QAZQA Denmark WL Black Smoke Hexagon PIR Instruction Manual

August 5, 2024
QAZQA

QAZQA Denmark WL Black Smoke Hexagon PIR Instruction Manual

Safety Precautions

SAFETY INSTRUCTION

Flg. 1(A) Detection RangeType| Detection  range| Detection angle| Suitable height
---|---|---|---
PIR| Max+_7m| 110º| 2.5m

LUX Adjustment

TIME Adjustment

Overall Sizes:

Please study the instruction manual and below information carefully before installing or using this product. Please keep this user manual for further reference

  1. The luminaires may only be installed by authorized and qualified technicians according the valid regulations for electrical installation.
  2. Maintenance of the luminaries is limited to their surfaces. During maintenance no moisture can come into contact with any areas of the fer minal connections or voltage control parts.
  3. The electrical supply must be switched off af the outset, preferably by means of a switch in the distribution box, before any installation, maintenance or repair work is undertaken.
  4. Exterior lighting must not be installed during rain.
  5. Take account of the minimal separation distance from of her objects and the room required around the fitting.
  6. Ifin any doubt, consult a professional, taking local installation requirements info account. Some countries stipulate that lighting may be installed only by registered installers.
  7. Clamping screws in electrical connections must be adequately fightened. This is parficularly the case with 12V low voltage conductors.
  8. Clean with a clean, dry cloth or brush, use no solvents or abrasives. Avoid dampness on all electrical components
  9. Take account of all available technical information.
  10. Meaning of symbols:
    This icon indicates the level of water-proof and dust-proof
    Protection Class I: the fitting must be earthed
    Protection Class II: the fitting is doubled insulated and does not require earthing
    Protection Class Ill: the fitting is low voltage
    Minimum distance from lighted objects (meters)
    The type of lamp and maximum size and wattage indicated in each lighting unit must not be exceed; different items require different kind of light sources with different bulb icons
    The armature is designed to work only with the indicated voltage. Different items require different working voltage.
    The luminaire can be used in combination with a dimmer
    The luminaire can be dimmed by wall switch
    The reference light angle and light space of the luminaire

This luminaire cannot be disposed together with normal domestic waste in standard rubbish can, but you have to bring it to a staging area for electrical waste

  1. Take note of the symbols when connecting wires:

|

L

| Live conductor

---|---|---
| Earth conductor

N

| Neutral conductor


FittinQ B.V.

Smaragdweg 52, 5527 LB Hapert,
The Netherlands
www.qazqa.nl
FittinQ LTD
55 Baker Street,
London, W10 7EU
United Kingdom

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals