Mission Air ARIES LCD Temperature Controller Instruction Manual

August 9, 2024
Mission Air

Mission Air ARIES LCD Temperature Controller

INTRODUCTION

The AIRES LCD thermostat is a high quality thermostat with a minimalist design. It has been designed to accurately control air and floor temperature for electric underfloor heating systems with a maximum load of 3600W/16A. When using it for the first time, enter the advanced settings to set the load power (function and action code: 08: 0:?2900~3600W 1: 1800~2900W 2:?0~1800W)

TECHNICAL SPECIFICATIONS

  • Voltage: 120~240V 50/60Hz
  • Maximum load: 16A
  • Wiring specification: ≤ 2.5 mm²
  • Standby power consumption: < 1W
  • Class: IP 21
  • Floor temperature protection limit: 30℃

INSTALLATION

Step 1: Use a flathead screwdriver to separate the bezel and adapter from the thermostat as shown.

Step 2: Connect the appropriate circuit as shown.

Step 3: Use the mounting screws to fix the thermostat in the mountingbox/cabinet.

Step 4: Install the frame and adapter in the thermostat.

If a frame with an internal dimension of 56×56 mm is used, the frame and thermostat adapter must be installed as shown in the diagram opposite. If using the Schneider Unica frame, install the frame and adapter to the thermostat as shown opposite.

If the Legrand Valena series is used, install the frame and thermostat adapter as shown in the diagram opposite.

CONNECTION INSTRUCTIONS

  • L/N: Connect the power cable.
  • L1/N1:Connect the heating system.
  • Sensor: Connect the floor sensor.
  • Suggestion: Keep the maximum load at around 90% of 16A to extend the life.

DIMENSION (MM)

SYMBOLS

FUNCTIONS AND OPERATIONS

IMPORTANT!
The ARIES LCD thermostat can operate in floor sensor / air sensor mode / or both at the same time. In floor sensor mode, the display allows you to set the floor temperature. In air sensor mode, the display allows you to set the desired room air temperature. In the common mode, the display is used to set the air temperature and the floor temperature is automatically set to the maximum protection level of 30℃ each time.

  1. On/Off
    Setting method:

    • A. Switching on
      Once the thermostat has woken up, press and hold the + button for 3 seconds to switch it on.

    • B. Switching off
      After waking up the thermostat while the floor temperature is displayed, press and hold the + button for 3 seconds to switch the unit off.
      When the frost protection function is activated, the thermostat will maintain the floor temperature at 5°C in the off state.

  2. Temperature setting
    Once the user has set the temperature, the thermostat maintains the temperature at the set level. When the power is switched off and on again, the originally set temperature is retained and executed. Thermostat setting: 5-40°C.
    Setting method:
    Once the thermostat has woken up, press the +/- button to change the set temperature. Once set, wait 5 seconds and then return to the temperature display.

  3. Button lock
    A key lock can be set for the thermostat when children or the elderly should not operate the thermostat. When the power is switched off and on again, the key lock will continue to operate.
    Setting method:
    Once the thermostat has woken up, press and hold the – button for 3 seconds. The display shows LoC, indicating that the setting was successful. After the thermostat has woken up, press the – button for 3 seconds, the interface will display the temperature and the button lock will be cancelled.

  4. Advanced settings
    To suit a wider range of applications, the thermostat offers a number of
    special functions.

SYMBOL

01
02
03
04
NAME

Floor temperature calibration
Room temperature calibration
Type of sensor
Anti-freeze function
HOPE

0,0
0,0
1
OFF
SCOPE

-0,5℃-5℃
-0,5℃-5℃
0: room;

1: floor; 2: both

ON/ OFF

Explanation of function:
01/02 Floor/room temperature calibration. This function allows the user to correct the error of the floor/room sensor. Example: In the same environment the actual temperature is 20°C, and the thermostat displays 21°C. Then set this parameter to -1.0°C.

Setting method:

  • a. Record the actual temperature minus the difference displayed by the thermostat.
  • b. After the thermostat has woken up, press and hold the – and + buttons simultaneously for 3 seconds and the interface will display 01.
  • c. Press – to set the difference value.
  • d. Press the + button once until 02. The room temperature is calibrated in the same way.

Type of sensor
Used to select the sensor in operation. Setting method:

  • a. After the thermostat has woken up, hold down the – and + buttons for 3 seconds. The display will show 01.
  • b. Press the + button until the 03 screen is displayed.
  • c. Press the – button to select the type of sensor.
  • d. Press the + button until the temperature screen is displayed.

Anti-freeze function
When this function is activated, the floor temperature is maintained at 5°C when the thermostat is switched off.

Setting method:

  • a. Once the thermostat has woken up, press and hold the – and + buttons for 3 seconds and the interface will display 01.
  • b. Press the + button until the 04 screen is displayed.
  • c. Press the – button to select ON or OFF.
  • d. Press the + button until the temperature screen is displayed.

Standby brightness
The thermostat provides brightness control in standby mode. The brightness can be set to 0 (completely off) or 1 (minimum brightness).

Setting method:

  • a. Once the thermostat has woken up, press and hold the – and + buttons simultaneously for 3 seconds and the interface will display 01.
  • b. Press the + button until the 06 screen is displayed.
  • c. Press the – button to select the brightness.
  • d. Press the + button until the temperature screen is displayed.

Open windows
The thermostat detects a drop in temperature caused by opening a window. It temporarily switches off the heating to save energy.

Setting method:

  • a. Once the thermostat has woken up, press and hold the – and + buttons simultaneously for 3 seconds and the interface will display 01.
  • b. Press the + button until the 07 screen is displayed.
  • c. Press the – button to select OFF or ON.
  • d. Press the + button until the temperature screen is displayed.

Load power selection
Due to the power of the underfloor heating, the heat generated by the temperature controller is different, which affects the detected temperature value by the room sensor. The programme can make the appropriate correction and compensation of the detection value according to the different power.

Setting method:

  • a. After the thermostat has woken up, press and hold the – and + for 3 seconds and the interface will display 01.
  • b. Press the + button to select 08.
  • c. Press the – button to select the system power range.
  • d. Press the + button until the temperature screen is displayed.

Reset
This function restores the parameters of the set temperature and advanced settings to the factory default parameters.

PROBLEM SOLVING

Note : In the event of a fault alarm, contact a professional in this area for repair or replacement.

  • E1 : Room sensor failure alarm.
  • E2 : Floor sensor failure alarm.

www.missionair.pl
+48 797 451 111
biuro@missionair.pl

Documents / Resources

| Mission Air ARIES LCD Temperature Controller [pdf] Instruction Manual
PL, EN, DK, ARIES LCD Temperature Controller, ARIES, LCD Temperature Controller, Temperature Controller, Controller
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals