SANYO KS2432 Split System Air Conditioner
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information:
- Model No.
- Serial No.
- Date of purchase
- Dealer’s address
- Phone number
Alert Symbols
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel, or the appliance:
- Danger: This symbol refers to a hazard or unsafe practice that can result in severe personal injury or death.
- Caution: This symbol refers to a hazard or unsafe practice that can result in personal injury or product or property damage.
Safety Instructions
To ensure the safe and proper usage of your air conditioner, please follow these instructions:
- Installation Location:
Avoid installing the air conditioner in a location where it may be exposed to direct sunlight or rain, as this may affect its performance and durability. Additionally, ensure that there is adequate space around the unit for proper airflow.
- Electrical Requirements:
All wiring must conform to local electrical codes. Consult your dealer or a qualified electrician for specific details. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
- Power Mains:
To warm up the system, the power mains must be turned on at least five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period. (CL MODEL)
Note: It is important to keep the power mains ON to ensure the proper functioning of the air conditioner.
- Gas or Oil Heating Appliances:
If you use gas or oil heating appliances in the same room, make sure to open doors or windows frequently to allow for sufficient oxygen supply. Failure to do so may result in a risk of suffocation.
Names of Parts
Each air conditioner consists of an indoor unit and an outdoor unit. You can
control the air conditioner with the remote control unit.
- Wall-mounted type:
- Air intake
- Air outlet
- Drain tube
- Remote control unit
- Refrigerant tubes
- Ceiling-mounted type:
- Air outlet
- Air intake
- Drain tube
- Remote control unit
- Refrigerant tubes
- Recessed type:
- Air intake
- Air outlet
- Drain tube
- Remote control unit
- Refrigerant tubes
- Drain hose
Product Usage Instructions
Step 1: Installation
Follow these steps to install your air conditioner:
- Select an appropriate location for installation, considering factors such as direct sunlight, rain exposure, and proper airflow.
- If required, consult a qualified electrician to ensure proper wiring and grounding as per local electrical codes.
- Install the indoor unit by securely mounting it on the wall or ceiling, depending on the type of air conditioner.
- Connect the indoor and outdoor units using the provided refrigerant tubes.
- Ensure that the drain tube is properly connected and directed to a suitable drainage system.
- Place the remote control unit in a convenient location for easy access.
- Once the installation is complete, turn on the power mains and allow the system to warm up for at least five (5) hours before operation.
Step 2: Operation
Follow these steps to operate your air conditioner:
- Ensure that the power mains are turned on.
- Use the remote control unit to power ON/OFF the air conditioner.
- Select the desired operation mode (cooling or fan) using the mode selection button on the remote control.
- Adjust the temperature settings according to your preference.
- Control the fan speed using the fan speed adjustment button on the remote control.
- Utilize the timer setting function, if desired, to schedule automatic ON/OFF operations.
- Adjust the direction of airflow using the air sweeping function on the remote control.
Specifications
- Model: Wall-mounted type KS2432, KS3032, KS3632;Ceiling-mounted type TS2432, TS3632, TS4232; Recessed type XS1822, XS1852, XS2432, XS3632, XS4232
- Function: Cooling/Fan
FAQ
Q: Where can I find the model and serial numbers of my air conditioner?
A: The model and serial numbers are located on the nameplate on the bottom
of the cabinet.
Q: What should I do if I have problems or questions regarding my air
conditioner?
A: Refer to the product information section for details on obtaining
assistance. Make sure to have the model and serial numbers, date of purchase,
dealer’s address, and phone number ready when contacting support.
Q: How do I ensure the safety of using my air conditioner?
A: Follow the safety instructions provided in the manual,including proper
installation, electrical requirements, and precautions when using gas or oil
heating appliances in the same room.
INSTRUCTION MANUAL
Split System Air Conditioner
COOL/FAN Model
Wall-mounted type | Ceiling-mounted type | Recessed type |
---|---|---|
KS2432 | TS2432 | XS1822, XS1852 |
KS3032 | TS3632 | XS2432 |
KS3632 | TS4232 | XS3632 |
XS4232 |
Features
These air conditioners are equipped with cooling function. Details on this function are provided below; refer to these descriptions when using the air conditioner.
-
Microprocessor Controlled Operation
The interior compartment of the remote control unit contains several features to facilitate automatic operation, easy logically displayed for easy use. -
Simple One-touch Wireless Remote Control
The remote control unit has several features to facilitate automatic operation. -
24-hour clock with ON/OFF Program Timer
The wireless remote controller allows you to set up a wide variety of time based operations.
Such functions include automatic on/off with time settings, same time on/off every day, on timer and off timer. -
1-Hour OFF Timer
This timer can be set to automatically turn off the unit at any time after one hour. -
Night Setback
Pressing this button changes the setting of the room temperature thermostat, allowing you to set the temperature at whatever level that you find comfortable. -
Automatic and 3-step Fan Speed
Auto/High/Medium/Low -
Air Sweep Control
This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner. -
Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed operation can be reactivated once power resumes. -
Anti-Mold Filter
This unit is equipped with an anti-mold filter that inhibits the growth of mold and bacteria.
Product Information
If you have problems or questions concerning your Air Conditioner, you will
need the following information. Model and serial numbers are on the nameplate
on the bottom of the cabinet.
Model No. Serial No.
Date of purchase
Dealer’s address
Phone number
Alert Symbols
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
WARNING
This symbol refers to a hazard or unsafe practice which can result in severe
personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which can result in
personal injury or product or property damage.
Installation Location
- We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
- Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
WARNING
- Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.
- Do not install the air conditioner where excessively high heatgenerating objects are placed.
Avoid:
- To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.
- The unit may malfunction when the receiver in the indoor unit is exposed to the inverter lamp light.
Electrical Requirements
- All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.
- Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
- Wiring must be done by a qualified electrician.
- Power supply: 60 Hz, single-phase, 230/208 volts.
CAUTION
To warm up the system, the power mains must be turned on at least five (5)
hours before operation. Leave the power mains ON unless you will not be using
this appliance for an extended period.
(CL MODEL)
Safety Instructions
- Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
- This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
WARNING
- Never touch the unit with wet hands.
- Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.
- This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
CAUTION
- Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
- Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
- Do not let children play with the air conditioner.
- Do not cool the room too much if babies or invalids are present.
Names of Parts
Each air conditioner as shown below consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit.
NOTE
This illustration is based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner which you
have selected.
Air intake| The return air in the room is drawn into this section and
passes through air filters which remove dust and foreign particles.
---|---
Air outlet| Conditioned air is returned to the room through the air
outlet (ceiling and wall mounted type) or four air outlets (Recessed type).
The direction of airflow can be adjusted as desired using the remote control unit.
Remote control unit| The wireless remote control unit controls power
ON/OFF, operation mode selection, temperature, fan speed, timer setting, and
air sweeping.
Refrigerant tubes| The indoor and outdoor units are connected by copper
tubes through which refrigerant gas flows.
Drain tube| Moisture in the room is condensed and drains off by means of
this tube.
Outdoor (condensing) unit| The outdoor unit contains the compressor, fan
motor, heat exchanger coil, and other electrical components.
Unit Display and Operation Selector
REMOTE CONTROL
receiver
| This section picks up infrared signals from the remote control unit
(transmitter).
---|---
| Operation selector
ON position
| ****
This position is for operating the air conditioner with the wireless remote control unit.
Set the selector normally in this position.
OFF position| Switch the selector to the OFF position if you are not going to use the air conditioner for a few days or longer.
The OFF position does not disconnect the power. Use the main power switch to turn off power completely.
TEST position
CAUTION
| This position is used only when servicing the air conditioner.
Do not set at the TEST position for normal operation.
OPERATION lamp| This lights when the system is in the continuous COOL or
FAN mode.
TIMER lamp| This lamp lights when the system is being controlled by the
timer.
Remote Control Unit (Display)
Symbols
Remote Control Unit
NOTE
The illustration above pictures the remote control unit after the cover has
been lowered and removed.
Transmitter| When you press the buttons on the remote control unit, the
mark appears in the display to transmit the setting changes to the receiver in
the air conditioner.
---|---
Sensor| A temperature sensor inside the remote control unit senses the
room temperature.
Display| Information on the operating conditions is displayed while the
remote control unit is switched on. If the unit is turned off, only the mode
that was set previously is still displayed.
NIGHT SETBACK button| For details, see “Night Setback Mode”. When you
press this button in the COOL mode, the mark appears in the display, and the
remote control unit automatically adjusts the set temperature to save energy.
Temperature setting buttons (TEMP.)| Press the button to
increase the set temperature. Press the button to reduce the set temperature.
ON/OFF operation button| This button is for turning the air conditioner
on and off.
Timer and Present Time
setting buttons
| First, press the program button to select the mode you want. Each time you press the “HH” button, the hours advance by one.
Each time you press the “MM” button, the minutes advance by one.
Program button| For details, see “Setting the Timer”.
Press this button to select the mode you want to program.
---|---
TIMER SELECT button| No display : The timer does not operate.
: The air conditioner stops at the set time.
: The air conditioner starts at the set time.
: The air conditioner stops and starts, or starts and stops, at the set times every day.
MODE selector button
(COOL)
(FAN)
| Use this button to select the COOL or FAN mode.
: The air conditioner makes the room cooler.
: The air conditioner works only as a circulation fan.
FLAP button| Press this button to select the sweep function, which moves the flap up and down automatically.
: The flap moves up and down automatically.
FAN SPEED selector button| : The air conditioner automatically decides the fan speeds.
: High fan speed
: Medium fan speed
: Low fan speed
1 HR. TIMER button (1-HOUR OFF TIMER)| : When you
press this button, regardless of whether the unit is operating or stopping,
the unit operates for one hour and then shuts down.
ACL button (ALL CLEAR)| Puts the remote control unit into pre-operation
status. Always press this button after replacing the batteries.
ADDRESS switch| • Change the address switch to prevent mixing of
signals from remote control units when two Sanyo air conditioners are
installed next to each other. Normally, the remote control address switch is
set to A. For the second indoor unit, both addresses of the remote control
unit and the indoor unit must be changed. The second remote control unit
address must be changed to B by breaking off the tab ”A“. And the second
indoor unit address must be changed from 1-OFF, 2-OFF to 1-ON, 2-ON by
switching the dip switch in the indoor unit. For more information, please
contact the dealer where you made the purchase.
• Normally, the tabs on the remote control unit should not be bent.
SENSOR button
NOTE
| When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.
If the remote control is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.
NOTE
The remote control unit sends the temperature signal to the air conditioner
regularly at five minute intervals. If the signal from the remote control unit
stops for more than ten minutes due to the loss of the remote control unit or
other trouble, the air conditioner will switch to the temperature sensor which
is built into the indoor unit and control the room temperature. In these
cases, the temperature around the remote control unit may differ from the
temperature detected at the air conditioner’s position.
Using the Remote Control Unit
How to Install Batteries
- Slide the cover in the direction indicated by the arrow and remove it.
- Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment.
- Use a thin object such as the tip of a pen to press the ACL button.
NOTE
- The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit’s display fails to indicate, or when the remote control cannot be used to change the air conditioner’s settings.
- Use two fresh leak-proof type-AAA alkaline batteries.
- In replacing batteries, follow the instructions as mentioned in the sub-section “How to Install Batteries”.
- If you do not use the remote control unit more than 1 month, take out the batteries.
How to Use the Remote Control Unit
When using the remote control unit, always point the unit’s transmitter
head directly at the air conditioner’s receiver.
Remote Control Unit Installation Position
The remote control unit may be operated either from a non-fixed position or
from a wall-mounted position. To ensure that the air conditioner operates
correctly, DO NOT install the remote control unit in the following places:
DO NOT
- In direct sunlight
- Behind a curtain or other places where it is covered
- More than 26 feet (8 m) away from the air conditioner
- In the path of the air conditioner’s airstream
- Where it may become extremely hot or cold
- Where it may be subject to electrical or magnetic noise
- Where there is an obstacle between the remote control unit and air conditioner (since a check signal is sent from the remote control unit every 5 minutes)
Mounting the Remote Control Unit
When attaching to wall
- Confirm the indoor unit beeps when the ON/OFF button is pressed at the wall location where the remote control unit is to be attached, then attach the holder to the wall.
- When taking out the remote control unit, pull it from the holder.
When using the remote control unit
- Point the transmitter on the remote control unit at the sensor on the indoor unit when operating the remote control unit and the air conditioner.
- Do not place objects which may block the transmitted signals between the receiver and the remote control unit.
Securing the remote control unit to prevent theft
- Attach the holder to the wall with one screw in the upper hole only.
- Remove the cover from the remote control unit, and then remove the batteries. Next, place the remote control unit in the holder.
- Secure both the remote control unit and the holder to the wall with another screw through the lower hole.
- Put the batteries back in the remote control unit, and then replace the cover.
Operation with the Remote Control Unit
Operation
NOTE
Check that the circuit breaker on the power panel is turned on and that the
operation selector of the indoor unit is in the ON position.
Press the setting buttons as described below and change the settings as desired.
STEP 1 | Set the MODE selector button to COOL. For cooling operation |
---|---|
STEP 2 | To start the air conditioner, press the ON/OFF operation |
button.
STEP 3
NOTE
| Press theTEMP. setting buttons to change the temperature setting to the desired temperature.
Adjustable temperature range:
86 °F max.
60 °F min.
The temperature setting changes by two degrees each time the button is pressed. (The air conditioner remembers the new temperature setting even when it is turned off.)
STEP 4 NOTE| Set the FAN SPEED selector button to the setting you want.
If the fan speed is set to (Automatic), the fan speed switches automatically, according to the difference between the actual room temperature and the temperature setting.
STEP 5| Press the FLAP button and set the airflow direction as desired.
(Refer to ‘‘Adjusting the Airflow Direction’’ on page 20.)
To stop the air conditioner, press the ON/OFF operation button again.
NOTE
- Choose the best position in the room for the remote control unit, which also acts as the sensor for room comfort and transmits the operating instructions. Once you’ve found this best position, always keep the remote control unit there.
- This appliance has a built-in 3-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. When the power is restored, the unit will restart automatically after three minutes.
Adjusting the Fan Speed
A. Automatic
Simply set the FAN SPEED selector to the position.
A microcomputer in the air conditioner automatically controls the fan speed
when the mode is selected. When the air conditioner starts operating, the
difference between the room temperature and the set temperature is detected by
the microcomputer which then automatically switches the fan speed to the most
suitable level.
Cooling mode:
When difference between room temperature and set temperature is| FAN
SPEED
---|---
4 °F and over| High
Between 4 °F and 2 °F| Medium
Below 2 °F| Low
The above table assumes that the sensor on the remote control is being used.
If the sensor on the indoor unit is being used (the indicator is on), actual
operation may differ slightly from the operation described in the table.
(Refer to ‘‘SENSOR button’’ on page 10.)
B. Manual
If you want to adjust fan speed manually during operation, just set the FAN
SPEED selector as desired. [ , , or ]
Fan Only
If you want to circulate air without any temperature control, follow these steps:
STEP 1: Press the MODE selector button to switch to the fan mode.( )
STEP 2: Press the ON/OFF button.
STEP 3: Press the FAN SPEED button to select the fan speed of your choice ( , ,or ).
Night Setback Mode
Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while operation.
The mark appears in the display.
To release the night setback function, press the NIGHT SETBACK button again.
NOTE
The night setback mode cannot be used during automatic operation.
In Cooling Mode: ( )
When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed.
Special Remarks
Power failure during operation
- In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically after three minutes.
Remote Control Unit
- The remote control unit sends the setting condition to the air conditioner regularly at three minute intervals.
Setting the Timer
NOTE
When the Daily ON/OFF program is set to start the air conditioner before the
ON time setting, the indications appear on the display.
On the other hand, when the Daily ON/OFF program is set to start the air
conditioner after the ON time setting, the indications appear on the display.
Thus, these indications show the timer program which will operate next.
You can check the timer ON/OFF times after you have set them by pressing the
PROGRAM button.
Using the 1-Hour OFF Timer
1-Hour OFF Timer
This function causes the unit to operate for one hour and then stop,
regardless of whether the unit is on or off when this button is pressed.
The indicator in the display indicates that this function is operating.
Setting procedure:
Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER
button.
appears in the display.
Cancellation procedure:
Press the ON/OFF operation button to turn the unit off, wait for the unit to
stop operating, and then press the ON/OFF operation button again. The 1-Hour
Timer function is now cancelled and the unit operates normally.
NOTE
- If, while the 1-Hour Timer function is operating, the 1 HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.
Operation Together with the Program Timer
- The 1-Hour OFF Timer setting is given priority over the daily program setting.
- It is not possible to use the OFF Timer and 1-Hour OFF Timer together.
Whichever function is set last takes precedence.
If the 1 HR. TIMER button is pressed while the TIMER OFF function operates,OFF Timer is cancelled and the unit will stop operating one hour later.
Adjusting the Airflow Direction
Horizontal (Wall mounted type only)
The horizontal airflow can be adjusted by moving the vertical vane to the left
or right.
Vertical
Confirm that the remote control unit has been turned on. Press the FLAP button
to start the flap moving up and down ( ). If you want to stop the flap
movement and to direct the air in the desired direction, press the FLAP button
again. In the COOL mode, don’t direct the flap down more than 30 ° (KS, TS
Types), or leave it in the vertical position (XS Type), otherwise condensation
may drip onto the floor. Zone ‘‘A’’ (KS, TS Type) and any position other than
vertical (XS Type) are the recommended flap positions for cooling.
CAUTION Do not move the flap with your hands.
Operation without the Remote Control Unit
If you have lost the remote control unit or it has trouble, follow the steps below.
-
When the air conditioner is stopped.
If you want to turn on the air conditioner, switch the operation selector to the OFF position, and then to the ON position.
NOTE The set temperature and fan speed are automatically set at the last selection before stopping. -
When the air conditioner is running.
If you want to turn off the air conditioner, switch the operation selector to the OFF position.
Care and Cleaning
WARNING
- For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.
- Do not pour water or spray detergent on the indoor unit to clean it.
This will damage the internal components and may cause an electric shock or fire.
Air Intake and outlet side (Indoor Unit)
Clean the air intake and outlet side of the indoor unit with a vacuum cleaner
brush, or wipe them with a clean soft cloth.
If these parts are stained, use a clean cloth moistened with a mild liquid
detergent. When cleaning the air outlet side, be careful not to force the
vanes out of place.
CAUTION
- Never use solvents or harsh chemicals when cleaning the indoor unit. Do not wipe plastic parts using very hot water.
- Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.
- The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center.
Air filter
The air filter collects dust and other particles from the air and should be
cleaned about once every six months (Recessed type) or two weeks (ceiling
mounted type and wall mounted type). If the filter gets blocked, the
efficiency of the air conditioner drops greatly.
NOTE
The frequency with which the filter should be cleaned depends on the
environment in which the unit is used.
How to remove the filter Recessed type:
-
Remove the bolt screw on each side out of the latch using a screwdriver. (After cleaning, be sure to reattach the two bolt screws.)
-
Press on the two latches of the air intake grille with your thumbs in the direction of the arrow to open the grille.
-
Open the air intake grille downward.
CAUTION
When cleaning the air filter, never remove the safety string. If it is necessary to remove it for servicing and maintenance inside, be sure to reinstall the safety string securely (hook on the grille side) after the work.
-
Remove the air filter attached to the air intake grille.
How to remove the filter Ceiling mounted type:
- Remove the bolt screws on the latch using a screwdriver. (After cleaning, be sure to reattach the two bolt screws.)
- Take hold of two latches on the air intake grille and press it to the rear,and the grille will open downward.
- Take hold of the finger-hold on the air filter, first lift it and then pull it toward you to release it from the catch.
How to remove the filter Wall type
- Move the flap on the air outlet grille to its lowest position.
- Hold the air filter by the tab at the bottom, and pull downward.
How to clean the filter
Use a vacuum cleaner to remove light dust. If there is sticky dust on the
filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and
dry it.
Outdoor Unit
CAUTION
- Certain metal edges and the condenser fins are sharp and may cause injury if handled improperly; special care should be taken when you clean these parts.
- Periodically check the outdoor unit to see if the air outlet or air intake is clogged with dirt or soot.
- The internal coil and other components of the outdoor unit must also be cleaned periodically. Consult your dealer or service center.
Care: After a Prolonged IdlePeriod
Check the indoor and outdoor unit air intakes and outlets for blockage; if there is a blockage, remove it.
Care: Before a Prolonged Idle Period
- Operate the fan for half a day to dry out the inside.
- Disconnect the power supply and also turn off the breaker.
- Clean the air filter and replace it in its original position.
- Outdoor unit internal components must be checked and cleaned periodically. Contact your local dealer for this service.
Troubleshooting
If your air conditioner does not work properly, first check the following
points before requesting service.
If it still does not work properly, contact your dealer or service center.
Trouble | Possible Cause | Remedy |
---|---|---|
Air conditioner does not run at all. | 1. Power failure. |
2. Leakage breaker tripped.
3. Line voltage is too low.
4. ON/OFF operation button is OFF.
5. Batteries in remote control unit have run down.
| 1. Restore power.
2. Contact service center.
3. Consult with electrician or dealer.
4. Press the button again.
5. Replace batteries.
Compressor runs but soon stops.| 1. Obstruction in front of condenser coil.|
1. Remove obstruction.
Poor cooling performance.| 1. Dirty or clogged air filter.
2. Heat source (cooker, heater, or electrical appliance) or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high.
| 1. Clean the air filter to improve the air flow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat out.
4. Remove it to ensure good air flow.
5. Set the temperature lower.
Tips for Energy Saving
Do not
- Block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
- Let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.
Do
-
Always try to keep the air filter clean. (Refer to ‘‘Care and Cleaning.’’)
A clogged filter will impair the performance of the unit. -
To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
NOTE Should the power fail while the unit is running
If the power supply for this unit is temporarily interrupted the unit will
automatically resume operation (once the power is restored) with the same
settings that were in effect before the power was interrupted.
Operating Range
The air conditioner is operable within the temperature ranges as listed below:
Temperature | Indoor air temperature | Outdoor air temperature | |
---|---|---|---|
COOLING | Max. | 95 °F DB/71 °F WB | 115 °F DB |
Min. | 67 °F DB/57 °F WB | 67 °F DB *(0 °F DB) |
Only for CL Models.
SANYO FISHER COMPANY
A DIVISION OF SANYO NORTH AMERICA CORPORATION
21605 Plummer Street
Chatsworth, CA 91311 U.S.A.
In Canada
SANYO Canada Inc.