LEDSION 2FWP80W-120V-50K Watts Select Full CutOff LED WallPack User Guide

August 11, 2024
LEDSION

Watts Select Full CutOff LED WallPack

Date: Location:
Product:
Project:
Quantity:
Catalog#

FEATURES
  • Built in Watts Selector and photocell options
  • Architecture design, Easy installation.
  • Wet location rated IP65.
  • Durable die-cast aluminum housing.
  • Photocell and motion sensor options.
  • UV-resistant polycarbonate refractor lens.
  • Emergency power 4W & operating time 1.5 hours.
  • TypeII / TypeIII / TypeIV distribution optics standard
SUITABLE APPLICATIONS
  • Warehouses
  • Factories
  • Shopping Malls
  • Supermarkets
  • Logistic Centers

CONSTRUCTION:
Heavy die-cast aluminum alloy housing with bronze powder – coated finish. High light transmittance PC lens.

OPTICAL SYSTEM:
High brightness Lumileds 3030LED chips. Full Cutoff illumination

WARRANTY:
5- year limited warranty. Actual performance may differ as a result of end- user environment and application.

ELECTRICAL:
Available as 120-347V input. -30°C to 45°C

INSTALLATION & MOUNTING:
Wall Mounting with install accessories for easy installation.

CONTROLS & DIMMING
0-10V dimming comes standard. Photocell is included

PERFORMANCE

Sku model no

| Adjustable power| Emergency Duration| Voltage/Current Input| Microwave Motion Sensor Effective| Kelvin Options
---|---|---|---|---|---

120V

| 277V|

347V

2FWP80W-120V-50K| 20W| 1.5H| 0.16A| 0.07A| 0.05A| 40FT|

3000K/4000K/5000K

40W

| 1.5H| 0.33A| 0.14A| 0.11A| 40FT| 3000K/4000K/5000K
60W| 1.5H| 0.50A| 0.21A| 0.17A| 40FT|

3000K/4000K/5000K

80W

| 1.5H| 0.62A| 0.28A| 0.23A| 40FT| 3000K/4000K/5000K
2FWP100W-120V-50K| 60W| 1.5H| 0.50A| 0.21A| 0.17A| 40FT|

3000K/4000K/5000K

80W

| 1.5H| 0.62A| 0.28A| 0.23A| 40FT| 3000K/4000K/5000K
100W| 1.5H| 0.83 A| 0.36A| 0.28A| 40FT|

3000K/4000K/5000K

120W

| 1.5H| 0.83 A| 0.36A| 0.28A| 40FT|

3000K/4000K/5000K

LIGHTING


Features


  1. Integrated Photocell
  2. Plug-in Haisen Photocell
PRODUCT ORDERING GUIDE

2                      Generation II
FWP                Full Cut-Off Wall Pack
30W Power30W          40W Power40W
60W Power60W          80W Power80W
100W Power100W      120W Power120W
30K CCT:3000K          40K CCT:4000K
50K CCT:5000K

 Electric Characteristic

Adjustable power

| 2FWP80W-120V-50K
---|---
LED Driver|

UL listed WELEDPOWER Brand 0-10V dimmable

Input power

| 20W| 40W| 60W| 80W
Lumens output| 3600LM| 5200LM| 6500LM|

10400LM

Efficiency

| 130LM/W| 130LM/W| 130LM/W| 130LM/W
CRI| >72| >72| >72|

72

Color Temperature

| 5000K| 5000K| 5000K| 5000K
Input voltage| 120-347V/AC| 120-347V/AC| 120-347V/AC|

120-347V/AC

Light distribution type

| Type II III IV| Type II III IV| Type II III IV| Type II III IV
Working temperature| -30+45℃| -30+45℃| -30+45℃|

-30+45℃

Junction temperature

| <75℃| <75℃| <75℃| <75℃
lamps efficiency| ≥90%| ≥90%| ≥90%|

≥90%

Certificate

| UL CUL DLC| UL CUL DLC| UL CUL DLC| UL CUL DLC
Equivalent| 60-90W MH/HPS| 90- 120W MH/HPS| 120-150W MH/HPS|

180-240W MH/HPS

Adjustable power

| 2FWP100W-120V-50K
---|---
LED Driver|

UL listed WELEDPOWER Brand 0-10V dimmable

Input power

| 60W| 80W| 100W| 120W
Lumens output| 7800LM| 10400LM| 13000LM|

15600LM

Efficiency

| 130LM/W| 130LM/W| 130LM/W| 130LM/W
CRI| >72| >72| >72|

72

Color Temperature

| 5000K| 5000K| 5000K| 5000K
Input voltage| 120-347V/AC| 120-347V/AC| 120-347V/AC|

120-347V/AC

Light distribution type

| Type II III IV| Type II III IV| Type II III IV| Type II III IV
Working temperature| -30+45℃| -30+45℃| -30+45℃|

-30+45℃

Junction temperature

| <75℃| <75℃| <75℃| <75℃
lamps efficiency| ≥90%| ≥90%| ≥90%|

≥90%

Certificate

| UL CUL DLC| UL CUL DLC| UL CUL DLC| UL CUL DLC
Equivalent| 150-180W MH/HPS| 180-240W MH/HPS| 240-320W MH/HPS|

320-400W MH/HPS

DIMENSION

30-60W(120-277VAC&120-347VAC)/80W(120-277V AC)

80W(120-347VAC)/100-120W(120-277V AC&120-347VAC)

DISTRIBUTION DIAGRAM

30W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 30W           C0/180,143
Lumens:3900LM                               C30/210,102.3
Test Number:30W                             C60/240,109.8
Test Number:5000K                               C90/270,50

40W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 40W            C0/180,143
Lumens:5200LM                               C30/210,102.3
Test Number:40W                             C60/240,109.8
Test Number:5000K                               C90/270,50

60W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 60W            C0/180,143
Lumens:7800LM                               C30/210,102.3
Test Number:60W                             C60/240,109.8
Test Number:5000K                               C90/270,50

80W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 80W            C0/180,143
Lumens:10400LM                             C30/210,102.3
Test Number:80W                             C60/240,109.8
Test Number:5000K                               C90/270,50

100W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 100W          C0/180,143
Lumens:13000LM                              C30/210,102.3
Test Number:100W                             C60/240,109.8
Test Number:5000K                               C90/270,50

120W

AVERAGE BEAM ANGLE(50%): 92°

UNIT:CD
Test Number:LS- FWPV2- 120W          C0/180,143
Lumens:15600LM                              C30/210,102.3
Test Number:120W                           C60/240,109.8
Test Number:5000K                               C90/270,50

INSTALLATION:
  1. Unscrew door with Philips screwdriver by loosening (2) screws. Confirm junction box size and junction box mounting provisions to that of the light fixture.

  2. Attach the light fixture to the junction box or mounting surface.

  3. Attach the appropriate wires to the light fixture wires, green to green, black to black and white to white. Secure each wire pair with a wire nut (Wiring instruction FYI.)

  4. Close the door and tighten(2) screws on the door lens. Nothing should

  5. (2) screws

  6. HOUSE

  7. DOOR LENS

MAINTENANCE CAUTION:
  1. Review the diagrams before beginning, and make sure the fixture is grounded properly.
  2. Turn the power off and wait for fixture cooling to operate.
  3. This fixture has to be installed or maintenance in accordance with the application code by a professional person who familiar with the construction and operation of the product and the hazards involved. construction and operation of the product and the hazards involved.
WARRANTY:

5- YEAR WARRANTY.
If this product fail to perform satisfactorily due to defect or poor workmanship within five years from the date of purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential damages are excluded from the warranty.

DIMENSIONAL DRAWING:

30-80W

100-120W

SAFETY INSTRUCTION:
  1. This fixture must be wired in accordance with the international electrical code and applicable local codes and ordinances.
  2. Proper grounding is required to insure personal safety. Carefully observe the correct grounding procedure under installation section.
  3. Make sure power off before installing or maintaining fixture.
  4. Check that voltage is compatible with fixture driver, use approved connectors for all electrical connections.
CLEANING:
  1. Before touching fixture, make sure the fixture is cooling.
  2. Do not clean or maintain while fixture is energized.
  3. Clean lens & fixture with non- abrasive glass cleaning solution.
  4. Do not open fixture to clean and touch LED chips.
WIRING INSTRUCTION:

WARNING: TURN OFF POWER BEFORE CONNECTING WIRES.
Black wire connect to L, White wire connect to N, Green wire connect to GROUND.
For 0-10v dimming, the wiring direction as below:

  1. Turn off the power.
  2. Connect the BLACK wire with the LINE.
  3. connect the WHITE wire with the COMMON.
  4. Connect the GREEN wire with the GROUND Caution: DO NOT connect the GRAY(-)DIM V- wire with GROUND..
  5. Connect the PURPLE wire with the (V+)DIM.
  6. Connect the GARY wire with the (V-) DIM.
INSTALLATION:

Tools: Phillips head screw driver and electrical wiring tools.
The fixture must be mounted on the wall with lens facing down as shown with picture..

  1. Lag Bolt Location
  2. Junction BoX Mounting Holes

9244 Markville Dr.Suite A Dallas TX 75243   001-9729517795 www.ledsion.com

LS-FWP-A.0