UNI-T UT15C Digital Voltage Detector Instruction Manual
- August 13, 2024
- UNI-T
Table of Contents
UT15A/B/C
Operating Manual
Multifunction Voltage Testers
Introduction
Notice:
Please open battery cover and remove anti-leakage piece before using. (Refer
to content 3 instrument layout 13)
Thank you for purchasing a voltage tester. This tester has been designed in
accordance with the latest intemational safety standarde. The combivolt
testers are fully automatic voltage indicators capable of measuring AC/DC
voltage up to 690 V. Both units have visual and acoustic continuity
indication.
Constructed in accordance with IEC 65010 and IEC 61243-3
- Single pole phase indication
- 2 pole phasse rotation indication
- LED & LCD display (UT150)
Safety notices
This manual contains information that must be followed for operating the meter
safely and maintaining the meter in a safe operating condition. if this meter
is not used in the manner spected the protection provided may be impaired.
Waming Wams of potential, refer to the instruction manual to avoid
personal injury or damage to the meter.
Caution! Dangerous voltage. Danger of electical shock
Perfect display is only guaranteed within a temperature range of-10-50
relative humidity<85%.
Continuous double or reinforced insulation complies with IEC 536 class 11
CE Symbol of conformity, confirms conformity with relevant EU directives. The
meter complies with EMC directives (89/336/EEC) Specifically standards EN
50081-1 and EN 50082-1 as well as the Low Voltage Directive (73/23/EEC)
described in the standard EN 61010-1
The meter has been designed in accordance with the safety regulations for
electronic measuring instruments, EN 61010-1, IEC61010
Voltages above 75V DC or 50V AC may constitute a serious shock hastard
Before using the meter check for physical damage to the casing in particular
around the connectors. If the case is damaged do not use the mater
Check the test probes for damaged insulation or exposed metal Check the leads
for continulty
Do not apply more than the rated voltage, as marked on the meter between the
terminale in between any terminal and ground
Do not use or stare the meler in an environment of high temperature humidity,
fumes, vapour, gaseous, infarmmable and strong magnetic Belt. The performance
and safety of the instrument and the user may be compromised in such
circumstances
Desconnect croull power and discharge all nigh voltage capacitors before
testing resistance, continuity and diodes
Remove the batteries if the meter is not in use for a long period. Constantly
check the battery as it may have leaked Aleaking batery will damage the meter.
The meter may only be opened by a quarilled service technician for railbartion
and repa
Instrument Layout
- Test Probe (L1
- Test Probe (+) L2
- LED’s for voltage indication
- LED for single-pole best
- Right & Left LED phase rotation indication
- LED for cartruly
- LCD for voltage diaplay (only UT15C)
- Contact electrode for double-pole test of phass rotation and single-pole test
- Torch button on the back
- Poslive LED
- Negative LED
- Battery Compartment
- Anti-Heakage piece
Carrying out measurements
Perform a self test of the unst. Connect the two lest probes L1 and 12 The
continuity LED (6) will be it and an audible time should be heard.
Before any test check the unt on a known voltage source.
If the unit is defective it should be put out of service and returned to unt-
trend for repar.
Voltage test
Always hold the test probes by the handles behind the finger guards. Observe
the safety notices at all times.
An audible tone is present when an AC voltage and a negative DC voltage are
indicated.
The maximum switch on time is 30s. When this time has elapsed you must wait 10
minutes before retesting.
Connect probes to voltage source observing polarity of the test probes L2 is
positive probe, L1 is the negative probe.
For AC voltage the value is indicated on the LEDs (3) and on the LCD display
(UT15C only). The and LEDs are illuminated and buzzer is audible.
For DC voltage connect probe L2 to the positive terminal and L1 to the
negative terminal. The voltage is displayed on the LEDs and the LCD display
(UT15C only). The positive LED (10) is illuminated. If the polarity is
reversed the buzzer will sound. The negative LED (11) will be illuminated.
Single pote voltage detection
Perform a function test prior to this test.
