ROMGPEMG R470, R475 Electric Airless Sprayer Instruction Manual
- August 9, 2024
- ROMGPEMG
Table of Contents
Operating Instruction and Safety Manual
Electric Airless Sprayer
Model No.: R470 220V R475 120V
—For portable spray application of architectural paints and coatings
Important Safety Instructions:
Read all warnings and instructions in this manual. Save these instructions.
Warning
- Must be grounded: Read Grounding instructions. Use only grounded electrical outlets or Ground equipment and conductive objects in work area.
- Have heart problem or with heart pacemaker people, strictly prohibit to use this machine.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS
WARNING – When using tools, basic precautions should always be followed,
including the following:
a) SAVE THESE INSTRUCTIONS-To reduce the risks of fire or explosion,
electrical shock and injury to persons, read and understand all instructions
included in this manual. Be familiar with the controls and the proper usage of
the equipment.
b) WARNING-To reduce the risk of fire of explosion:
- Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.
- For units intended for use with only water-based materials-Do not spray or clean with flammable liquids. For use with water-based liquids only.
- For units intended for use with only water-based or mineral spirit-type materials with a minimum flash point of 21C°(69.8 F°) Do not spray on clean with liquids having a flash point less than 21C°(69.8 F°)
- aint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assemble, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use only conductive or grounded high-pressure airless paint sprayer hoses specified by the manufacturer.
- Verify that all containers and collection systems are grounded to prevent static discharge.
- Connect to a grounded outlet and use grounded extension cords. Do not use a 3 to 2 adapter.
- Do not use a paint or a solvent containing halogenated hydrocarbons. See operating instructions for examples of these types of materials.
- Keep spray area well ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.
- Do not smoke in the spray area.
- Do not operate light switches, engines, or similar spark producing products in the spray area.
- Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
- Know the contents of the paints and solvents being sprayed. Read all Material safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvent manufacturer’s safety instructions.
- Fire extinguisher equipment shall be present and working.
c) WARNING-To reduce the risk of skin injection.
- Do not aim the gun at, or spray any person or animal.
- Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.
- Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
- Only use a nozzle tip specified by the manufacturer.
- Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the manufacturer’s instructions for turning off the unit and relieving the pressure before removing the nozzle tip to clean.
- Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and relieve the pressure in accordance with the manufacturer’s instructions.
- High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, seek medical attention immediately.
- Check hose and parts for signs of damage. Replace and damaged hoses of parts.
- This system is capable or producing 22.7Mpa. Only use replacement parts or accessories that are specified by the manufacturer and that are rated a minimum of 22.8Mpa.
- Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
- Verify that all connections are secure before operating the unit.
- Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
d) WARNING-To reduce the risk of injury.
- Always wear appropriate gloves, eye protection, and a respirator or mask when painting.
- Do not operate or spray near children. Keep children away from equipment at all times.
- Don not overreach or stand on an unstable support. Keep effective footing and balance at all times.
- Stay alert and watch what you are doing.
- Do not operate the unit when fatigued or under the influence of drugs or alcohol.
- Do not kink or over-bend the hose.
- Do not expose the hose to temperatures or to pressures in excess of those specified by the manufacturer.
- Do not use the hose as a strength member to pull or lift the equipment.
- The Max. pressure of the air hose is 22.8Mpa, the normal pressure is 22.7Mpa
- The paint can be compatible: phenol aldehyde paint series, nitryl paint series, alkyd paint series, epoxy resin paint series, oxidized rubber paint series, latex paint series, water soluble paint series. The paint should be put in shade and dry place.
- Be aware of any hazards presented by the material being sprayed and consult the markings on the container or information supplied by the manufacturer of the material to be sprayed, including requirements for the use of personal protective equipment.
- Do not spray any material there the hazard is not know.
