FLEXLIGHT FL-EX-01 Hand Lamp Instruction Manual

June 16, 2024
FLEXLIGHT

FLEXLIGHT FL-EX-01 Hand Lamp

FLEXLIGHT FL-EX-01 Hand Lamp

The product complies with the following standards:

EN 60079-0 :2018 IEC 60079-0:2017
EN 60079-11:2012 IEC 60079-11:2011
ANSI/UL 913-2019 Ed.8
ANSI/UL 60079-0-2019
ANSI/UL 60079-11-2018
UL 1576

CAN/CSA C22.2 NO. 60079-0:19
CAN/CSA C22.2 NO. 60079-11:14
CSA C22.2 No. 250.4-14

CSANe 20ATEX 2257X
IECEx SIR 20.0048X
CSA 21CA80055002X

FLEXLIGHT FL-EX-01 Hand Lamp 1

FLEXLIGHT FL-EX-01 Hand Lamp 2

Special conditions for use in the Ex-atmosphere

  1. The hand lamp can be used in an extended ambient temperature of -15 °C to +50 °C
  2. Damaged equipment must be taken out of service immediately and out of potentially explosive atmosphere.
  3. The hand lamp may only be charged outside the hazardous area using the appropriate charger.
  4. The light window must never be completely covered during operation in a potentially hazardous area.

FIRST USE

Check before use:
Check that the environmental conditions comply with the conditions on the light‘s label. The end user is responsible for contact with possible chemicals and the housing. Never use the light if it is technically or physically damaged. The housing and the lifting lever are made of aluminum and pose a risk of ignition in the event of mechanical impact or friction. Aged or chipped seals must be replaced to meet the requirements of the Ex certification and the IP code.

Assembly:
Tilt the mast to the horizontal end position and allow it to slide down a little so that it slides into the locking mechanism (illustration below). Tighten the lower hand screw. Raise the mast to the desired working height and tighten the upper hand screw.
For dismantling, the process is simply carried out in reverse.

Light:
Press the on/off button on the back of the lamp head
(right button). Power mode switches on (1600 lumens). Press again for work mode (500 lumens). Press again to switch the light off. For flashing mode, press and hold the button for 6 seconds when switched off. The light now flashes in power mode (1600 lumens). Press again to make the light flash in work mode (500 lumens). Press again to switch the light off.

Battery level:
The light starts to flash every 10 minutes for the last 30 minutes to signal a low battery level. In the last 5 minutes the light will flash constantly.

Charging:
Insert the blue charging plug into the blue charging socket. Turn the locking ring. Connect the charger to a suitable power source.

  • Slow, yellow flashing: Pre-charging.
  • Fast, green flashing: Fast charging
  • Slow, green flashing: fully charged (maintenance)
  • Steady green light: fully charged

FLEXLIGHT FL-EX-01 Hand Lamp 3

SAFETY INFORMATION

  • Never use the light or the charger if they are physically or technically damaged. Never switch on the light if the light emission window is covered, dirty or damaged.
  • Never charge the light in hazardous areas. Do not use the light while it is charging. Only use approved chargers. Maximum charging voltage Um = 16V.
  • If the product is no longer technically usable, dispose of the battery at a recycling facility or return it to the dealer.
  • To ensure gentle handling of the battery, it should be charged for the first time until the green LED lights up constantly. This should also be taken into account for the first 10 charging cycles.
  • The light should only be charged within a temperature range of 0°C to 40°C. Use is only intended from -20°C to 40°C. Store the light at -10°C to 40°C and a humidity of <95%.
  • The explosion protection only applies when using the original rechargeable battery. When replacing, only the certified EPC rechargeable battery for this model should be used.

FLEXLIGHT FL-EX-01 Hand Lamp 4 FLEXLIGHT FL-
EX-01 Hand Lamp 5

Do not use damaged lamps, chargers or power sockets to charge the lamp. Do not pull the power cord to remove the AC adapter. Only use original KSE-LIGHTS chargers. The use of other chargers may have a negative effect on the life of the product. KSE-LIGHTS is not liable for consequential damage if parts are used which are not approved by KSE-LIGHTS.

Protect the charger and the accumulator from damage.
Never charge the product outside the approved temperature range from 0°C to +40°C.
The supply voltage of the charger can be provided by one of the following measures according to IEC 60079-14:

  • where Um does not exceed 50 V AC or 120 V DC, in a SELV or PELV system
  • via a safety isolating transformer com-plying with the requirements of IEC 61558-2-6 or a technically equivalent standard
  • directly connected to apparatus complying with the IEC 60950 series, IEC 61010-1 or a technically equivalent standard
  • fed directly from cells or batteries

Declaration of Conformity

  • according to directive 2014/34/EU (ATEX directive)
  • according to directive 2014/35/EU (LVD directive)
  • according to directive 2014/30/EU (EMC directive)

Manufacturer : Dongguan Pan American Electronics Co., Ltd.
Distributor : KSE-LIGHTS GmbH
Address : Thüngenfeld 8, 58256 Ennepetal, Germany
Product : LED flood light
Types : FL-EX-01 (EX-MV01)
Description : Mobile LED floodlight.
It includes a rechargeable battery and a switchable LED light panel.
EU-Type Examination Certificate: CSANe 20ATEX2257X
Marking : II 1G Ex ia IIC T4 Ga

+49 (0)2333 982 47 30
www.shop.kse-lights.com
www.kse-lights.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals