LEDSION 2FWP80W-120V-50K Watts Select Full CutOff LED WallPack User Guide
- August 11, 2024
- LEDSION
Table of Contents
Watts Select Full CutOff LED WallPack
Date: Location:
Product: Project:
Quantity: Catalog#
FEATURES
- Built in Watts Selector and photocell options
- Architecture design, Easy installation.
- Wet location rated IP65.
- Durable die-cast aluminum housing.
- Photocell and motion sensor options.
- UV-resistant polycarbonate refractor lens.
- Emergency power 4W & operating time 1.5 hours.
- TypeII / TypeIII / TypeIV distribution optics standard
SUITABLE APPLICATIONS
- Warehouses
- Factories
- Shopping Malls
- Supermarkets
- Logistic Centers
CONSTRUCTION:
Heavy die-cast aluminum alloy housing with bronze powder – coated finish. High
light transmittance PC lens.
OPTICAL SYSTEM:
High brightness Lumileds 3030LED chips. Full Cutoff illumination
WARRANTY:
5- year limited warranty. Actual performance may differ as a result of end-
user environment and application.
ELECTRICAL:
Available as 120-347V input. -30°C to 45°C
INSTALLATION & MOUNTING:
Wall Mounting with install accessories for easy installation.
CONTROLS & DIMMING
0-10V dimming comes standard. Photocell is included
PERFORMANCE
Sku model no
| Adjustable power| Emergency Duration| Voltage/Current Input|
Microwave Motion Sensor Effective| Kelvin Options
---|---|---|---|---|---
120V
| 277V|
347V
2FWP80W-120V-50K| 20W| 1.5H| 0.16A| 0.07A| 0.05A| 40FT|
3000K/4000K/5000K
40W
| 1.5H| 0.33A| 0.14A| 0.11A| 40FT| 3000K/4000K/5000K
60W| 1.5H| 0.50A| 0.21A| 0.17A| 40FT|
3000K/4000K/5000K
80W
| 1.5H| 0.62A| 0.28A| 0.23A| 40FT| 3000K/4000K/5000K
2FWP100W-120V-50K| 60W| 1.5H| 0.50A| 0.21A| 0.17A| 40FT|
3000K/4000K/5000K
80W
| 1.5H| 0.62A| 0.28A| 0.23A| 40FT| 3000K/4000K/5000K
100W| 1.5H| 0.83 A| 0.36A| 0.28A| 40FT|
3000K/4000K/5000K
120W
| 1.5H| 0.83 A| 0.36A| 0.28A| 40FT|
3000K/4000K/5000K
LIGHTING
Features
- Integrated Photocell
- Plug-in Haisen Photocell
PRODUCT ORDERING GUIDE
2 Generation II
FWP Full Cut-Off Wall Pack
30W Power30W 40W Power40W
60W Power60W 80W Power80W
100W Power100W 120W Power120W
30K CCT:3000K 40K CCT:4000K
50K CCT:5000K
Electric Characteristic
Adjustable power
| 2FWP80W-120V-50K
---|---
LED Driver|
UL listed WELEDPOWER Brand 0-10V dimmable
Input power
| 20W| 40W| 60W| 80W
Lumens output| 3600LM| 5200LM| 6500LM|
10400LM
Efficiency
| 130LM/W| 130LM/W| 130LM/W| 130LM/W
CRI| >72| >72| >72|
72
Color Temperature
| 5000K| 5000K| 5000K| 5000K
Input voltage| 120-347V/AC| 120-347V/AC| 120-347V/AC|
120-347V/AC
Light distribution type
| Type II III IV| Type II III IV| Type II III IV| Type II III IV
Working temperature| -30+45℃| -30+45℃| -30+45℃|
-30+45℃
Junction temperature
| <75℃| <75℃| <75℃| <75℃
lamps efficiency| ≥90%| ≥90%| ≥90%|
≥90%
Certificate
| UL CUL DLC| UL CUL DLC| UL CUL DLC| UL CUL DLC
Equivalent| 60-90W MH/HPS| 90- 120W MH/HPS| 120-150W MH/HPS|
180-240W MH/HPS
Adjustable power
| 2FWP100W-120V-50K
---|---
LED Driver|
UL listed WELEDPOWER Brand 0-10V dimmable
Input power
| 60W| 80W| 100W| 120W
Lumens output| 7800LM| 10400LM| 13000LM|
15600LM
Efficiency
| 130LM/W| 130LM/W| 130LM/W| 130LM/W
CRI| >72| >72| >72|
72
Color Temperature
| 5000K| 5000K| 5000K| 5000K
Input voltage| 120-347V/AC| 120-347V/AC| 120-347V/AC|
120-347V/AC
Light distribution type
| Type II III IV| Type II III IV| Type II III IV| Type II III IV
Working temperature| -30+45℃| -30+45℃| -30+45℃|
-30+45℃
Junction temperature
| <75℃| <75℃| <75℃| <75℃
lamps efficiency| ≥90%| ≥90%| ≥90%|
≥90%
Certificate
| UL CUL DLC| UL CUL DLC| UL CUL DLC| UL CUL DLC
Equivalent| 150-180W MH/HPS| 180-240W MH/HPS| 240-320W MH/HPS|
320-400W MH/HPS
DIMENSION
30-60W(120-277VAC&120-347VAC)/80W(120-277V AC)
80W(120-347VAC)/100-120W(120-277V AC&120-347VAC)
DISTRIBUTION DIAGRAM