Technical Data
TYPE: | R470 | R475 |
---|---|---|
Power requirements | 230±10%Vac, 50±1Hz | 110±10%Vac, 60±1Hz |
Input power | 840W | 840W |
Maximum working pressure | 3300PSI | 3300PSI |
Sound pressure level: | 73.9 db | 73.9 db |
Vibration value: | 2.84 m/ss | 2.84 m/ss |
Maximum delivery gpm (lpm) | 2.1 | 2.1 |
Working environment temperature requirement: | 5℃~40℃ | 5℃~40℃ |
Working environment humidity requirement: | 30%~95% | 30%~95% |
Working environment altitude requirement: | £1000m | £1000m |
Transportation and storage temperature requirement: | 25℃~55℃ | 25℃~55℃ |
Dimensions Weight | 14.5kg | 14.5kg |
Warning
The following warnings are for the setup, use, grounding, maintenance and
repair of this equipment. The exclamation point symbol alerts you to a general
warning and the hazard symbol refers to procedure-specific risks. Refer back
to these warnings. Additional, product-specific warnings may be found
throughout the body of this manual where applicable.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or
explode. To help prevent fire and explosion:
- Use equipment only in well ventilated area.
- Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
- Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.
- Keep work area free of debris, including solvent, rags and gasoline.
- Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
- Ground equipment and conductive objects in work area. Read Grounding instructions.
- If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
- Keep a working fire extinguisher in the work area.
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
- Turn off and disconnect power cord before servicing equipment.
- Use only grounded electrical outlets.
- Use only 3-wire extension cords.
- Ensure ground prongs are intact on sprayer and extension cords.
- Do not expose to rain. Store indoors.
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce
skin. This may look like just a cut, but it is a serious injury that can
result in amputation. Get immediate surgical treatment.
- Do not point gun at anyone or at any part of the body.
- Do not put your hand over the spray tip.
- Do not stop or deflect leaks with your hand, body, glove, or rag.
- Engage trigger lock when not spraying.
- Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
WARING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
- Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. Read Technical Data in all equipment manuals.
- Use fluids and solvents that are compatible with equipment wetted parts. Read Technical Data in all equipment manuals.
- Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.
- Check equipment daily. Repair or replace worn or damaged parts immediately with manufactory replacement parts only.
- Do not alter or modify equipment.
- Use equipment only for its intended purpose. Call your distributor for information.
- Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
- Do not kink or over bend hoses or use hoses to pull equipment.
- Comply with all applicable safety regulations.
- Keep children and animals away from work area.
- Do not operate the equipment when fatigued or under the influence of drugs or alcohol.
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1, 1, 1-trichloroethane, ethylene chloride, other halogenated
hydrocarbon solvents or fluids containing such solvents in pressurized
aluminum equipment. Such use can cause serious chemical Reaction and equipment
rupture, and result in death, serious injury, and property damage.
BURN HAZARD
Equipment surfaces can become very hot during operation. To avoid severe
burns, do not touch hot equipment. Wait until equipment has cooled completely.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
- Keep clear of moving parts.
- Do not operate equipment with protective guards or covers removed.
- Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the
eyes or on skin, inhaled, or swallowed.
- Read warnings to know the specific hazards of the fluids you are using.
- Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or
when in the operating area of the equipment to help protect you from serious
injury, including eye injury, inhalation of toxic fumes, burns, and hearing
loss.
This equipment includes but is not limited to:
- Protective eye wear
- Clothing and respirator as recommended by the fluid and solvent manufacturer
- Gloves
- Hearing protection
Special Focus
A) Forbidden use of machines which are not designed for potentially explosive
atmospheres
B) Use of electrostatic atomizing and spraying equipment with machines not
specially designed for this equipment, because it may result in serious
hazards for the operators
C) Hazards resulting from contact with and/or breathing of toxic materials,
gases, mists and vapours which may be created by operation of the machine.
Such warnings shall also include such regarding the use of personal protective
equipment and reminding the user to be aware of the recommendations of the
coating material manufacturer;
D) Surface temperatures of any part of the machine, reachable during normal
operation, maintenance and servicing but not normally in contact with the
human body, which can exceed 48℃ or be less than 0℃.
E) Pressurised coating material and /or compressed air not to be directed
towards persons or animals;
F) Relating to training for the safe operation, adjustment, cleaning and
maintenance of the machine;
G) Regarding any special earthing measures;
H) Stating that a list of the materials used in the construction of the
machine will be made available on request to validate the compatibility with
the coating materials being used;
I) Regarding the requirements of using the machine only in a well ventilated
area with regards to health, fire and explosion risks;
J) Regarding the visually inspection for damage on hoses which may be
subjected to friction
K) Requirements for environmental protection to be observed
L) Reduce the quantity of coating and/or auxiliary materials at workplaces to
a minimum
Special Attention:
a) Maximum allowable pressure for the coating material……… 22.7 Mpa (3300psi)
b) Typical coating material flow rate for sample conditions: 2.1L/Min
c) Type and use of any safety devices in the machine:
- Temperature control device
- Maximum pressure control device
- Maximum electrical current control device
- Creepage protect control device
- Hand-hurt protect device
Component Identification
Number | Description | Function Introduction |
---|---|---|
01 | Pressure Adjust Knob | Control output pressure of Paint(Clockwise increase |
pressure, anticlockwise decrease pressure)
02| Electrical Switch| Control the sprayer on or off
03| Pressure Relief Valve| Horizontal direction means the paint operating
condition, Vertical direction means paint pressure relief condition
04| Fluid Outlet| Paint Output Tube
05| Suction Tube| Absorb the paint from the container to sprayer
06| Drain Hose| When pressure relief, the paint flow from this tube
INSTALLATION:
Grounding and Electric Requirements
Grounding Instructions
This product must be grounded. In the event of an eletrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for
the electric current. This product is equipped with a cord having a
groundingwire with an appropriate grounding plug . The plug must be plugged
into an outlet that is properly installed and grounded in accordance with all
local codes and orinances.
Improper installation of the grounding plug can result in a risk of electric
shock.
If repair or replacement of the cord or plug is necessary, do not connect the
green grounding wire to either flat blade terminal. The wire with insulation
having a green outer surface with or without yellow stripes is the grounding
wire and must be connected to the grounding pin. Check with a qualified
electrician or serviceman if the grounding instructions are not completely
understood, or if you are in doubt as to whether the product is properly
grounded. Do not modify the plug provided. If the plug will not fit the
outlet, have the proper outlet installed by a qualified electrican.
The sprayer cord includes a grounding wire with an appropriate grounding
contact.
The sprayer requires for type475:
100-120Vac, 50 Hz, 11A, 1 phase, circuit with a grounding receptacle The
sprayer requires for type 470:
220-240Vac, 50Hz,11A, 1 phase, circuit with a grounding receptacle.
Never use an outlet that is not grounded or an adapter.
Do not use the sprayer if the electrical cord has a damaged ground contact. Only use an extension cord with an undamaged ground contact.
Smaller gauge or longer extension cords may reduce sprayer performance.
Spray gun: ground through connection to a properly grounded fluid hose
and pump.
Fluid supply container : follow local code.
Solvent and Oil-based fluids: follow local code. Use only conductive
metal pails placed on a grounded surface such as concrete. Do not place the
pail on a nonconductive surface such as paper or cardboard, which interrupts
grounding continuity.
Grounding the metal pail: Connect a ground wire to the pail by clamping
one end to pail and other end to ground such as a water pipe.
To maintain grounding continuity when flushing or relieving pressure: hold
metal part of the spray gun firmly to the side of a grounded metal pail, then
trigger the gun.
Locking and Unlocking the Spray Gun:
Always lock the trigger off when attaching the spray tip or when thr spray gun
is not in use.
Locking the Spray Gun
The gun is secured when
the trigger lock is at a 90° angle(perpendicular) to the trigger in either
direction Applicable for wall painting paint, clean with water.
Unlocking the Spray Gun
To unlock the gun,turn the trigger lock to be in the line with trigger
Electrical bonding
A hose, hose assembly, and spray gun assembly shall be constructed to provide
electrical bonding to dissipate static electricity from the tip of the Spray
gun through the spray gun assembly and the couplings at the ends of the hose
to the pump assembly. The spray gun assembly shall also provide an external
means to dissipate static electricity during the cleaning process when
spraying into a metal container.
Construction
Black hose is constructed of an extruded, seamless themoplastic inner tube,
chemically bonded to multi-layers of high tensile synthetic resistant
polyurethane cover. A static drain element of flexible, electrically
conductive material is located between the braid layers.
FEATURES
- Polyurethane cover permits greater flexibility and tighter bends
- Resistant to flex fatigue
- Dissipates static charge
- Will not swell or degrade in contact with most paint chemicals, oils and most other solvents
- Light weight- approximately half that of comparable rubber or wire hose
- O.D smaller than comparable rubber hose without reducing the I.D., pressure rating, or fluid-carrying capacity
- Highly abrasion resistant
- Extrmely durable
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever you are instructed to
relieve pressure, stop spraying, check or service equipment or install or
clean spray tip.
- Turn OFF power and turn pressure control to lowest pressure setting.
- Hold gun against side of grounded metal flushing pail. Trigger gun to relieve pressure.
- Turn prime valve down. Our pressure relief should by operate by hand.
- If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction.
- Engage trigger safety lock on gun if unit is being shut down or left unattended.
Opearating Instructions
BEFORE STARTING
- CHECK all fittings and connections in the pump system, hose, and gun to ensure that they are tight. CHECK to ensure that there is a spray tip in the gun, and that the tip is the correct size for the coating you are to spray. (There are various tips available, for each type of coating or configuration.)
- MAKE SURE the power source is securely grounded and match the motor rating of your sprayer.
- New spray: Oil is used by the factory for testing and protection. It is necessary to flush unit before spraying. Clean the pump with warm soapy water, Make sure the hydraulic oil in the pump is clean and sufficient in volume then begin the following procedure
1. Remove spray tip from gun
2. Put the input hose and pressure relief tube into the bucket with some water,
3. Turn on the motor and push the pressure valve upright. In a few seconds, water will begin to flow up through the tube and flow out from outlet valve, tighten the outlet valve deasil, then tighten the pressure valve deasil.
4. When the pressure reaches up to around 227bar, check if there is any leakage on the outlet hose, if it’s leak, Please check. Don’t stop or deflect leaks with your hand, body, glove or rag.
5. If doesn’t leak, open the spray gun and have a testing spray. Clean the oil in pump. Change the soapy water and use clean water when the spray is clean
6. Turn off power, Continue to spray till no water out.
7. Unlock trigger lock. Put the pressure valve upright, till no soapy water in pump
Operation
Setup
WARNING
Make sure sparayer is turned off and unplugged from power source.
Connect Gun to Sprayer
- Connect supply hose to sprayer fluid outlet.
- Connect other end of supply hose to gun swivel. Use wrenches to tighten all connections securely.
Installing tip and guard on gun
WARNING
- If equipment has recently been operated, Relieve pressure.Set trigger lock
- Using a pencil or similar object, Insert seal into back of guard.
- Install guard over end of gun
- Insert tip in guard.Tighten retaining nut.
Operation Spraying
- Unlock trigger lock
- Be sure the tip faces forward spray.
- Hold gun perpendicular and approximately 12 inches (304mm) from surface.Move gun first, Then pull gun trigger to spray a test pattern.
- Slowly increase pump pressure until coverage is uniform
Aligning Spray
- Relieve pressure. Set trigger lock
- Loosen guard Horizontal Vertical retaining nut
- Align guard horizontally to spray a horizontal pattern.
- Align guard vertically to spray a vertical pattern.
Spray instruction
CHECK to ensure that the shipping seal has been removed from under the cap on
the hydraulic tank.
Hydraulic tank should be at least 3/4 full of hydraulic fluid.
- During paint spraying, hold the gun upright to the surface of paint-object and keep a constant spraying distance of 350~400mm. (Fig.4)
- Move gun before starting the trigger. Equably move gun when spraying. At last, loosen the trigger and stop moving immediately. Adjust moving speed according to thickness of paint, spray pressure and the distance of gun to object.
