PEDROLLO MC Series Submersible Pumps Owner’s Manual

August 6, 2024
pedrollo

PEDROLLO MC Series Submersible Pumps

Specifications

  • Product: MC Submersible pumps
  • Materials: Cast iron
  • Performance: Two-channel impellers
  • Applications: Sewage, wastewater, sludge, mixed water, etc.

Product Usage Instructions

Installation and Use

The MC series submersible pumps are constructed from thick cast iron, ensuring robustness and longevity. They feature two-channel impellers designed to drain liquids containing suspended solids and short fibers, suitable for various applications like sewers, tunnels, and underground facilities.

Application Limits

Ensure the power cable is appropriately sized for installation.
The pumps can handle sewage, wastewater, sludge, mixed water,activated sludge, and more.

Included Components

  • Power cable length: 10m
  • Float switch (single-phase models only)
  • Switchbox compatible with single-phase versions

Warranty Information
For three-phase models, the warranty remains valid if the motor’s thermal protector is correctly connected to the control panel.

FAQ

Q: What are the available voltage requirements for the pumps?
A: Different voltage requirements are available upon request, including 60 Hz frequency.

Q: What components are included with the pumps?
A: The pumps come with a power cable, float switch (for single-phase models), and a switchbox compatible with single-phase versions.

High-quality materials and robust construction ensure superior performance and reliability

PERFORMANCE RANGE

  • Flow rate up to 1600 l/min (96 m3/h)
  • Head up to 25 m

INSTALLATION AND USE

The MC deries is constructed from thick cast iron, offering exceptional robustness, abrasion resistance, and longevity.
Featuring TWO-CHANNEL impellers, these pumps are designed to drain liquids containing suspended solids and short fibers, as well as sewage, wastewater, sludgemixed water, activated and putrid sludge.
They are suitable for a wide range of applications, including sewers, tunnels, excavations, canals, and underground parking facilities

APPLICATION LIMITS

  • Depth below water level up to 10 m (with an appropriately sized power cable)
  • Liquid temperature up to +40 °C
  • Suspended solids transfer:
    • up to Ø 50 mm for MC /50
    • up to Ø 65 mm for MC /65
  • Minimum immersion for continuous service:
    • 320 mm for MC /50
    • 360 mm for MC /65

INCLUDES

  • Power cable length 10 m
  • Float switch (exclusive to single-phase models)
  • Switchbox compatible with single-phase versions

AVAILABLE UPON REQUEST

  • QES control panel for three-phase pumps
  • Different voltage requirements 60 Hz frequency

WARRANTY

  • The warranty for three-phase models remains valid only if the motor’s built-in thermal protector is properly connected to the control panel. This connection is essential for the warranty’s applicability.

PATENTS – TRADE MARKS – MODELS

  • Patent No. IT0001428923
  • Registered Community Model No. 008625685-0001,No. 008625685-0002

CURVES AND PERFORMANCE DATA

ABSORPTION

TYPE

Single- phase

| VOLTAGE

230 V

---|---
MCm 15/50| 10.5 A
MCm 20/50| 14.0 A
MCm 30/50| 18.0 A
MCm 30/65| 14.0 A
TYPE

Three- phase

| VOLTAGE

400 V

---|---
MC 15/50| 4.5 A
MC 20/50| 5.0 A
MC 30/50| 6.5 A
MC 40/50| 7.0 A
MC 30/65| 6.5 A
MC 40/65| 7.5 A

DIMENSIONS AND WEIGHT

TYPE| PORT

DN

| Passage of solid bodies| DIMENSIONS mm| kg
---|---|---|---|---
Single- phase| Three- phase| a| b| c| h| h1| d| e| f| p| **| 1~| 3~
MCm 15/50| MC 15/50| **

2½”

| ****

50 mm

| ****


162

| ****


119

| ****


212

| ****

487

| ****


167

| ****


242

| ****


75

| adjustable| ****



800

| ****



800

| 42.0| 40.0
MCm 20/50| MC 20/50| 43.0| 41.9
MCm 30/50| MC 30/50| 513 | 487| 47.8| 44.0
| MC 40/50| 513| –| 47.8
MCm 30/65| MC 30/65| 3″| 65 mm| ****

180

| ****

120

| ****

240

| 547 | 521| ****

201

| ****

246

| ****

85

| 50.0| 46.0
| MC 40/65| 547| –| 49.8

PALLET CAPACITY

TYPE NO. OF PUMPS
Single-phase Three- phase
MCm 15/50 MC 15/50
MCm 20/50 MC 20/50
MCm 30/50 MC 30/50
MC 40/50
MCm 30/65 MC 30/65
MC 40/65

MATERIALS AND COMPONENTS

OPTIONAL – Support base
(Cod. ASSBAVM)

Power switchboard
(standard for single-phase versions)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals