BITMAIN ANTMINER S19e XP Hyd 257TH/s ASIC Mining Machine User Manual
- August 9, 2024
- BITMAIN
Table of Contents
BITMAIN ANTMINER S19e XP Hyd 257TH/s ASIC Mining Machine
Specifications
Product Glance | S19e XP Hyd. |
---|---|
Model | S19e XP Hyd. |
Sub Version | |
Crypto algorithm/coins | SHA256 |
Typical hashrate, TH/s(1-1) | 251 |
Power on wall @35(1-2), Watt(1-1) | 240 |
Power efficiency on wall@35(1-2), J/T(1-1) | 22 |
Detailed Characteristics
Power supply | Phase: 3 |
---|---|
Input voltage, Volt(2-1) | 380~415 |
Input frequency range, Hz | 50~60 |
Input max current, Amp | 12 |
Hardware configuration | Network connection mode: RJ45 Ethernet 10/100M |
Server size (lengthwidthheight, w/o package), mm | 410170209 |
Product Usage Instructions
Powering On the Server
To power on the server, make sure the power supply is connected and within the specified voltage range. Press the power button to initiate the boot sequence.
Coolant Flow and Pressure
Ensure that the coolant flow is maintained between 8.0 to 10.0 L/min and the coolant pressure is within the specified range. Monitor the coolant pH value regularly as per the provided guidelines.
FAQ
- Q: What is the recommended operating temperature range for the server?
- A: The recommended operating temperature range is between -20°C to 70°C.
- Q: How often should I check the coolant pH value?
- A: It is recommended to check the coolant pH value periodically, ideally every few weeks, to ensure optimal performance.
Specification
Product Glance | Value |
---|---|
Model | S19e XP Hyd. |
Sub | 251T |
Version | 10 |
Crypto algorithm/coins | **SHA256 |
Typical hashrate, TH/s (1-1) | 251 |
Power on wall @35℃(1-2), Watt (1-1) | 5522 |
Power efficiency on wall@35℃(1-2), J/T (1-1) | 22 |
Detailed Characteristics | Value |
--- | --- |
Power supply
Phase| 3
Input voltage, Volt (2-1)| 380~415
Input frequency range, Hz| 50~60
Input max current, Amp| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (lengthwidthheight, w/o package), mm| 410170209
Server size (lengthwidthheight, with package), mm| 570316430
Net weight, kg| 12.8
Gross weight, kg| 14.1
Environment requirements
Inlet coolant temperature, °C| 20~50
Coolant flow, L/min| 8.0~10.0
Coolant pressure, bar| ≤3.5
Working Coolant (2-2)| Antifreeze/ Pure water/
Deionized water
Coolant pH value
| Antifreeze: 7.0~9.0 Prue water: 6.5~7.5
Deionized water : 8.5~9.5
Diameter of Coolant pipe connector, mm| OD10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Notes:
- The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power on wall and power efficiency on wall fluctuate by 5%.
- Inlet coolant temperature.
- Caution: Wrong input voltage may cause server damaged.
- For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
Performance Curve
- Hashrate vs. Inlet Coolant Temperature
- Power Efficiency vs. Inlet Coolant Temperature
(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.