- In order to get an intact and slick surface, spray from level and vertical respectively. Spraying time will be variable with different paints. Spray for second time when the first painting is dry.
- During your spraying if you need to stop for several minutes, loosen the pressure valve and revolve prime valve in counter-clockwise, then shut the motor. Put spraying tip into solution in case of paint block-up in the spraying tip.
Airless Sprayer Cleaning Procedure
When spraying tip is block-up, revolve it 180 degree for several times, then
move back in position of well-spraying.
Step 1: Engage trigger safety lock on gun. Revolve 180 degree
Step 2: Turn off pump and release fluid pressure by turning the pressure
relief prime valve located on the engage trigger safety lock on gun. side of
the pump down.
Step 3: Engage trigger safety lock on gun, Revolve 180 degree then open
the safety lock.
Pressure release procedure
Whenever instructed to relieve pressure, Stop spraying, Check or service
equipment or install or clean spray tip.
- Engage trigger safety lock on gun. Turn Off power and turn sprayer pressure control to lowest pressure setting.
- Hold gun against side of flushing pail. Trigger gun into pail to relieve pressure.
- Turn off pump and release fluid pressure by turning the pressure relief prime valve located on the side of the pump down.
Daily Maintain
Equipment lifetime is rely on daily maintain. The following respects should be
obeyed:
- Read the Manual carefully before first using.
- Check the electrical requirement before each working.
- Thorough cleaning equipment and the accessories after using.
- Coil the tube after cleaning, in case of any damage.
- Add some lubricant if long time not use
General Repair Information
Flammable materials spilled on hot, bare, motor could cause fire or explosion. To reduce risk of burns,fire or explosion, do not operate sprayer with coverremoved.
- Keep all screws, nuts, washers, gaskets, and electrical fittings removed during repair procedures. These parts usually are not provided with replacement kits.
- Test repairs after problems are corrected.
- If sprayer does not operate properly, review repair procedure to verify you did it correctly. See Troubleshooting, page 8.
- Overspray may build up in the air passages. Remove any overspray and residue from air passages and openings in the enclosures whenever you service sprayer.
- Do not operate the sprayer without the motor shroud in place. Replace if damaged. Motor shroud directs cooling air around motor to prevent overheating and insulates the control board from accidental electric shock.
To reduce risk of serious injury, including electric shock:
- Do not touch moving or electric parts with fingers or tools while testing repair.
- Unplug sprayer when power is not required for testing.
- Install all covers, gaskets, screws and washers before you operate sprayer.
CAUTION
- Do not run sprayer dry for more than 30 seconds. Doing so could damage pump packings.
- Protect the internal drive parts of this sprayer from water. Openings in the cover allow for air cooling of the mechanical parts and electronics inside. If water gets in these openings, the sprayer could malfunction or be permanently damaged.
- Prevent pump corrosion and damage from freezing. Never leave water or water-base paint in sprayer when its not in use in cold weather. Freezing fluids can seriously damage sprayer. Store sprayer with Pump Armor to protect sprayer during storage.
Troubleshooting
- Common Problem of Equipment
Problem| What To Check
(If check is OK, go to next check)| What To Do
(When check is not OK, refer to this column)
---|---|---
Motor Won’t Operate
Basic Fluid Pressure| 1. Pressure control knob setting. Motor will not run if
set at minimum (fully counter-clockwise).| 1.Slowly increase pressure setting
to see if motor starts
2. Spray tip or fluid filter may be clogged.| 2.Relieve pressure ,then Then
clear clog or clean gun filter
Basic Mechanical| 1. Pump frozen or hardened paint| 1.Thaw sprayer if water
or water-based paint has frozen in sprayer. Place sprayer in warm area to
thaw. Do not start sprayer until thawed completely. If paint hardened (dried)
in sprayer, replace pump packings.
2. Displacement pump connecting rod pin. Pin must be completely pushed into
connecting rod and retaining spring must be firmly ingroove or pump pin.| 2.
Push pin into place and secure with spring retainer.
3. Motor. Remove drive housing assembly.| 3. Replace motor if fan won’t
turn.
Low Output| 1. Worn spray tip.| 1.Relieve pressure, Replace tip
2. Verify pump does not continue to stroke when gun trigger is released.| 2.
Service pump.
3. Prime valve leaking.| 3. Relieve pressure, Then repair prime valve.
4. Suction tube connections| 4. Tighten any loose connections. Check o-ring
on suction tube.
5. Electric supply with volt meter. Meter must read 220-240 Vac. Low voltages
reduce sprayer performance.| 5. Reset building circuit breaker; replace
building fuse. Repair electrical outlet or try another outlet.
6. Extension cord size and length.| 6. Replace with a correct, grounded
extension cord.
7. Leads from motor to circuit board for damaged or loose wire connectors.
Inspect wiring insulation and terminals for signs of overheating.| 7. Be sure
male terminal pins are centered and firmly connected to female terminals.
Replace any loose terminals
or damaged wiring. Securely reconnect terminals.
8. Worn motor brushes which must be greater than 1/4 in. (6 mm).| 8. Replace
brushes.
9. Motor brushes binding in brush holders.| 9. Clean brush holders. Remove
carbon dust by using compressed air to blow out brush dust.
10. Low stall pressure. Turn pressure control knob fully clockwise.| 10.
Replace pressure control assembly.
11. Motor armature for shorts by using an armature tester (growler) or
perform spin test,| 11. Replace motor
Explode view
No.
| Description| Qty.| No.| Description| Qty.| No.| Description|
Qty.
---|---|---|---|---|---|---|---|---
1| Filter assembly| 1| 50| Powder metallurgy gear shaft collar| 2| 100|
O-Rings(27×2.4)| 1
2| Ribbon| 1| 51| Gear shaft| 1| 101| Cap| 1
3| Feed pipe bending| 3| 52| Pinion| 1| 102| Allen flat end set screws M3X10|
2
4| cutting ferrule| 1| 53| Bent axle| 1| 103| Deflating cap| 1
5| Feeding hose| 1| 54| Crankshaft gear| 1| 104| Micro switch cover| 1
6| Pressure release tube| 1| 55| Retaining ring in the powder metallurgy| 1|
105| Adjust seat| 1
7| Pressure release tube locking ring components| 1| 56| Gear shaft collar| 1|
106| Micro switch components+Casing| 1
8| Hose hoops| 1| 57| Crank shaft collar| 1| 107| Pressure spring| 1
9| Feed pipe bending contact| 1| 58| Open punching needle roller bearing| 1|
108| Spring hat| 1
10| O-Rings 19*2.65| 2| 59| Straight pin| 2| 109| Pressure adjusting screw| 1
11| Feed pipe bending clasp| 1| 60| Motor cabinet| 1| 110| Regulating sleeve|
1
12| Pump body fixed nut| 1| 61| Wave spring washers| 1| 111| Filter holder| 1
13| The plunger rod lock nut| 1| 62| Single-row radial ball bearing| 1| 112|
Filter net| 1
14| The plunger rod lock nut liner| 1| **** 63-64| Motor assembly| 1| 113|
Filter element| 1
15| The little ring| 1| 65| Single row radial ball bearing| 1| 114| O-Rings
24.3X1.8| 1
16| Discharge joint| 2| 66| Motor stator components| 1| 115| A filter element
knob| 1
17| Pump body| 1| 67| Motor parameter data| 1| 116| Plastic spacer| 1
18| Large Sealing Packing Ring| 1| 68| Carbon brusf seat| 1| 117| Screw seat
insert| 1
19| The plunger rod guide sleeve| 1| 69| Carbon brush cover| 2| 118| Pressure
relief valve seat| 1
20| Rectangular Seal Ring| 1| 70| The motor back cover seat| 1| 119| Plastic
ring| 1
21| Steel ball seat| 1| 71| Homemade bolt| 2| 120| O-Rings 5X1.8| 1
22| Feed valve ball| 1| 72| plain washer 6| 2| 121| Pressure relief valve
stem+4.5 Carbide Ball| 1
23| Feed valve plates| 1| 73| locking nut M6| 2| 122| Pressure relief valve
spring| 1
24| Feeding seat sealing| 1| 74| Blade| 1| 123| Spring seat| 1
25| Feeding seat| 1| 75| Split damping ring| 1| 124| Elastic cylindrical pin
3X8| 1
26| The plunger rod valve lock nut| 1| 76| The motor back cover| 1| 125|
Switch seat| 1
27| Squirrel cage gasket| 1| 77| Cross pan head self-drilling screw
ST3.5X10
| 3| 126| Switches knob| 1
28| Plunger rod valve plates| 1| 78| Control circuit device| 1| 127| Straight
pin A2.5X25| 1
29| Steel ball| 1| 79| Cross pan head self-drilling screw ST4.8X20| 1| 128|
Pressure aluminium joint| 1
30| Mouse cage| 1| 80| shell(Silver sand grain63358)| 1| 129| Plastic cup| 1
31| Plunger lever| 1| 81| The power cord fixing seat| 1| 130| Rack pads| 4
---|---|---|---|---|---|---|---|---
32| The piston locking collar| 1| 82| Power Plugs| 1| 131| Pump seat assembly|
1
33| Piston| 1| 83| The handle cushion| 1| 132| Pressure gauge(Rc1/4 contact)|
1
34| Connecting rod| 1| 84| handle| 1| 133| Internal tooth lock washer| 2
35| Axis Guide| 1| 85| The handle sheath| 1| 134| plain washer| 1
36| Straight pin| 1| 86| Heat sink| 1| 135| spring washer| 1
37| Straight pin| 1| 87| Circuit board assembly| 1| 136| Philips small
head screw M4X12| 1
38| Bearing (porous oil hole)| 1| 88| cross recess pan head screw(M4X20)| 2|
Packing accessories
39| Stamping needle bearing| 1| 89| locknut(M4)| 1| 137| wrench| 1
40| Flat washer| 2| 90| Plain washer| 1| 138| High pressure spray gun| 1
41| Cross Recess Head Screw| 10| 91| Hexagon socket cap screws| 1| 139|
description| 1
42| Pump body cover| 1| 92| Transporting pipe components| 1| 140| High-voltage
paint(7.6m black)| 1
43| Dust Stop block| 1| 93| O-Rings| 1| 141| Oil cup| 1
44| Bolt| 10| 94| Regulator connection| 1| 142| LOGO label| 1
45| spring washer| 7| 95| Lock sleeve| 1| 143| The warning label| 1
46| Gear box| 1| 96| White seal| 1| 144| Parameters of the labeling| 1
47| INA Open punching needle roller bearing| 2| 97| Strengthen the seal| 1|
145| Regulating labeling| 1
48| INA Open punching needle bearing unilateral lip seal| 1| 98| Switch lever|
1| | |
49| Powder metallurgy big ring| 1| 99| O-Rings(8.8×1.9)| 1| | |
Sealing ring replace:
Warning
Before the repair, please be sure to determine the equipment fault, otherwise
the unnecessary dismantling of equipment will seriously affect the function of
the equipment and greatly shorten the service life of equipment.
- Remove Pump’s front cover.
- Use a special tool to take out the plunger rod connecting pin
- Lose the cap
- Unscrew the pump body components,separately on the pump body and feedstock block.
- Take out the plunger rod in the opposite direction,take out the ring size
- In the size of ring outer ring, with a little grease; Press the ring into the pump body
- Press the plunger rod into the pump body
- Put Into the pump body components according to the disassembly sequence.
R470 Airless Sprayer Electrical Installation Drawing
R475 Airless Sprayer Electrical Installation Drawing
Accessory List
- Left Secondary Frame (With Handle Grip) 1PCS
- Right Secondary Frame (With Handle Grip) 1PCS
- White Seal Washer 3PCS
- Black Seal Washer 2PCS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>