Chignon ZX-530 Ultrasonic Retainer Cleaner User Manual
- July 26, 2024
- Chignon
Table of Contents
- Chignon ZX-530 Ultrasonic Retainer Cleaner
- Product Information
- Product Usage Instructions
- Frequently Asked Questions
- Product components and functions Introduction
- Product specifications
- Cleaning principle
- Application
- Operating steps
- Ultraviolet Sterilization Cleaning
- Problems that need attention when cleaning
- Safety Precautions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Chignon ZX-530 Ultrasonic Retainer Cleaner
Product Information
Product Specifications
- Model: ZX-530
- Rated voltage: 12V 2A
- Capacity: 200mL
- Power: 24W
- Tank size: 78x78x40mm
- Product size: 107x107x94.5mm
- Working time:
- Cleaning time: 5/10 mins
- Sterilizing time: 5 mins
- Frequency: 45KHz
Product Usage Instructions
Operating Steps
- Connect the power supply to turn on the machine.
- Pour clean water into the tank and place items to be cleaned inside, ensuring they are fully submerged.
- Short press the button to start a 5-minute cleaning cycle, indicated by a blue light.
- Long press the button for a 10-minute cleaning cycle.
- Rinse items with tap water after cleaning and wipe the machine dry for storage.
Ultraviolet Sterilization Cleaning
When the lid is closed, press the button on the top to activate ultraviolet
sterilization for 5 minutes. Press the button again to turn it off.
Frequently Asked Questions
Q: What should I do if the white light flashes during operation?
A: The flashing white light indicates high temperature. Allow the machine to rest for about 20 minutes before using it again.
Q: How often should I change the water in the tank?
A: It is recommended to change the water after each use for optimal cleaning performance.
Q: Can I clean wooden products with an ultrasonic cleaner?
A: No, wooden products are not suitable for cleaning in this ultrasonic cleaner.
Please read the instruction manual carefully before using it. Please keep this instruction manual properly
Product components and functions Introduction
- Lid
- Plastic Basket
- Bottom Case
- ON/OFF
- Tank
- Type-c Charging Port
- Indicator Light
- UV-C Sterilamp
- UV-C Charging Port
Product specifications
Model | ZX-530 | Tank size | 78x78x40mm |
---|---|---|---|
Rated voltage | 12V=2A | Product size | 107x107x94.5mm |
Capacity | 200mL | Working time | Cleaning time 5/10 mins Sterilizing time 5 mins |
Power | 24W | Frequency | 45KHz |
Cleaning principle
Use its waveform to propagate in a liquid medium to turn the liquid into air, a vacuum bubble is generated. The vacuum bubble generates a large pressure inside and out. The bigger bubble brings greater pressure and a greater impact force, which brings a higher destructive force when bubbles rupture. We will choose different ultrasonic frequencies according to different objects, which has a cleaning effect without damaging the object itself. If chemical agents are added, ultrasound can accelerate the chemical reaction speed and improve the cleaning efficiency!
- Ultrasonic waves travel through the water and produce millions of small vacuum bubbles.
- In the effect of ultrasonic, microscopic bubbles will continue to “explode” to impact the contaminant.
- Dirt splits into small granular from the surface during the high-pressure stage and falls into the
Application
Application | Species | Specific application |
---|---|---|
Dental Appliances | Retainer, mouth guard, aligner, dentures, etc | |
Daily necessities | Toothbrushes, razor blades, combs, etc | |
Jewelry | Rings, necklaces, earrings, etc. | |
Tableware supplies | Metal tableware, ceramic tableware, etc. | |
Not applicable | Species | Specific application |
--- | --- | --- |
wooden product | Turtle shell mirror frame, pearls, Turkish stone, Opal, |
emerald, coral, ivory, Emerald, stone, etc.
Watch body (including waterproof watch), Lacquerware
Gems with soft surface hardness
Inferior products for plating and finishing
Glued gems
Supplies with scratches and cracks
Operating steps
-
Connect the power supply, the white indicator light is on, confirm that the machine is powered on, and the machine enters the standby state.
-
Pour clean water into the cleaning tank and then place the item in it to be cleaned. The parts that need to be cleaned must be completely cleaned Immerse in water and keep the water level low.
-
In standby mode, short press the button, the white light goes out, the blue light stays on and enters the 5-minute working mode. After the work is over, The blue light is off, the white light is on, and the machine is on standby.
-
Long press the switch button, the white indicator light goes out, the blue indicator light flashes, and enters the 10-minute working mode. After the work is completed, the blue light goes out, the white light turns on, and the machine is in standby. (Press the switch button again during the working process, the machine resets, the white light is on, and the machine is on standby).
Tips: When the white light flashes, it indicates that the temperature of the machine is too high, and it enters the protection mode, please let the machine rest for about 20 minutes before using it. -
Rinse the items with tap water after cleaning to wash away the dirty things. Note: It is recommended to change the water every time you use it, and do the next cleaning after 5 minutes after cleaning.
-
After cleaning, take out the water in the stainless steel inner tank, and wipe the fuselage and stainless steel inner tank with a clean soft cloth. Store in a dry and flat place.
Ultraviolet Sterilization Cleaning
- When the lid is closed, press the button on the top of the lid, the blue indi-cator light will be on, the ultraviolet light be on, and it will be closed automatically after 5 minutes. In the sterilization process, press the button again, the blue indicator light is off, and the ultraviolet light is off.
- Please fill up the battery before using it, and the blue indicator light flickers when charging, After the charging is completed, the indicator light will be on for a long time. Please close the rubber plug after charging to prevent water from entering the charging port during cleaning
- Note: Please use a 5V power adapter for charging.
- When using the ultraviolet sterilization function, try to avoid direct body contact. Ultraviolet lamps are harmful to the human body and cannot direct the human body.
Problems that need attention when cleaning
- It may not be possible to completely remove tartar, sallow, dark spots, and smoking remaining in the denture.
- It may not be possible to clean the sedatives fixed in the dentures.
- Discoloration and rusting of metals and metals cannot be removed.
- When cleaning necklaces/rings that are bonded with gems/diamonds, the gems/diamonds may fall off.
- When cleaning the metal watchband, please remove the watchband from the main body of the watch before cleaning. Use only cleaning fluid or clean water.
Safety Precautions
To avoid fire, electric shock, and personal injury, please be sure to comply with the following requirements; others please follow the relevant national and local electrical regulations.
- Ultrasonic working environment: the ambient temperature requires 0℃-50℃,
- Cleaning fluid requirements: It is forbidden to use liquids that are corrosive to stainless steel and ABS plastic as cleaning fluids, and the temperature of the cleaning fluid should not exceed 60°C.
- The continuous working time of the machine shall not exceed 15 minutes, and there must be rest time in between.
- Requirements for placing the machine: If it is not used for a long time, please wipe the machine clean and ensure that the place where the machine is placed is not wet! Remember that there should be no liquid in the machine when it is stored.
- This product cannot be used as a child’s toy, and children are not allowed to use this product without supervision.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>