Kenmore 997.151230 3.5 Gallon Warm Mist Humidifier Owner’s Manual
- August 13, 2024
- Kenmore
Table of Contents
- Kenmore 997.151230 3.5 Gallon Warm Mist Humidifier
- Product Usage Instructions
- FAQ
- TECHNICAL SPECIFICATIONS
- GENERAL SAFETY INSTRUCTIONS
- GETTING TO KNOW YOUR HUMIDIFIER
- INTRODUCTION
- PRE-OPERATING INSTRUCTIONS
- OPERATION
- CLEANING THE ABSORPTION SLEEVE
- REPLACEMENT PARTS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Kenmore 997.151230 3.5 Gallon Warm Mist Humidifier
Product Usage Instructions
- Save these important instructions for future reference.
- Congratulations on your purchase of your new Kenmore Warm Mist Humidifier with an exclusive Warm Wicking Vapor System.
- You have purchased the newest and most advanced technology available in warm mist humidifiers.
- This patented technology creates an extremely quiet, low-maintenance humidifier.
FAQ
- What should I do if my Kenmore humidifier is missing parts?
- If you are missing parts on your Kenmore humidifier, call the INFO-LINE at 1-888-838-0807 for assistance.
- Can I repair the humidifier myself if it experiences issues?
- No, the humidifier is not serviceable by customers. Do not attempt to repair it yourself as it may void the warranty and cause damage or personal injury. Consult the operations manual and contact customer service for help.
CAUTION
Read and follow all Safety Rules and Operating Instructions before the first
use of this Product.
INFO-LINE
After having read this manual, if you have any questions or are missing parts
on your Kenmore humidifier, call:
1-888-838-0807
FULL ONE-YEAR WARRANTY
For one year from the date of purchase, if this Kenmore Humidifier fails due
to defects in material or workmanship, return it to your nearest Sears store
and it will be replaced free of charge.
This warranty DOES NOT cover the absorption sleeve, which is an expendable
part.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
- Sears, Roebuck and Co., Dept. 817WA
- Hoffman Estates, IL 60179 U.S.A.
- Sears Canada, 222 Jarvis Street
- Toronto, Ontario, Canada M5B2B8
CUSTOMER SERVICE
- This humidifier is not serviceable. DO NOT attempt to repair this humidifier yourself. Doing so may void your warranty, cause damage to the humidifier or cause personal injury.
- If you should experience any problems with this humidifier, please consult this operations manual and your warranty information. If you have any questions concerning this humidifier, please call toll-free:
- 1-888-838-0807
- CUSTOMER SERVICE OPERATION HOURS
- Monday – Friday 8:00 am – 5:00 pm (cs-r)
TECHNICAL SPECIFICATIONS
Model No. 997.151230 997.151250
- Input Voltage (VAC/60 Hz) ………………………. 120 ………………. 120
- Power Consumption (watts) ……………………. 300 ………………. 520
- Current (amps) ……………………………………… 3.1 ……………….. 5.0
- Tank Capacity (gallons) each …………………… 1.7 ……………….. 1.7
- Output for 24 hours (gallons) …………………… 2.0 ………………. 3.5
MODEL NO. 997.151230 (2.0 Gallon)
MODEL NO. 997.151250 (3.5 Gallon)
The model number may be found on the humidifier identification label. Always
mention the model number when requesting replacement parts.
SHIPPING CARTON
Be sure to save the shipping carton to store the humidifier when it is not in
use.
GENERAL SAFETY INSTRUCTIONS
- As with all electrical appliances, be sure to follow basic safety procedures to minimize the risk of injury.
- To avoid electrical shock or fire, be sure to plug into a 120v AC outlet only. Make sure the plug is fully inserted.
- The power cord has a polarized AC plug, which will fit into the outlet one way only (one blade is wider than the other). If the plug will not insert fully with the outlet you are using, try reversing the plug. If the plug still fails to fit, call an electrician to replace the older outlet. Never alter the plug to fit into an obsolete outlet. Doing so may compromise safety.
- Use this product indoors only.
- Do not use an extension cord.
- Do not place power cords under carpeting, rugs, or runners. Arrange the power cord as not to be a tripping hazard.
- Do not use this product if parts are missing. Do not use this appliance if the power cord shows signs of damage, or if the appliance has been dropped or misused.
- Use this appliance on a flat, level surface only. This appliance may not function properly if placed on an uneven surface.
- Place this humidifier on a water-resistant surface.
- Be sure to unplug the appliance when not in use, while cleaning, or replacing the absorption sleeve.
- Never tip or move this appliance while operating it, or while water is in the base or tank(s).
- Do not place this appliance near furnaces, heaters, stoves, or any other source of heat.
- Position this appliance out of the reach of children.
- Do not attempt to use this humidifier without the absorption sleeve.
- Be sure the humidifier’s heating element has cooled down sufficiently before moving, cleaning, or replacing the absorption sleeve.
- This appliance requires periodic maintenance, including cleaning or replacement of the absorption sleeve.
- Refer to those instructions in this manual.
- Do not use anything other than water in this appliance.
- Do not use additives.
- Turn off the humidifier if relative humidity exceeds 60%.
- Never block the mist outlet.
Save these important instructions for future reference.
GETTING TO KNOW YOUR HUMIDIFIER
Model No. 997.151230 (2.0 Gallon)
- Tank
- Cap
- Base
- Mist Chamber
- Power Control Knob
- Humidistat Control Knob
- Medicine Cup
- Tank Carry Handle (top)
- Tank Carry Handle (bottom)
- Safety Switch
- Locking Device
- Grill
Model No. 997.151250 (3.5 Gallon)
INTRODUCTION
- Congratulations on your purchase of your new Kenmore Warm Mist Humidifier with exclusive Warm Wicking Vapor System’.
- You have purchased the newest and most advanced technology available in warm mist humidifiers. This patented technology creates an extremely quiet, low-maintenance humidifier.
WHAT IS WARM WALKING VAPOR SYSTEM’?
Warm Wicking Vapor System” is a new, revolutionary, patented technology that eliminates annoying problems associated with other warm mist humidifiers. An absorption sleeve placed on the heating element traps dirt and unwanted minerals, preventing buildup on the heating element and near the steam outlet. The sleeve also works to eliminate annoying bubbling and gurgling sounds created by other warm mist humidifiers.
- No dangerous mineral buildup on the heating element!
- No unsightly mineral buildup near the steam outlet!
- No noisy gurgling sounds to keep you awake at night!
- No need to perform tedious cleaning of the heating element!
ADVANTAGES OF MAINTAINING PROPER MOISTURE LEVELS
Dry indoor air can be uncomfortable and damaging to people, pets, plants, and belongings. Proper moisture levels can help alleviate or prevent:
- Stuffy, dry nasal passages
- Dry coughs and irritated throats
- Parched lips and itchy, flaky skin
- Dry, cracking wood furniture
- Dry plants, flowers
- Static electricity
- Dry coats and minimizes shedding for pets
IMPORTANT! It is recommended that you remove and inspect your absorption sleeve every time you refill your tank(s). Clean or replace your sleeve if you notice any mineral buildup or discoloration on the outside or inside of your absorption sleeve. Failure to properly maintain your absorption sleeve can result in poor performance and possible malfunction of your humidifier. For best results use distilled or filtered water.
HOW YOUR HUMIDIFIER WORKS
Water flows from the tank(s) into the humidifier base. The water is then
absorbed up the absorption sleeve where it is heated, purified and converted
into warm mist. The warm mist then rises up through the mist chamber,
dispensing comfortable, soothing, invisible moisture into the air. During this
process, unwanted minerals are trapped within the absorption sleeve material.
PRE-OPERATING INSTRUCTIONS
Locate an appropriate, level, flat surface near an electrical outlet for placement of your humidifier. Be sure to place your humidifier on a water- resistant surface, since water can cause damage to furniture. Position the humidifier so the power cord does not become a tripping hazard. To ensure proper ventilation, be sure to keep the humidifier at least 6 inches from a wall or any other object.
- Remove the tank(s) from the base by grasping top handle.
- Rotate the mist chamber locking device to unlock the mist chamber (see illustration above). Lift the mist chamber off the base. Locate the absorption sleeve attached to the heating element on the underside of mist chamber. Be sure the sleeve is tightly attached to the heating element. Loosely attached absorption sleeves may produce less humidity and cause malfunctions.
- CAUTION- Never attempt to use this humidifier without the absorption sleeve.
- Refer to pages 8-9 for proper absorption sleeve attachment.
- Replace the mist chamber. Turn the locking device to secure the mist chamber to the base. Replace tank(s).
SET-UP
Remove the tank(s), turn the tank(s) upside down, and remove the fill cap by
turning counterclockwise.
Fill the tank(s) with cool water, for best results use distilled or filtered
water. Do not use hot water or any chemical additives. Replace the fill cap by
turning clockwise, be sure not to overtighten. Turn the tank(s) upright and
position the tank(s) back onto the humidifier base. Be sure the tank(s) is
seated properly on the base. Water will begin to flow from the tank(s) into
the base.
- NOTE: Approximately 3/4 down the right side of the mist chamber is a SAFETY SWITCH. When the tank (the right tank only on the 3.5-gallon model) is removed, it releases the SAFETY SWITCH and the humidifier stops producing moisture. When this occurs, the
- REFILL light .will illuminate. The humidifier will not operate without the tank properly seated on the base.
- Be sure, when putting the tank back on the base, that it is set properly and that the tank is putting pressure on the SAFETY SWITCH to start the humidifier.
- Never attempt to move the humidifier with water in the tank(s).
- If moving the humidifier is necessary, be sure to unplug the humidifier and remove the tank(s).
- WARNING: Never pour water into the mist chamber grill.
- Doing so may cause personal injury and damage to the humidifier.
- The humidifier will not operate when the water in the base reaches a minimum level. When this occurs, the REFILL light will illuminate.
OPERATION
- With the Power Control Knob in the OFF position, plug the power cord into a polarized 120v outlet.
- REMEMBER: Do not force the polarized plug into the outlet; it will fit one way only.
IMPORTANT! It is recommended that you remove and inspect your absorption sleeve every time you refill your tank(s). Clean or replace your sleeve if you notice any mineral buildup or discoloration on the outside or inside of your absorption sleeve. Failure to properly maintain your absorption sleeve can result in poor performance and possible malfunction of your humidifier. For best results use distilled or filtered water.
WARNING: Do not attempt to plug the humidifier in with wet hands, as an electrical shock may occur.
- Turn the Humidistat Control Knob to the MAX position (far right). Turn the Power Control Knob to the desired position:
- HIGH for fast humidification or LOW for more gradual humidification. When the power is ON, the POWER light will illuminate.
- Comforting, invisible warm mist will begin in 2-4 minutes.
NOTE: If the humidifier does not produce moisture, the humidistat may be positioned too low. Moving the Humidistat Control Knob to a higher position (farther right) should start the humidifier. Do not force the Humidistat Control Knob beyond the MAX position. Doing so will cause damage to the humidifier.
- When the humidity in the immediate area reaches the setting on the Humidistat Control Knob, the HUMIDITY light will illuminate and the humidifier will stop producing moisture.
- When the humidity in the immediate area drops below the Humidistat Control Knob setting, the humidifier will automatically start producing moisture again and the HUMIDITY light will not be illuminated. This ON/OFF cycle will continue while the humidifier is in use.
- If condensation begins to form on walls or windows, lower the Humidistat Control Knob setting (turn knob to the left).
- When you are finished using the humidifier, be sure to turn the Power Control Knob to the OFF position.
REFILLING THE TANK(S)
- When the water reaches a minimum level in the base, the
- REFILL light will illuminate and the humidifier will automatically stop producing moisture.
- Fill the tanks with cool water, for best results, use distilled or filtered water. Do not use hot water or chemical additives.
- If the humidifier is already in the ON position, the humidifier will automatically start producing a warm mist in 2-4 minutes.
- NOTE: Approximately 3/4 down the right side of the mist chamber is a SAFETY SWITCH. When the tank (right tank only on 3.5 gallon model) is removed, it releases the SAFETY SWITCH and the humidifier stops producing moisture. When this occurs, the
- REFILL light will illuminate. The humidifier will not operate without the tank properly seated in the base. Be sure, when putting the tank back in the base, that it is set properly and that the tank is putting pressure on the SAFETY SWITCH to engage power and start the humidifier.
NOTE: Depending on how level and flat the surface is where you placed your humidifier, models with two tanks may empty into the base together or separately.
REPLACING THE ABSORPTION SLEEVE
- It is recommended that you remove and inspect your absorption sleeve every time you refill your tank(s). Clean or replace your sleeve if you notice any mineral buildup or discoloration on the outside or inside of your absorption sleeve. Failure to properly maintain your absorption sleeve can result in poor performance and possible malfunction of your humidifier. For best results, use distilled or filtered water.
- The absorption sleeve is a vital part of your humidifier. Do not attempt to use your humidifier without this sleeve. Do not alter or attempt to repair any absorption sleeve. Be sure to use only Kenmore absorption sleeves with your humidifier. Using anything other than Kenmore absorption sleeves may cause damage to the humidifier, create a safety hazard, and void the warranty.
- CAUTION: Be sure the humidifier has cooled sufficiently before handling the humidifier.
- Remove the tank(s) from the base. Rotate the mist chamber locking device to unlock the mist chamber. Lift the mist chamber off the base. Remove the absorption sleeve from the heating element, found on the underside of the mist chamber.
- With a soft cloth or soft toothbrush, wipe away any buildup from the heating element.
IMPORTANT! It is recommended that you remove and inspect your absorption sleeve every time you refill your tank(s). Clean or replace your sleeve if you notice any mineral buildup or discoloration on the outside or inside of your absorption sleeve. Failure to properly maintain your absorption sleeve can result in poor performance and possible malfunction of your humidifier. For best results use distilled or filtered water.
Attach a new or cleaned absorption sleeve to the heating element. Pull the
sleeve tightly around the heating element and secure it with the attached
Velcro® fastener. See the illustrations below.
NOTE: It is important to be sure the sleeve is very tight around the
heating element for best performance.
- Absorption Sleeve 3-Pack Item No. 15110 can be found at your local Sears store.
CLEANING THE ABSORPTION SLEEVE
- Hand wash the absorption sleeve using running tap water, while gently rubbing the inside and outside of the sleeve with your fingers. Do not put the absorption sleeve in the washer or dishwasher.
- Inspect the absorption sleeve for signs of wear. Do not use it if the sleeve is torn, tattered, or has holes.
- NOTE: Washed absorption sleeves may build up minerals more quickly and may experience deterioration of the sleeve material. Washed absorption sleeves will need more frequent cleaning.
CLEANING THE HUMIDIFIER
It is strongly recommended that you clean your humidifier at least once a
week, or more frequently if you:
- Have hard water.
- Notice a buildup of impurities.
- Notice an unpleasant odor.
Always turn off and unplug the humidifier before cleaning.
Be sure to wait until the heating element has cooled sufficiently.
Periodically wipe down the outside of the humidifier with a damp, soft cloth. Do not use harsh, abrasive cleaners on this humidifier. Never submerse the mist chamber in liquid or pour liquid in or on the mist chamber. Doing so may damage the unit and may cause injuries.
CLEANING THE TANK(S)
Put 1/2 teaspoon of chlorine bleach and 1/2 gallon of water in the tank. Let
solution stand for 20 minutes swishing every few minutes, Empty tank(s) and
rinse well with water until the bleach smell is gone.
CLEANING THE BASE
Mineral deposits will accumulate in the base of the humidifier from time to
time. When this occurs, the base should be cleaned. Remove the tank(s) and
mist chamber. The base can be put in the dishwasher or cleaned with a damp,
soft cloth.
