DNAKE 300884 Gas Sensor Owner’s Manual

August 3, 2024
DNAKE

DNAKE 300884 Gas Sensor

Product Usage Instructions

Installation

  • To install the gas sensor, choose a suitable location on the wall or ceiling. Ensure it is easily accessible for maintenance.

Power Connection

  • Plug in the gas sensor to an AC power source. Make sure the power source is stable and reliable.

Calibration

  • Follow the manual instructions to calibrate the gas sensor for accurate detection. This ensures the sensor maintains strong consistency in detecting gas levels.

Replacement

  • If needed, replace the plug of the gas sensor with one suitable for your country’s power outlet standards.

FAQ

  • Q: Can the gas sensor be used outdoors?
    • A: No, the gas sensor is designed for indoor use only.
  • Q: What should I do if the alarm sounds?
    • A: Evacuate the premises immediately and contact emergency services.

Instruction

The Smart Gas Sensor utilizes advanced ZigBee wireless networking technology, ensuring minimal power consumption. Its primary function is to detect and prevent natural gas leakage, safeguarding against potential harm. Equipped with a high stability semiconductor gas sensor, this device offers reliable performance, minimal sensitivity drift, and various other advantageous features. When the gas density in the air surpasses the alarm level, the sensor promptly triggers an alarm. This sensor is suitable for use in kitchens or areas susceptible to gas leakage.

Key Features

  • Standard ZigBee 3.0 protocol, good compatibility
  • Super low power consumption design
  • Anti interference from smoke and oil stain
  • Elaborate auto-calibration, make a strong consistency
  • Adopts flame retardant engineering housing material
  • Free tool installment, AC powered, plug in and use
  • Replaceable plug, suitable for users from different countries
  • Smart and fashion design.

Technical Parameters

  • Model Name: JT-GA100-ZB
  • Wireless Technology: ZigBee
  • Transmission Frequency: 2.4 GHz
  • Working Voltage: AC 220V
  • Standby Current: ≤ 200 mA
  • Operation Environment: 0℃to +55℃≤ 95% RH
  • Detected Gas: Methane (Natural gas)
  • Alarm LEL: 8% LEL Methane (Natural gas)
  • Concentration Error: ±3% LEL
  • Alarm Method: Audible and visual alarm, and wireless connection alarm
  • Alarm Sound Pressure: ≥70 dB (1 m in front of the gas detector)
  • Installation Method: Wall-mounting or ceiling-mounting
  • Dimension: φ 85 x 30 mm

More Information

Stock Code

  • 300884

Email: sales01@dnake.com

Scan

Documents / Resources

| DNAKE 300884 Gas Sensor [pdf] Owner's Manual
300884 Gas Sensor, 300884, Gas Sensor, Sensor
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals