ZOOZ ZEN05 800LR Outdoor Plug User Manual
- August 3, 2024
- ZOOZ
Table of Contents
ZOOZ ZEN05 800LR Outdoor Plug
Product Information
Specifications
- Model Number: ZEN05 800LR
- Power: 110 VAC, 60 Hz
- Maximum Load: 15 A, 150 W LED bulbs, 1000 W incandescent, 1/3 hp motor
- Range: Up to 150 (up to 1300 with LR) line of sight
- Installation and Use: Indoor or outdoor
- IP Rating: 65
- Dimensions: 2.25 x 3.25 x 1.5 Cord Length: 6.5
Product Usage Instructions
-
Adding Device to Your Hub
To add the Outdoor Plug to your hub, follow these steps: -
Initiate inclusion (pairing) in your hub’s app or web interface.
-
If using an S2 hub, enter the DSK PIN or scan the QR code on the plug’s outlet for SmartStart inclusion.
-
Ensure the hub is looking for new devices.
-
Plug the ZEN05 into a receptacle. The indicator will flash blue during pairing and turn green once completed.
-
Installation Caution
Before plugging anything in, ensure that the total load does not exceed 15 A. Do not connect heavy-duty equipment exceeding this limit. -
Factory Reset and Troubleshooting
If experiencing issues, try initiating exclusion in your hub to remove the device. For factory reset, follow manufacturer instructions. -
Association and Safety Warning
The Outdoor Plug supports Group 1 for Lifeline communication and Group 2 for basic on/off control. Ensure proper indoor installation and storage.
FAQ
Q: What should I do if the Outdoor Plug won't add to my hub?
A: Try initiating exclusion in your hub and following the steps to remove the device before attempting re-inclusion.
Q: How do I perform a factory reset on the Outdoor Plug?
A: When your network's primary controller is missing or inoperable, refer to the manufacturer's instructions for factory resetting the device.
Q: What safety precautions should I consider when installing the Outdoor Plug?
A: Ensure proper indoor installation, avoid direct exposure to heat sources or flames, and keep the device away from chemicals, water, and dust to prevent damage or fire hazards.
Scan to register your product for an extended warranty and more perks.
FEATURES
- Z-Wave® on/off control of lights and small appliances
- IP65 rated for outdoor use
- NEW 800 series Z-Wave® chip for faster control
- Z-Wave® Long Range for ultra-reliable no-mesh communication
- S2 authenticated security and SmartStart
- Supports OTA firmware updates
- ETL is listed for compliance with North American safety standards
SPECIFICATIONS
- Model Number: ZEN05 800LR
- Z-Wave® Region: US/CA/MX
- Power: 110 VAC, 60 Hz
- Maximum Load: 15 A, 150 W LED bulbs, 1000 W incandescent, 1/3 hp motor
- Range: Up to 150 ft (up to 1300 ft with LR) line of sight
- Installation and Use: Indoor or outdoor
- IP Rating: 65
- Dimensions: 2.25” x 3.25” x 1.5” Cord Length: 6.5”
CAUTION
This is an electrical device – please use caution when installing and
operating the Outdoor Plug. Remote control of appliances may result in
unintentional or automated activation of power. Do NOT use this Z-Wave® device
to control electric heaters or other appliances that produce the risk of fire,
burns, or electrical shock when unattended.
INSTALLATION
Plug the Outdoor Plug into any standard grounded 110 V receptacle. Do NOT connect any devices to the plug at this point. Click the Z-Wave® button to see if the LED indicator comes on and off. If the LED indicator doesn’t light up at all, please try a different receptacle. If it’s still off, please get in touch with our support team: ask@getzooz.com.
BEFORE YOU PLUG ANYTHING IN
-
Make sure the load you are about to connect does NOT exceed 15 A in power. This Outdoor Plug can hold up to 15 A in total.
-
Connecting heavy-duty equipment to this Outdoor Plug will DAMAGE the device and may cause the connected appliance to malfunction. Do NOT plug washers, dryers, refrigerators, or motors over 1/3 hp into this Outdoor Plug.
-
This product can be included and operated in any Z-Wave® network with other Z-Wave® certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This product features the latest Security 2 (S2) framework to remove smart home network hacking risks. This device is equipped with a unique authentification code for trusted wireless communication.
-
This is an ETL certified device. ETL, just like UL, is a Nationally Recognized Testing Laboratory. The ETL mark is proof of product compliance with North American safety standards.
WARNING
- This product should be installed indoors upon completion of any building renovations.
- Before installation, the device should be stored in a dry, dust-and-mold-proof place.
- Do not install the device in a place with direct sun exposure, high temperature, or humidity.
- Keep away from chemicals, water, and dust.
- Ensure the device is never close to any heat source or open flame to prevent fire.
- Ensure the device is connected to an electric power source that does not exceed the maximum load power.
- No part of the device may be replaced or repaired by the user.
Z-WAVE CONTROL
- ADD DEVICE to your hub
- Initiate inclusion (pairing) in the app (or web interface). Not sure how? Scan the QR code below for instructions dedicated to your hub or visit www.support.getzooz.com for more details.
- If you’re using an S2 hub, it will ask you to enter the DSK PIN or scan the QR code printed on the side of the plug’s outlet to complete SmartStart inclusion.
- PLUG the ZEN05 into a receptacle
While the hub is looking for new devices, click the Z-Wave® button 3 times as quickly as possible. The LED indicator will start flashing blue to confirm inclusion mode and turn green for 1 second once inclusion is completed.
QR/PIN CODE
Scan the code printed on the device for SmartStart pairing and NOT the QR
codes below which link to hub specific instructions.
- SmartStart-enabled products can be added to a Z-Wave® network by scanning the Z-Wave® QR Code present on the product with a controller providing SmartStart inclusion.
- Choose your hub and scan the QR code with your phone’s camera. Then click on the link to access the step-by-step pairing instructions.
NEED SOME HELP?
www.support.getzooz.com.
TROUBLESHOOTING
The Outdoor Plug won’t add to your hub. Try this:
- Initiate EXCLUSION in your hub and click the Z-Wave® button 3 times as quickly as possible. Then try adding it again after it is successfully excluded (this works as a reset and can be tried even if the plug was never connected to your hub in the past).
- Click the Z-Wave® button 4-5 times quickly when adding it or try adding it in a non-secure mode.
- Bring the Outdoor Plug closer to your hub, it may be out of range.
- Double-check if the device is powered.
- Get more troubleshooting tips for your hub at www.support.getzooz.com.
EXCLUSION (REMOVING/UNPAIRING DEVICE)
- Bring the Outdoor Plug within direct range of your Z-Wave® gateway (hub).
- Put the Z-Wave® hub into exclusion mode (not sure how to do that? ask@getzooz.com).
- Press and release the Z-Wave® button 3 times quickly.
- Your hub will confirm exclusion and the Outdoor Plug will disappear from your controller’s device list.
FACTORY RESET
When your network’s primary controller is missing or otherwise inoperable, you
may need to reset the device to factory settings manually. To complete the
process, make sure the plug is powered, then click the Z-Wave® button twice
and hold it the third time for 10 seconds. The LED indicator will flash green 3
times to confirm a successful reset.
NOTE:
All previously recorded activity and custom settings will be erased from the
device’s memory.
ASSOCIATION
- The Outdoor Plug supports Group 1 for Lifeline communication and Group 2 with up to 5 devices for basic on/off control. This device will send a Basic Set command to Group 2 whenever it changes its on/off status.
- Please note that not all Z-Wave® systems give users access to direct association settings so if you’re not sure where to find it, please get in touch with our support and we’ll be happy to help.
WARRANTY
This product is covered under a 12-month limited warranty and extended 5-year warranty once registered. To read the full warranty policy, register your product, or file a claim, please visit www.getzooz.com/warranty.
ADVANCED SETTINGS
Please refer to your controller’s user guide for advanced programming instructions as they are different for every software. Not sure where to start? Go to www.support.getzooz.com for detailed instructions on how to change the settings on SmartThings, Hubitat, and more. Or just email us: at ask@getzooz.com.
-
Parameter 1: Decide how the LED indicator behaves depending on the on/off status of the plug. The LED indicator will flash twice to confirm that a setting has been changed.
