AcraDyne Gen IV Controller User Guide

August 5, 2024
AcraDyne

AcraDyne Gen IV Controller

Specifications

  • Controller: Gen IV
  • Cable Length: Not to exceed 20m
  • Grounding: Redundant Earth ground required

Product Usage Instructions

Step 1: Make Connections

  • A. Connect the tool cable to the Gen IV Controller. Ensure the cable length does not exceed 20m.
  • B. Connect the power cord to the controller.
  • C. Connect the Redundant Earth ground as it is required for proper operation.

Step 2: Power on the Controller

Consult the manual for detailed instructions on how to properly ground the controller if necessary.

Step 3: Import Default PSets

  1. On the Controller’s Main Display Menu, press [specific button].
  2. This action will import three default PSets that are now editable.
  3. Additional PSets can be added by using the Add and Edit buttons.

Note: When connecting through the web browser interface, follow the same process. Refer to the Gen IV controller manual for connection instructions available at www.aimco-global.com/manuals.

AIMCO Technical Support Call Guide

Service/Repair

Service Training| Bill Kearney| Ken Maio
 | Direct: 503-262-3447| Direct: 503-262-3406
 | 503-254-6600, ext. 147| 503-254-6600, ext. 206
 | 800-852-1368, ext. 14| 800-852-1368, ext. 206
Service/Repair AcraDyne Tools| Gregg Walters| Bill Kearney
 | 503-262-3420| Direct: 503-262-3447
 | 503-254-6600, ext. 354| 503-254-6600, ext. 147
 | 800-852-1368, ext. 354| 800-852-1368, ext. 147
Service/Repair Electronics| Greg Charland| Donna Richmond
 | Direct: 503-262-3497| 503-254-6600, ext. 208
 | 503-254-6600, ext. 207

800-852-1368, ext. 207

| 800-852-1368, ext. 208
Service/Repair Pneumatic Tools| Gregg Walters| Bill Kearney
 | 503-262-3420| Direct: 503-262-3447
 | 503-254-6600, ext. 354| 503-254-6600, ext. 147
 | 800-852-1368, ext. 354| 800-852-1368, ext. 147
Technical Assistance
AcraDyne Tool Performance| Ken Maio|
and Specifications| Direct: 503-262-3406

503-254-6600, ext. 206

| applications@aimco-global.com
 | 800-852-1368, ext. 206|
Electronics Performance| Greg Charland| Ken Maio
and Specifications| Direct: 503-262-3497| Direct: 503-262-3406
 | 503-254-6600, ext. 207| 503-254-6600, ext. 206
 | 800-852-1368, ext. 207| 800-852-1368, ext. 206
Pneumatic Tool Performance| Bill Kearney| Ken Maio
and Specifications| Direct: 503-262-3447| Direct: 503-262-3406
 | 503-254-6600, ext. 147| 503-254-6600, ext. 206
 | 800-852-1368, ext. 14| 800-852-1368, ext. 206

FAQ

Q: What should I do if the controller does not power on?

A: Check the power cord connection and ensure it is securely plugged in. Also, verify that the power source is active.

Q: How do I add new PSets to the controller?

A: To add new PSets, navigate to the Main Display Menu and use the Add and Edit buttons to create and customize additional PSets.

“`

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals