PYMETER PY-23T PID Dimming Thermostat Instruction Manual
- August 13, 2024
- Pymeter
Table of Contents
Pymeter PID Dimming Thermostat
Overview
Pymeter PID dimming thermostat is designed for controlling and regulating the
temperature of various heating equipments, such as heat mats, lamps and
aquarium heater. It features a digital display and adjustable temperature
settings, allowing you to customize the temperature to meet your reptile’s
specific needs. It also includes a PID function for improved accuracy and
stability, as well as a dimming function for adjusting the brightness of the
heat lamp. This PID thermostat is easy to use and install, and it
comes with all necessary wiring and accessories for a quick and hassle-free
setup.
Model꞉ PY-23T
Power Consumption꞉ ≤ 1.5W
Input꞉ 85~250V, 50/60Hz
Output꞉ 85~250V, MAX 500W
Size꞉ 129 x 37.5 x 18.3 mm / 5.08″ x 1.48″ x 0.72″
Weight꞉ 209g / 7.4oz
Power Cord꞉ 140cm / 4.59ft
Sensor Cord꞉ 160cm / 5.28ft
Jack꞉ 9.3cm / 3.7″
Temperature Set Range꞉ 4℃~55℃ / 40℉~131℉
Temperature Accuracy꞉ ± 1℃ / 1℉
Timer꞉ 2, 4, 8, 12 hours; default꞉ always ON
Operation
Quick Start
1. “Power On, plug the thermostat to wall socket. The display lights up
automatically and shows the real-time temperature.
2. ‘Adjust Temperature; press or buttons below “TEMP” to set desired
temperature you need to maintain. It keeps constant temperature within 1°F by
regulating the heater power, instead of turning ON/OFF.
3. [Adjust Timer, if need to set timer, press or buttons below “TIME”. It
shows according number(hours) on display. When the set time is reached, the
thermostat will automatically turn off the power.
4. ‘Manual Switch, if need to switch off /on the thermostat manually, hold
the button for 5 seconds.
5. “Fix the Probe make sure the sensor always stays fixed to the hot spot
where needs to monitor / maintain temperature.
6. “Plug in Heater) attach heater to the jack of thermostat, if current
temperature is lower than set temperature, it starts to regulate the power to
heater and keep temperature constant at the set temperature.
- Pressthe TEMP or buttononce, it shows the set temperature, press again to change the value. If setting value is not changed, the display flickers twice then exit the setting. If setting value is changed, the display flickers thrice then exit the setting.
- Under query or setting mode, the dot behind the temperature reading remains lit. The dot keeps flickering till current temperature reaches the set temperature.
- To use with heat lamp, please do keep the bulb 30~50cem / 12″~20″ away from the sensor, and make sure the sensor stays fixed to the hot spot Which ie exposed lo the light linsteud of tareway” from the heat source!) and not covered by anything. If the distance is too close (“too far), it will cause overheating, and the light will be dimmed off (“take long time or unable to reach the set temperature), please adjust the distance to keep steady light / consistent temperature.
- Temp set range does not mean it can reach that temp, the highest temp it can reach is up to the attached heater, please also notice it can not get to a temp lower than ambient temp.
Dimming
Keep Constant Temperature and Gentle Light.
Adjust lamp height
Please adjust the distance between the lamp and the sensor for steady light and constant temperature. The distance varies due to lamps of different wattages.
Warranty & Support
Pymeter products are provided Lifetime Warranty and One Year Exchange / Refund
Guarantee.
Any question / issue, don’t hesitate to contact us anytime via Email
support@pymeter.com or Livechat below.
|
---|---
https://www.pymeter.com/PYMETER-PID-DIMMING-THERMOSTAT.pdf|