NYSTAND GPB-MB10 10000mAh Power Bank User Manual
- July 30, 2024
- NYSTAND
Table of Contents
GPB-MB10 10000mAh Power Bank
“`html
Product Specification
Document Number: BBD-WI-001
Product Name: POWER BANK-GPB 10000mAh
Product Model: GPB-MB10(Black);
GPB-MW10(White); GPB-MX10(X represents the color variable)
Edition: V1.0
Date: 2023.12.8
Specification: (38.5Wh) 3.85V/10000mAh
Specifications
Project | Parameter |
---|---|
Capacity | 10000mAh |
Weight | 245g |
Size | 1097120.30 mm |
Conversion Rate of Whole Machine | % – Not specified |
Product Usage Instructions
Working Modes:
-
Sleep Mode: Automatically entered when no keys are pressed, no
load, no charge. Saves power consumption for longer storage
time. -
Standby Mode: –
-
Operation Mode: –
Charging Information:
- Input Voltage Range: 4.5-14V
- Output Voltage Range: 4.9-5.25V, 8.5-9.5V, 11.5-12.5V
- Charging Time Estimates: 3.5h at 5V, 3A; 3h at 9V, 2A; 3h at
12V, 1.5A
Frequently Asked Questions (FAQ)
Q: How long does it take to fully charge the power bank?
A: The charging time varies depending on the input voltage and
current. It is estimated to take around 3.5 hours at 5V, 3A; 3
hours at 9V, 2A; and 3 hours at 12V, 1.5A.
Q: What are the different working modes of the power bank?
A: The power bank has three working modes – Sleep, Standby, and
Operation. Sleep mode activates when no keys are pressed, and there
is no load or charge to save power consumption.
“`
Manual
Product Specification
Document NumberBBD-WI-001 Product NamePOWER BANK-GPB 10000mAh Product Model
GPB-MB10(Black); GPB-MW10(White); GPB-MX10(X represents the color variable)
EditionV1.0
Date: 2023.12.8 From: Aspirer Model No: GPB-MB10(Black); GPB-MW10(White); GPB-
MX10(X represents the color variable) Specification: (38.5Wh) 3.85V/10000mAh
Total No. of Pages :Total 16 pages including this cover sheet 16 (
Audit confirmation:
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 1 of 18
Aspirer
Name Date
Written
Checked
Checked
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 2 of 18
Update history
No.
Date
Edition
1
2023.12.8
V1.0
Contents
Initial release
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 3 of 18
1 Scope of application……………………………4 2 Product parameters…………………………..5-10 3
Reliability and Safety Testing…………10 4 Mechanical…………………………………..11-13 5PCB PCB
and Board Connection…………………..14 6 Electrical block diagram ……………………..15 7
Schematic diagram……………………………….15 8 Storage…………………………………………..15 9 Matters
needing attention……………………….16
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 4 of 18
1 Scope of application This specification is applicable to the mobile power
supply produced by our company.
Product components: 1.1 1 section10000mAh/3.85V Electric core 1.2 2 Chip
Circuit Master Control Board 1.3 Shell and other structural parts 1.4 Test
Conditions and Instruments and Equipment Requirements a Test environment
conditions bUnless otherwise specified, the tests in this specification shall
be conducted under standard atmospheric conditions. c temperature25 d relative
humidity10%~90% e Atmospheric qualityAM1.5 f 0.5 10K/V The instrument accuracy
of measuring voltage should be no less than 0.5 grade and the internal
resistance should be no less than 10K/V. g 0.5 The instrument accuracy of
measuring current should not be less than 0.5 grade. h±1The accuracy of the
instrument used for measuring temperature should not be less than (+1 C) 1.5
Working state of mobile power supply
Mobile power supply has three working modes: sleep, standby and operation.
Tsleep Tsleep Tsleep No response in Tsleep: refers to not pressing keys, no
load, no charge in the sleep waiting time (Tsleep). Batteries will
automatically sleep to save power consumption, so as to achieve longer storage
time. Tsleep is about half a year old.
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 5 of 18
2. Product Parameters
Performance as scheduled
project
capacity /mAh
weight /g
size /mm
Self-consuming
electricity /uA
Ov Charging
er temperature /
al Discharge
l
temperature /
ch Storage
ar humidity
ac Storage
te Temperature/ ri st Machinecase ic temperature / s
Conversion Rate of
Whole Machine /%
size/mm Core Category Nominal capacity /mAh Co Standard re voltage /V ch nternal ar resistance /m ac te Authentication ri st ic cycle life s
standard 10000mAh /3.85V
245 1097120.30 <700uA (MAX)
0-40 -10-40 75% 535
65
70 126280 Polymer battery 10000 3.85V
<60 –
300
4.4±0.05
Remarks 0.2C Discharge with discharge cabinet at 0.2C current Tolerance
range±10g Tolerance range±0.3mm
Average Standby Current
ambient temperature 4 2 Low temperature 4 hours, high temperature 2 hours
/
Half a year
25ambient temperature25
5V/1A
±0.5mmTolerance range: +0.5mm /
/
/
/ Reference Core Specification 3 80% Battery discharge capacity less than 80%
of rated capacity for three consecutive times is the end of life.
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 6 of 18
Overcharge
protection /V
Overdischarge
2.4±0.1
lithi protection /V
um
Overcurrent
15±3
Ele
protection /A
ctri
cal
prot
ecti
Short circuit
on
protection
perf
function
YES
100 m P+,P-Short-circuit P+, P with 100 m_load-
orm
anc
e
Charging mode
MICRO Charge
Charging mode
– Constant Current-Constant Pressure
/
Charging
input
/
/
voltage
/
/
ICHG/mACharging
/
Ch current
/
ar
/
/
gi
Full of
ng
time /h
/
/
/
/
ch
ar
/
/
ac
Full Voltage /V
te Type-c Charge
ri Charging st mode
–
CC/CV 18W
ic
5V
PCBA
s Charging
input
9V
4.8VSupporting charging current
voltage
12V
varies according to CC/CV mode of charging
5V;0-3000 CC 2.5-3.3A management, 18W fast charging, charging
9V;0-2000 CC 1.5-2.2A
current is determined by the voltage of
ICHG/mACharging
external power supply and the length of
current
12V;0-1500 CC 1.2-1.75A connection line. It is recommended that
the input voltage of PCBA terminal be >
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 7 of 18
Full of time/h
Full Voltage /V Input voltage range /V Input Overvoltage Protection Range /V
Output port USBA1 QC Output No-load Voltage
/V
USBA1 QC Output Load Voltage /V
USBA1 QC Output Port
USB2 Output No-load Voltage /V
USB2 Output Load Voltage/V
USB2 Output Port Ripple /mV
Type-c PD3.0 Output no-load voltage/V
Type-c PD3.0 Output Load Voltage/V
Type-c Output Port
Estimate 3.5h5V,3A Estimate 3h9V,2A Estimate 3h12V,1.5A
4.4±0.05
4.5-14
14±0.5
4.9-5.25 8.5-9.5 11.5-12.5 4.75-5.25 8.5-9.5 11.5-12.5 D+/V OUT/5V D-/V OUT/5V
D+/V OUT/9V D-/V OUT/9V D+/V OUT/12V D-/V OUT/12V
/
/
/ / <150 4.9-5.25 8.5-9.5 11.5-12.5 4.75-5.25 8.5-9.5 11.5-12.5 D+/V OUT/5V
D-/V OUT/5V D+/V OUT/9V D-/V OUT/9V D+/V OUT/12V D-/V OUT/12V
4.8V. / / / /
/
PCBA PCBA Board End Voltage
No load
3.0A USB 2.0A USB 1.5A USB 2.7±0.2 No load 2.7±0.2 No load
/ / / / /
/
/
No load
3.0A USB 2.22 A USB 1.67A USB 2.7±0.2 No load 2.7±0.2 No load
/ / /
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 8 of 18
Ripple /mV
<150
3.0A
5W
Wireless charging output
7.5W 10w
15w
Simultaneous output
5V/3A
TYPE-C+USBA1+Wireless
Overdischarge voltage
2.9±0.2
/
protection /V
Overcurrent protection /A
3.6±0.5
When the load current increases, the voltage output will be automatically reduced, and the load button
will be removed to restore.
