Change Units of Measurement (UoM)
-
Press Menu Button to enter Setting menu, then press Menu button
to scroll to the UoM option screen is displayed. -
Press Navigation Buttons to scroll through the UoM options
(Meters/Degrees, Meters/Percent (%), Feet/Degrees, Feet Percent
(%)).
Select Targeting Mode
-
Press Menu Button to enter Setting menu, then press Menu button
to scroll until the Targeting Mode option screen is displayed. -
Press Navigation Buttons to scroll through the Targeting Mode
options (- Standard (Std), Filter (FILt), Closest (CLo), Farthest
(FAr), Continuous (Cont)). -
Press Select button to make the current Targeting Mode
displayed the active mode. -
Ready to take measurement with selected Targeting Mode option.
The icon of selected mode will be displayed. -
Repeat steps to change target mode option.
Measure Distance
-
Press the Navigation buttons until the measurement screen is
displayed. -
Aim at the target where you have a clear line of sight then
press-and-hold the fire button.- The laser indicator will be displayed until measurement is
acquired or fire button is released.
- The laser indicator will be displayed until measurement is
-
Press Navigation Buttons to scroll through the other
measurement values calculated. -
Press Fire button to clear measurements and repeat the
steps.
FAQ:
Q: How do I change the units of measurement?
A: To change the units of measurement, follow the steps outlined
in the “Change Units of Measurement” section above.
Q: How do I select a targeting mode?
A: To select a targeting mode, refer to the “Select Targeting
Mode” section provided in the user manual.
Q: How do I measure distance accurately?
A: To measure distance accurately, follow the instructions under
the “Measure Distance” section above.
“`
TruPulse® 200i & 360i Quick reference field Guide
LTI Part 0145003
© LTI 2024 Rev 01
TruPulse® i Series
Navigation Buttons Menu Button
Select Button
Fire Button
LTI Technical Support Toll Free: 1.877.696.2584 Phone: 1.303.649.1000 Email:
service@lasertech.com
Web: lasertech.com
LTI Hours of Operation Monday through Friday
8:00 am to 5:00 pm (MST) (Excluding Holidays)
LTI Corporate Headquarters 6912 South Quentin Street, Suite A
Centennial, CO 80112 USA
LTI YouTube® Channel YouTube.com/lasertechpro for TruPulse® Training Videos
*For detailed instructions on the TruPulse i Series operations, please refer to lasertech.com/professional-measurement-products and navigate to the TruPulse product’s webpage.
TruPulse® i Series Display Icons
Measurement Modes
Inclination Slope Distance Horizontal Distance Vertical Distance
Height
Display Icons Battery Life Indicator Laser Firing Feet Meters Azimuth
Missing Line
Percent
Target Modes
Closest
Farthest
Continuous
Filter
Bluetooth
Gate Indicators
TruPulse® 200i Values & Key Code
Measured by TruPulse Calculated by TruPulse
1-Shot Distance
2D Missing Line
= Horizontal Distance (HD)
= Slope Distance (SD)
= Vertical Distance (VD)
= Height (HT)
2-Shot Height
3-Shot Height
= Inclination (INC) Missing Line Routine (ML)
Measurement Icons
Inclination Value
Range Value
TruPulse® 360i Values & Key Code
Measured by TruPulse Calculated by TruPulse
1-Shot Distance 3D-Shot Missing Line = Horizontal Distance (HD)
SD
VD
AZ
INC
HD
SD SD
VD
INC
HD AZ
AZ
SD
INC AZ INC
= Slope Distance (SD) = Vertical Distance (VD) = Azimuth (AZ) = Inclination (INC)
2-Shot Height
3-Shot Height
Inclination Value
Azimuth Value
Measurement Value
Change Units of Measurement (UoM)
[1] Press Menu Button to enter Setting menu, then press Menu button to scroll
to the UoM option screen is displayed. The last UoM
options chosen will be displayed.
[2] Press Navigation Buttons to scroll through the UoM options.
Meters/Degrees, Meters/Percent (%), Feet/Degrees, Feet Percent (%)
Select Targeting Mode
The TruPulse i Series has five Target Modes which allow you to select or
eliminate targets and to take the most accurate measurements possible in
various field conditions. [1] Press Menu Button to enter Setting menu, then
press Menu button to scroll until the Targeting Mode option screen is
displayed. The last Targeting option chosen will be displayed.
[2] Press Navigation Buttons to scroll through the Targeting Mode options. –
Standard (Std) , Filter (FILt), Closest (CLo) , Farthest (FAr) , Continuous
(Cont) [3] Press Select button to make the current Targeting Mode displayed
the active mode. [4] Ready to take measurement with selected Targeting Mode
option. The icon of selected mode will be displayed. Standard Mode does not
have an icon displayed. [5] Repeat steps to change target mode option.
NOTE: Any option that chosen will be set when you return to the Measurement
Mode. To save the option and be active when the unit powers off and on:
Manually power off the unit.
Measure Distance
· In the Slope Distance Mode , the TruPulse i Series will automatically
calculate and .
· Measurements are from the ¼-20 tripod mount (center) of the laser to the
target.
[1] Press the Navigation buttons until
screen is displayed.
[2] Aim at the target where you have a clear line of sight then press-and-hold
the fire button
[2.1] The laser indicator will be displayed until measurement is acquired or
fire button is released.
[3] Press Navigation Buttons to scroll through the other measurement values
calculated.
Measure Distance Continued
[4] Press Fire button to clear measurements and repeat step 1 through 4
HelPful TiP
The Vertical Distance solution can be used to measure height or clearance. In
Fig. 1 & 2, just add the height of the laser at your eye level from the ground
to the measurement.
Fig. 1
SD
VD
AZ
INC
HD
Fig. 2
Measure Height (3-pt Routine)
This routine is ideal for flat, vertical objects that do not lean. To shoot
through brush, use the filter mode, foliage filter and a reflector.
[1] Press Navigation buttons until
is displayed.
[2] Aim where you have a clear line of sight to the target and press-and-hold
fire button .
[2.1] The laser indicator will be displayed. The horizontal distance is
acquired and displayed. [3]
is displayed, aim to the bottom of the target, press-and-hold fire button
the inclination Angle_1 is measured and displayed.
[4]
is displayed, aim at the top of target, press-and-hold
angle_2 is measured and displayed.
, the inclination
Measure Height (3-pt Routine) Continued
[5] Height measurement is calculated with calculated height value.
, display flashes then solid
HelPful TiP
· The laser sensor does not measure when taking the two inclination angle
measurements. You do not need a clear line of sight to the bottom or top of
your target.
· The sequence of the two inclination angles shots does not matter: Bottom to
Top OR Top to Bottom.
· Press the Select button during the Height routine to re-measure previous
measurement (ANG__1 or ANG_2), ideal for taking multiple height measurements
on the same target.
Measure Height in 2-Shots
This measurement routine is ideal for leaning objects and requires a clear
line of sight for both shots.
[1] Press Navigation buttons until is displayed
[2] Aim where you have a clear line of sight to the bottom of the target and
press-and-hold fire button
[2.1] The laser indicator will be displayed. When the measurement is
acquired will be displayed. Note this value for the Vertical Distance (VDb)
measurement.
[3] Aim where you have a clear line of sight at the top of the target then
pressand-hold the fire button .
Measure Height in 2-Shots Continued
[4] The laser indicator will be displayed. When the measurement is acquired
will be displayed. Note this value for the Vertical Distance top (VDt) value.
[5] Subtract the two values to calculate the height, VDt -VDb = Height.
NOTE: when subtracting the values, pay attention to the sign of the VD.
Measure 2D Vertical Missing Line
[1] Press Navigation Buttons until
is displayed.
[2] Aim where you have a clear line of sight at target, press-and-hold fire button [2.1] The laser indicator will be displayed. When the measurement is
acquired
Shot.1 results will be displayed.
[3]
is displayed, Aim where you have a clear line of sight at target, press-
and-hold fire button.
[3.1] The laser indicator will be displayed. When the measurement is
acquired
Shot.2 results will be displayed.
Measure 2D Vertical Missing Line Continued
[4] The HD and INC ML values will be calculated and displayed
, press navigation buttons to scroll through the SD and VD ML values from shot
1 to shot 2.
[5] Press Check button to scroll to
and re-measure the Shot.2,
[6] Continue to press Check button to return to step 1.
[7] Press fire button to return to step 1.
HelPful TiP
· Position yourself where shot 1 and 2 are made looking in the same direction
with a clear line of sight to both targets.
· The VD solution will always be accurate no matter which direction shot 1 and
2 are taken. · If shot 1 is higher than shot 2, the VD value will be negative.
Measure 3D Missing Line (TruPulse 360i only)
[1] Position yourself anywhere you have a clear line of site to your two targets. [2] Press Navigation Buttons until
is displayed.
[3] Follow the same steps 2-7 from the 2D Vertical Missing Line routine. [4]
The TruPulse 360i calculate five variables between the two points: slope
distance, inclination, azimuth, horizontal distance, and vertical distance as
shown in Figure.
TiPs: imProvinG THe accuracy resulTs
· During the Missing Line Routine, it is important that the TruPulse stay
positioned above one particular point on the ground.
VD
SD SD INC
· Mounting the TruPulse on a monopod or tripod will improve the
HD AZ
accuracy of your results location of the TruPulse.
· If you are using the TruPulse handheld, be aware of your body
having a swinging motion as you aim to second target.
AZ
SD
INC AZ INC
User Field Calibration: Compass
To begin the routine, you should be holding the TruPulse and facing towards
Magnetic North. Always perform outside and away from magnetic interference.
[1] Press Menu button to enter Setting menu. [2] Press Menu button
to scroll to the User Calibration option
.
[3] Press Navigation Buttons to
, then press select button .
HelPful TiP
· Always recalibrate your compass when Calibration icon flashes. · If
calibration fails repeatedly, perform the tilt calibration then repeat steps.
User Field Calibration: Compass Cont’d
[1] Face North (± 10°), hold in position 1 (C1_Fd), press . [2] Hold in
position 2 (C2_dn), press . [3] Hold in position 3 (C3_bc), press .
[4] Hold in position 4 (C4_UP), press . [5] Hold in position 5 (C5_rF), press
. [6] Hold in position 6 (C6_rd), press . [7] Hold in position 7 (C7_rb),
press . [8] Hold in position 8 (C8_rU), press . [9] If FAIL message appears,
press , re-enter the Compass Calibration menu and repeat steps 1-8. [10] If
PASS message appears, press Select to save and return to the measurement
screen.
lasertech.com 1.303.649.1000 info@lasertech.com
Navigate to the correct model and then Downloads
for the User Manual
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>