GoldStar WM8003 Room Air Conditioner Owner’s Manual
- July 30, 2024
- Goldstar
Table of Contents
GoldStar WM8003 Room Air Conditioner
Product Information
Specifications
- Brand: GOLDSTAR
- Model: WM8003
- Type: Air Conditioner
- Parts Compatibility: 241 Models
Product Usage Instructions
Installation
- Choose a suitable location for the air conditioner near a power outlet and with proper ventilation.
- Ensure the unit is placed on a flat, stable surface to prevent vibrations.
- Securely attach any necessary brackets or support for installation on windows or walls.
Operation
- Plug in the air conditioner and turn on the power using the control panel or remote.
- Set the desired temperature and fan speed for optimal comfort.
- Clean or replace filters regularly to maintain efficiency.
Maintenance
- Regularly clean the exterior surfaces with a damp cloth and mild detergent.
- Inspect and clean the air filters to ensure proper airflow and cooling performance.
- Schedule professional maintenance checks annually for optimal functionality.
FAQs
- Q: Where can I find genuine replacement parts for GOLDSTAR WM8003?
- A: Genuine replacement parts can be found at Appliance Factory Parts, as provided and hosted in the Owner’s Manual.
- Q: How do I select the appropriate parts for my specific model among the 241 compatible models?
- A: Refer to the model number (WM8003) when selecting parts to ensure compatibility with your GOLDSTAR air conditioner.
3. INSTALLATION
3.1 SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the unit
is installed securely and firmly.
2. Install the unit where the sunlight does not shine
directly on the unit.
3. The outside of the cabinet must extend outward for
at least 11″ and there should be no obstacles, such
as a fence or wall, within 20″ from the back of the
cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner
CAUTION
All side louvers of the cabinet must remain
exposed to the outside of the structure.
4. Install the unit a little slanted so the back is slightly
lower than the front (about ½”). This will help force
condensed water to the outside.
5.Install the unit from the bottom about 30″~60″
above the floor level.
3.2 CHECK OF INSTALLATION
The setting conditions must be checked prior to initial starting.
The undermentioned items are especially important checking points when the
installation is finished.
1. Grounding wire (Green or Green and Yellow) is provided in the power cord.
The green wire must be grounded.
2. Connect to a single-outlet 15A circuit.
3. To avoid vibration or noise, make sure the air conditioner is installed
securely.
4 Avoid placing furniture or draperies in front of the air inlet and outlet.
3.3. HOW TO DRAIN
(When using drain pipe)
The air conditioner must be installed horizontally or tilted slightly to the
outside for proper water drainage.
On exceptionally hot and humid days the air conditioner may overflow condensed
water.
If the air conditioner is used in a hot and high
humidity zone, exchange the *HOLE RUBBER
for the MDRAIN PIPE.(See figure 18, figure 19.)
3.4 HOW TO INSTALL
3.4.1 WHEN USING GASKET
3.4.2 WHEN USING INSTALLATION KITS
A. WINDOW REQUIREMENTS
This unit is designed for installation in
standard double hung windows with actual opening
widths from 22″ to 36″.
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of 15″
from the bottom of the upper sash to the window
stool.
B. INSTALLATION KITS CONTENTS
SUGGESTED TOOL REQUIREMENTS
SCREWDRIVER+, -), RULER, KNIFE, HAMMER
PREPARATION OF CHASSIS
1. Remove the screws which fasten the cabinet at both
sides and at the back.
2. Slide the unit from the cabinet by gripping the base
pan handle and pulling forward while bracing the
cabinet.
3. Cut the window sash seal to the proper length.
Peel off the backing and attach the foam-pe a to the
underside of the window sash.
4. Remove the backing from the top upper guide Foam
PE a and attach it to the bottom of the upper guide
a .
5. Attach the upper guide onto the top of the cabinet with
3 type A screws.
6. Insert the frame guides mæinto the bottom of the
cabinet.
7. Insert the Frame Curtain a into the upper guide a
and frame guides na
8. Fasten the curtains to the unit with 4 Type A screws.
CABINET INSTALLATION
1. Open the window. Mark a line on center of the
window stoolor desired air conditioner location).
Carefully place the cabinet on the window stool and
align the center mark on the bottom front with the
center line marked in the window stool.
2. Pull the bottom window sash down behind the upper
guide until it meets.
NOTE:
• Do not pull the window sash down so tightly that the
movement of Frame Curtain is restricted.
3. Loosely assemble the sill support using the parts in
Figure 22.
4. Select the position that will place the sill support
near the outer most point on sill (See Figure 23)
NOTE: Be careful when you install the cabinet (frame
guides a are broken so easily).
5. Attach the sill support to the cabinet track hole in relation to the
selected position using 2 Type A screws in each support(See Figure 23).
6. The cabinet should be installed with a very slight tilt(about ½”) downward
toward the outside (See
7. Attach the cabinet to the window stool by driving the crow i Tan i on ange
on notes and
8. Pull each Frame curtain fully to each window sash track, and repeat step
2.
9. Attach each Frame curtain the window sash using screws • (Type C) (See
Figure 25)
CAUTION: DO NOT DRILL A HOLE IN THE
BOTTOM PAN.
10. Slide the unit into the cabinet (See Figure 26)
CAUTION: For security purpose, reinstall screws(Type
A) at cabinet’s sides.
11. Cut the foam-strip to the proper length and insert between the upper
window sash and the lower window sash.
(See Figure 27)
12. Attach the window locking bracket • with a type C screw. (See Figure 28)
13. Attach the front grille to the cabinet by inserting the tabs on the
grille into the tabs on the front of the cabinet. Push the grille in until it
snaps into place.
(See Figure 29)
14. Lift the inlet grille and secure it with a type A screw through the front
grille.
(See Figure 30)
15. Window installation of room air conditioner is now completed. See
ELECTRICAL DATA for attaching power cord to electrical outlet.
3.5 HOW TO USE THE REVERSIBLE INLET GRILLE
1. If you want to pull out the filter upward, open the inlet grille slightly.
Turn inside out the front grille.
Disassemble the inlet grille from the front grille with separating the hinged
part by inserting a — type screw-driver tip.
Rotate the inlet grille 180 degrees and insert the
hooks into the lower holes of front grille.
Then, insert the filter. (See Figure 32, 33)
2. Attach the front grille to the cabinet by inserting the
tabs on the grille into the tabs on the front of the
cabinet. Push the grille in until it snaps into place.
(See Figue 34)
3. Lift the inlet grille and secure it with a type A screw
through the front grille.
(See Figure 35)
4. If you want to pull out the filter downward, use the
reversible inlet grille without change.
(The grille is already assembled for that way.)
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Goldstar Air Conditioner Parts - Select From 241 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>