- Values: 0 – LED indicator is on when the plug is on, LED indicator is off when the plug is off (default); 1 – LED indicator is on when the plug is off, LED indicator is off when the plug is on; 2 – LED indicator is always off; 3 – LED indicator is always on.
Size: 1 byte dec
NOTE: Click the Z-Wave® button 6 times quickly to toggle between the values of this parameter manually from the device.
- Values: 0 – LED indicator is on when the plug is on, LED indicator is off when the plug is off (default); 1 – LED indicator is on when the plug is off, LED indicator is off when the plug is on; 2 – LED indicator is always off; 3 – LED indicator is always on.
-
Parameter 2: Use this parameter to set the auto turn-off timer: the time after which you want the Outdoor Plug to automatically turn off once it has been turned on. The number entered as a value corresponds to the number of minutes.
- Values: 0 – timer disabled (default); 1-65535 (minutes).
- Size: 4 byte dec
-
Parameter 4: Use this parameter to set the auto turn-on timer: the time after which you want the Outdoor Plug to automatically turn on once it has been turned off. The number entered as a value corresponds to the number of minutes.
- Values: 0 – timer disabled (default); 1-65535 (minutes).
- Size: 4 byte dec
-
Parameter 6: Choose the recovery state for your Outdoor Plug if a power outage occurs.
- Values: 0 – Outdoor Plug automatically turns OFF once power is restored (it ignores the status before power outage); 1 – Outdoor Plug automatically turns ON once power is restored (it ignores the status before the power outage); 2 – Outdoor Plug remembers the status before power outage and turns back to it (default).
- Size: 1 byte dec
NOTE: Click the Z-Wave® button 10 times quickly to toggle between the values of this parameter manually from the device.
-
Parameter 7: Set the brightness level of the LED indicator.
Values: 0 – bright; 1 – medium; 2 – low (default).
Size: 1 byte dec
NOTE: Click the Z-Wave® button 8 times quickly to toggle between the values of this parameter manually from the device. -
Parameter 8: Choose if you want to use the physical Z-Wave® button on the plug to turn the outlet on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the outlet on or off remotely using your Z-Wave® hub.
- Values: 0 – manual control disabled; 1 – manual control enabled (default).
- Size: 1 byte dec
-
Parameter 9: Choose how you want your Smart Plug to report power consumption to your hub. The number entered as value corresponds to the number of Watts the appliance needs to go over for the change to be reported. So if 5 Watts are entered by default, the Smart Plug will report any change in power usage over 5 Watts (whether it’s at least 5 Watts more or 5 Watts less compared to the previous report).
- Values: 5 – 50. Default: 5.
- Size: 1 byte dec
-
Parameter 10: Choose how often you want your Smart Plug to report power consumption to your hub. The number entered as a value corresponds to the number of minutes. So if 5 is entered by default, the Smart Plug will report power consumption (Wattage) every 5 minutes.
- Values: 1 – 65535. Default: 5.
- Size: 4 byte dec
SCAN FOR ALL SETTINGS
Choose your hub and scan the QR code with your phone’s camera. Then click on the link to access the step-by-step instructions on how to access advanced settings for the plug on your Z-Wave® system.
Here is the list of command classes supported by this device:
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2
- COMMAND_CLASS_SWITCH_BINARY_V2
- COMMAND_CLASS_CONFIGURATION_V4
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
- COMMAND_CLASS_METER_V5
- COMMAND_CLASS_TRANSPORT_SERVICE_V2
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY
- COMMAND_CLASS_INDICATOR_V3
- COMMAND_CLASS_POWERLEVEL
- COMMAND_CLASS_SECURITY_2
- COMMAND_CLASS_SUPERVISION
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES AND AFFILIATES BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHE-THER IN AN ACTION IN CONTRACT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DA-MAGES. ZOOZ’S LIABILITY AND CUSTOMER’S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CON-NECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT ZOOZ’S OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS TO WHICH DA-MAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM ZOOZ’S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC STATEMENT
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used according to instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in any given installation. If this equipment causes harmful interference to radio or television reception, the user may try to correct the interference by taking one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between equipment and receiver
- Connect the equipment to a separate outlet or circuit from the receiver
- Consult the dealer or an experienced radio/TV technician for additional assistance
All brand names displayed are trademarks of their respective holders. © Zooz 2024 www.getzooz.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>