FLExLIGHT KSE-LIGHTS Hand Lamp Instruction Manual
- August 7, 2024
- FLEXLIGHT
Table of Contents
FLExLIGHT KSE-LIGHTS Hand Lamp
Product Specifications
- Brand: FLExLIGHT
- Model: FL-EX-01
- Light Output: 1600/500 lumens
- Color Temperature: 6500 Kelvin
- Features
- Freely pivotable light output
- Telescopic arm
- Folding mechanism
- Charging port
- On-/off-button
- Handle
Product Usage Instructions
First Use
Check the environmental conditions before use to ensure compliance with the
light’s label. Avoid using the light if it is damaged. Assemble the light by
tilting the mast to the horizontal position, sliding it into the locking
mechanism, and tightening the hand screws.
Operating the Light
To turn on the light, press the on/off button on the back of the lamp head.
Press once for power mode (1600 lumens), again for work mode (500 lumens), and
once more to turn off the light. For flashing mode, press and hold the button
for 6 seconds when the light is off.
Battery Level
The light will flash every 10 minutes in the last 30 minutes of battery
life to indicate a low battery level. Continuous flashing will occur in the
last 5 minutes.
Charging
To charge the light, insert the blue charging plug into the blue charging
socket, turn the locking ring, and connect the charger to a power source.
Different flashing patterns indicate pre-charging, fast charging, and fully
charged status.
Safety Instructions
Do not use damaged lamps, chargers, or power sockets. Only use original
KSE-LIGHTS chargers to avoid negative effects on product life. KSE-LIGHTS is
not liable for consequential damage due to unauthorized parts usage.
FAQ
-
Q: How can I tell when the battery is low?
- A: The light will flash every 10 minutes in the last 30 minutes of battery life.
-
Q: Can I use a different charger to charge the light?
- A: It is recommended to only use original KSE-LIGHTS chargers to maintain product integrity and performance.
KSE-LIGHTS
be tough – be tough – be different
ANLEITUNG MANUAL
ROOM LAMP
FL-EX-01
1600/500Lumen
POWER-/ work light
125° beam angle
5/10 hours
6500 Kelvin
<7 hours charging
The product complies with the following standards
- 60079-0 :2018 IEC 60079-0:2017
- EN 60079-11:2012 IEC 60079-11:2011
- ANSI/UL 913-2019 Ed.8
- ANSI/UL 60079-0-2019
- ANSI/UL 60079-11-2018
UL 1576
- CAN/CSA C22.2 NO. 60079-0:19
- CAN/CSA C22.2 NO. 60079-11:14
- CSA C22.2 No. 250.4-14
- CSANe 20ATEX 2257X
- IECEx SIR 20.0048X
- CSA 21CA80055002X
Special conditions for use in the Ex-atmosphere
- The hand lamp can be used in an extended ambient temperature of -15 °C to +50 °C
- Damaged equipment must be taken out of service immediately and out of potentially explosive atmosphere.
- The hand lamp may only be charged outside the hazardous area using the appropriate charger.
- The light window must never be completely covered during operation in a potentially hazardous area.
6 sec. for flashing mode
IP65
7 kilograms
80% capacity after 800 cycles
FIRST USE
Check before use
Check that the environmental conditions comply with the conditions on the
light‘s label. The end user is responsible for contact with possible chemicals
and the housing. Never use the light if it is technically or physically
damaged. The housing and the lifting lever are made of aluminum and pose a
risk of ignition in the event of mechanical impact or friction. Aged or
chipped seals must be replaced to meet the requirements of the Ex
certification and the IP code.
Assembly
- Tilt the mast to the horizontal end position and allow it to slide down a little so that it slides into the locking mechanism (illustration below). Tighten the lower hand screw. Raise the mast to the desired working height and tighten the upper hand screw.
- For dismantling, the process is simply carried out in reverse.
Light
Press the on/off button on the back of the lamp head (right button). Power
mode switches on (1600 lumens). Press again for work mode (500 lumens). Press
again to switch the light off. For flashing mode, press and hold the button
for 6 seconds when switched off. The light now flashes in power mode (1600
lumens). Press again to make the light flash in work mode (500 lumens). Press
again to switch the light off.
Battery level
The light starts to flash every 10 minutes for the last 30 minutes to signal a
low battery level. In the last 5 minutes the light will flash constantly.
Charging
- Insert the blue charging plug into the blue charging socket. Turn the locking ring. Connect the charger to a suitable power source.
- Slow, yellow flashing: Pre-charging.
- Fast, green flashing: Fast charging
- Slow, green flashing: fully charged (maintenance) Steady green light: fully charged
SAFETY INFORMATIONS
- Never use the light or the charger if they are physically or technically damaged. Never switch on the light if the light emission window is covered, dirty or damaged.
- Never charge the light in hazardous areas. Do not use the light while it is charging. Only use approved chargers. Maximum charging voltage Um = 16V.
- If the product is no longer technically usable, dispose of the battery at a recycling facility or return it to the dealer.
- To ensure gentle handling of the battery, it should be charged for the first time until the green LED lights up constantly. This should also be taken into account for the first 10 charging cycles.
- The light should only be charged within a temperature range of 0°C to 40°C. Use is only intended from -20°C to 40°C. Store the light at -10°C to 40°C and a humidity of <95%.
- The explosion protection only applies when using the original rechargeable battery. When replacing, only the certified EPC rechargeable battery for this model should be used.
Declaration of Conformity
- according to directive 2014/34/EU (ATEX directive)
- according to directive 2014/35/EU (LVD directive)
- according to directive 2014/30/EU (EMC directive)
- Manufacturer: Dongguan Pan American Electronics Co., Ltd.
- Distributor: KSE-LIGHTS GmbH
- Address: Thüngenfeld 8, 58256 Ennepetal, Germany
- Product: LED flood light
- Types: FL-EX-01 (EX-MV01)
- Description: Mobile LED floodlight.
It includes a rechargeable battery and a switchable LED light panel.
- EU-Type Examination Certificate: CSANe 20ATEX2257X
- Marking: II 1G Ex ia IIC T4 Ga 0 °C ≤Ta ≤ 40 °C
Issuer of EU-type examination certificate:
CSA Group Netherlands B.V., Utrechtseweg 310, Building B42, 6812AR Arnhem,
Netherlands
-
Applied standards for ATEX directive
EN IEC 60079-0:2018
EN 60079-11:2012 -
Applied standards for LVD directive
EN IEC 60598-1:2021+A11:2022
EN 60598-2-4:2018 -
Applied standards for EMC directive
EN 55015:2019+A11:2020
EN IEC 61000-3-2:2019/A1:2021
EN 61000-3-3:2013 /A2:2021
EN 61547:2009
KSE-LIGHTS GmbH
Ennepetal, 24.11.2023
Signature
Nikolai Seel (General management)
- This declaration certifies compliance with the indicated directives but implies no assurance of properties.
- The safety of the product information should be observed. This statement turns off automatically whenever changes are made to the product, that have not been matched with the company KSE-LIGHTS GmbH.
KSE-LIGHTS GmbH
- Thüngenfeld 8 58256
- Ennepetal Germany
- Tel: +49 (0)2333-98247 30
- Fax: +49 (0)2333-98247 49
- www.kse-lights.com
- info@kse-lights.com
SAFETY INFORMATIONS
Do not use damaged lamps, chargers or power sockets to charge the lamp. Do not
pull the power cord to remove the AC adapter. Only use original KSE-LIGHTS
chargers. The use of other chargers may have a negative effect on the life of
the product. KSE-LIGHTS is not liable for consequential damage if parts are
used which are not approved by KSE-LIGHTS.
Protect the charger and the accumulator from damage.
Never charge the product outside the approved temperature range from 0°C to
+40°C.
The supply voltage of the charger can be provided by one of the following measures according to IEC 60079-14
- where Um does not exceed 50 V AC or 120 V DC, in a SELV or PELV system
- via a safety isolating transformer complying with the requirements of IEC 61558-2-6 or a technically equivalent standard
- directly connected to apparatus complying with the IEC 60950 series, IEC 61010-1 or a technically equivalent standard
- fed directly from cells or batteries
Thüngenfeld 8 58256 Ennepetal Germany
- +49 (0)2333 982 47 30
- www.shop.kse-lights.com
- www.kse-lights.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>