Inter-Tech Sama XPH-850A 850W ATX Instruction Manual
- August 17, 2024
- Support
Table of Contents
Inter-Tech Sama XPH-850A 850W ATX
Introduction
Thank you for buying an SAMA power supply. You chose a high-quality and high- efficient power supply which is made from selected components and subjected to a strict quality management system. This ensures best performance and reliability.
The power supply has a high efficiency which respects the environmental and lowers the cost of power.
This is documented by the 80+ Platinum certification of the independent website Plug Load Solutions made by CLEAResult, the biggest North American provider of energy efficiency programs and services.
The high 12V output with up to four PCI Express connectors as well as the newest Intel ATX 12V 3.0 standard with a 12VHPWR 600W PCIe 5.0 output ensure a future-proof system.
We recommend to read this manual carefully and especially paying attention for the security advices to enjoy this power supply for a long time.
Signs and symbols
Symbols | Meaning |
---|---|
Handling and effects of safety instructions. | |
Allusion to dangerous situation which can cause injury or death if not |
prohibited.
| Allusion to dangerous situation which can cause fire.
| Allusion to property damages and general information.
Safety
Intended use
This device is made only for indoor use and for mounting in computer cases.
Don´t use and store the device inside humid rooms or near water.
Don´t use it close to source of heat. The additional heat could lead to
overheating and fire.
General information
Please read this manual carefully before installing or using this product.
Keep this manual and pass it by passing the product.
Please follow the instructions and warnings of this manual before using the
product.
The inobservance of this manual can cause violations and damages.
We disclaim liability for violations and damages caused by inobservance of
this manual.
Danger and protection
Don´t stick any items into the power supply (electric strike).
Don´t pull the plug by pulling at the cable.
Don´t use any patched or damaged cable or plug.
Don´t place the device close to source of heat.
In case of strange noise or smell pull the power cord out of the socket.
Don´t open the housing of the device (fire hazard/ electric strike).
Ensure that all cables are fixed permanently.
Keep the product away from children.
Don´t remove the cable with wet hands (electric strike).
Don´t use the product with wet hands (electric strike).
Please remove the power cord from socket in case of longer non-use (Could led
to overheating, fire hazard or electric strike).
Keep the product free of dust (Overheating or fire).
Look for sufficient airflow and ventilation to avoid overheating or fire.
Leave service or cleaning only authorized and qualified personnel.
Technical data
General data
Standard | Intel ATX 12V 3.0 |
---|---|
Input voltage | 100 – 240 V~ AC, 50-60Hz |
Input current | XPH850A 115V – 10A / 230V – 8A XPH1000A 115V – 15A / 230V – 8A |
XPH1200A 115V – 15A / 230V – 8A
PFC| Active
Power factor| > 0,90
Stand-by| XPH850A 0,42W XPH1000A 0,41W XPH1200A 0,44W
MTBF| 100,000h at 25°C
Environmental| Operation| 0 – 40°C/ -85% not condensing
Storage| -20 – 90°C/-95% not condensing
Output
Max. | Total | 3,3V | 5V | Combined | 12V | -12V | 5Vsb |
---|---|---|---|---|---|---|---|
XPH850A | 850W | 20A | 20A | 100W | 70.8A | 0.4A | 3A |
XPH1000A | 1000W | 20A | 20A | 100W | 83.3A | 0.4A | 3A |
XPH1200A | 1200W | 20A | 20A | 100W | 100A | 0.4A | 3A |
Safety
OPP Over-Power-Protection| Power supply will shut down if the output is more
than 130% of the nominal output.
---|---
OCP Over-Current-Protection| Power supply will shut down if the current of the
output lines will exceed the tolerance value.
OVP Over-Voltage-Protection| To prevent further damages the power supply will
shut down if a fault causes a higher output voltage.
SCP Short-Circuit-Protection| Power supply will shut down in case of a short
circuit on secondary output lines.
NLP No-Load-Protection| Power supply will shut down in case of no load on
secondary output lines to prevent damages.
Efficiency 230V~
Load | 20% | 50% | 100% | |
---|---|---|---|---|
XPH850A | 850W | 92,70 % | 93,60 % | 91,90 % |
XPH1000A | 1000W | 92,70 % | 93,70 % | 92,20 % |
XPH1200A | 1200W | 92,90 % | 93,90 % | 92,00 % |
Efficiency 115V~
Load | 10% | 20% | 50% | 100% | |
---|---|---|---|---|---|
XPH850A | 850W | 88,72% | 91,66 % | 93,22 % | 92,04 % |
XPH1000A | 1000W | 89,21 % | 92,26 % | 93,15 % | 91,35 % |
XPH1200A | 1200W | 90,14 % | 92,76 % | 93,12 % | 90,20 % |
Connectors
All connectors are standardized and made against reverse connection.
In case of difficulties during connection, please make sure to use the right connector or rotate the connector by 180°.
Don´t try to insert a connector forcibly.
Quantity
| ATX 20+4pin| EPS/ P4 4+4pin| IDE 4pin| SATA 15pin| 12HPWR 12+4pin| PCIe
6+2pin
---|---|---|---|---|---|---
XPH850A| 1| 2| 4| 8| 1| 3
XPH1000A| 1| 2| 4| 8| 1| 3
XPH1200A| 1| 2| 4| 8| 1| 3
Pin configuration
P1 ATX-Mainboard connector 20+4 pin
Pins 11/ 12/ 23/ 24 are made as separate jacks.
It can be swung away in case of using older Mainboards.
Don´t mix the separate jack with the P4 connector.
EPS/ P4 Mainboard connector 4+4 pin
Depending your mainboard you need an 8pin or 4 pin connector. For that the
connector is divisible.
In case of using just the 4pin connector the rest of the connector is without
function.
Don´t plug it into another socket on the board.
IDE connector 4 pin
Signal | Pin |
---|---|
+12V DC | 1 |
COM | 2 |
COM | 3 |
+5V DC | 4 |
FDD connector 4 pin
Signal | Pin | Signal |
---|---|---|
+5V DC | 1 | +12V DC |
COM | 2 | +12V DC |
COM | 3 | +12V DC |
+12V DC | 4 | +12V DC |
PCI-Express connector 6+2 pin
Some graphic adapter need only a 6pin plug for connection. In this case, pull off the 2pin connector from the PCIe connector.
SATA connector 15 pin
Signal | Pin # |
---|---|
+3.3VDC | 1 |
+3.3VDC | 2 |
+3.3VDC | 3 |
Masse | 4 |
Masse | 5 |
Masse | 6 |
+5VDC | 7 |
+5VDC | 8 |
+5VDC | 9 |
Masse | 10 |
Masse | 11 |
Masse | 12 |
+12VDC | 13 |
+12VDC | 14 |
+12VDC | 15 |
12 VHPWR connector 12+4 pin
Signal | Pin | Signal | Pin | Signal | Pin |
---|---|---|---|---|---|
CARD_PWR_Stable | S1 | +12V | 1 | GRD | 7 |
CARD_CBL_PRES# | S2 | +12V | 2 | GRD | 8 |
SENSE0 | S3 | +12V | 3 | GRD | 9 |
– | S4 | +12V | 4 | GRD | 10 |
+12V | 5 | GRD | 11 | ||
+12V | 6 | GRD | 12 |
Please note: This connector is made up to 600W output only!
To avoid possible fire make sure that the jack is completely pluged into the
socket.
Assembling and initial operation
-
Take out the power supply and check the package content for completeness or damages.
Please contact your local dealer for replacement in case of missing or damaged parts.
Please keep the original package for shipping in case of warranty claim.
Please connect the power supply to the grid after connecting all other devices. Fix the power supply with the enclosed screws to the allocated space of the computer case. -
Connect all components with the suitable cables.
Please follow also chapter 5.2 (Pin configuration) as well as the instructions of the device manufacturers.
A faulty connection of the components can cause damages. Please ask your local dealer or our service-hotline in case of discrepancies or questions. -
Lay all cables in a way to avoid disturbing airflow or any rotating fan. Use the enclosed cable ties to fix the cables.
-
Connect the power supply with the electric socket.
Use only the original power cord. In case of a damaged cable, please change it against an approved power cord from your local dealer. -
Switch on the power supply at the backside of the power supply. Your computer is ready now
When power-on the power supply it is in a Stand-By mode to start the computer by pressing the power button at the case front. To separate the computer totally from the electric grid power –off the power supply directly.
Fan Control
The power supplies of the SAMA XP-series are provided with an intelligent fan control (IFC) which regulates the fan temperature depended. It rotates between 0 and 1600 rpm automatically.
This keeps the noise level of the fan very low.
FAQ
Error | Possible reason(s) | Help |
---|---|---|
The power supply runs shortly and stops. | Short circuit at Mainboard, HDD, FDD | |
or CD-ROM | Check all connectors for right connection. | |
Eliminate short circuit or change components. | ||
Power supply does not start | Secondary connectors not connected | Check all |
connectors for right connection.
| Main switch on power supply is off| Switch on the main switch of the power
supply.
Power cord is not connected| Check if power cord is connected to power supply
and electric grid.
Power cord defective |
Change power cord against an approved new power cord.
Power socket defective | Let authorized experts check the socket.
Please unplug power cord generally when working inside the computer case.
In case of checking the electric socket exists risk of electric strike.
Leave work on mains supply only authorized experts.
Maintenance
The power supply needs no maintenance which requires opening of the housing or working inside the power supply.
But cause of the intake of air, dust can collect inside the power supply. This can lead to overheating or fire.
You can remove this dust with compressed air by yourself. To do this, unplug the power supply from mains supply, dismount the power supply in reversed way as described before and blow the dust with compressed air through the fan grid out of the housing.
Do not use a wet or moist rag to remove dust. Hazard of electric shock.
Do not open the power supply in any circumstances. You will risk your life by an electric shock, destroy any components and lose your warranty claim.
We recommend to let authorized experts do the cleaning.
Disposal
Please dispose this device by using the special discharge point for electronic
waste and ask your municipality or disposal company in case of further
questions.
Please dispose the cardboard and plastics by using the appropriate containers
of the household garbage.
Warranty terms
In spite of best efforts and quality controls a device can have a fault. But because the SAMA XP-series is made by highest quality standard we extend the legal warranty terms to totally 3 years up from purchase date at proper use. In case of a warranty claim please contact your dealer from whom you bought the product.
We will grant no warranty by:
- Missing or damaged warranty seal,
- Negligent behavior,
- Improper use,
- Nonobservance of the manual,
- External violence,
- Acts of god,
- Damages caused by manipulation, upgrading, updating or reconstruction of hardware or software
- Damages caused by other harm,
In case of data loss Inter-Tech will only be liable at wanton negligence or deliberate intention or, in all other cases, only for the recovery of data from a continuous, daily backup. Inter-Tech does not assume liability for all other matters.
Please look also at our complete warranty terms on our website.
CUSTOMER SUPPORT
Inter-Tech Elektronik Handels GmbH –
Weg 93 – D-30855 Langenhagen – vertrieb@inter-tech.de
www.inter-tech.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>