S21 Bitmain Antminer User Manual
- August 10, 2024
- BITMAIN
Table of Contents
S21 Bitmain Antminer
Specifications
Product Glance | Value |
---|---|
Model | S21 |
Sub Version | 200T |
Crypto algorithm/coins | SHA256 |
Typical Hashrate, TH/s(1-1) | 200 |
Power on wall @25(1-1), Watt(1-1) | 3500 |
Power efficiency on wall @25(1-1), J/TH(1-1) | 17.5 |
Detailed Characteristics
Value
Power supply| 220~277 Volts, 50~60 Hz
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 400195290
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 15.4
Gross weight, kg| 17.2
Noise @30, dBA| 76
Environment Requirements
Operation temperature| 0~45°C
Storage temperature| -20~70°C
Operation humidity(no condensation), RH| 10%~90%
Operation altitude(2-3), m| 2000 (temperature decreases by 1 for every
increase of300m)
Product Usage Instructions
Frequently Asked Questions (FAQ)
Specification
Product Glance | Value |
---|---|
Model | S21 |
Sub | 200T |
Version | 10 |
Crypto algorithm/coins | **SHA256 |
Typical Hashrate, TH/s (1-1) | 200 |
Power on wall @25℃(1-2), Watt (1-1) | 3500 |
Power efficiency on wall @25℃(1-2), J/TH (1-1) | 17.5 |
Detailed Characteristics | Value |
Power supply
Phase| 1
Input voltage(2-1), Volt| 220~277
Input frequency range, Hz| 50~60
Maximum input current, Amp| 20
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 400195290
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 15.4
Gross weight, kg| 17.2
Noise(2-2) @30℃, dBA| 76
Environment Requirements
Operation temperature, ℃| 0~45
Storage temperature, ℃| -20~70
Operation humidity(no condensation), RH| 10%~90%
Operation altitude(2-3), m| ≤2000
Notes:
- The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
- Inlet air temperature.
- Caution: Wrong input voltage may probably cause server damaged.
- The noise is loudest when the fan is under maximum RPM(rotation per minute).
- When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.
Performance Curves
- Hashrate vs. Ambient Temperature
- J/T vs. Ambient Temperature
References