CAUTION: Only the base is dishwasher safe. Do not attempt to put the
tank, mist chamber or absorption sleeve in the dishwasher. Doing so may damage
the humidifier and create a safety hazard.
END OF SEASON CARE AND STORAGE
- Empty the tank and base of all water.
- Clean all surfaces with a damp, soft cloth.
- Clean the base by putting it in the dishwasher or wiping it with a damp, soft cloth.
- Remove the absorption sleeve and replace it with a dry sleeve.
- NOTE: Before storing your humidifier for the season, or for any extended time, be sure the absorption sleeve is completely dry to help prevent mold and mildew. Air dry only. Do not put in the dryer.
- Store the unit in its original carton, in a cool dry location.
- Remember to clean and inspect your humidifier before using it the next season.
IMPORTANT! It is recommended that you remove and inspect your absorption sleeve every time you refill your tank(s). Clean or replace your sleeve if you notice any mineral buildup or discoloration on the outside or inside of your absorption sleeve. Failure to properly maintain your absorption sleeve can result in poor performance and possible malfunction of your humidifier. For best results use distilled or filtered water.
REPLACEMENT PARTS
Model No. 997.151230 (2.0 Gallon)
Parts Description Part No.
- Tank (with cap) …………………………………………… 997.15001
- Cap …………………………………………………………… 997.15002
- Base …………………………………………………………. 997.15003
- Mist Chamber ……………………………………………. 997.15004
- Absorption Sleeve ………………………………………. 997.15005
HOW TO ORDER REPLACEMENT PARTS
To order replacement parts by telephone, please call toll-free:
1-800-4-MY-HOME ® (469-4663)
When ordering replacement parts, always give the following information:
- Part Number (See Replacement Parts List)
- Part Description (See Replacement Parts List)
- Kenmore Humidifier Model Number (997.151230)
- Name of item (Kenmore 2.0 Gallon Warm Mist Humidifier)
Customer Service at 1-888-838-0807
REPLACEMENT PARTS
Model No. 997.151250 (3.5 Gallon)
Parts Description Part No.
- Tank (with cap) …………………………………………… 997.15001
- Cap …………………………………………………………… 997.15002
- Base …………………………………………………………. 997.15006
- Mist Chamber ……………………………………………. 997.15008
- Absorption Sleeve ………………………………………. 997.15005
HOW TO ORDER REPLACEMENT PARTS
To order replacement parts by telephone, please call toll-free: 1-800-4-MY-
HOME ® (469-4663)
When ordering replacement parts, always give the following information:
- Part Number (See Replacement Parts List)
- Part Description (See Replacement Parts List)
- Kenmore Humidifier Model Number (997.151250)
- Name of item (Kenmore 3.5 Gallon Warm Mist Humidifier)
Customer Service at 1-888-838-0807
HELP PAGE
The power light is not illuminated.
- Be sure Power Control Knob is in the HIGH or LOW position.
- Be sure the humidifier is plugged into the outlet.
- Check the outlet or circuit breaker.
Humidity light is illuminated.
- The Humidity light illuminates when the humidity in the room matches the setting of the Humidistat Control Knob.
- If the humidity in the room should drop below the Humidistat Control Knob setting, the Humidity light will shut off and the humidifier will start producing a warm mist again.
Mist output is minimal or none
- Be sure Power Control Knob is in the HIGH or LOW position.
- Be sure the humidifier is plugged into the outlet.
- Check the absorption sleeve for mineral buildup. ( REPLACING THE ABSORPTION SLEEVE CLEANING THE ABSORPTION SLEEVE).
The refill light is illuminated with water in the tank(s).
- If the tanks have water and the Refill light illuminates, check to see if the tank is properly seated on the base (right tank on 3.5 gallon model) and engage the Safety Switch located on the right side of the mist chamber (see page 6; SET-UP NOTE).
Cloudy film on tank(s) surfaces.
- CLEANING THE TANK(S).
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Kenmore Humidifier Parts - Select From 496 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>