This unit can be used as a single pole voltage detector when batteries are
inserted.
The single pole test is intended only as a quick check. The circuit must be
checked again for the presence of voltage using the two pole method.
Connect test probe L2 to the voltage source and keep finger on the contact
electrode (8). If an AC voltage above 100 V is present the LED (4) is
illuminated and the buzzer sounds.
The single pole test can be negatively affected by unfavour- able conditions
such as electrostatic field, good insulation etc.
Continuity test
The continuity test is only possible when batteries are inserted and in good
condition.
Ensure the circuit under test is not live.
Connect test probes L1 and L2 to the circuit. The continuity LED (6) will
illuminate and the buzzer will sound.
The unit indicate continuity below 400 Kohm
Phase rotation test
Perform a function test prior to this test.
This unit can determine the phase rotation within a three phase supply.
Connect test probe L2 to the supposed phase 2 and the test probe L1 to the
supposed phase 1. If the R LED illuminates the phases are in the correct
sequence 1 to 2.
Connect test probe L2 to the supposed phase 3 and test probe L1 to the
supposed phase 2. If the R LED illuminates the phases are in the correct
sequence 2 to 3. Connect test probe L2 to the supposed phase 1 and the test
probe L1 to the supposed phase 3. If the R LED illuminates the phases are in
the correct sequence 3 to 1.
During phase rotation test touch the contact electrode.
If the L LED illuminates then the phase sequence is anti clockwise.
Maintenance
Do not attempt to repair this unit. There are no user serviceable items in
this unit. Never attempt to open the casing apart from the battery cover.
Do not use the instrument if there is any physical damage to the case or test
leads.
The outside of the unit can be cleaned with a soft damp cloth only. Do not use
abrasive or chemical cleaning agents.
Changing batteries
Turn the battery cover by 90 degrees anti clockwise. Remove the cover and take
out spent batteries. Replace with 2 off 1.5V AAA (LR03) batteries, checking
the correct polarity.
Replace the battery cover and trun by 90° clockwise.
Spent batteries should be disposed of responsibly and with compliance with
current recycling and disposal regulations.
Calibration
The recommended calibration interval for the UT15A/UT15B/UT15C is 12 months.
Specifications
Voltage | UT15NUT15B | UT15C |
---|---|---|
Voltage display | 12 – 690 V AC/DC | 12 – 690 V AC/DC |
LED Resolution | 12,24,50,120,230 400.690 | 12,24,50,120,230 400.690 |
LCD Resolution | ( 12-690V AC/DC ) +/- 3 % + 8 digits | |
Voltage detection | automatic | automatic |
Acoustic signal | AC voltage – DC voltage | AC voltage – DC voltage |
Polarity detection | Full range | Full range |
Response time | LED < 0.1s | LED < 0.1s, LCD<2s |
Frequency range | 0 – 400 Hz | 0 – 400 Hz |
Peak Current | Is < 0.3A/is(after 5s) <3.5mA | Is < 0.3A/is(after 5s) <3.5mA |
Operation time | 30s | 30s |
Recovery time | 10 min | 10 min |
Auto power on | <12 V AC/DC | <12 V AC/DC |
Single Pole
voltage indication| |
---|---|---
Voltage range| 100 – 690 VAC| 100 – 690 VAC
Frequency range| 50 – 400 Hz| 50 – 400 Hz
Continuity
Measuring range| 1 0 – 400 Kohm| 0 – 400 Kohm
Phase rotation test
Voltage range| 100 – 690 V| 100 – 690 V
Frequency| 45 – 65 Hz| 45 – 65 Hz
Over voltage protection| 690 V AC/DC| 690 V AC/DC
Power supply| 2 x 1.5 LRO3 battery| 2 x 1.5 LRO3 battery
Dimensions| 255 x 70 x 28 mm| 255 x 70 x 28 mm
Weight| 200g| 200g
END
This opeating manual is subject to change without notice
UNI-T®
UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, China
Tel: (86-769) 8572 3888
http://www.uni-trend.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>