BITMAIN S21 XP AntMiner User Manual

August 10, 2024
BITMAIN

BITMAIN S21 XP AntMiner

Specifications

Product Glance Value
Model S21 XP
Sub Version 270T
Crypto algorithm/coins SHA256
Typical Hashrate, TH/s(1-1) 270
Power on wall @25(1-1), Watt(1-1) 3645
Power efficiency on wall@25(1-2), J/TH(1-1) 13.5

Detailed Characteristics

Value

Power supply Phase| 1
Input voltage range(2-1), Volt| 220~277
Input frequency range, Hz| 50~60
Maximum input current, Amp| 20
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 449219293
Server size (LengthWidthHeight, with package), mm| 640360450
Net weight, kg| 18.7
Gross weight, kg| 21.5
Noise(2-2)@30, dBA| 76

Environment Requirements

Value

Operation temperature| -20~45°C
Storage temperature| -20~70°C

Frequently Asked Questions (FAQ)

S21 XP
Product Manual
Jul. 2024
BITMAIN
TECHNOLOGIES INC. www.bitmain.com

Specification

Product Glance Value
Model S21 XP
Sub 270T
Version 10
Crypto algorithm/coins **SHA256
Typical Hashrate, TH/s (1-1) 270
Power on wall @25℃(1-2), Watt (1-1) 3645
Power efficiency on wall@25℃(1-2), J/TH (1-1) 13.5
Detailed Characteristics Value

Power supply
Phase| 1
Input voltage range(2-1), Volt| 220~277
Input frequency range, Hz| 50~60
Maximum input current, Amp| 20
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 449219293
Server size (LengthWidthHeight, with package), mm| 640360450
Net weight, kg| 18.7
Gross weight, kg| 21.5
Noise(2-2)@30℃, dBA| 76
Environment Requirements
Operation temperature, | -20~45
Storage temperature, | -20~70
Operation humidity(no condensation), RH| 10%~90%
Operation altitude(2-3), m| ≤2000

Notes :

  1. The Hashrate value, Power on wall, and Power efficiency on wall are all typical value. The actual Hashrate value fluctuates by ±3%, and the actual Power on wall
    and Power efficiency on wall fluctuate by ±5%.

  2.  Inlet air temperature.

  3.   Caution: Wrong input voltage may probably cause server damaged.

  4.  The noise is loudest when the fan is under maximum RPM(rotation per minute).

  5.  When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.

 Performance Curves

  1. Hashrate vs. Ambient Temperature
  2. J/T vs. Ambient Temperature

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals