Saxby trade CCT Microwave Emergency Instruction Manual
- August 5, 2024
- Saxby trade
Table of Contents
CCT Microwave Emergency
“`html
Technical Specifications:
-
Operating voltage: 220 ~ 240V AC 50/60Hz
-
Rated load: 400W (Capacitive load), 800W (Resistive load)
-
Stand-by power: 0.5W
-
Sensitivity: Ceiling mounted height – 3m, Ceiling mounted
height – 6m*, Wall mounted height – 2m -
Hold-time: 100% / 75% / 50% / 25% / 10%
-
Daylight sensor: 2Lux / 10Lux / 25Lux / 50Lux / Disable
-
Microwave frequency: Transmitting power – 1mW Max.
-
Detection range: Ceiling mounted height – 3m, Wall mounted
height – 1.5-2m -
Detection angle: 3-6m (radius), 12-15m, 360° (Ceiling), 120°
(Wall) -
Working temperature: -20°C ~ 60°C
Product Usage Instructions:
Settings Adjustment:
-
Sensitivity: Adjust sensitivity by selecting
the appropriate combination on the DIP switches based on your
application needs. -
Hold-time: Set the duration for which the
light remains at full brightness after movement detection. -
Daylight Sensor: Choose the desired daylight
threshold on the DIP switches. Light will activate upon movement if
daylight sensor is disabled.
Troubleshooting:
Issue | Cause | Remedy |
---|---|---|
The light will not come on | Incorrect light-control setting selected, Faulty |
lamp, No power
supply| Adjust settings, Replace lamp, Check power supply
The lamp is always on| Continuous movement in detection zone| Check detection
area setting
The lamp is on without any identifiable movement| The sensor is not mounted
for reliably detecting movement| Securely mount enclosure
The lamp will not work despite movement| Movement occurred but not identified
by the sensor| Reduce sensitivity, Check detection area setting
Care and Safety:
We recommend cleaning with a soft dry cloth. Avoid solvents or
abrasive cleaners that may damage the finish. Always switch off the
power supply before cleaning for safety.
FAQ:
Q: Where can I find further information about the product?
A: For additional details, please visit https://www.lighting- info.co.uk/95542
Q: What should I do if the light fitting malfunctions?
A: Refer to the troubleshooting section in the manual to
identify the cause and follow the recommended remedies
provided.
Q: How should I adjust the sensitivity of the sensor?
A: You can adjust the sensor sensitivity by selecting the
appropriate combination on the DIP switches based on your specific
requirements.
“`
Microwave Movement Sensor
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Technical Specifications:
Operating voltage
220 ~ 240V AC 50/60Hz
Rated load Stand-by power
400W (Capacitive load) 800W (Resistive load) 0.5W
Sensitivity Hold-time
Ceiling mounted height: 3m
Ceiling mounted
height: 6m*
Wall mounted height: 2m
100% / 75% / 50% / 25% / 10% 100% / 75% / 50% 100% / 75% / 50% / 25% / 10% 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor
2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency
5.8 GHz ±75MHz
Transmitting power
1mW Max.
Ceiling mounted
Detection range height: 3m
Wall mounted height: 1.5-2m
Detection angle
3- 6m (radius ) 12-15m 3600 (Ceiling) / 1200 (Wall)
Working temperature
-200C ~ 600C
*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% sensitivity is not able to detect motion signal.
Settings:
1. Sensitivity
Sensitivity can be adjusted by selecting the combination on the DIP switches
for different applications.
2. Hold-time
Hold-time refers to the time period that the light remains 100% on if no more
movement is detected.
3. Daylight sensor
Different daylight threshold can be preset on DIP switches. Light will always
turn on upon movement if daylight sensor is disabled.
I 100% II 75% III 50% IV 25% V 10%
123
100% 75% 50% 25% 10%
I 5s II 30s III 90s IV 3min V 20min VI 30min
456
5s 30s 90s 3min 20min 30min
I 2Lux II 10Lux III 25Lux IV 50Lux V Disable
789
2Lux 10Lux 25Lux 50Lux
Disable*
*Disable means the daylight sensor does not work. The sensor will turn on light once motion is detected regardless of ambient light level.
Trouble shooting: Malfunction Cause Remedy
The light will not come on
The lamp is always on
The lamp is on without any identifiable movement
The lamp will not work despite movement
Cause
Incorrect light-control setting selected Faulty lamp No power supply
Continuous movement in the detection zone The sensor is not mounted for
reliably detecting movement
Movement occurred, but not identified by the sensor (Movement behind wall,
movement of small object in immediate lamp vicinity etc.)
Rapid movements are being suppressed to minimize malfunctioning or the
detection radius is too small.
Remedy
Adjust daylight threshold setting Replace lamp Check power to sensor Check
detection area setting Securely mount enclosure
1. Reduce sensitivity. 2. Check the movement behind walls to avoid
facilities such as water pipe, fan, which may mis-trigger the sensor.
Check detection area setting
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish. For your safety, always switch off
the power supply before cleaning.
For further information, please visit https://www.lighting-info.co.uk/95542
V8 30/01/2024 UK Manufacturer: BH17 7BY EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
Instruction manual
HeroPro CCT Microwave Emergency
95542, 103940
www.saxbylighting.com
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Technical data
This light fitting is double insulated and does not require connection to an
earth circuit.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
Supply Voltage:
Bulb Type:
220-240 V~, 50 Hz
95542—-18/14/9W LED (SMD) CCT, 3000/4000/6000K 900/1400/1800Lm – 143.8Lm in EM
mode
103940—28/24/20W LED (SMD) CCT, 3000/4000/6000K 2000/2400/2800Lm – 190Lm in EM
mode
These products contain a light source of energy efficiency class D.
Non-replaceable light source
Replaceable control gear by a professional
Conformity with all relevant UKCA Directive requirements.
This light fitting should be connected to a fused circuit. If replacing an
existing fitting, make a careful note of the connections. Waste electrical
products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your local authority or retailer for recycling
advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between each light fitting. Avoid locating any cables in
positions that would cause a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk from being cut, trapped or
damaged. The mains supply cable must have a minimum cross section area of
1.0mm2. Cables must be protected using suitable conduit or plastic trunking.
The products can be wall or ceiling mounted. If wall mounting ensure that the
power supply is at the bottom.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an
Earth circuit. Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check with your Local
Authority or local store for recycling advice.
This product is not suitable for dimming.
IP65
This product is rated at IP65
IK10 This product is rated at IK10 for 95542.
IK08 This product is rated at IK08 for 103940.
Battery parameters:
Duration
3 hours (180 Minutes)
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires. Note the switch is turned off before installation. The
ceiling surface must be flat and smooth to ensure a good fit. Ensure that the
screws and cable entry points are sealed to maintain the IP rating of the
product. · Twist and remove the lamp cover from the product, keep safe for
refitting later.
· Turn the clip to loose the LED tray in the rear casing.
· Using the rear casing as a template mark the position to drill out the
fixing holes. Take care to avoid damaging any concealed wiring and pipes.
· Fix the rear casing into the position using the installation plugs and
screws. · Pull the cable through the cable entry hole and seal to maintain the
IP rating
and wire as detailed Wiring Diagram.
Maximum Operating Humdity Change over time Battery Specification Battery Charge Time Battery warranty Ambient Temperature
90% Approximately 1s LifePO4 3.2V 1500mAh 24 Hours 5 years 0ºC – 45ºC
· Unscrewed the battery box cover and then connect the battery DC connector
together before commissioning.
· Refit the LED tray back into the rear casing and lock the clip. · Twist the
lamp cover back onto the product and lock in place. · Replace fuse or circuit
breaker and switch on. Your light is now ready for use.
The wattage is changeable between the diffrent wattage using the wattage switch on the driver before installation.
18W 14W 9W For the 95542 is the 18W/14W/9W selectable
28W 24W 20W For the 103940 is the 28W/24W/20W selectable
The colour is changeable between 3000/4000/6000K using the CCT switch on the
driver before installation.
6000K 4000K 3000K
Choose your preferred wattage and colour before installing by wattage switch or CCT switch on the driver. Note: Befeore you change the wattage or colour, please turn off the power switch for safety.
1
2
3
4
5
6
- Product images may vary.
Bezels for 95542 only
The following individual casings are available for purchase separately.
95545 : Chrome plain 95548 : Black plain 95551 : Anthracite grey plain
95546 : White eyelid 95549 : Black eyelid 95552 : Anthracite grey eyelid
95547 : White grill 95550 : Black grill 95553 : Anthracite grey grill
Wiring
· This product is double insulated and must not be earthed. If there are any
incoming earth cables, they must be joined together and well insulated with
good quality insulation tape. This is to ensure earth continuity throughout
your property.
SUPPLY
PUSH DOWN LIGHT FITTING
INSERT CABLE
· Having correctly identified the wiring from your existing light fitting, connect to the quick fit connection block in the following way, using the supplied link cables where necessary.
Non-Maintained Wiring:
The product is normally off and comes on during a power failure
MW SENSOR
LED Driver
INPUT OUTPUT
SUPPLY
LIGHT FITTING L N N L’
LN
N
NEUTRAL
L/PL
N
Emergency
SL PL Lout
Maintained (Unswitched) Wiring:
The product is on permanently and comes on
during a power failure SUPPLY
MW SENSOR
INPUT OUTPUT
LIGHT FITTING L N N L’
LED Driver
LN
N
NEUTRAL
SWITCH LIVE LINK CABLE
L/PL N
Emergency
PERMANENT LIVE
“Lout” terminal is only for connecting with OUTPUT of MW sensor, don’t for the
INPUT
Maintained (Switched) Wiring: The product is used as a normal light – switch
on/off, light turns on/off. Comes on during a power failure.
SUPPLY
MW SENSOR
INPUT OUTPUT
LIGHT FITTING L N N L’
LED Driver
LN
N
NEUTRAL
L/PL
N
Emergency
SL PL Lout
SL PL Lout
“Lout” terminal is only for connecting with OUTPUT of MW sensor, don’t for the INPUT
SWITCH LIVE PERMANENT LIVE
“Lout” terminal is only for connecting with OUTPUT of MW sensor, don’t for the INPUT
Sensor Used as Master Function
L
N
……
Lout
Master
Slave
Master
N
SL PL Lout
N
SL PL
N
SL PL
N
SL PL Lout
……
Emergency
LED Driver LN
LED Driver LN
LED Driver LN
Emergency
LED Driver LN
L/PL N
L/PL N
INPUT LN
OUTNPUT 0.75 1.5
NL
INPUT LN
OUTNPUT 0.75 1.5
NL
10%
30min
89
2Lux
10Lux
25Lux
50Lux
123456789
LED 95542 LED 103940
LED 95539 LED 102732
10%
30min
89 2Lux
10Lux 25Lux 50Lux
123456789
LED 95542 LED 103940
The master light LED 95542 match with the slave light LED 95539, in total link QTY is Max. 10 lamps included the master light. The master light LED 103940 match with the slave light LED 102732, in total link QTY is Max. 7 lamps included the master light.
Check that…
You have correctly identified the wires. The connections are tight. No loose
strands have been left out of the connection block.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>