30W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 30W C0/180,143
Lumens:3900LM C30/210,102.3
Test Number:30W C60/240,109.8
Test Number:5000K C90/270,50
40W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 40W C0/180,143
Lumens:5200LM C30/210,102.3
Test Number:40W C60/240,109.8
Test Number:5000K C90/270,50
60W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 60W C0/180,143
Lumens:7800LM C30/210,102.3
Test Number:60W C60/240,109.8
Test Number:5000K C90/270,50
80W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 80W C0/180,143
Lumens:10400LM C30/210,102.3
Test Number:80W C60/240,109.8
Test Number:5000K C90/270,50
100W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 100W C0/180,143
Lumens:13000LM C30/210,102.3
Test Number:100W C60/240,109.8
Test Number:5000K C90/270,50
120W
AVERAGE BEAM ANGLE(50%): 92°
UNIT:CD
Test Number:LS- FWPV2- 120W C0/180,143
Lumens:15600LM C30/210,102.3
Test Number:120W C60/240,109.8
Test Number:5000K C90/270,50
INSTALLATION:
-
Unscrew door with Philips screwdriver by loosening (2) screws. Confirm junction box size and junction box mounting provisions to that of the light fixture.
-
Attach the light fixture to the junction box or mounting surface.
-
Attach the appropriate wires to the light fixture wires, green to green, black to black and white to white. Secure each wire pair with a wire nut (Wiring instruction FYI.)
-
Close the door and tighten(2) screws on the door lens. Nothing should
-
(2) screws
-
HOUSE
-
DOOR LENS
MAINTENANCE CAUTION:
- Review the diagrams before beginning, and make sure the fixture is grounded properly.
- Turn the power off and wait for fixture cooling to operate.
- This fixture has to be installed or maintenance in accordance with the application code by a professional person who familiar with the construction and operation of the product and the hazards involved. construction and operation of the product and the hazards involved.
WARRANTY:
5- YEAR WARRANTY.
If this product fail to perform satisfactorily due to defect or poor
workmanship within five years from the date of purchase, return it to the
place of purchase and it will be replaced, free of charge. Incidental or
consequential damages are excluded from the warranty.
DIMENSIONAL DRAWING:
30-80W
100-120W
SAFETY INSTRUCTION:
- This fixture must be wired in accordance with the international electrical code and applicable local codes and ordinances.
- Proper grounding is required to insure personal safety. Carefully observe the correct grounding procedure under installation section.
- Make sure power off before installing or maintaining fixture.
- Check that voltage is compatible with fixture driver, use approved connectors for all electrical connections.
CLEANING:
- Before touching fixture, make sure the fixture is cooling.
- Do not clean or maintain while fixture is energized.
- Clean lens & fixture with non- abrasive glass cleaning solution.
- Do not open fixture to clean and touch LED chips.
WIRING INSTRUCTION:
WARNING: TURN OFF POWER BEFORE CONNECTING WIRES.
Black wire connect to L, White wire connect to N, Green wire connect to
GROUND.
For 0-10v dimming, the wiring direction as below:
- Turn off the power.
- Connect the BLACK wire with the LINE.
- connect the WHITE wire with the COMMON.
- Connect the GREEN wire with the GROUND Caution: DO NOT connect the GRAY(-)DIM V- wire with GROUND..
- Connect the PURPLE wire with the (V+)DIM.
- Connect the GARY wire with the (V-) DIM.
INSTALLATION:
Tools: Phillips head screw driver and electrical wiring tools.
The fixture must be mounted on the wall with lens facing down as shown with
picture..
- Lag Bolt Location
- Junction BoX Mounting Holes
9244 Markville Dr.Suite A Dallas TX 75243 001-9729517795 www.ledsion.com
LS-FWP-A.0
Read User Manual Online (PDF format)