Short circuit protection
YES
Pull out load automatic recovery
Output efficiency
85%
PCBA PCBA efficiency
Fill and place
5V1A
The output has no short circuit protection when charging and discharging
Output open no-load
<20mA
/
current
Current and time of light
<100mA, 25±10S
/
load shutdown
USB1,TYPE-C
Supports USB1,TYPE-C, and wireless
charging to automatically identify the
Key load output. When the product has
Output mode
switch and automatic output
overcurrent protection or short circuit protection, the protection needs to be removed and the load needs to be reinserted to automatically turn on the output. When
the product is powered on for the first
time or the battery voltage is too low to
trigger the low power shutdown, it needs
to be activated by charging.
basic function
Key
Power on: Press once Shutdown: Double click
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 9 of 18
1Type-c , LED
2USB1 Type-c LED
5%
3
Working mode
1. Type-c charging, white LED running horse side, indicating the current charging indicator flashing.
2. When USB1 or Type-c is exported, the white LED
displays the current power. When the product power is
reduced to 5%, the indicator lights flicker and the
power is not enough.
3.When the product is in sleep mode, press the button
to turn on output and check the battery level.
Electricity Indicating Stat
25%
26%—50%
51%—75%
76%—99%
100%
LED
Electric quantity 25% the first light flash
charging indicator status Electric quantity 26% – 50% the second light flash
Electric quantity 51% – 75% the third light flash
Electric quantity 76% – 99% the fourth light flash
Electric quantity 100% charge full LED lights all lights on
*LEDAll the LEDS will run the same way
the first time the power is turned on
Charge+ discharge
Display charging status
indicator status
LED
Fully charged indicator
All LED turns light
No power
No power
5%
The first LED flashingBattery low voltagealarm
6%—25%
One LED on
26%—50%
Two LED on
51%—75%
Three LED on
LED /Wireless charging LED indicator
76%—100%
Four LED on
1. LED 1 2 LED 1. Wireless
output opens green LED light flash 1, then extinguishes. 2. During wireless charging, the LED
light goes out, and the light flashes when there are foreign matters.
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 10 of 18
TYPE-C1 C A port support protocol
USBA1/USBA2 A A port support protocol
5V/3A 9V/2A 12V/1.5A 18W
TYPE-C 5V/3A 9V/2.22A 12V/1.67A 20W
USB-A 5V/3A 9V/2A 10V/2.25A 12V/1.5A 22.5W 5W 7.5W 10W 15W MAX
5V3A 15W
APPLE 5V2.4A SAMSUNG 5V2.0A BC1.2 DCP 1.5A
QC2.0 9V 12V QC3.0 3.6-12V QC4+ SAMSUNG AFC 9V 12V
HUAWEI FCP 5.0V 9.0V 18W HUAWEI SCP 3.4-12V 25W
MTK PE1.1 PE2.0
PD3.0 PPS 22W 5V3A 9V2.22A 12V1.67A
5.0-5.9V 3A 5.0-11.0V 2A
APPLE 5V2.4A SAMSUNG 5V2.0A BC1.2 DCP 1.5A
QC2.0 5V 9V 12V QC3.0 3.6-12V SAMSUNG AFC 9V 12V
HUAWEI FCP 9V 12V 18W HUAWEI SCP 3.4-12V 25W
MTK PE1.1 PE2.0
3 Reliability and Safety Testing
Serial number
Test items
Standard requirements
Remarks
5V , 1 , 4.45VAdd
Overcharg 5V charging voltage at the charging end and continue charging for
1 e
1 day after full charge. The core voltage does not exceed 4.45V.
protectio
n
, 2.9±0.2V ,The
Overdisch product is set to discharge. When the voltage of the core is less
2
arge than 2.9 + 0.2V, the output of the product will be closed.
protectio
n
, 0.1m 1H,
Short When charged, the battery pack should not smoke, explode, ignite or
3
circuit smell with 0.1m_resistance short circuit output 1H.
protectio
n
1 1 Drop test 1m, fall three times on each 4
Drop test side.
150CPM 2.5HZ 90min3 =30s/
According to the speed 150CPM,
5 Vibration frequency 2.5HZ, time 90min (3 sides = 30s/side) simulated vibration,
test
packaging must not be seriously damaged, the product should not
exceed the functional standard.
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 11 of 18
, 200g , 30~40 /
200 / Use cotton cloth to dip in alcohol and
Alcohol wrap it on a 200 g French wharf. Wipe it 200 times at 30-40 times
Resistanc per second (once back and forth). No primer can be
exposed/unpainted. 7
e Testing
of
Spraying
Coatings
, 200g , 30~40 /
100 Dip a cotton cloth full of
Screen alcohol and wrap it on a 200g weight dock. Wipe it 100 times at a
8
Printing speed of 30-40 times/second (once back and forth). After testing,
Wear the silk screen font should not fall off.
Resistanc
e Test
4. Mechanical
Shell Material Plastic PC+ABS Assembly mode Buckle surface treatment Rubber
oil Fire Grade 94V-0 4-1.(:mm ±0.3mm) Outside Drawing (Unit: mm
Tolerance±0.3mm)
4-2. Assembly Diagram
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 12 of 18
4-3: Photo of the Product and Pin Assignment < Top side view>
4.4< Port Definitions> ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 13 of 18
LED Electric quantity display Wireless charge 15W
Key switch
USB-A Output TYPE-C PD Input and Output
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 14 of 18
5. PCB PCB and Board Connection PCB PCB Model :MSA10-A V1.0 MSA10-B V1.0 PCB
PCB Sheet and Fire Grade FR4, 94V_0
MSA10-A V1.0
MSA10-B V1.0
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 15 of 18
6. Electrical block diagram
7. Schematic diagram
8. Storage 3 5-3575%RH Long-term storage (more than 3 months) shall be placed
in temperature for 5 to 35 , humidity environment for 75% RH or less. ShenZhen
FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 16 of 18
3 1 The product should be charged once every 3 months during storage. 9.
Matters needing attention
9.1 All electrical parameters shall not exceed the stipulated in this
specification.
9.2 Prohibit open mobile power supply. PCBA Under no circumstances shall not
remove the mobile power supply, more shall not remove the built-in PCBA and
batteries, remove the mobile power can lead to internal short circuit,
resulting in fire, batteries, summon up and other issues.
9.3 With sharp parts collision mobile power supply is prohibited.
9.4 It is prohibited to fall, impact, bending mobile power supply.
9.5 It is forbidden to move the power into the fire.
In any case, it may not burn mobile power or will move into the fire,
otherwise it will cause internal batteries burning, may cause explosion, very
dangerous, should be absolutely prohibited.
9.6 It is forbidden to mobile power immersed in a liquid.
The mobile power supply must not be immerse in any liquid, such as fresh
water, sea water, beverage, gasoline and so on.
9.7 It is forbidden to mobile power placed in high temperature environment.
9.8 It is forbidden to mobile power discarded in ordinary tips.
9.9 To ban the use of damaged mobile power supply.
Mobile power supply in the process of transportation may be due to the impact
of damage, if there is any abnormalities found mobile power supply, shall not
be used, and should be far away from the fire source, the sun is high
temperature occasion such as to avoid danger.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:(1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 17 of 18
user’s authority to operate the equipment. This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna. -Increase the separation between
the equipment and receiver. -Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. -Consult the dealer or
an experienced radio/TV technician for help. The device has been evaluated to
meet general RF exposure requirement. The device can be used in portable
exposure condition without restriction.
ShenZhen FAB-CHAIN SERVICE Co. Ltd
5th Floor ,Bldg A,Chuang Jian Industrial Park,2028#,Song Bai
Road,shiyan,BaoAn,ShenZhen,China
: A5/B4
Http://www.fab-chain.comPage 18 of 18
Read User Manual Online (PDF format)