user manual guidelines.
- Check that the grid voltage matches the microinverter label voltage level.
Prepare the Corresponding Cables
Serial number | Descriptions | Source (of information etc.) |
---|---|---|
a | AC trunk cable | Own/purchase (refer to accessories list) |
b | AC cable | Own |
c | AC trunk plug | Purchase (refer to accessories list) |
d | AC trunk connector | Purchase (refer to accessories list) |
Size and Location
- Mount the microinverter on the bracket by following these steps:
- Mark the mounting position on the bracket according to the PV modules layout.
- Install two M6*25 mm cross slotted outer hexagon screws with nuts in the groove.
- Hang the microinverter on the screws and tighten the Phillips screws with a torque of 5.5 kgf.cm.
FAQ
Q: What should I do if components are missing or damaged upon delivery?
A: If any damage is found or components are missing, please contact your
dealer for assistance.
Q: Where can I purchase additional accessories listed in the manual?
A: You can contact SOFARSOLAR sales for details on purchasing or preparing the
additional accessories mentioned in the manual.
QUICK INSTALLATION GUIDE
MR600, MR800, MR1000
PRODUCTS
CHECKING DELIVERABLE
After unpacking the inverter, please check whether the delivery is complete
and whether there is any obvious external damage. If any damage is found or
any components are missing, please contact your dealer. The delivery list is
shown in the table below:
ACCESSORIES LIST
The list of accessories for the product is shown as below:
Note: The accessories in the table above are not included in the packing list, detailed specifications and models can be referred to the components list. You can contact SOFARSOLAR sales to purchase or prepare by yourself.
PREPARATION
Microinverter reference wiring diagram
PREPARE THE CORRESPONDING CABLES ACCORDING TO THE TABLE BELOW
Serial number | Descriptions | Source (of information etc.) |
---|---|---|
a | AC trunk cable | Own/purchase (refer to accessories list) |
b | AC cable | Own |
c | AC trunk plug |
Purchase (refer to accessories list)
d| AC trunk connector| Purchase (refer to accessories list)
Note: The accessories in the table above are not included in the product
delivery list and need to be purchased separately.
SOFARSOLAR provides some prefabricated cables and accessories. If you need,
please contact SOFARSOLAR sales for details.
SIZE AND LOCATION
- It is recommended to install the microinverter underneath the PV modules, please avoid direct sunlight, rain, snow, etc. as much as possible, and preferably choose a fully shaded location;
- The microinverter should ideally be more than 15 mm away from the PV modules above it to ensure that the inverter has a good space for heat dissipation.
INSTALLATION STEPS
Make sure the microinverter is installed in a reasonable environment (see product user manual for details: https://www.sofarsolar.com/service.html))
-
Step 1: Make sure that the grid voltage matches the voltage level on the microinverter label
-
Step 2: Mount the microinverter on the bracket
-
Please mark the mounting position of each microinverter on the bracket according to the layout of the PV modules. Put two nuts in the groove, then install two M6*25 mm cross slotted outer hexagon screws.
-
After hanging the microinverter from the screws on the bracket, tighten the Phillips screws with a torque of 5.5 kgf.cm.
-
Step 3: Install the antenna
After the microinverter is reliably mounted to the bracket, the Wi-Fi antenna is fixed to the microinverter. -
Step 4: Ground the microinverter
It must be properly grounded through the microinverter’s own grounding lug connection to the bracket. (Grounding cable needs to be prepared by yourself, 6 mm size is recommended) -
Step 5: Connect the microinverter AC cable
-
Please plan the proper location for the AC trunk cable to connect to the inverter first, then choose the proper AC extension cable according to the distance between the microinverters.
-
Install the AC trunk end cap at the end of the AC trunk cable.
-
Plug the microinverter AC terminal connector into the AC trunk connector. Please pay attention to the dire Attention:
To remove the microinverter AC connector from the AC trunk connector, use the AC disassembly tool and insert the tool into the side of the AC spur connector to complete the removal.
Unused trunk connector ports, please cover AC trunk branch cap. -
Step 6: Connect the microinverter and PV modules Connect the photovoltaic module interface to the DC input of the microinverter through the DC extension cable. A “click” sound indicates that the connection is successful.
-
Step 7: Create installation map
It is recommended to use an installation map to record the location of the microinverter on the roof, or you can draw an installation map yourself. -
There are two sheets of serial numbers affixed to each microinverter case. One of the sheets can be peeled off. Remove the removable serial number label from each microinverter and attach the serial number label to the appropriate location on the installation map.
(Installation map templates can be obtained from User Manual 7.2 Installation Maps.) -
When the installation map is completed, you can upload it during the construction of the station after logging into the SOFAR Monitor APP. In the APP you can get graphical solar system operation information and can monitor and analyze system information in real time.
-
Step 8: Commissioning
-
Cable connection check ATTENTION
Before starting up the device for the first time (commissioning), all operations performed on the device should be thoroughly checked. In particular, check that the DC terminal voltage and the AC terminal voltage comply with the permissible range of the microinverter. -
Start the inverter
-
Close each microinverter branch AC circuit breaker.
-
The main grid-connected circuit breaker is closed and the system generates power in approximately 3 minutes (the specific start time is required by national/regional regulations).
-
Please pay attention to the indicator light display on the side of the inverter. When the microinverter is connected to the PV modules, if the indicator green light is always on, the microinverter is working normally at this time.
Open the APP to check the working status of the microinverter. -
Step 9: Connecting the monitoring system
Please refer to “SOFAR Monitor User Manual” to set up the monitoring system.
(You can download SOFAR Monitor APP by scanning the QR code below, and check
it in the “My – Personal Settings – About Software – Operation Manual” page of
SOFAR Monitor APP.)
07 MR600, MR800, MR1000
References