Specifications:

  • Model : PGN8EBF, PGN8FEBF
  • Type : Wall Mounted Contactless Refrigerated Bottle Filler
  • Water Treatment : QUASAR UV-C LED
  • Filter : Included in Filtered Models Only (PGN8F2EBQ)

Product Usage Instructions

Getting Started
What’s Included:

  • Drainpipe x2
  • Drain Elbow x2
  • T15 Torx Screws x2
  • Filter (Included in Filtered Models Only)

Tools & Hardware Required:

  • (Tools & hardware are supplied)

IMPORTANT QUASAR REQUIREMENT

  • CAUTION: DO NOT ACTIVATE BOTTLE FILLER ELECTRIC EYE SENSOR WITHOUT RUNNING WATER THROUGH THE UV-C MODULE. OPERATING THE UV-C MODULE DRY MAY DAMAGE THE UV-C LEDS.
  • QUASAR Information: QUASAR is a form of dispense point water treatment that utilizes UV-C LEDs to inactivate pathogens.

QUASAR LED Indicator Key

LED Indicator Display LED Color Display Condition Action
Orange UVC OFF- TURN ON THE WATER SUPPLY While dispensing, the UVC
temperature is too high. Ensure the water supply is ON. If initial start-up:

Activate the
bottle filler to dispense water. LED will turn BLUE when the water
flows.
Green| BOTTLES SAVED| N/A| N/A

Getting Started

What’s Included:

Tools & Hardware Required:

  • Electric drill/driver
  • Small tubing cutter for plastic line
  • 1/4” nut driver
  • Means to cut 1-1/4” drainpipe
  • T15 Torx screwdriver and bit
  • 4 appropriate anchors (not supplied)

IMPORTANT QUASAR REQUIREMENT

CAUTION : DO NOT ACTIVATE THE BOTTLE FILLER ELECTRIC EYE SENSOR WITHOUT RUNNING WATER THROUGH THE UV-C MODULE. OPERATING THE UV-C MODULE DRY MAY DAMAGE THE UV-C LED’S.

QUASAR® UV-C LED OPERATION

  1. QUASAR is a form of dispense point water treatment that utilizes UV-C LED’s to inactivate pathogens.
  2. Operation:
  3. The QUASAR activation is automatic. The UV-C LED’s turn ON when water is dispensed and OFF when the dispense stops.
  4. During non-use periods the QUASAR automatically cycles ON for ten seconds every ten minutes. This keeps the dispense point more sanitary between use.
  5. When the QUASAR is ON, the LED light on the front of the alcove near the top will turn BLUE.
  6. If QUASAR is not working properly, then the LED light on the front of the alcove near the top will be ORANGE. The light will remain ORANGE and the system will not allow water to be dispensed until the problem is resolved.
  7. IMPORTANT : Never operate the QUASAR without water connected to the system. Lack of water can cause the QUASAR to overheat. If it is necessary to activate QUASAR to purge the system of air, then the QUASAR will automatically shut off if it overheats. The QUASAR will resume operation once water begins to flow through it and/or once the module returns to safe operating temperature.

QUASAR LED Indicator Key

Single Level Rough-In Drawing

(REFRIGERATION COMPONENTS NOT SHOWN)

NOTES:

  1. TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED.
  2. ALLOW 4 INCHES [102MM] MIN. PER SIDE FOR VENTILATION.
  3. RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN. REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER. UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30[760] BY 48[1220]. ADJUST VERTICAL DIMENSIONS AS REQ’D TO COMPLY WITH FEDERAL, STATE, AND LOCAL CODES.
  4. ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS.

Preparation

Read these instructions before installing the unit.

  1. Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.

  2. Locate and install plumbing and electrical service, if required, in accordance with Roughing-in Drawing. See page 3.
    Note : The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI. CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well. State and local plumbing codes may prohibit the use of saddle-tapping valves for water line connection in some applications. All connections must conform to applicable plumbing codes.

  3. This drinking water cooler is designed to be operated at a water supply line pressure of up to 100 psi (690 kPa). A pressure regulator must be installed in front of unit’s water inlet if water pressure (including any possible pressure spikes) could exceed 100 psi (690 kPa).

  4. Check the available power supply against the water cooler data plate to ensure correct electrical service. This drinking water cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements. The rearmost 1-3/8” diameter knockout in frame bottom is for an externally located electrical supply. Make sure the knockout hole edge is smooth and free of any burrs. Use of a Heyco bushing #2184 in knocked out hole is recommended in order to prevent damage to the service cord and to close up excess opening around cord. Route cord so it does not interfere with ADA space requirements.

Chiller Installation

  1. Install the wall hanger onto the wall according to the rough-in drawing. See page 3. The Wall hanger is shipped fastened to the back of the chiller unit.

  2. Once the chiller unit is hung on the wall, Install a p-trap in the waste line and a shut off valve in water supply line.

  3. An in-line strainer is furnished in “Water Supply” tube. Connect “Water Supply” tube to shut-off valve.
    NOTE : This connection should not be a solder joint or flare connection to allow access to the strainer for service. Using one of the 1-3/4” diameter knockouts for a waste line is not recommended because of a potential conflict with ADA toe space clearance requirements. Check your local building code inspector for approval.

  4. Rotate fan blade by hand to see that it is free of obstructions.

  5. Leave the front panel off for the Bottle Filler installation.

Installation

  1. Unit comes partially assembled for shipping. Remove the kit from the packaging and separate it into the assemblies and components shown below.
    Tool Needed: T15 Torx bit

  2. Place the bottle filler frame against the wall and set it onto the top flange of the chiller frame.

  3. Affix the frame to the wall with at least 4 anchors into any appropriate anchor points through the staggered slotted holes. Be careful to ensure the frame stays centered on the cooler frame.

  4. With 4x T15 Torx screws, assemble the drip tray assembly to the center bracket and wall frame.

  5. Attach the filter support bracket with 2x T15 Torx screws to the frame and drip tray support bracket. This bracket helps to prevent the filter cartridge from falling into the cooler unit below during installation or replacement.

  6. Attach one of the drain elbows to the drip tray stem. Insert the drainpipe provided into the elbow and then attach another elbow onto the pipe. Use the remaining drainpipe and connect the drip tray drainage system to the installed P-trap.
    NOTE : Drainpipes will need to be positioned and cut to length as needed.

  7. Assemble unit wrapper to the installed frame. Rest the alcove on the drip tray and ensure the wrapper walls rest OUTSIDE of the frame and side brackets.
    NOTE : The drip tray will hold the weight of the wrapper but it is recommended to keep a hold on the unit during installation for safety.

  8. If the outer edge of the drip tray is not properly aligned, loosen the screws mounting the filter support and drip tray bracket to the frame and push forward or back as needed. Then retighten the screws. FOR UNFILTERED MODELS ONLY.

  9. Route the insulated cold water-out line up into the bottle filler cabinet and connect it to the solenoid valve located in the alcove.

FOR FILTERED MODEL PGN8FEBF ONLY.
Water Line Diagram

FOR FILTERED MODEL PGN8F2EBQ ONLY.
Water Line Diagram

FOR FILTERED MODEL PGN8FEBF ONLY.

Insert filter cartridge, rotate ¼ turn until locked. Connect the preassembled water source line to the shutoff valve. Note that there is an in-line strainer inside the copper tubing of the water source line. IMPORTANT: It is required to keep in-line strainer in system for unit to function properly; removing strainer can cause damage to solenoid valve and/or cartridge system (if applicable). Next, connect the filter water-out line. Route filter water-out line to container. Turn water supply ON. Flush filter for one-minute or until the water runs clear. After flushing filter connect filter water-out line cold tank inlet. Turn water supply OFF.

FOR FILTERED MODEL PGN8F2EBQ ONLY.

Insert filter cartridge, rotate ¼ turn until locked. Connect the preassembled water source line to the shutoff valve. Note that there is an in-line strainer inside the copper tubing of the water source line. IMPORTANT: It is required to keep in-line strainer in system for unit to function properly; removing strainer can cause damage to solenoid valve and/or cartridge system (if applicable). Next, connect the filter water-out line. Route filter water-out line to container. Turn water supply ON. Flush filter for one-minute or until the water runs clear. After flushing filter connect filter water-out line cold tank inlet. Turn water supply OFF.

