Qualitron PWMREP4 4 Channels Amplifier / Repeater Installation Guide
- August 3, 2024
- Qualitron
Table of Contents
Qualitron PWMREP4 4 Channels Amplifier / Repeater
Product Information
Specifications:
- Model: PWMREP4
- Type: Amplifier / Repeater
- Channels: 4 channels (RGB/RGBW/CT/DIM)
- Power Supply Voltage: 12-24VDC
- Power Factor: 0.98
- Maximum Current: 20A
- Efficiency: >96%
Product Usage Instructions
- Power Connection: Connect the product to a power supply with a voltage range of 12-24VDC.
- Channel Setup: Configure the 4 channels for RGB, RGBW, CT, or DIM functionalities based on your requirements.
- Signal Amplification: Use the amplifier/repeater to boost and extend the signal for connected RGB/RGBW/CT/DIM devices.
- Efficiency Management: Monitor the product’s efficiency (>96%) to ensure optimal performance.
Frequently Asked Questions (FAQ):
-
Q: What is the recommended power supply for the PWMREP4?
A: The recommended power supply voltage for the PWMREP4 is within the range of 12-24VDC. -
Q: How many channels can be controlled with the PWMREP4?
A: The PWMREP4 can control up to 4 channels, supporting RGB, RGBW, CT, or DIM functionalities.
Technical Data
- Rated supply voltage 12..24VDC
- Power factor 0,98
- Max. main current 20A
- Efficiency >96%
- Standby power <0,5W
- Output Vin-0,1V
- Input 4X PWM single channel
- Input 1X PWM both channels
- Input current 10mA single channel
- Signal cable lenght 10 m with 0.5 – 2.5mmq
- Power Cable lenght 2m 4mmq Keep Short as possible
- Operating frequencies up to 1KHz PWM common anode
- Regulation Linear or exponential
- Max output current 4 ch 4 x 5A
- Max output current 3ch 3 x 6A
- Min Output load 480W@24V 240W@12V
- Min Output load 10W
- Protections Supplied by power supply
- Insulation Class II SELV
- Signal Connections Screw connectors 0.5-1.5mmq
- Output connections 4mmq rail connectors
- Operating temperature 10°C … +45°C
- TC point 70°
- Storage temperature 15°C … +60°C
- Dimensions LxPxA 138x40x29 mm
- Weight 340g
- Protection degree IP 40
Safety note
Installation of this device may only be carried out by specialist staff .
Switch off the mains supply before device connection Keep this document in a
safe place
Respect the safety and accident prevention regulations Dispose of according to
instructions
Standard and Directives
2014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU + 2015/863/EU (RoHs);
2009/125/ECODESIGN regulation (EU) n°2019/2020 and 341/2021 amendment EN
61347-2-11:2001 + A1:2017; EN 61347-1:2015 EN 55015:2019 + A11:2020; EN
61000-3-3:2013; EN 61457:2009; EN IEC 61000-3-2:2019 + A1:2021
EN 63000:2018 EN IEC 62442-3:2022
Areas of application
The device may only:
- be used for the specified applications.
- be used for safe installation in dry and clean environment.
- be installed in such a way that access is only possible using a tool
- Respect label data
Dimensions (mm)
Connections
1.5–4 mm2 A WG 15..11
fine-stranded a fili sottili
Inner Package
This document
The Device
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>