ecler eCA120 Stereo Micro-Amplifier User Manual
- June 3, 2024
- ecler
Table of Contents
- IMPORTANT REMARK
- IMPORTANT SAFETY INSTRUCTIONS
- IMPORTANT NOTE
- COMPLIANCE WITH INTERNATIONAL STANDARDS
- INTRODUCTION
- INSTALLATION
- OPERATION AND USAGE
- CLEANING
- DIAGRAM and LIST OF FUNCTIONS
- BLOCK DIAGRAM
- CONFIGURATION DIAGRAM
- TECHNICAL CHARACTERISTICS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
eCA120 Stereo Micro-Amplifier
ser Manual USER
MANUAL
IMPORTANT REMARK
WARNING: SHOCK HAZARD – DO NOT OPEN
The lightning flash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to
alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of “ ” may be
of sufficient magnitude to constitute a risk of electric shock. The external
wiring connected to the terminals requires installation by an instructed
person or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to
rain or moisture.
WARNING: An apparatus with Class I construction shall be connected to a
mains socket-outlet with a protective earthing connection.
IMPORTANT SAFETY INSTRUCTIONS
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug the apparatus during lightening sorts or when unused for long periods of time.
- Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
- Equipment is connected to a socket-outlet with earthing connection by means of a power cord.
- The marking information is located at the bottom of the unit.
- The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on apparatus.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING: This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment centre.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be
caused to people, animal or objects due to failure to comply with the warnings
above.
IMPORTANT NOTE
Thank you for choosing our Ecler eCA120 Stereo Micro-Amplifier!
It is VERY IMPORTANT to carefully read this manual and to fully understand its
contents before any connection in order to maximize your use and get the best
performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its
maintenance be carried out by our authorised Technical Services.
Ecler eCA120 comes with a 3-year warranty.
COMPLIANCE WITH INTERNATIONAL STANDARDS
The eCA120 micro amplifier complies with the following international
standards:
EN55103-1 Electromagnetic Compatibility.
Product family standard for audio, video, audio-visual and entertainment
lighting control apparatus for professional use Part 1: Emission
EN55103-2 Electromagnetic Compatibility.
Product family standard for audio, video, audio-visual and entertainment
lighting control apparatus for professional use Part 2: Immunity
EN60065
Audio, video and similar electronic apparatus. Safety requirements Complying
with the requirements of directives 2006/95/EC and 2004/108/EC
INTRODUCTION
The eCA120 is a stereo amplifier with a very small size and a remote control function through a 0-10VDC port; it’s an ideal choice for audio-visual applications: school rooms, meeting rooms, multimedia presentations, commercial premises, etc.
5.1. Main characteristics
- 2 x 60 W RMS @ 4 amplifier
- Universal external power supply
- AUTO STANDBY function: in the absence of an audio signal the unit automatically goes into STANDBY mode, minimising power consumption
- Lightweight, silent, high-performance amplifier (fan-free convection cooling)
- Suitable for stereo and parallel (mono)
- 1 unbalanced stereo line input (LINE IN / STACK), with dual RCA connector and 3pin Euroblock connector
- Local volume control by knob
- Remote volume control by WPm series wall panel (0-10VDC)
INSTALLATION
WARNING: Non-compliance with the instructions or neglecting warnings may cause malfunction or even damage the unit:
- Avoid turning on the device without the speakers connected to its outputs and without having previously set the volume/gain controls to minimum level.
- Always use shielded cables to make connections between devices.
- In an amplifier, avoid placing the speaker output cables close to other signal cables (micro, line…). This may cause the system to oscillate, damaging the amplifier and speakers.
6.1. Location and assembly
The eCA120 is suitable for installation on a wall or under a surface
(table, shelf, cupboard, etc.), thanks to its design and layout of its
connectors, controls and LED indicator lights.
6.2. Mains connection
The amplifier is powered by alternating current through its external power
source: 100240 VAC and 50-60 Hz.
This apparatus must be earthed through its mains cable (earth resistance, Rg =
30, or lower). The atmosphere should be as dry and dust free as possible. Do
not expose the unit to rain or water splashes. Do not place liquid containers
or incandescent objects like candles on top of the unit.
Should any work or connection / disconnection task be done, always disconnect
the unit from the mains supply. There are no elements that can be manipulated
by the user inside the amplifier.
To avoid buzzing, do not allow the power cable to intertwine with the shielded
cables that transport the audio signal.
6.3. Audio input connections
The eCA120 input channel only supports stereo line signals (or two mono
signals). It has an unbalanced stereo connection with dual RCA connector and
3-pin Euroblock connector (LINE IN / STACK). This input is designed to
support -6dBV to 0dBV signals, given that the rotary volume control of the
front panel has an extra +6dB of gain at its maximum position. This audio
input can receive signals from CD players, radio tuners, mixing consoles,
media players, audio outputs of computers and tablets, etc.
LINE IN and STACK connections are linked, so that when you use one of them as
an audio signal input for your unit, you can use the other to send that signal
to another unit or external equipment.
Note: Turntables CANNOT BE CONNECTED directly to this device because none
of the inputs have an RIAA preamp.
6.4. Audio output connections
The amplified output (OUT L and R) have Euroblock connectors.
The connection cable that connects the eCA120 connectors and the speakers
should be good quality, with a suitable cross section and as short as
possible.
The L and R outputs respectively deliver an amplified version of the L and R
inputs of the unit.
Remember that the minimum load impedance for each output channel is 4. For
correct operation of the eCA120, under no circumstances must you work with
impedance lower than specified above.
6.5. Remote control port
The RJ-45 REMOTE connector allows to connect a WPmVOL-type wall control
panel (or another model of the WPm series) to adjust the overall output
volume. The connection is made with a standard CAT5 cable between the WPm wall
panel and the REMOTE connector of the eCA120. Note: The jumper labeled
“REMOTE” on the front panel has to be in the ON position to enable the remote
volume control.
OPERATION AND USAGE
7.1. Start up
Start up the eCA120 by connecting the equipment to an external power source
to which the DC 24V connector of the eCA120 has already been connected. The
LED indicator ON/STBY immediately lights up on the front panel. We recommend
you turn on all the devices in the following order: sound sources, mixer,
equalisers, active filters and processors and, finally power amplifiers.
Powering off should be done by following the exact reverse sequence. Following
this order, the introduced noise due to turning on or switching off the
devices will not affect those further on in the chain and will be inaudible.
Once turned on, the front volume control (VOLUME) and the controller connected
to the REMOTE port (if any) may be used to set the output volume of the signal
amplified by the unit.
7.2. AUTO STANDBY Function
The AUTO STANDBY function (idle or low consumption mode) means you can
install the eCA120 in inaccessible places and leave the device connected to
the mains power
supply permanently because when no signal is detected, it automatically goes
into standby mode, saving energy.
To enable the AUTO STANDBY mode, the jumper labeled “AUTO STBY” on the front
panel has to be in the ON position. When it is enabled and after 2 minutes or
more without any audio signal at the audio input of the device (or a very
weak signal, lower than the activation threshold), the eCA120 will
automatically switch into standby mode, lighting up the amber ON/STBY LED
located on the front panel of the device. When a valid audio signal is
detected in any of the inputs, the eCA120 leaves standby mode and starts
operating normally again and the ON/STBY LED goes green.
When enabling the AUTO STANDBY mode with the front panel jumper (ON position),
one of the 2 following assumptions may occur:
a) There is NO audio signal in the inputs. Result: the amplifier immediately
goes into AUTO STANDBY mode
b) There is an audio signal in the inputs. Result: the amplifier stays active
7.3. LED indicators
-
SP: The signal presence or SP LED indicator shows that there is a signal in the amplifier input. This lights up when the input level reaches the established detection threshold.
-
CLIP: The saturation or CLlP LED indicator comes on when the signal delivered to the speakers is close to the amplifier’s clipping or saturation level. Input signals should be set to ensure the CLIP (saturation or cut off) indicators never stay on, but that they do so at most to the beat of the lowest sound frequencies. Otherwise the amplified signal will be distorted with low quality and low intelligibility.
Note: If the input signal is too high, the CLIP indicator lighting up very frequently over a short time interval (a few seconds), the amplifier may go into protection mode, being muted to return to normal operation in a short time -
ON/STBY: the green light comes on when the equipment is in normal operating mode and it goes orange when it is in standby or low consumption mode (STANDBY).
7.4. Setup jumpers
- REMOTE: REMOTE: enables (ON) the remote volume control from a WPm-type wall panel (or another model of the WPm series) connected to the REMOTE port.
- AUTO STANDBY: Switch the AUTO STANDBY function on (ON) or off. When the function is on, the eCA120 will automatically go into STANDBY or low consumption mode in the absence of audio signals in its inputs.
CLEANING
The eCA120 must not be cleaned with solvents or abrasive substances which may damage the prints. Clean using a cloth moistened in water and a neutral liquid detergent, then dry with a clean cloth. Under no circumstances allow water to enter any of the orifices in the equipment.
DIAGRAM and LIST OF FUNCTIONS
- ON/STBY on or standby indicator light
- DC24V power connector
- CLIP indicator light
- OUT L / R amplified output
- SP input signal presence indicator light
- VOLUME knob
- Euroblock input line, LINE
- RCA input line, LINE1
- RJ-45, REMOTE connector
- REMOTE & AUTO STANDBY jumpers
BLOCK DIAGRAM
CONFIGURATION DIAGRAM
JUMPERS FACTORY ADJUST
AUTO STANDBY | ON |
---|---|
REMOTE | OFF |
TECHNICAL CHARACTERISTICS
eCA120
Power (stereo/mono)Frequency response
THD+Noise @ 1kHz Full Pwr. SPKR
OUT
Channel crosstalk @ 1kHz
Inputs Sensitivity nom/ImpedanceVolume adjustSignal Noise Ratio
Remote control (externally selectable)
Auto standby
DC supplyMains (using supplied DC adapter)| 2x56W@4Ω 1% THD
2x68W@4Ω 10% THD
2x34W@8Ω 1% THD
2x41W@8Ω 10% THD
15Hz – 30kHz (-3dB)
< 0.15%
65dB
0dBV/>20kΩ (VOLUME at 0dB)
-∞ to +6dBV
85dB (VOLUME at 0dB)
Master Volume
Analog. 0 -10V based
Time: 2 minutes (aprox.)
Threshold: -40dBV (L&R)
24V
100-240VAC + External PSU 24VDC
Power consumption
pink noise, 1/8 power pink noise, 1/3 power Standby (time 2 minutes)| 38VA / 26W
61VA / 51W
<2.5W
General
Dimensions WxDxH Weight| 190x90x48mm (knobs and connectors excluded)
600g
All product characteristics are subject to variation due to production
tolerances.
NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements
in the design or manufacturing that may affect these product specifications.
For technical queries contact your supplier, distributor or complete the
contact form on our website, in Support / Technical requests.
Motors, 166‐168 08038 Barcelona
Spain ‐ (+34) 932238403
information@ecler.com
www.ecler.com