FOR FILTERED MODEL ONLY.
After the frame has been installed (not shown), insert the insulated water line from the cold tank into the solenoid located at the top of the alcove assembly.

Connect the IEC connector to the power brick located behind the alcove of the bottle filler. It is recommended to route the power cord from side opposite of the condenser fan to ensure it does not become an obstruction.

FOR UNFILTERED MODEL ONLY.

  1. Turn on water source and check for leaks.
  2. Ensure nothing is obstructing the fan blade. Plug the power cord into the wall outlet and then test to ensure the bottle filler is functioning properly. Activate Bottle Filler sensor and dispense water into a container until the water becomes clear.
  3. Refer to the “SET-UP GUIDE FOR OASIS HANDS-FREE BOTTLE FILLER ELECTRONICS” program guide for further programming.

FOR FILTERED MODEL PGN8FEBF ONLY.

  1. Turn on water source and check for leaks.
  2. Ensure nothing is obstructing the fan blade. Plug the power cord back into the wall outlet and then test to ensure the bottle filler is functioning properly. Activate Bottle Filler sensor and dispense water into a container until the water becomes clear.
  3. Refer to the “SET-UP GUIDE FOR OASIS HANDS-FREE BOTTLE FILLER ELECTRONICS” program guide for further programming.

FOR FILTERED MODEL PGN8F2EBQ ONLY.

IMPORTANT INSTRUCTIONS FOR QUASAR MODELS:
REVIEW Section 2 & 3A: QUASAR UV-C LED OPERATION before proceeding. Failure to follow Section 2 & 3A can damage the QUASAR.

  1. Turn ON water supply and check for leaks.
  2. Plug bottle filler cord into the electrical outlet. The bottle filler will auto-calibrate and be set up specifically for that installation. Refer to the “SET-UP GUIDE FOR OASIS HANDS-FREE QUASAR BOTTLE FILLER ELECTRONICS” program guide for further programming. Access programing Pushbutton through top of Bottle Filler.
  3. Place bottle in the bottle filler alcove to dispense water. Activate sensor for approximately 15 seconds to purge air out of the system. Remove bottle for 5 seconds to allow LED to cool. Repeat until a steady stream of water dispenses.
  4. If everything works correctly, place the Top Cap onto the Bottle Filler and install the two (2) torx screws to fasten it in place.

Once the unit has been verified to be functioning properly, install the front cover panel by inserting the top flanch up between the wrapper and center bracket, then tipping the panel back to the fountain. Secure it with the 2x #8 hex or 2x T15 screws at the base of the unit.

INSTALLATION COMPLETE.

Maintenance and Decommissioning

Maintenance

  1. Inspection of condenser should be made at 3-month intervals. To remove dirt and lint from condenser, disconnect power supply cord, then use small stiff non-wire or vacuum cleaner attachment brush. Observance of this procedure will ensure adequate air circulation through condenser so operation is efficient and economical.
  2. Outside of unit can be wiped clean with mild soap and water mixture. Never use harsh chemicals or abrasive cleaners, including any chlorine solutions. Rinse thoroughly with clean water, then dry surfaces.

Overload Protection
The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload.

Lubrication
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.

To Discontinue use of Water Cooler

  1. Close water shut-off valve and disconnect power to the CHILLER.
  2. Provide container to catch water to be drained and place under the cold tank drain.
  3. Remove the drain plug from the drain tube.
  4. Actuate the bottle filler and allow the water to drain into the bucket. Replace drain plug.
  5. Disconnect power to the BOTTLE FILLER.
  6. Disconnect the water supply line at the shut-off valve.

WARNING: The warranty and the Underwriters’ Laboratory Listing for this machine are automatically voided if this machine is altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flooding and/or hazardous electrical shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

P/N 030099-704 Rev. B, Date : 02/2024

© 2024 LVD Acquisition, LLC

Oasis is a registered trademark of LVD Acquisition, LLC dba Oasis International

OASIS INTERNATIONAL

FAQ

Q: What should I do if the LED indicator displays an orange color?
A: Ensure the water supply is ON. If it’s the initial start-up, activate the bottle filler to dispense water. The LED will turn BLUE when water flows.